Loading...
HomeMy WebLinkAboutzW-4255setZ ti O Z O SEE SHEET C6.07 (ROW 6) W --i EX/STING TREE TO BE SA VfD (TYP) SEE SHEET C6.06 - (ROW 5) SEE SHEET 0 05 - UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 (ROW 4) /� CONNECT TO EXISTING WATER SEE SHEET C6.09 (WA-1 PROFILE) SEE SHEET 0 09 (NE SUNSET 8L W) SURVEYED: BY OTHERS DESIGNED: HOLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HEA VR/N APPROVED: HOLL/ HEA VR/N SCALE: SEE SHEET 06.02 (ROAD A STA 15f00-END) SEE SHEET C6.01 (ROAD A START-STA 15*00) TOP OF SLOPE (TYP) 15' BLDG SETBACK (TYP) 15' BUFFER (TYP) A Il�� .5£E SHEET C6.04 (ROW3E-W&N-S) SEE SHEET 06.03 (ROW 1 & ROW 2) EX/STING GROUND CONTOUR (TYP) PROPOSED FINISH GRADE CONTOUR (Typ) PRO✓ECT BOUNDARY (TYP) SEE SHEET 0 08 (NE 1121-H ST) w _426— NE 12TH ST AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL• NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. I N l SCALE: 1" = 50' 0 25 50 100 WA TER LEGEND y IN[ 0 T' WATER MAIN WATER EASEMENT WATER BSBL EX/STING WATER P/PE WATER FITTING FIRE HYDRANT WATER METER TYPE / BLOW -OFF AIR- VAC 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425501 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 COMPOSITE WA TER PLAN 10/111202J PAGE: C6.00 SHEET: OF: 48 93 O O O N N CONSTRUCTION RECORD DRA WINGS Z ti O Z O TRACT H (CR/T/CAL AREA) EX TREE - TO BE SA VED - (TYP) I 10' UTILITY I I EASEMENT (TYP) m n cn = C RO m m -off N � 14*55.58, 5.00' RT 1-12'%8" TEE (FL) 2-12" GATE VALVES (FLxM✓) TOP OF NUT 424.78 TOP OF NUT 424.91 1-8" GATE VAL VE (FLxMJ) TOP OF NUT 424.20 W/ CONC BLOCK/NG ,,, N V430 1", J' W v, Ow 420 Q) VJ vi LQ V Q410 N 12f94.35, 5.00' RT 1-12" CROSS (FL) 2-12" GATE VALVES (FLxM✓) PROPOSED FINISH TOP OF NUT 428.04 GRADE CONTOUR TOP OF NUT 428 OJ (TYP)2-8" GAVE VALVE (FLxM✓) TOP OF NUT 428.14 „r TOP OF NUT 427.50 15' BSBL JCL a7/7LL / C6.06 TOP OF NUT 425.04 FIRE HYDRANT ASS'Y 8TM FLANGE 429.72 W/ CONC BLOCKING STANDARD 1 " WA TER SERVICE PER C. 0.R STD DTL 320.1, SEE SHEET C6.31 (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 11135.29, 5.00' RT 1-12"x8" CROSS (FL) 2-12" GATE VALVE (FLxMJ) FIRE HYDRANT ASS'Y BTM FLANGE 428.83 W/ CONC BLOCK/NG - PROPOSED STREET LIGHT (TYP) SEE SHEET C6.O8 FIRE HYDRANT ASSEMBL Y PER C. O.R STD DTL 310.1, SEE SHEET C6.31 (TYP) EX GROUND CONTOUR (TYP) 3 NOT INSTALLED SCALE: 1 " = 30 L , * 1-8" TEE (FL) 0 15 30 60 3--8" GA TE VAL VES (FLxM✓) 1-8"x12" REDUCER (M✓) 2-8" LONG BODY TRANSITION COUPLING (8" A. C. TO 8" D.l.) 1-8" SLEEI/E (M✓) FINAL CONNECT/ON BY CITY FORCES W/ CONC BLOCK/NG, SEE NOTE 9, THIS SHEET WA TER LEGEND HIGH PT ST I: 12f85.84 HIGH PT I L.• 430.28 LOW PT STA: 10 65.77 PW STA: 13f00. 00 LOW PT EL: 42788 I, PW EL: 430.68 ' o0 00 PW STA: 10*60.00 100.0 12f84.29 ROAD A VC o PV/ EL: 427. 8 0 o PROPOSED GRADE y. = rn 30f 00 ROW J. �. �, o ^'� p 0 50.00 VC Q p 0ROA0 (TYP) r o``, •mod �� EL: 430.28 �W 13 ii oz L STING GROUND � W LE 12f89.35 = ROAD A W 54f59.91 =ROW 4 o m o m PROPOSED 12 WATER (TYP) rn ii r\ W �� �� °� OROAD � (TYP) p ^ EL: 430.28 _ ,�o�, r, o� WW mm o� I o - - - - \ Ao ------------ _2.24q ov 0 0 ' DOWQo= Z �iIOVOV�`I��v w _ p W� Pz � v � ROAD A EX/SANG ELEV. PROPOSED ELEV. HOR/Z. SCALE- 1 "=30' 0 ROAD 0 ROAD f (TYP) VERT. SCALE. ad of O ci ad ad N 15+00 14+50 14+00 13+50 13+00 12+50 12+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 063 11 +50 BY I DATE 11 +00 10+50 10+00 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N AP P R APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM - -- tiF SGti sFT e�G 0 E 12TH ST KEY MAP WATER MAIN WATER EASEMENT WATER BSBL EX/STING WATER PIPE WATER FITTING FIRE HYDRANT WATER METER TYPE / BLOW -OFF AIR- VAC GENERAL NOTES 440 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECAON. 2. ALL CONSTRUCAON SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD SPEC/F/CA77ONS. 3. LOCATIONS OF EX/SANG U77LI77ES SHOWN ARE APPROX/MATE. EX/SANG UAL/T/ES SHALL BE FIELD LOCATED BY RESPEC77VE UALITY COMPANIES PR/OR TO CONSTRUCAON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECAONS TO EX/SANG PIPES 430 FOR PROPER RTANGS AND DEPTH. 5. CONTRACTOR SHALL NOTIFY ALL AFFECTED UTILIAES 24 HOURS PR/OR TO CONS7RUCAON. 6. ALL WATER RTANGS AND VAL VES WITH MECHANICAL JOINT (M✓) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REOU/RED ON ALL WATER RTANGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL 420 LENGTH OF WATER PIPE SHALL BE USED Wl1H THE PIPE CENTERED FOR MAX/MUM JOINT SEPARA AON. 9. IF THE TOWNHOMES PROJECT COMES FIRST, THE PROJECT COULD AE IN ON THE EX/SANG 8" AC WATER MAIN AS SHOWN ON THE PLAN. 10. IF THE TOWNHOMES PROJECT /S BEHIND THE SCHEDULE. THE CITY C/P PROJECT WILL INSTALL THE TWO TEES WITH STUBS TO THE PROPERTY L/NEAT DEVELOPERS COST FOR FUTURE CONNECAONS, AND INSTALL THE FIRE HYDRANT TO THE EAST W/TH/N NE 12TH ST. 410 CITY OF RENTON Planning/Building/Public Works Dept. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425502 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROAD A (START- 15+00) CONSTRUCTION RECORD DRA WINGS 0 0 0 N N �i N ti DATE: O 0/111202J FIELDeo PAGE DRAWING NO: �ijh C6.01 SHEET: OF: 49 93 Z ti O Z O O v PROPOSED FINISH GRADE CONTOUR EX GROUND (TYP) SEE SHEET C6.09 CONTOUR (TYP) 17425.57, 5.00' RT 74 TRACT) 1-12" 45° BEND (M✓) i (STORM DRA/NA GE) W/ CONC BLOCK/NG WA TER EASEMENT (TYP) II \ -sss- 73 I WATER BSBL (TYP) SEE SHEET I J �ao2 �� PROPOSED 17f8217, 5.00 RT 72 � T_- _ Q �\ \ - \\ STREET LIGHT 1-12 /Tf_ (FL) 06. 07 221E I F - . •. --- ___- \9 ` �' ��• (TYP) 2-12 GATE VAL l/E (FLxM✓) 12 DI TOP OF NUT 424.45 TOP OF NUT 424.47 84 -- 0 71 �� P --__ -_- -- I — 1-12"x8" REDUCER FL - I PRERTY LINE ,\ � SCALE: 1 " - 3 O' O - I �o (TYP) 1-8" GATE VAL l/E FLxM✓ • / — �\ �`, �`44 TOP OF NUT 424.12 85 = z 12 D/ W/ CONC BLOCK/NG — — 00 \\ �� \� �" rvy�22 \ . f 15f56.32, 5.00' RT \ D/ 4 1-12 "x22.5° BEND (M✓) o , � W/ CONC BLOCKING > SELF 15 �vv .. �f11.18, 5.28 RT WA TER � T2" D/ \00 ¢�! 12 �� ° — 1- 12"x22.5° BEND M✓ 17f62.51, 5.00' RT - 87 { EASEMENT l a \ — — — ' W/ CONC BLOCK/NG - 12 W TEE (MAR) SEE 70 1-6" GATE VAL I/E (FLxM✓) ° � ;;� � �; . ; s� '� TRACT H, I TOP OF NUT 421.90 SHEET a� ` 'fie. 2��o p (CR/ 17CAL AREA) FIRE HYDRANT ASS Y BTU FLANGE 425.69 69 � — � p. � , W/ CONC BLOCK/NG C6.07 ' �i \ 2 10 UTILITY OO EASEMENT FIRE HYDRANT ASSEMBLY ' 15+ � (TYP) PER C. O.R. STD DTL 310.1, 68 ° SEE SHEET C6.31 (TYP) t 66 63 N � I N C6 0 65 64 I . 62 61 60 ATC E ET 16f96.08, 28.75' L T TRACT M 16142.54, 22.33' L T 5 5EE 1-12" 45-BEND (M✓) (OPEN SPACE) 1-12" 45-BEND (MJ) W/ CONC BLOCK/NG W/ CONC BLOCKING 16f05.7 ,, 5. 00' RT STANDARD I" WATER SERVICE 12"x6" TEE (UJxFL) PER C.O.R. STD DTL 320.1, 16f 15.21, 5.00' RT 1-6" GATE VALVE (FLxM✓) SEE SHEET C6.31 (TYP) 1-12" 45° BEND (M✓) TOP OF NUT 429.75 W/ CONC BLOCKING FIRE HYDRANT ASS'Y BTU FLANGE 429.75 W/ CONC BLOCKING 436 426 416 18+50 18+00 17+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 it 17+00 16+50 16+00 1 440 i PROPOSED ELEV. F 9 ROAD � (TYP) 15+50 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N O 430 v W1v, J' vJ 420 O V, vi 4-4 410 Q SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. KEY MAP WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE—HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓) END(S) SHALL HAKE A WEDGE —TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON —POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425503 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROAD A (15+00 -END) O 0 N N N H DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.02 SHEET: OF: 50 93 CONSTRUCTION RECORD DRA WINGS A Z ti O Z O O v 450 „m 430 420 51f34.97, 7.00' RT 1-12 x8" TEE (FL) SEE SHEET 2-12" GA VE VAL VE (FLxM✓) PROPERTY LINE TOP OF NUT 435.02 (TYP) C6. 05 TOP OF NUT 435.01 I I _ 1-8" GA VE VAL Vf (FLxM✓) TOP OF NUT 434.44 I19 W1 CONC BLOCKING EX I TREE REM TO REMAINN (TYP) ' . A I 23 22 21 - 20 -9174 APN 0423o5 V0 UO PH TRACT M �� _ - = jj (OPEN SPACE) I I 9 8 SEE SHEET TRACT /V (OPEN SPACE) C6.05 WA TER BSBL (TYP) WATER EASEMENT (TYP) 18+00 18+50 19+00 19+50 SEE SHEET 17' C6.01 )77-1 ®1�11117��i1u iA� 10' UTILITY EASEMENT (TYP) Lj 16 15 14 -13 I \ I � \ f. r1.7- r-.o. ., l '7-A- F N■ R/ I I 1 1 • N IH a N. I I l RESTRAINED JOINT - PIPING f' oo 42 69 TRACT 0 7 6 5 I (OPEN SPACE) 4 3 Fr RESTRAINED SEE SHEET 20*05. 00, 6. 00' RT JOINT 1-12"x8" CROSS (FL) 19f42.64, 3. 00' RT PIPING C6. 01 2-12 GATE VALVE (FLxM✓) 1-11.25° BEND (M✓) TOP OF NUT 425.99 W1 CONC BLOCK/NG TOP OF NUT 426.03 2-8" GATE VAL Vf-5 (FLxM✓) 19f57.73, 6.00' RT TOP OF NUT 425.35 1-11.25° BEND (M✓) TOP OF NUT 425.43 W1 CONC BLOCKING W1 CONC BLOCK/NG 20+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 063 450 430 420 20+50 „m t1211 1 " WA TER SERVICE STD DTL 320.1 PROPERTY LINE C6.31 (TYP) (TYP) 15 EX GROUND CONTOUR (TYP) 10 21*76.51, 6.00'RT I 1-8" PLUG (M✓) 1-2" BLOW -OFF ASS? W1 CONC BLOCK/NG I 1-8" POL YP/GG/NG STATION TZE PER COR STD. PLAN NO. 300.7 PLf 80 DI I 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) ln�1 3p5,9235 _LC APN 04ASSpCIPTE ID ALP AY & PROPOSED FIMSH m GRADE CONTOUR 2 1 m j l (TYP) WA TER EASEMENT (TYP) WATER BSBL (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: 1" = 30' 0 15 30 60 . . . . . . . . mo�O h^ W W°j� o Q PROPOSED GRADE s N W 9 ROAD f (TYP) . � OPOSED 8" I In 1 TER (TYP) W N O N "� o EX/STING GROUND 9 ROAD (TYP) . Q . • . ^� v . v . . Q . . . . . . . . . . . . . . . . . . o . I O j . . . . . . . . . . PROPOSED ELEV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ROAD f (TYP) �ZC EX/SANG ELEV. HOR E.• 1 "=30' 9 ROAD f (TYP) VERT. SCA E.• 1 "5' 20+00 20+50 21+00 SURVEYED: BY OTHERS DESIGNED: HOLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HEA VR/N BY DATE APPR APPROVED: HOLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY tiF sFT e�G 0 NE 92TH ST `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 440 1. MAX/MUM ALLOWABLE DEFLECION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS 3. LOCA77ONS OF EX/STING U77LI77ES SHOWN ARE APPROX/MATE. EX/SANG U77LI77ES SHALL BE FIELD LOCATED BY RESPECT VE UALITY COMPANIES PR/OR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EX/SANG PIPES 430 FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77LI77ES 24 HOURS PR/OR TO CONSTRUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE BETA/NER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL 420 LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAX/MUM JOINT SEPARA AON. 410 21+50 22+00 22+50 VERnCAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 CITY OF RENTON DATUM Planning/Building/Public Works Dept. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROW 1 & ROW 2 CONSTRUCTION RECORD DRA WINGS O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.03 SHEET: OF: 51 93 i Z ti O Z O O O v v o 0 430 \- 420 410 .30f05.00, 10.00' L T 1-12" CROSS (FL) 3-12" GATE VAL Vf-5 (FLxMJ) TOP OF NUT 428.04 TOP OF NUT 428.03 SEE SHEET C6.01 1-12'x8" REDUCER (FL) 108LF 12" DI 1-8" GA Vf- VAL Vf- (FLxMJ) TOP OF NUT 428.14 TOP OF NUT 42750 TOP OF SLOPE (TYP) TRACTH I Bs�l PROPOSED FINISH GRADE CONTOUR (TYP) WATER L/NE WITHIN ROW 3 REMOI/ED WATER SERVICES TO LOTS 38-39 REM01/ED EX TREE TO BE SA VfD TRACT C (Typ) TRACT G \ I _ 44 (OPEN SPACE) W1 CONC BLOCK/NG 173LF 12" DI WA TER BSBL (TYP) RESTRAINED I JOINT PIPING II o 1I 45 i I 46 I t / 8" DI WA TER EASEMENT (TYP) o WNI INF-� 8)p DI 42 O _ 8„ DI I I PROPERTY L/NE Qj , C� 00 s, I t (TYP) W v fOW 3 N i t /I 4. m 3" PLUG (MJ)W 75.50, 6.00' L T 1-81 TOP OF PIPE 421.95 30 1\ � 31 32 _ 33 34 35 36 37 I \ '1-2» BLOW -OFF ASS'Y .W/ CONC BLOCKING IL- c"Ncl ' - /15 1-8" POLYP/GG/NG STATION STD PLAN 300.7 PE CORj I D (M✓) C.O.R. 30f22.01, 9.97' L T 30f36.80, 6.00' L T » SEE SHEET STANDARD 1 WATER SERVICE EX GROUND 1-22. 1-22.5°BEN 5° BEND NJ) PER STD DTL 320.1, CONTOUR (TYP) TOP OF PIPE 425.75 C6, 01 TOP OF PIPE EN 425.68 SEE SHEET C6.31 (TYP) W1 CONC BLOCKING W1 CONC BLOCK/NG 10' UTILITY EASEMENT (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMA TION. N PROPOSED GRADE q 0 ROAD (TYP) u hn� N ROP 95E9 8" - WA R (TYP ■ EX/STING GROUND 0 ROAD f (TYP) -¢009' PROPOSED ELEV. ® ROAD (Typ) ROW 3 (E ST-WEST EX/S77NG ELEV. HOR/Z. SCALE. 1 "=30' 0 ROAD �' (TYP) VERT. SCA E. 1 =5' � 30+00 30+50 31f00 31+50 40 41 42 - ASPHAL T THICKENED EDGE TO BE ADDED TO END OF ROW 3, TO DIRECT DRAINAGE TO CB 21 J1*7560 = ROW 3 -EL: 424.58 END ROD IMPROVEMENT 32+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 063 440 440 430 430 420 420 410 410 32+50 :120 • N A SCALE: 1" = 30' 0 15 30 60 h 3� PROPOSED GRADE 0 0 ROAD f (TYP) II 3� n EX/STING GROUND oo GRADE BREAK n 0 ROAD (TYP) o 41 f29.55 1.137" EL: 429.13 1 PROPOSED ELEV. 0 ROAD (TYP) RO 3 (NORTH -SOUTH) EX/STING ELEV HOR/Z. SCALE- 1 "30' 0 ROAD �' (TYP) INERT. SCALE- 1 "5' 40+00 40+50 41f00 SURVEYED: BY 07NERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HEA VR/N BY DATE APPR ROLL/ HE -A l/R/N SCALE: AS NOIED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 41 f50 VERTICAL* NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM 430 410 42+00 CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN — — WA TER EASEMENT -------- WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/S77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE UTILITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EX/S7TNG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUC770N. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425505 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROW3(E-W&N-S) O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.04 SHEET: OF: 52 93 CONSTRUCTION RECORD DRA WINGS Z ti O Z O O v 450 R 430 420 N N 55+00 54+50 SEE SHEET C6.04 54f64.91, 4.94 L T 44= 45 1 a:_ . 31 n 1 12 CROSS (FL) I � 3-12" GATE VAL VfS (FLxM✓) TOP OF NUT 428.04 TOP OF NUT 428.14 i� TOP OF NUT 428.03 � � 1-12'x8" REDUCER (FL) ill 1-8" GAVE- VALVE- (FLxM✓) TOP OF NUT 427.50 — 12 DI W/ CONC BLOCK/NG W v ROA A 13f 46LF RESTRAINED JOINT PIPING TO THE END OF THE STORM LINE DUE TO NON -CONFORMING 46 - HORIZONTAL SEPARA 77ON 47 54+00 48 i 49 WA TER EASEMENT (TYP) 50 51 52f9.3.96, 7.49' L T 1-12"x45° BEND (M✓)7'_�52 W/ CONC BLOCK/NG 23LF 1211 52f73.83, 0.20' L T 1-12 x45° BEND (MJ) - `= W/ CONC BLOCK/NG 15, BSBL TRACT L\ (CRI T/CAL AREA) 53+50 LQ 12 DI W +_ Wv STANDARD I" WA TER SERVICE Y130 PER C.O.R. STD DTL 320.1, SEE SHEET C6.31 (TYP) RESTRAINED JOINT PIPING WHERE STORM /S CLOSER THAN 10.' HORIZONTAL TO WATER 29 MAIN ONLY NEEDS TO GO 10' PAST THE STORM ON EACH END. FIRE HYDRANT ASSEMBL Y L28 PER C.O.R. STD DTL 310.1, SEE SHEET C6.31 (TYP) 52*06.85, 7.00' RT _ — 12'W' TEE (M✓xFL) 1-6" GATE VAL Vf- (FLxM✓) 41* I 27 TOP OF NUT 433X FIRE HYDRANT ASS'Y ' BTM FLANGE 437.22 y: W/ CONC BLOCK/NG 4 7\ 26 TRACTA SEE SHEET (ACCESS & UTILITY) C6.03 25 2211 9 24 23 :. o � 66LF 6& 12" DI �a 72LF 426F 12" DI � iN 144,CF444F 12 " D 52f0�_ _ — — BSBL 1 RQW 4 /TRACT M ` (OPEN SPACE) 53+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 EX TREE TO BE SA VED M (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 51f34.97, 7.00' RT 1-12'x8" TEE (FL) 10' UTILITY EASEMENT 2-12" GA Vf- VAL Vf- (FLxM✓) (T ) TOP OF NUT 435.02 TOP OF NUT 435.01 PROPOSED STREET 1-8" GAVE VALVE (FLxM✓) LIGHT (TYP) TOP OF NUT 434° 44 W/ CONC BLOCK/NG SEE SHEET SCALE: 1" = 30' 0 15 30 60 WA TER EASEMENT C6. 08 EX GROUND CONTOUR (TYP) Q NOT INSTALLED WATER BSBL (TT) I R TRA T N - SPACE) ,3-8" GATE SAL VfS (FLxM✓) 436� 15 I o0 >->2"x8" REDUCER (M✓) •I °.. W - 2-8" LONG BODY TRANSITION HIM- COUPLING (8" AC TO 8" DI) N FINAL CONNECTION BY CITY FORCES 1. 00 W/ CONC BLOCKING 1 (j) _ 19" tq VO,/V� 9;4 TY/lA/ NOT INSTALLED � z , 1 0� S cc 9uFC4 6 zo �o PROPERTY L/NE J I" L A MOSCA Pf (TYP) IRR/GA77ON METER AND `n ` RESTRAINED - DCVA PER COR STD PLAN no PROPOSED FINISH JOINT PIPING �<_ , SEE LANDSCAPE PLAN C o GRADE CONTOUR M 340 8 L 4.03 (Typ) CCC CLJ=7- 11�4_- n c3 52+50 52+00 51 +50 51 +00 50+50 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: )VARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N 50+00 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M ii/ "TA X CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE I BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. S7D PLANS 330.2 AND 330.3. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425506 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROW 4 CONSTRUCTION RECORD DRA WINGS O O N N N ODATE: 0/111202J FIELDeo PAGE DRAWING NO: C6.05 SHEET: OF: 53 93 Z ti O Z O O v TRACT M (OPEN SPACE) 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 66 EX GROUND CONTOUR (TYP) �. 8" POL YP/GG/NG I N I STATION PER COR ° STD. PLAN NO.. 300.7 EX TREE TO BE SA I/ED (TYP) Z2 \ e a 15' BSBL Em 430 420 410 65 � 64 � 63 51f77.31, 6.00' RT 1-8" PLUG (M✓) 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING u 91=11�311119 50*49.44, 5.60' RT 1-8"x11.25' BEND (M✓) W/ CONC BLOCK/NG 62 61 60�0 WA TER EASEMENT (TYP) \ WATER BSBL (TYP) \\r4'2 (TYP) . RESTRAINED JOINT PIPING �� J / TRACT L - �1 �053� 54 55 56 R (CRI T/CAL AREA) STANDARD 1 " WA TER SERVICE PER C.O.R. STD DTL 320.1, SEE SHEET C6.31 (TYP) 52+50 52+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w 51 +50 i Lllmv®II� mm SEESHEET C6.02 Q\ 0 58 59 E 10' U7/L/TY EASEMENT (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. N.11207im • 51 +00 50+50 TRACT) (STORM DRAINAGE) 49f 95.00, 6.00' RT 1-12x8" TEE (FL) 1-8" GATE VAL Vf (FLxU I) TOP OF NUT 424.20 2-12" GATE VALVES (FLxUd) TOP OF NUT 424.78 TOP OF NUT 424.91 W/ CONC BLOCKING GRADE CONTOUR (TYP) SEESHEET C6.01 50+00 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N Eml 430 420 1 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. 0 `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓� END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W 425507 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE Row 5 CONSTRUCTION RECORD DRA WINGS O O N M N v O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.06 SHEET: OF: 54 93 O v PROPOSED FIRE HYDRANT EX GROUND PER C. O.R. STD DTL J10.1, CONTOUR (TYP) SEE SHEET C6. J1 EX OFFS/TE TREE STANDARD 1 " WA TER SERVICE SEE SHEET PROPOSED FINISH PROPERTY L/NE TO REMAIN (TYP) PER C.O.R. STD DTL 320.1, GRADE CONTOUR (TYP) SEE SHEET C6.31 (TYP) C6.02 (TYP) SEE WA-1 PROF/LE, 76 � 75 � 74 73 72 71 7 SHEET C6.09 ` • �j / /�, WATER SETBACK (TYP) -A�f 69 68 67 70f 19.82 6.00' L T WATER T (TYP) EA 1-12 x45° BEND (FLxM✓)(R✓) W/ CONC BLOCK/NG - ��� , �' � 0 �BEF 1 " D/ RJ 71f00 N� w 'iris 72f �F '" (R✓ TRACTK�� -� (CRITICAL AREA),41, TOP OF SLOPE 7 �78 79 80 81 82 83 84 85 86 87 88 - 89 90 15' SETBACK 7LF (TYP) �� 70f26.51, 6.00' L T 7t�12 D/ 12'W TEE (FL) , 71f67. 00, 8.50 L T 1-12" GATE VAL Vf- (FLxM✓) 1-12" TEE (FL) TOP OF NUT 420.84 2-12" GATE VAL VE (FLxM✓) 1- 12 "ADAPTOR (M✓) TOP OF NUT 424.45 1-6" GATE VAL VE (FLxM✓) TOP OF NUT 424.47 TOP OF NUT 420.00 1-12"x8" REDUCER (FL) F/RE HYDRANT ASS'Y 1-8" GATE VAL VE (FLxM✓) 87M FLANGE 4062 TOP OF NUT 424.12 W/ CONC BLOCK/NG W/ CONC BLOCKING SEE SHEETS C7. 02-CZ 04 FOR UTILITY CROSSING NFORMA T/ON. 440 HIGH PT STA: 71f80.15 HIGH PT EL.• 427.11 PW STA.- 71f72.00 PW EL: 427.82 100.00 VC 0 0 EX/STING GROUND 0 ROAD � (TYP) mm L14� 430 Or BEGIN 70f00 = ROW 6 EL: 422.00 ?OAD IMPROVEMENT \ / 3.38 _ o \ PROPOSED 12" '- WATER \ i Z m � 0 J EXISTING ELEV. 0 ROAD (TYP) RO 6 PROPOSED ELEV. 0 ROAD f (TYP) HOR/Z. SC VERT. SC E. I" J0, E. 1" 5' 5382 FNC @ AP FNC @ AP 53 t.000 so@ e TRACT M (OPEN SPACE) TRACT L (CRITICAL AREA) 2" BLOW OFF / PER C.O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 72187.77, 8.19' L T ' 1-8" PLUG (M✓) 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING 1-8" POL YP/GG/NG STATION PER C.O.R. STD DTL 300.7, SEE SHEET C6.32 "�EEX TREE J 15' BSBL TO BE SA VED (TYP) 440 FILL AND COMPACT ROADWA Y PRISM TO F/N/SHED SUBGRADE PR/OR TO INS TALLAT/ON OF WATER MAINS (TYP/CAL ALL FILL AREAS) 1-- 1 1 II PROPOSED GRADE 0 ROAD � (TYP) Qo N L244-r `��'�W PROPOSED 8" WA TERM \ o 70+00 70+50 71 +00 71 +50 72+00 72+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w N.110m • 0 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR ROLL/ HEA l/R/N 73+00 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 430 420 410 73+50 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN - - WA TER EASEMENT - - - - - - - - WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING AK FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. J LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLANS 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/8/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE ROW 6 O O O N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.07 SHEET: OF: 55 93 CONSTRUCTION RECORD DRA WINGS Z ti O Z O SEE SHEET NOT INSTALLED /�TRACT IV "F" nn, vn,nn,V6 ter. nn., TRACT M V 6. O5 (OPEN SPACE) (OPEN SPACE) ___ _..__. __-_ 9 8 I I 7 6 5 d: PROPERTY LINE 10' U77L/TY EASEMENT (TYP) � I W 8"WATE (G 1 SD CM \ SSCO 436.07' 8" CNC W=435.22 RIM-437.0 ' can IE 12" CNC E=433. ' 00 IE 8" CNC SE=433. ' IE 8" CNC SW=433. ' IE 12" CNC W=433. ' NOT INSTALLED , M W IJ W IJ SEE SHEET PROPOSED STREET C6, O1 LIGHT (TYP) PROPOSED FINISH GRADE CONTOUR 0�� 0HP Q Tom" n"P — — °H SAWCUT (TYP) Q 81*00 8" WATER MAIN (ASBESTOS CEMENT) i NE 12TH ST, ev — SD SD—��D SD - s ` ---- CM 1-8x8" TEE (FL) 3-8" GATE VAL Vf-5 (FLxM✓) 1-8"x12" REDUCER (M✓) 2-8" LONG BODY TRANSITION COUPLINGS (8" AC TO 8" DI) 1-8" SLEEI/E (M✓) W/ CONC BLOCKING FINAL CONNECTION BY CITY FORCES 1-8x8" TEE (FL) 3-8" GATE SAL VES (FLxUJ) 1-8"x12" REDUCER (MJ) 2-8" LONG BODY TRANS177ON COUPLING (8" AC TO 8" DI) 1-8" SLEEVE (M/) W/ CONC BLOCK/NG FINAL CONNECTION BY CITY FORCES TRACT 0 yl 4 (OPEN SPACE) (TYP) 3 2 1 I I PROPERTY LINE I' iN _ •. (TYP) — PROPOSED FIRE HYDRANT — — �- — — -- — PER C. O.R. STD DTL 310.1, 0 s s• N N SEE SHEET C6.31. THIS NEW FIRE HYDRANT WILL BE "• '� " ' — _ _ �� �a t , ... -° - — �,� : . p ; .a . ' i. i — -� -' ; . ' a._ j .., .. ; :. INSTALLED WITH THE CITY •—'..:T C/P PROJECT, AND THE —424_ TOWNS ON 12TH DEI/ELOPER " _ °"P— - W/LL REIMBURSE THE COST P 'o er - OF THE INSTALLATION BY CITY. P ` OH o I z32t00 1 RIM=426.6S IE 8" CNC NF=425.78' EX/STING WA T R METER TO BE /134NOONED Z — —426- 42$ IE 12 CN = w w w— I — IE 12" CNC W=424.44' EX GROUND SD c \ so SD G — CONTOUR (TYP) SD Sp - �il I --SD IM=426.41� / DT E 8" CNC NW=4-25-.-6' M=427.83' �1'S E 12" CNC E=424.93' E 8" CNC SE=425.03' E 8" CNC SW=425.03' E 12" CNC W-425.03' SEE SHEETS C7.02—C7.04 FOR UTILITY CROSSING NFORMAT/ON. NOT INSTALLED 8"x6" TEE (M✓xFL) 1-6" GATE VAL VE (FLxUJ) F/RE HYDRANT ASS'Y 2-8" LONG BODY TRANSITION COUPLING (8" AC TO 8" DI) 1-8" SLEEI/E (M✓) W1 CONC BLOCK/NG M i i 79+50 80+00 80+50 81+00 81+50 82+00 82+50 83+00 83+50 84+00 84+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 w SURVEYED: BY OTHERS DESIGNED: HOLL/ HE -A VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HE VR/N BY DATE APPR APPROVED: HOLL/ HE -A VR/N SCALE: 1" = 30' 0 15 30 60 SCALE: VERnCAL• NAVD 1988 AS NOTED HORIZONTAL- NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY i 1 /h M2 WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/STING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425509 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE NE12ST ST CONSTRUCTION RECORD DRA WINGS 00 0 N N V 0 0 0 N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.O8 SHEET: OF: 56 93 pp �- CUT --IN.• (BY CITY FORCES) 93f70.55, 19.55 L T gCONNECT TEE FL X WATER Iice 3--12" GATE AL VES (FLxUd) TOP OF NUT 394.85 -P - C L - TOP OF - SLOPE I c (Typ) \\ 15' BUFFER (Ty) PROPERTY LINE (TYP) EX TREE TO BE SA VED (TYP, 370 92+50 eF C 6 Sys �p� '�� p p0 �\''�����5 q� „ c�`c p� co %�oo��c EX GROUND \Y �01 G�c 4� G�P����� CONTOUR (TYP) P P P P - - PP P P P P P P P P P P P EX. 12" GATE VA VE - EX 12 WATER MAIN w 12"WATER (G1) C w w w w w w w w w w w w w w w 12" POL YP/GGING STATION z 12" DI - PER COR STD PLAN NO.. 300.7 SEE WA-1 PROFILE, THIS SHEET 93f00 94f00 N.• 187128.9348 00 96�00� ` 97f00 98f00 9�00 -�-- -�- E.•1310663.5701 ss ss _ ss _ ss ss _ _ 9LF*F12" Dl = 3� 1-12'x45° VERTICAL BEND (R✓) 7LF�tF-12" DI W/ CONC BLOCKING NE SUNSET BL VD PROPOSED STREET / EX OFFS/TE TREE 4LF-* -12" D/ N.• 187121.3525 / LIGHT (TYP) TO REMAIN (TYP) 20LF� 12 Dl E.• 1310658.1103 , , i 2„ M� E� -- - , _- p Uv - P c P C P .W/ CONC BLOCKING ,, P 187115.7893 -------------------------------------------- -- - - - --__ - ___ _----------Jni` �__--- - - - r ----s---_ s- r'� --- ---- - PIPING AND FITTINGS[,416, E. 1310654.1044_- SHALL BERESTRA/NED _--;- 1 12 x45° VERT/CAL BEND (R✓)JOINT BETWEEN CONNECTION 1 �� W/ CONC BL OCK/NGAND BEND.� - 1 � � 410 � ., ---� - -�- /- � I \ \ �� � N.• 187112.7932 �/o � / _ � ,i � � �,`- E.• 1310651.9470 � �� - - �Q -- _ ll \\ -�� _ 420 1-12"x45° VERT/CAL BEND (R✓); ' \ ��=�� - - - �\ i o W CONC BLOCKING - _ 420 - TRACT `(CRITICAL AREA " - Y _ CASING PIPE ^� 76 �%` PER C.O.R. STD DTL 412 BSBL 41LF 12" D/ SEE SHEET C5.31 TRACT) FINISH 77 SEE N.• 18706J 5307 N.- 187096. 5146 PROPOSED TRACT`( SHEET E.• 1310616.4749 E.• 1310640.2254 (STORM DRA/NAGS) GRADE CONTOUR (CRITICAL AREA) 1-12"x45' VERTICAL BEND (Rd)1-12"x45° VERTICAL BEND (RI) �) SEE SHEETS C7. 02-C7. 04 FOR C6, 07 W/ CONC BLOCK/NG W/ CONC BLOCKING >2" D/ UTILITY CROSSING/VFORMA T/O/V. SCALE: 1 " = 3 O' 5LF IF CONNECTION TO THE WATER MAIN /N SUNSET IS MADE PR/OR TO THE EXTENSION OF THE ONS/TE WA TER, DEVfZOPER SHALL EXTEND THE STUB FROM THE EX MAIN SOUTH TO A POINT WHERE /T /S OUTS/DE THE ROW. 93+00 93+50 94+00 94+50 95+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 063 95+50 96+00 N.11207im • 390 370 96+50 430 420 410 390 EX/STING GROUND ® PIPE � (TYP) \ PROPOSED GRADE ® PIPE f (TYP) 12 x45' VERTICAL BEND (R✓) W/ CONC BLOCKING m PROPOSED 12" D/ WATER W/ RESTRA/NED JOINTS (TYP) SLOPE ANCHORS ARE REQUIRED ON WATER MAIN /F GRADE /S A90Vf 209 SEE ANCHOR DETAIL, SHEET C6.32. V \ PROPOSED BLOCK WALL 10' CASING PIPE EX SD n PER COR STD DTL 412, lE 392.60 I SEE SHEET C5.31 12"x45° VER77CAL BEND (R✓) y W/ CONC BLOCKING EX/STING ELEV. ® P/PE � (TYP) WA 1 PROPOSED ELEV. HOR/Z. SCALE- 1'=30' ® P/PE �' (TYP) VERT. SCALE- 1 "=5' 0+50 SURVEYED: BY OTHERS SCALE: AS NOTED DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE ONE INCH CHECKED: HOLL/ HEA VR/N AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY BY DATE APPR APPROVED: HOLL/ HEA VR/N 0 15 30 60 430 420 410 390 1+00 1+50 VERTICAL* NAVD 1988 HORIZONTAL- NAD 1983/1991 CITY OF F RENTON DATUM Planning/Building/Public Works Dept. -------- WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •D- TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL COIVSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/STING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO COIVS7RUC77ON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓� END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROFILE NE SUNSET BL VD & WA 1 0 O 0 N N Qk N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.09 O) SHEET: OF: 57 93 CONSTRUCTION RECORD DRA WINGS !r TESTING CONNECTION N EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (M1xFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG N (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY rWITH TEMPORARY THRUST BLOCKING DI WATER MAIN } a TEMPORARY BLOCKING CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (FLxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (3) GATE VALVES (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 N O FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, O AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) 0 (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) Ain a a o oOo NEW DI WATER MAIN �M d 0 NOTES: r ` 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3. COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE STD. PLAN - 300.3 .• PUBLIC WORKS CONNECTION TO WATER MAIN APPROVED: DEPARTMENT CUT -IN TEE AND THREE VALVES 6/28/2023 Martin Paztucha DATE P"Dhc W.,w nemmisvm« VALVE BOX AND LID SECTION A -A c 8" TO 12' MATERIALS MAIN TWO-PIECE VALVE BOX WITH REGULAR BASE SECTION TO FIT AND STANDARD 8" OA VALVE BOX TOP SECTION, OLYMPIC FOUNDRY INC 940 OR RICH #045 (NON -LOCKING) COVER TO MATCH VALVE BOX MANUFACTURER, TO READ "WATER", OB VALVE BOX LID WITH EARS IN DIRECTION OF WATER MAIN 8" THICK HMA FOR VALVE IN PAVED OC HMA COLLAR AREA OR 3'x3'x6" CONCRETE PAD IN UNPAVED AREA OOPERATING SEE DETAIL, THIS SHEET NUT EXTENSION WHITE MARKER POST WITH ANCHOR BARB AND BLUE LABEL TO READ OE MARKER POST "WATER", CARSONITE UTILITY MARKER CRM3-066-08 OR EQUAL VALVE OPERATING NUT EXTENSION 2" SQUARE OPERATING NUT 4Y4" DIAMETER 1/8" MIN THICKNESS IETER STEEL, I AS REQUIRED y/ %g 1vn1v 1 n1l.Rlvt» 7 21/4" INSIDE MEASUREMENT 21/4" DEPTH NOTES: 1. EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN 3' BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF V LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. 2. ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, WITH ANTICORROSION COATING CONFORMING TO AWWA C210 VALVE MARKER POST i 34�v NOTES 1. VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS. 2. DISTANCE TO VALVE SHALL BE NEATLY STENCILED ON THE POST WITH 2" NUMERALS. VALVE BOX, PUBLIC WORKS DEPARTMENT OPERATING NUT EXTENSION, AND MARKER POST STD. PLAN - 330.7 Martin Pastutha DATE PUDIic Works Aaminisvat« IyU 1 tzl�: 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. OA HYDRANT OB TEE OC VALVE OD VALVE BOX OE PIPE O JOINT RESTRAINT OG GRAVEL OH CONCRETE BLOCK OI BLOCKING JO SHEAR BLOCK O PAVEMENT MARKER COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 Y4" MVO, 1 Y4" PENTAGON OPERATING NUT, TWO (2) 2 Y2" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET 6" GATE VALVE (FLxMJ) VALVE BOX AND LID PER STD PLAN 330.7 CLASS 52 DI, LENGTH TO FIT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING OR (2) 3/4" CORTEN STEEL TIE RODS 1 Y4" WASHED DRAIN ROCK, MINIMUM V ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANTAND GATE VALVE CONCRETE BLOCKING PER STD PLAN 330.1 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 PUBLIC WORKS APPROVED: DEPARTMENT FIRE HYDRANT ASSEMBLY 6/28/2022 rtmP Publlc Works Administrator DATE 90° BEND CAP / PLUG 45° BEND 2212o BEND B ID 7;7 ox TEE 11 Y40 BEND MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) PIPE SIZE PR(PS) O O O O O 4' 200 2/(1) 1/(NONE) 1/(NONE) NONE NONE 300 3/(2) 2/(2) 2/(1) 1/(1) NONE 6 200 4/(3) 3/(2) 3/(1) 1/(1) 1/(NONE) 300 6/(4) 4/(3) 3/(2) 2/(1) 1/(NONE) 8 200 7/(5) 5/(3) 4/(3) 2/(2) 1/(1) 300 11/(8) 8/(5) 6/(4) 3/(2) 2/(1) 10" 200 11/(8) 8/(6) 6/(4) 3/(2) 2/(1) 275 16/(11) 11/(7) 9/(6) 5/(3) 3/(2) 12" 200 16/(11) 11/(8) 9/(6) 5/(3) 3/(2) 250 24/(16) 17/(11) 13/(9) 7/(5) 4/(3) 14" 200 22/(13) 16/(11) 12/(8) 6/(4) 3/(2) 250 33/(22) 23/(16) 18/(12) 9/(6) 5/(3) 16" 200 29/(19) 21/(14) 16/(11) 8/(6) 5/(3) 225 32/(21) 23/(16) 17/(12) 9/(6) 5/(3) 18" 200 36/(24) 26/(17) 20/(13) 10/(7) 5/(4) 20" 200 45/(29) 32/(21) 24/(16) 13/(8) 7/(4) 24" 200 64/(43) 46/(30) 35/(23) 18/(12) 9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE MUCK OR PEAT SOFT CLAY SAND SAND AND GRAVEL CEMENTED WITH CLAY HARD SHALE SAFE BEARING LOAD 0 1,000 2,000 3,000 4,000 10,000 NOTES: 1. MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. 2. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. 3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. 4. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMITTAKING UP OR DISMANTLING JOINT. 5. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 7. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 8. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.1 ,• PUBLIC WORKS CONCRETE BLOCKING APPROVED: 9�1E DEPARTMENT FOR HORIZONTAL FITTINGS 6/28/2( Martin Pastucha DATE Publlc Works Adminirtrator UNDERGROUND LOCATOR SERVICE CALL BEFORE )I ./ )IOU DIG 811 NO. REVISION 11 Y4° AND 22 Y2 ° BENDS FPIPE CLAMP AND ANCHOR ROD L L v oo A " e �A 45° BEND FPIPE CLAMP AND ANCHOR ROD L'' o o� o � oo D A A PIPE SIZE BEND MINIMUM DIMENSIONS VOLUME (CF) A D L 111/4° 8 2.0' 1/4" 1.5' 4" 221/2 11 2.2' 3/4' 2.0' 45' 30 3.1' 6" 11 %4° 11 2.2' 3/a' 2.0' 221/Z 25 2.9' 45° 68 4.1' 8" 11 Y4 16 2.5' 3/a 2.0' 22 Yi 47 3.6' 45° 123 5.0' 12" 11 Y4 32 3.2' 3/a' 2.0' 22 Yz 88 4.5' 3.0' 45' 232 6.1' 2.5' 11 %* 70 4.1' 1" 3.0' 16" 22 YZ 184 5.7' 11/$' 4.0' 45° 478 7.8' 20" 11 Y4 91 4.5' 11/4" 3.0' 22 Yz° 225 6.1' 4.0' 45" 560 8.2' 11 Y4 128 5.0' 1 Y4" 3.5' 24" 22 Yz 320 6.8' 13/$tr 4.5' 45' 820 9.4' * D = ANCHOR ROD DIAMETER NOTES: 1. CONCRETE BLOCKING SIZES BASED ON 200 PSI HYDROSTATIC PRESSURE AND 3,000 PSI CONCRETE. 2. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 3. PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4. FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 5. WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM 3' COVER. 6. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.2 PUBLIC WORKS CONCRETE BLOCKING APPROVED: DEPARTMENT FOR VERTICAL FITTINGS 6/28/202' Mara. P- h. DATE Publlc Works Aaminisvac« SURVEYED: 8Y OTHERS DESIGNED: HOLLI HEA VRIN DRAWN: MARY U00RE CHECKED: HOLLI HEA VRIN BY DATE APPR APPROVED: HOLLI HEA VRIN SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 19W HORIZONTAL- NAD 1983/1991 DATUM L LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER MATERIALS U CORPORATION STOP OB TUBING OC METER SETTER OD WATER METER O METER BOX O COUPLER AND PLUG O GRAVEL • CITY OF RENTON Planning/Building/Public Works Dept. w Z J F IN UNIMPROVED ROW, w INSTALL METER BOX p AT PROPERTY LINE WITH a 1" COPPER TAILPIECE SIDEWALK w Z J F w CITY PRIVATE o a PIPING PIPING i 21" TO 30" 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ 1" TYPE "K" SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BYTHE CITY METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ "RENTON WATER" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE 1 Y4" WASHED GRAVEL PUBLIC WORKS DEPARTMENT 1" WATER SERVICE STD. PLAN - 320.1 6/28/2023 DATE 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE 'Con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425511 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER STANDARD DETAILS O O O N N DATE: O 1011112023 i7LDBOOK: PAGE DRAWING NO: C6.31 SHEET: OF: 58 93 CONSTRUCTION RECORD DRA WINGS Z ti O Z O M v m PROFILE MATERIALS OA TEE MAIN LINE TEE WITH 4" SIDE OUTLET (MJxFL) WITH PLUG (MJ) 4" GATE VALVE WITH 2" SQUARE OPERATING NUT AND VALVE OPERATING NUT EXTENSION AS REQUIRED OB GATE VALVE PER STD PLAN 330.1 OC VALVE BOX AND LID VALVE BOX AND LID PER STD PLAN 330.8 OD FLANGE 4"x2" TAPPED FLANGE (FLxFIPT) OE PIPE 2" BRASS OR BRONZE NIPPLE, LENGTH TO FIT OF BEND 2" 90° BRASS BEND (FIPT x PACK JOINT), FORD C14-77-Q-NL OR EQUAL OG ADAPTER 2"x2 Y2" BRASS ADAPTER (FIPTxMNST) C CAP 2 Y2" CAP (FNST) WITH GASKET, NOT VENTED METER BOX, ARMORCAST A6001640PCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ OI METER BOX AND LID "RENTON WATER", EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX O BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 STD. PLAN - 340.1 •• PUBLIC WORKS 2" BLOW -OFF ASSEMBLY APPROVED: "` DEPARTMENT (PERMANENT) 6/28/2( Martin Pastwh, DATE Public Works Adminirtra°r a a a EXISTING WATER MAIN 8,+ TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING TEMPORARY BLOCKING NEW DI WATER MAIN CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (MJxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (2) GATE VALVES (FLxMJ) (1) ADAPTER (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3. COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE PUBLIC WORKS CONNECTION TO WATER MAIN DEPARTMENT CUT -IN TEE AND TWO VALVES STD. PLAN - 300.2 DATE METERED BACKFLOW ASSEMBLY (TO BE OBTAINED FROM CITY) (1) 21/2" CONTROL VALVE (1) CONSTRUCTION METER (1) RPBA METER SUPPORT (BY CONTRACTOR) NSF 61 SUPPLY HOSE HYDRANT ON EXISTING WATER MAIN TEMPORARY BLOW -OFF ASSEMBLY (1) 2" GALVANIZED PIPE (1) 2" 90° BEND (1) 2" GATE VALVE II POLYPIG POLYPIG STATION (1) VERTICAL CROSS (MJxFL), SIZE TO MATCH WATER MAIN (1) BLIND FLANGE WITH 2" TAP ON TOP OF CROSS (1) TEMPORARY BLOW -OFF ASSEMBLY (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY THRUST BLOCKING NOTES: 1. THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY HOSE MUST BE DISCONNECTED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. 2. POLYPIG AND ALL DEBRIS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS VIA SANITARY METHOD PRIOR TO DISINFECTION OF NEW WATER MAIN. 3. UPON REMOVAL OF POLYPIG, REMOVE TEMPORARY BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG. 4. THE NEW WATER MAIN SHALL BE CONNECTED TO THE EXISTING SYSTEM ONLY AFTER NEW WATER MAIN IS POLYPIGGED, DISINFECTED AND SATISFACTORY BACTERIOLOGICAL SAMPLE RESULTS ARE OBTAINED. 5. THE INTERIORS OF ALL PIPES AND FITTINGS TO BE USED IN FINAL CONNECTION MUST BE SWABBED OR SPRAYED WITH A 5-6% AVAILABLE CHLORINE SOLUTION. STD. PLAN - 300.7 PUBLIC WORKS APPROVED: DEPARTMENT POLYPIGGING NEW WATER MAINS 6/28/2023 Mahn Pastuch" DATE Pnehr work: namm:v"« WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITYTESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. ti�Y o STD. PLAN - 300.0 a� PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2O10 F NCO UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ NO. 1114' AND 22 Y2 ° BENDS FPIPE CLAMP AND ANCHOR ROD i A _A 45' BEND PIPE CLAMP AND ANCHOR ROD oL L�`� yp va o A A 90° BEND PIPE CLAMP AND ANCHOR ROD MINIMUM DIMENSIONS PIPE SIZE BEND VOLUME (CF) A D L 4" 11 Y4 BLOCKING NOT REQUIRED 22 Y2* 45° 90° 16 2.5' 3/4' 2.0' 11 Y4 BLOCKING NOT REQUIRED 22 Y2' 6" 45° 13 2.3' %11 2.0' 90° 43 3.5' %11 2.0' 11 Ya° BLOCKING NOT REQUIRED 221/z° 8" 45° 33 3.2' 3/4" 2.0' 90° 86 4.4' 3j4' 2.0' 11Y/4° BLOCKING NOT REQUIRED 10" 22 YZ 13 2.3' 3j4' 2.0' 45° 64 4.0' %11 2.0' 90° 141 5.2' 1" 3.5' 11 Ya BLOCKING NOT REQUIRED 22 Y2* 20 2.7' 3/q' 2.0' 12" 45° 111 4.8' 3/q" 2.0' 90° 206 5.9' 1 Y$' 4.0' * D =ANCHOR ROD DIAMETER MINIMUM DIMENSIONS BASED ON FOLLOWING CONDITIONS: • PIPE RESTRAINED MINIMUM 36' ON EACH SIDE OF BEND • SAFE BEARING LOAD = 1,000 SF L • CONCRETE STRENGTH = 3,000 PSI • CONCRETE WEIGHT = 150 PCF A • HYDROSTATIC PRESSURE = 200 PSI • TRENCH = TYPE 2 FLAT BOTTOM TRENCH WITH LIGHTLY CONSOLIDATED BACKFILL PER ANSI/AWWA C150/A21.50 L ° ' • FACTOR OF SAFETY = 1.5 • SOIL FRICTIONAL RESISTANCE BASED ON COHESIVE I_ -I GRANULAR SOIL (GC+SC), SAND, GRAVEL, CLAY MIXTURE f A CONCRETE BLOCKING DESIGN MUST BE ADJUSTED FOR NOTES: VARIANCES IN ANY OF THESE CONDITIONS. 1. NO CHANGE IN PIPE DIRECTION OR DIAMETER SHALL OCCUR WITHIN 36' OF THE VERTICAL BEND. BENDS, TEES, REDUCERS, ETC. BEYOND THE 36' LIMIT MAY BE RESTRAINED BY STANDARD CONCRETE BLOCKING PER STD PLANS 330.1 AND 330.2. 2. FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 3. PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4. JOINT RESTRAINT SHALL BE MEGALUG SERIES 1100 OR EQUAL. 5. WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM T COVER. 6. 90° VERTICAL BENDS SHALL ONLY BE INSTALLED WHERE GIVEN PRIOR APPROVAL BY THE CITY. 7. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 8. BACKFILL TRENCH BEYOND 90° VERTICAL BLOCK WITH CRUSHED SURFACING TOP COURSE MATERIAL COMPACTED TO 95% MDD. CRUSHED BACKFILL SHALL EXTEND 20' BEYOND BLOCK OR TO FIRM BEARING TRENCH WALL, WHICHEVER IS LESS. 9. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. SURVEYED: 8Y OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORS CHECKED: HOLL/ HEA VR/N BY DATE APPR APPROVED: HOLL/ HEA VR/N CONCRETE BLOCKING STD. PLAN - 330.3 PUBLIC WORKS APPROVED: DEPARTMENT FOR VERTICAL FITTINGS WITH RESTRAINED JOINTS 6/28/z( o ei:"w�:i,: enm„.r.,..,. DATE 4.2.1 PIPE SYSTEMS -DESIGN CRITERIA FIGURE 4.2.1.B PIPE ANCHOR DETAIL A�111,-1_ 6n MiN 2'M/ry i e.v. a _ CONCRETE BLOCK A CONCRETE BLOCK ANCHOR vie v.. o e`o_ p v p v P. v CONCRETE SECTION A -A FOOTING NTS KEYEDINTO UNDISTURBED SOIL AS SHOWN 2021 Surface Water Design Manual SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY C5 6" MIN. STRAP -FOOTING ANCHOR -(TYPICAL) NTS z 6" MIN. A NOTE: FOR SOLID WALL HDPE, PIPE MUST BE FREE TO SLIDE INSIDE A 4' LONG SECTION OF PIPE ONE SIZE DIAMETER LARGER. 6" MIN. v .. . hr�`a Yr. VMIN. kiv .'v11v 2 x PIPE DIA. r MIN. SECTION B-B NTS VERnCAL• NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 4-15 1" MIN. DIAMETER STEEL ROD (STRAP) CLAMPED SECURELY TO PIPE. CONCRETE FOOTING KEYEDINTO UNDISTURBED SOIL AS SHOWN 7/23/2021 CITY OF RENTON Planning/Building/Public Works Dept. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE 'Con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425512 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER STANDARD DETAILS O O O DATE: O FI0/111202J ELOBo PAGE: DRAWING NO: C6.32 SHEET: OF, 59 93 CONSTRUCTION RECORD DRA WINGS Z ti O Z O TOP OF SLOPE (TYP) 7\ APN g5�pg9�R C / TRACT K (CRITICAL AREA) AP ZHIIANO9 HU0 0 LAT N4730'16.6071 " LON- W12210'02.7073" EXISTING TREE TO BE SA VfD (TYP) T TRACT A (ACCESS & UTILITY); EX/STING OFFS/TE TREE - TO REMAIN (TYP) — — — — UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 it A PHUONO MY9v04 TRACTN_ (OPEN SPACE) LAT N4730'11. 090J / /1AL IA14n0)04/11/14 nn7411 Uj W Q Z 0 W FI • ► CONNECT TO EX/STING SEWER CONNECT TO EXISTING WATER LAT N4730'16.8158" LON- W12210'01.8512" SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N CONNECT TO EXISTING STORM LA T.• N4730'16.3027" LON.- W12210'00.7352" LAT N4730'16.0052" LOM- W12210101.2464" LAT N4730'15.5734" LON.• W12210'00.2517" SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY LAT N4730'15.2397" LON- W122 0959. 4885" LON- W122 09 59.9369" EXISTING WA TER VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM i \s TOP OF SLOPE (TYP) 15' BLDG SETBACK (TYP) 15' BUFFER (TYP) I / p42305-9E45LLC pALPAY PROPER PROPOSED WATER (TYP) PROPOSED STORM (TYP) PROPOSED SEWER (TYP) APN F4OPER1E51LLC pALPAY CITY o NOE LANo L.L.A• REC. ApN 04ASSOC A1E5 LLC pALPAY & PROJECT BOUNDARY (TYP) LAT N4730'11.0413" LON: W122 0957.5837" CITY OF RENTON Planning/Building/Public Works Dept. I N l SCALE: 1" = 50' 0 25 50 100 STORM LEGEND STORM PIPE STORM SERVICE EXISTING STORM P/PE STORM PIPE FLOW ARROW �❑ STORM STRUCTURE - TYPE 1 CB STORM STRUCTURE - TYPE 2 CB SEWER LEGEND SEWER P/PE SEWER SERWCE ss - EXISTING SEWER P/PE 0 SEWER STRUCTURE O SEWER CLEANOUT WA TER LEGEND WA TER MAIN EXISTING WATER PIPE -sI IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF AIR- VAC POWER LEGEND POWER CONDUIT STREET LIGHT POWER VAUL T 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425536 S-425513 W-425513 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 COMPOSITE UTILITY PLAN vo 0 0 0 N N �i N ti DATE: O 0/111202J FIELDeo PAGE DRAWING NO: �1 C7. 01 SHEET: OF: 60 93 CONSTRUCTION RECORD DRA WINGS Z ti O Z O O v UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 SEE SHEET C7.03 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY O 0 N M N v `(EYMAP 0 0 0 N N K SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE -� STORM SERVICE -SD EXISTING STORURIPF STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE - TYPE 1 CS STORM STRUCTURE - TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERWCE _SS EX/STING SEWER PIPE � SEWER PIPE FLOW ARROW 0 SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND WA TER MAIN -W EXISTING WATER PIPE H C WATER F/TT/NG • FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF AIR- VAC v 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 �-425537 S-425514 1A-425514 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Lyqi PMENT ENGINEERING WASTEWATER UTILITY 12/06/2023 jstowell 11 /30/2023 N ODATE: VERnCAL• NAVD 1988 . HORIZONTAL- NAD 1983/1991 1 CITY 0 F TOWNS ON 2TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: DATUM DRAWING NO: Planning/Building/Public Works Dept. UTILITY CROSSING PLAN C7"02 SHEET: OF: 61 93 Lr) 4 SEE SHEET C7.02 N N NLO �0°50 rr 53 54 :.;II r / d' d' APN 3307801LE � � 55 56 57 58 59 • . I� g TRACT H / 41 (CRITICAL AREA) I I JEN / � \ Nr ' I TRACT L (CRI T/CAL AREA) % a 42 I / �/ I \ \ / 1�\W ,I ;.• 'a ' 39 ❑ I 4 ,. ( 305,9245�GG y \ �I ly \ , a pN 042opERTIEs 43 "OAApAY PR ` EXISTING TREE TO BE SA VED 44 52 51 50 49 4R Q (rYP) 46 ; rrH c, i [a ` h � \ v�l Pz SEE UTILITY CROSSING TABLE .�0 9PEN " N SHEET C7.04 (TYP) Y TRACT M 45 SPACE) e � u F IIzi b 3 i 9 •' NI+IN 5 9°46 \ 1 �� 5 � ❑ �iJ \ ApN ° pON WONO �\ / \ 28 29 30 24 25 26 27 31 32 33 34 O PROPOSED WATER (TYP) 35 36 37 9061 I PROPOSED SEWER (TYP) 6 ApN 4230ERT1C5 LLC PPOP M I PROPOSED STORM (TYP) ]NI p ALp AY TRACTA `. 7 ... STMENT N• 1 \ i (ACCESS & UMITY) a ApJO —3002 TRACT B "" , ... ,. ... ' L°T LINELLA, LN O9 O .. (ACCESS & UTILITY)' A :. : ' . RENTON LO 106, 2g000 7.CITY O NO• LINO 20°50 g2 I — ' L.L.A. REC- I 23 22 21 20 19 18 17 16 15 14 13 12 Jill 10 9 ApN 0423o5�Y�O4 pHUON I'' row 0425500 TRACT /V ApN 305— 0423ATES LLG ApN 055— 2 (OPEN SPA OALpAY & A DAMES UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH NO. REVISION BY 1 DATE 1 APPR SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M c� SD SD-- o—o—o CONNECT TO EXISTING WATER CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE STORY _SD EX/S NGESTORM P/PE STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE — TYPE 1 CS STORM STRUCTURE — TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERWCE _SS EX/STING SEWER PIPE ­4 SEWER PIPE FLOW ARROW 0 SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND r�:••wAf•r WA TER MAIN —W EXISTING WATER P/PE v HI WATER FITTING �• ~� Z z • FIRE HYDRANT ® WA TER METER 9 •� TYPE / BLOW_ OFF AIR— VAC 100NAL 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425538 S-425515 W-425515 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 w 0 0 N M N v 0 0 N N WASTEWATER UTILITY jstowell 11 /13/2023 kmj 141% TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 UTILITY CROSSING PLAN DATE: 0/111202J FIELDeo PAGE DRAWING NO: �7 C7.03 SHEET: OF: 62 93 O O N O N v O O O N N