Loading...
HomeMy WebLinkAboutW-425508Z ti O Z O O v PROPOSED FIRE HYDRANT EX GROUND PER C.O.R. STD DTL 310.1, CONTOUR (TYP) SEE SHEET C6.31 PROPERTY LINE EX OFFSITE TREE STANDARD 1" WATER SERVICE TO REMAIN (TYP) PER C.O.R. STD DTL 320.1, (TYP) SEE SHEET C6.31 (TYP) SEE WA-1 PROFILE, 76 1 75J 74 r 73 E6. SHET C09 <` / WATER SETBACK (TYP) 70f 19.82, 6.00' L T WATER EASEMENT (TYP) 1-12"x45' BEND (FLxUJ)(RJ) W/ CONC BLOCKING ' / r 14/1F. 12"D/ RJ1 171-1-00 1-- TRACT K� (CRITICAL AREA), J/ TOP OF SLOPE 15' SETBACK (TYP) 7LF 12" L BEGIN N 0 70f00 = ROW 6 EL: 422.00 ROAD IMPROVEMENT J 70+00 SEE SHEET PROPOSED FINISH C6.02 GRADE CONTOUR (TYP) 72 71 j I Q l� Q TRACT M (OPEN SPACE) TRAC 70 69 68 67 (0R A) 2" BLOW OFF / PER C. O.R. STD DTL 340.1, \ I SEE SHEET C6.32 (TYP) 72f87.77, 8.19' L T 1-8" PLUG (M✓) d•.:;,r ill -- —it 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING 1-8" POL )PIGGING 5TAT/ON PER C.O.R. STD DTL 300.7, til _ SEE SHEET C6.32 70f26.51, 6.00 L T " EX TREE 1-12TEE (FL) 12'W' TEE (FL) TO BE SA VED 1-12" GATE VAL l/E (FLxM✓) 2-12" GATE VAL vE (FLxM✓) (TYP) >->2" ADAPTOR (M✓) 1-12"x8" REDUCER (FL) 1-6" GATE VAL I/E (FLxM✓) 1-8" GATE VAL l/E (FLxM✓) FIRE HYDRANT ASS'Y W/ CONC BLOCK/NG W/ CONC BLOCKING SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. N" EXIS77NG GROUND 0 ROAD (TYP) 38% PROPOSED 12" oWATER � o 70+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ EXISTING ELEV. 0 ROAD � (TYP) - PROPOSED ELEV. 0 ROAD (TYP) 71 +00 GH PT STA: 71f80.15 HIGH PT EL.- 427.11 PW STA.- 71f72.00 PV/ EL: 427.82 ROW 6 HOR/Z. SCALE- 1" 30' VERT. SCA E. 1" 5, 10�2 I N 71+50 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS NONE i 72+00 15' BSBL 440 FILL AND COMPACT ROADWA Y PRISM TO F/N/SHED SUBGRADE PR/OR TO INS TALLAT/ON OF WATER MAINS (TYP/CAL ALL FILL AREAS) � I I PROPOSED GRADE 0 ROAD �' (TYP) �44q PROPOSED 8" WA TERM \ 72+50 0 M J S 7/26/23 HHH SURVEYED: SY OTHERS K E L 9/ 12/23 HHH DESIGNED: ROLL/ HEAVR/N KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N 430 420 410 N 73+00 73+50 SCALE: VERTICAL• NAw lsae AS NOlEO HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON + N Planning/Building/Public Works Dept. FffA WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE I IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLANS 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE 'Con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.07 ROOF, A� 6 SHEET: OF: �/ �/ 55 93