Loading...
HomeMy WebLinkAboutW-425508O v PROPOSED FIRE HYDRANT EX GROUND PER C. O.R. STD DTL J10.1, CONTOUR (TYP) SEE SHEET C6. J1 EX OFFS/TE TREE STANDARD 1 " WA TER SERVICE SEE SHEET PROPOSED FINISH PROPERTY L/NE TO REMAIN (TYP) PER C.O.R. STD DTL 320.1, GRADE CONTOUR (TYP) SEE SHEET C6.31 (TYP) C6.02 (TYP) SEE WA-1 PROF/LE, 76 � 75 � 74 73 72 71 7 SHEET C6.09 ` • �j / /�, WATER SETBACK (TYP) -A�f 69 68 67 70f 19.82 6.00' L T WATER T (TYP) EA 1-12 x45° BEND (FLxM✓)(R✓) W/ CONC BLOCK/NG - ��� , �' � 0 �BEF 1 " D/ RJ 71f00 N� w 'iris 72f �F '" (R✓ TRACTK�� -� (CRITICAL AREA),41, TOP OF SLOPE 7 �78 79 80 81 82 83 84 85 86 87 88 - 89 90 15' SETBACK 7LF (TYP) �� 70f26.51, 6.00' L T 7t�12 D/ 12'W TEE (FL) , 71f67. 00, 8.50 L T 1-12" GATE VAL Vf- (FLxM✓) 1-12" TEE (FL) TOP OF NUT 420.84 2-12" GATE VAL VE (FLxM✓) 1- 12 "ADAPTOR (M✓) TOP OF NUT 424.45 1-6" GATE VAL VE (FLxM✓) TOP OF NUT 424.47 TOP OF NUT 420.00 1-12"x8" REDUCER (FL) F/RE HYDRANT ASS'Y 1-8" GATE VAL VE (FLxM✓) 87M FLANGE 4062 TOP OF NUT 424.12 W/ CONC BLOCK/NG W/ CONC BLOCKING SEE SHEETS C7. 02-CZ 04 FOR UTILITY CROSSING NFORMA T/ON. 440 HIGH PT STA: 71f80.15 HIGH PT EL.• 427.11 PW STA.- 71f72.00 PW EL: 427.82 100.00 VC 0 0 EX/STING GROUND 0 ROAD � (TYP) mm L14� 430 Or BEGIN 70f00 = ROW 6 EL: 422.00 ?OAD IMPROVEMENT \ / 3.38 _ o \ PROPOSED 12" '- WATER \ i Z m � 0 J EXISTING ELEV. 0 ROAD (TYP) RO 6 PROPOSED ELEV. 0 ROAD f (TYP) HOR/Z. SC VERT. SC E. I" J0, E. 1" 5' 5382 FNC @ AP FNC @ AP 53 t.000 so@ e TRACT M (OPEN SPACE) TRACT L (CRITICAL AREA) 2" BLOW OFF / PER C.O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 72187.77, 8.19' L T ' 1-8" PLUG (M✓) 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING 1-8" POL YP/GG/NG STATION PER C.O.R. STD DTL 300.7, SEE SHEET C6.32 "�EEX TREE J 15' BSBL TO BE SA VED (TYP) 440 FILL AND COMPACT ROADWA Y PRISM TO F/N/SHED SUBGRADE PR/OR TO INS TALLAT/ON OF WATER MAINS (TYP/CAL ALL FILL AREAS) 1-- 1 1 II PROPOSED GRADE 0 ROAD � (TYP) Qo N L244-r `��'�W PROPOSED 8" WA TERM \ o 70+00 70+50 71 +00 71 +50 72+00 72+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w N.110m • 0 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR ROLL/ HEA l/R/N 73+00 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 430 420 410 73+50 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN - - WA TER EASEMENT - - - - - - - - WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING AK FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. J LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLANS 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/8/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROW 6 O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.07 SHEET: OF: 55 93 CONSTRUCTION RECORD DRA WINGS