Loading...
HomeMy WebLinkAboutW-425506i Z ti O Z O O v 450 I o 430 420 SEE SHEET C6.04 I I 54f64.9>, 4.94' L T 44 45 �k 31I I 1-12" CROSS (FL) 3-12" GATE VAL VES (FLxM✓) 1-12'x8" REDUCER (FL) ' • ,. �� 1-8" GAVE VAL VE (FLxM✓) W/ CONC BLOCK/NG W _ , H 12 D/ W I x W V RO 13f0 - - W W v STANDARD 1 WATER SERVICE 46LF RESTRAINED _ PER C.O.R. STD DTL 320.1, JOINT PIPING TO THE - - _ - SEE SHEET C6. J1 (TYP) END OF THE STORM LINE DUE TO NON -CONFORMING 46 I d l 30 RESTRAINED JOINT PIPING HORIZONTAL SEPARATION / I WHERE STORM /S CLOSER THAN 10.' HORIZONTAL TO WATER 47 *-r \ l 29 MAIN ONL Y NEEDS TO GO 10' PAST THE STORM ON EACH END. - FIRE HYDRANT ASSEMBL Y I / 28 PER C. O.R. STD DTL 310.1, 48 - SEE SHEET C6.31 (TYP) 52f06.85, 7.00' RT 12'x6" TEE (M✓xFL) o �i 1-6" GATE VALVE (FLxM✓) a v � FIRE HYDRANT ASS Y 49 - W/ CONC BLOCK/NG � I°d 26 SEE SHEET WATER EASEMENT I _ TRACTA (TYP) 50 "1 A� (ACCESS &UTILITY) C6.03 - 25 = 22 1 I. 27 24 52f93.96, 7.49' L T 1 7 - ` 1-12"x45° BEND (M✓) I \ - - _ _ - A Q I - W/ CONC BLOCKING 52 _�L 2JLF 12" D/ / F 52f73.83, 0.20' L T _\- f 66LF 12" DI 44 72LF 12"D/ I IN 144LF 12"DI 1-12 x45° BEND (M✓) °' W 4 52fOQ�_: � � _ _ _BSBL W/ CONC BLOCK/NG �` �� - ' i - �0 15, t TRACT M TRA CT L (OPEN SPACE) EX TREE PROPERTY LINE (CR/T/CAL AREA) �_ TO BE SA VED ;L (TYP) (TYP) PROPOSED FIN/S ^- o GRADE CONTOU EX/ST7NG GROUND ® ROAD � (TYP) j � T PROPOSED GRADE ® ROAD � (TYP) -2 46.E PROPOSED 12" - WA TER (TYP) Z m ROW 4 EX/S71NG ELEV. PROPOSED ELEV. HOR/Z. SCALE. I- 30' ® ROAD � (TYP) ® ROAD f (TYP) - VERT. SCALE- 1 "=5' IN a 55+00 54+50 54+00 53+50 53+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 (T HIGH T STA: 51f46.93 HIGHPT EL: 437.21 P STA: 51f37.96 80.004VC81 �1, II II N v 52+50 52+00 51 +50 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS 7r.�l :a •► W h SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 10' UTILITY EASEMEN7 51f34.97, 7.00' RT / (TYP) 1-12'x8" TEE (FL) PROPOSED STREET 2-12" GA VE VAL VE (FLxM✓) LIGHT (TYP) 1-8" GAVE VAL VE (FLxM✓) W/ CONC BLOCKING SEE SHEET WATER EASEMENT C6, 08 (TYP) WA TER BSBL (TYP) I I �yrk TRACT N 3 -(OPEN SPACE) - + a ao /436� 15 : is 00 I y.. O ►I INI �� - O o 00 DCVA J. �s SCALE: 1" = 30' 0 15 30 60 EX GROUND CONTOUR (TYP) 49f91.41, 7.00' RT CONNECT TO EX WA TER 1-8x8,, TEE (FL) J--8" GATE VAL VES (FLxM✓) 1-12'x8" REDUCER (M✓) 2-8" LONG BODY TRANS/TON COUPLING (8" AC TO 8" DI) N FINAL CONNECTION BY CITY FORCES W/ CONC BLOCK/NG � Z O U Z U u H RESTRAINED LQ R JOINT PIPING '�) SEE SHEET C6.08 LOW PT ST : 50*41.99 1 " LANDSCAPE LOW PT : 434.72 IRRIGATION METER AND PW STA: 50*50.00 DCVA PER COR STD PLAN O PW EL: 434.39 O 34 .8, SEE LANDSCAPE 50. 01 VC ho P N L4.03 512, WW mm 64Q Oo� -2.00% 51 +00 50+50 50+00 M J S 7/26/23 HHH SURVEYED: DINERS SCALE. HOR ONTAL• NADVD 1988 991 KEL 9/12/23 HHH DESIGNED: AS NOTED KEL 10/11/22 HHH ROLL/ HEAVR/N DRAWN: MARY MOORE ONE INCH DATUM CHECKED: AT FULL SCALE ROLL/ HEA VR/N IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY ROLL/ HEA VR/N 12" POL YP/GGING STA77ON PER C.O.R. STD DTL 300.7, SEE SHEET C6.32 ii/ W X X CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN - - WA TER EASEMENT - - - - - - - - WATER BSBL EX/SRNG WATER PIPE IV] IN[ WATER RT77NG Ak FIRE HYDRANT ® WA TER METER •� TYPE I BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFAC7URER'5 RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONS7RUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXIS77NG U77LI77ES SHOWN/ ARE APPROXIMATE EX/STIIVG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRE7F THRUST BLOCKS REOU/RED ON ALL WATER RT77NGS PER C.O.R. 57D PLANS 330.2 AND 330.3. 8. WHERE NEW WA7FR MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARA 17ON. O O N M N v O O N N 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425506 IN COMPLIANCE WITH CITY OF RENTON STANDARDS i DEVELOPMENT ENGINEERING s os yqi 12/06/2023 � � L WATER UTILITY ABDOUL GAFOUR 11/09/2023 I ODATE: TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.05 � ROW 4 SHEET: OF: 53 93