HomeMy WebLinkAboutW-425510pp �- CUT --IN.• (BY CITY FORCES) 93f70.55, 19.55 L T gCONNECT TEE FL X WATER Iice 3--12" GATE AL VES (FLxUd) TOP OF NUT 394.85 -P - C L - TOP OF - SLOPE I c (Typ) \\ 15' BUFFER (Ty) PROPERTY LINE (TYP) EX TREE TO BE SA VED (TYP, 370 92+50 eF C 6 Sys �p� '�� p p0 �\''�����5 q� „ c�`c p� co %�oo��c EX GROUND \Y �01 G�c 4� G�P����� CONTOUR (TYP) P P P P - - PP P P P P P P P P P P P EX. 12" GATE VA VE - EX 12 WATER MAIN w 12"WATER (G1) C w w w w w w w w w w w w w w w 12" POL YP/GGING STATION z 12" DI - PER COR STD PLAN NO.. 300.7 SEE WA-1 PROFILE, THIS SHEET 93f00 94f00 N.• 187128.9348 00 96�00� ` 97f00 98f00 9�00 -�-- -�- E.•1310663.5701 ss ss _ ss _ ss ss _ _ 9LF*F12" Dl = 3� 1-12'x45° VERTICAL BEND (R✓) 7LF�tF-12" DI W/ CONC BLOCKING NE SUNSET BL VD PROPOSED STREET / EX OFFS/TE TREE 4LF-* -12" D/ N.• 187121.3525 / LIGHT (TYP) TO REMAIN (TYP) 20LF� 12 Dl E.• 1310658.1103 , , i 2„ M� E� -- - , _- p Uv - P c P C P .W/ CONC BLOCKING ,, P 187115.7893 -------------------------------------------- -- - - - --__ - ___ _----------Jni` �__--- - - - r ----s---_ s- r'� --- ---- - PIPING AND FITTINGS[,416, E. 1310654.1044_- SHALL BERESTRA/NED _--;- 1 12 x45° VERT/CAL BEND (R✓)JOINT BETWEEN CONNECTION 1 �� W/ CONC BL OCK/NGAND BEND.� - 1 � � 410 � ., ---� - -�- /- � I \ \ �� � N.• 187112.7932 �/o � / _ � ,i � � �,`- E.• 1310651.9470 � �� - - �Q -- _ ll \\ -�� _ 420 1-12"x45° VERT/CAL BEND (R✓); ' \ ��=�� - - - �\ i o W CONC BLOCKING - _ 420 - TRACT `(CRITICAL AREA " - Y _ CASING PIPE ^� 76 �%` PER C.O.R. STD DTL 412 BSBL 41LF 12" D/ SEE SHEET C5.31 TRACT) FINISH 77 SEE N.• 18706J 5307 N.- 187096. 5146 PROPOSED TRACT`( SHEET E.• 1310616.4749 E.• 1310640.2254 (STORM DRA/NAGS) GRADE CONTOUR (CRITICAL AREA) 1-12"x45' VERTICAL BEND (Rd)1-12"x45° VERTICAL BEND (RI) �) SEE SHEETS C7. 02-C7. 04 FOR C6, 07 W/ CONC BLOCK/NG W/ CONC BLOCKING >2" D/ UTILITY CROSSING/VFORMA T/O/V. SCALE: 1 " = 3 O' 5LF IF CONNECTION TO THE WATER MAIN /N SUNSET IS MADE PR/OR TO THE EXTENSION OF THE ONS/TE WA TER, DEVfZOPER SHALL EXTEND THE STUB FROM THE EX MAIN SOUTH TO A POINT WHERE /T /S OUTS/DE THE ROW. 93+00 93+50 94+00 94+50 95+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 063 95+50 96+00 N.11207im • 390 370 96+50 430 420 410 390 EX/STING GROUND ® PIPE � (TYP) \ PROPOSED GRADE ® PIPE f (TYP) 12 x45' VERTICAL BEND (R✓) W/ CONC BLOCKING m PROPOSED 12" D/ WATER W/ RESTRA/NED JOINTS (TYP) SLOPE ANCHORS ARE REQUIRED ON WATER MAIN /F GRADE /S A90Vf 209 SEE ANCHOR DETAIL, SHEET C6.32. V \ PROPOSED BLOCK WALL 10' CASING PIPE EX SD n PER COR STD DTL 412, lE 392.60 I SEE SHEET C5.31 12"x45° VER77CAL BEND (R✓) y W/ CONC BLOCKING EX/STING ELEV. ® P/PE � (TYP) WA 1 PROPOSED ELEV. HOR/Z. SCALE- 1'=30' ® P/PE �' (TYP) VERT. SCALE- 1 "=5' 0+50 SURVEYED: BY OTHERS SCALE: AS NOTED DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE ONE INCH CHECKED: HOLL/ HEA VR/N AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE APPR APPROVED: HOLL/ HEA VR/N 0 15 30 60 430 420 410 390 1+00 1+50 VERTICAL* NAVD 1988 HORIZONTAL- NAD 1983/1991 CITY OF F RENTON DATUM Planning/Building/Public Works Dept. -------- WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •D- TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL COIVSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/STING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO COIVS7RUC77ON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓� END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE NE SUNSET BL VD & WA 1 0 O 0 N N Qk N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.09 O) SHEET: OF: 57 93 CONSTRUCTION RECORD DRA WINGS