Loading...
HomeMy WebLinkAboutW-425509Z ti O Z O SEE SHEET NOT INSTALLED /�TRACT IV "F" nn, vn,nn,V6 ter. nn., TRACT M V 6. O5 (OPEN SPACE) (OPEN SPACE) ___ _..__. __-_ 9 8 I I 7 6 5 d: PROPERTY LINE 10' U77L/TY EASEMENT (TYP) � I W 8"WATE (G 1 SD CM \ SSCO 436.07' 8" CNC W=435.22 RIM-437.0 ' can IE 12" CNC E=433. ' 00 IE 8" CNC SE=433. ' IE 8" CNC SW=433. ' IE 12" CNC W=433. ' NOT INSTALLED , M W IJ W IJ SEE SHEET PROPOSED STREET C6, O1 LIGHT (TYP) PROPOSED FINISH GRADE CONTOUR 0�� 0HP Q Tom" n"P — — °H SAWCUT (TYP) Q 81*00 8" WATER MAIN (ASBESTOS CEMENT) i NE 12TH ST, ev — SD SD—��D SD - s ` ---- CM 1-8x8" TEE (FL) 3-8" GATE VAL Vf-5 (FLxM✓) 1-8"x12" REDUCER (M✓) 2-8" LONG BODY TRANSITION COUPLINGS (8" AC TO 8" DI) 1-8" SLEEI/E (M✓) W/ CONC BLOCKING FINAL CONNECTION BY CITY FORCES 1-8x8" TEE (FL) 3-8" GATE SAL VES (FLxUJ) 1-8"x12" REDUCER (MJ) 2-8" LONG BODY TRANS177ON COUPLING (8" AC TO 8" DI) 1-8" SLEEVE (M/) W/ CONC BLOCK/NG FINAL CONNECTION BY CITY FORCES TRACT 0 yl 4 (OPEN SPACE) (TYP) 3 2 1 I I PROPERTY LINE I' iN _ •. (TYP) — PROPOSED FIRE HYDRANT — — �- — — -- — PER C. O.R. STD DTL 310.1, 0 s s• N N SEE SHEET C6.31. THIS NEW FIRE HYDRANT WILL BE "• '� " ' — _ _ �� �a t , ... -° - — �,� : . p ; .a . ' i. i — -� -' ; . ' a._ j .., .. ; :. INSTALLED WITH THE CITY •—'..:T C/P PROJECT, AND THE —424_ TOWNS ON 12TH DEI/ELOPER " _ °"P— - W/LL REIMBURSE THE COST P 'o er - OF THE INSTALLATION BY CITY. P ` OH o I z32t00 1 RIM=426.6S IE 8" CNC NF=425.78' EX/STING WA T R METER TO BE /134NOONED Z — —426- 42$ IE 12 CN = w w w— I — IE 12" CNC W=424.44' EX GROUND SD c \ so SD G — CONTOUR (TYP) SD Sp - �il I --SD IM=426.41� / DT E 8" CNC NW=4-25-.-6' M=427.83' �1'S E 12" CNC E=424.93' E 8" CNC SE=425.03' E 8" CNC SW=425.03' E 12" CNC W-425.03' SEE SHEETS C7.02—C7.04 FOR UTILITY CROSSING NFORMAT/ON. NOT INSTALLED 8"x6" TEE (M✓xFL) 1-6" GATE VAL VE (FLxUJ) F/RE HYDRANT ASS'Y 2-8" LONG BODY TRANSITION COUPLING (8" AC TO 8" DI) 1-8" SLEEI/E (M✓) W1 CONC BLOCK/NG M i i 79+50 80+00 80+50 81+00 81+50 82+00 82+50 83+00 83+50 84+00 84+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w SURVEYED: BY OTHERS DESIGNED: HOLL/ HE -A VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HE VR/N BY DATE APPR APPROVED: HOLL/ HE -A VR/N SCALE: 1" = 30' 0 15 30 60 SCALE: VERnCAL• NAVD 1988 AS NOTED HORIZONTAL- NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY i 1 /h M2 WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/STING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425509 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE NE12ST ST CONSTRUCTION RECORD DRA WINGS 00 0 N N V 0 0 0 N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.O8 SHEET: OF: 56 93