HomeMy WebLinkAboutW-425510Lr 10 CUT-1N.• (BY CITY FORCES) 0ti 93+70.55, 19.55' L T q� �`� CONNECT TO EX WA TER 1-12" TEE (FL) i 3-12" GATE VAL I/ES (FLxM✓) `k 0 CONC BLOCKING -P P "� P EX. 12" GATE VALVE ' - w 12" POL YP/GGING STATION PER COR STD PLAN N0. 300.7 93f00 CV /1CCC11TC rD= N TOP OF - SLOPE I I - (TYP) 15' BUFFER (Typ) PROPERTY LINE (TYP) EX TREE TO (� BE SA VED (TYP) v 370 IF CONNECTION TO THE WATER MAIN IN SUNSET IS MADE PR/OR TO THE EXTENSION OF THE ONS/TE WA TER, DEVELOPER SHALL EXTEND THE STUB FROM THE EX MAIN SOUTH TO A POINT WHERE /T /S OUTS/DE THE ROW. QF -6 �� %�����c EX GROUND ��%' R �G�P���� �`� �v CONTOUR (TYP) �`�\ c�c ��� . P T,P P r P P r' P P P P P P 12"WATER (G1) EX 12" WATER MAIN w w w w w w w w w w w w w w �r w w w = 32LF 12" DI \19r - - SEE WA-1 PROFILE, THIS SHEET 3y6\ v'9R\ �9?\ 94*00 N.• 187128.9348 .00 96,*, OO��ss � � ss 97400 ss ss � -Ss 98f00 ss � 9�00 L = 3� 1-12'x45° VERI7CAL BEND (Rd) ' i W/ CONC BLOCK/NG NE SUNSET BL VD i i / PROPOSED STREET N' 187121. J525 , LIGHT (TYP) o E.• 1310658.1103 , ' ' i 2" MPEI 1-12 x45° VERTICAL BEND (R✓) W/ CONC BLOCKING " P N. 187115.7893 _ _ -E°• 1310654.1044 41 �1-12"x45° INERT/CAL BEND (R✓) - - -l�W/ CONC BLOCK/NG 416, I \1 �� N.- 187112.7932 QO - \ E' 1310651. 9470 -1-12W5° INERT/CAL BEND (R✓) � -� ` 420 422 - W/ CONC BLOCKING \ 76 - - . CASING P/PE PER C. O.R. STD OTL 4>2, 41LF 12" D/ SEE SHEET C5.31 TRACT) N' 18706J5307 N.• 187096.5146 (STORM DRAINAGE) E' 1310616.4749 E' 1310640.2254 1-12"x45° VERTICAL BEND (R✓) 1-12"x45° INERT/CAL BEND (R✓) W/ CONC BLOCKING W/ CONC BLOCKING 5LF 12" Dl 92+50 93+00 93+50 94+00 94+50 i 95+00 95+50 96+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ �'`•--tee ` `. i�'M 'T �-� �� .. - ------------- � 420 PROPOSED FINISH GRADE CONTOUR (Typ) 390 370 0 96+50 430 420 410 390 71- -_�: - SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. EX/STING GROUND ® PIPE � (TYP) \ PROPOSED GRADE ® PIPE f (TYP) 12 x45' VERTICAL BEND (R✓) W/ CONC BLOCKING m PROPOSED 12" D/ WATER W/ RESTRAINED JOINTS (TYP) SLOPE ANCHORS ARE REQUIRED ON WATER MAIN /F GRADE /S A90Vf 209 SEE ANCHOR DETAIL, SHEET C6.32. V \ PR POSED BLOCK WALL 10' CASING PIPE EX SD PER COR STD DTL 412, lE 392.60 SEE SHEET C5.31 12"x45° VERTICAL BEND (R✓) y W/ CONC BLOCKING EX/STING ELEV. ® P/PE � (TYP) WA 1 PROPOSED ELEV. HOR/Z. SCALE- 1'=30' ® PIPE �' (TYP) VERT. SCALE- 1 "=5' �1 0+50 1 REVISED PER CITY COMMENTS MJS 7/26/23 HHH SURVEYED: BY OTHERS SCALE: AS NOTED 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE ONE INCH CHECKED: ROLL/ HEA VR/N AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE AP P R APPRovED: L/ HE l/R/N ROL 1 +00 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M TRACT H (CRI77CAL AREA) SCALE: 1" = 30' 0 15 30 60 f30 420 410 390 1+50 CITY OF RENTON Planning/Building/Public Works Dept. Kt: YImp WA TER LEGEND WA TER MAIN - - WA TER EASEMENT -------- WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M/) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340. t 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 0 O 0 N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.09 NE SUNSET BL VD & WA 1 SHEET: 57 OF. 93