Loading...
HomeMy WebLinkAboutW-425507Z ti O Z O O v TRACT M (OPEN SPACE) 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 66 EX GROUND CONTOUR (TYP) �. 8" POL YP/GG/NG I N I STATION PER COR ° STD. PLAN NO.. 300.7 EX TREE TO BE SA I/ED (TYP) Z2 \ e a 15' BSBL Em 430 420 410 65 � 64 � 63 51f77.31, 6.00' RT 1-8" PLUG (M✓) 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING u 91=11�311119 50*49.44, 5.60' RT 1-8"x11.25' BEND (M✓) W/ CONC BLOCK/NG 62 61 60�0 WA TER EASEMENT (TYP) \ WATER BSBL (TYP) \\r4'2 (TYP) . RESTRAINED JOINT PIPING �� J / TRACT L - �1 �053� 54 55 56 R (CRI T/CAL AREA) STANDARD 1 " WA TER SERVICE PER C.O.R. STD DTL 320.1, SEE SHEET C6.31 (TYP) 52+50 52+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w 51 +50 i Lllmv®II� mm SEESHEET C6.02 Q\ 0 58 59 E 10' U7/L/TY EASEMENT (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. N.11207im • 51 +00 50+50 TRACT) (STORM DRAINAGE) 49f 95.00, 6.00' RT 1-12x8" TEE (FL) 1-8" GATE VAL Vf (FLxU I) TOP OF NUT 424.20 2-12" GATE VALVES (FLxUd) TOP OF NUT 424.78 TOP OF NUT 424.91 W/ CONC BLOCKING GRADE CONTOUR (TYP) SEESHEET C6.01 50+00 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N Eml 430 420 1 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. 0 `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓� END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W 425507 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE Row 5 CONSTRUCTION RECORD DRA WINGS O O N M N v O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.06 SHEET: OF: 54 93