HomeMy WebLinkAboutzW-4255setZ ti O Z O W SEE SHEET C6.07 (ROW 6) EXISTING TREE -/ TO BE SA VfD (TYP) SEE SHEET C6.06 - (ROW 5) SEE SHEET C6.05 - UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 (ROW 4) /� CONNECT TO EXISTING WATER SEE SHEET C6.09 (WA-1 PROFILE) SEE SHEET C6.09 (NE SUNSET & W) o LLJ z (10 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORS CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: SEE SHEET 06.02 (ROAD A STA 15f00-END) SEE SHEET C6.01 (ROAD A START-STA 15*00) NE 12TH ST 1 - - -SD — AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M TOP OF SLOPE (TYP) 15' BLDG SETBACK (TYP) 15' BUFFER (TYP) I 5EE SHEET C6.04 (ROW3E-W&N-S) SEE SHEET 06.03 (ROW 1 & ROW 2) EX/STING GROUND CONTOUR (TYP) PROPOSED FINISH GRADE CONTOUR (Typ) PRO✓ECT BOUNDARY (TYP) SEE SHEET C6.08 (NE 112TH ST) CITY OF RENTON NIftmor Planning/Building/Public Works Dept. SCALE: 1" = 50' 0 25 50 100 WA TER LEGEND WATER MAIN WATER EASEMENT WATER BSBL EX/STING WATER P/PE WATER FITTING FIRE HYDRANT WATER METER TYPE / BLOW -OFF AIR- VAC 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425501 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING 'a yqi 12/06/2023 TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: COMPOSITE WA TER PLAN C6.00 SHEET: OF: 48 93 O O O N N Z N H O Z O Z ti O Z O TRACT H (CRITICAL AREA) EX TREE TO BE SA VED (TYP) 10' UTILITY EASEMENT (TYP) m 0� J�n �C R 56LF m m -off ai + 0 0 � lV � 14f55.58, 5.00' RT 1-12'%8" TEE (FL) 2-12" GATE VAL VES (FLxYd) 1-8" GATE VAL VE (FLxUd) W/ CONC BLOCKING ,,, N V430 W v, Ow 420 Q) VJ vi LQ V Q410 N PROPOSED FINISH GRADE CONTOUR (TYP) -- .7CL %7F 7LL / C6.06 12*94.29, 5.00' RT 1-12" CROSS (FL) 2-12" GA TE VAL VES (FLxM✓) 2-8" GAVE VAL VE (FLxM✓) w / nnA in n1 nn/i/A in non FIRE HYDRANT ASS'Y W/ CONC BLOCKING STANDARD 1 " WA TER SERVICE PER C. O.R STD DTL 320.1, SEE SHEET C6.31 (TYP) 12f32.24, 5.00' RT 12 x6" TEE (M✓xFL ) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 11f35.29, 5.00' RT W/ CONC BLOCK/NG - PROPOSED STREET LIGHT (TYP) SEE SHEET C6.O8 FIRE HYDRANT ASSEMBL Y PER C. O.R STD DTL 310.1, SEE SHEET C6.31 (TYP) EX GROUND CONTOUR (TYP) C-lN• (BYC/TYFORCES) SCALE: 1) = 30) uT999, 5.00' RT CONNECT TO EX WATER 0 15 30 60 1-8" TE(FL) E 3-8" GA TE VAL Vf-5 (FLxUJ) 1-8"x12" REDUCER (M✓) 2-8" LONG BODY TRANSITION COUPLING (8" A. C. TO 8" D.l.) 1-8" SLEEI/E (M✓) FINAL CONNECT/ON BY CITY FORCES W/ CONC BLOCKING, SEE NOTE 9, THIS SHEET 12" POL YP/GG/NG STATION PER C.O.R. STD DTL 300.7, SEE SHEET C6.32 HIGH PT ST : 12f85.84 HIGH PT I L.• 430.28 LOW PT STA: 10 65.77 PW STA: 13f00. 00 LOW PT EL: 4 7.88 I, PW EL: 430.68 o0 00 PW STA: 10*60.00 100.0 12f84.29 ROAD A 2, VC o PW EL: 427. 8 0 o Q PROPOSED GRADE y. = rn , 30f00 = ROW 3 �. o o 0 50.00 VC Q p 0ROAD � (TYP) o� •mod �W EL: 430.28 I w 3 ii ow EX/STING GROUND w 12f89.35 = ROAD A w 54f59.91 =ROW 4 o m o m PROPOSED 12 WATER (TYP) rn ii r\ �, o�, W �� ii Q2� °� o 0ROAD �' (TYP) EL: 430.28 _ �o�r ww mm Ip - _�q _2 24q o 0 I s = p 1-3 o j 00 who 0 Z �C,3 Lj �m W o o w _-Aj IQS ROAD A EX/STING ELEV. PROPOSED ELEV. HOR/Z. SCALE- 1 "=30' 0 ROAD 0 ROAD f (TYP) VERT. SCALE. ad of O ci ad ad N 15+00 14+50 14+00 13+50 13+00 12+50 12+00 11+50 11+00 10+50 10+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH NO. REVISION BY 1 DATE 1 APPR SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM `(EYMAP WA TER LEGEND WATER MAIN WATER EASEMENT WATER BSBL EX/STING WATER PIPE WATER FITTING FIRE HYDRANT WATER METER TYPE / BLOW -OFF AIR- VAC GENERAL NOTES 440 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECAON. 2. ALL CONSTRUCAON SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD SPEC/F/CA77ONS. 3. LOCATIONS OF EX/SANG U77LI77ES SHOWN ARE APPROX/MATE. EX/SANG UAL/T/ES SHALL BE FIELD LOCATED BY RESPEC77VE UALITY COMPANIES PR/OR TO CONSTRUCAON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECAONS TO EX/SANG PIPES 430 FOR PROPER FITANGS AND DEPTH. 5. CONTRACTOR SHALL NOTIFY ALL AFFECTED UTILIAES 24 HOURS PR/OR TO CONS7RUCAON. 6. ALL WATER FITANGS AND VAL VES WITH MECHANICAL JOINT (M✓) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REOU/RED ON ALL WATER FITANGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL 420 LENGTH OF WATER PIPE SHALL BE USED Wl1H THE PIPE CENTERED FOR MAX/MUM JOINT SEPARA AON. 9. IF THE TOWNHOMES PROJECT COMES FIRST, THE PROJECT COULD AE IN ON THE EX/SANG 8" AC WATER MAIN AS SHOWN ON THE PLAN. 410 CITY OF RENTON Planning/Building/Public Works Dept. 10. IF THE TOWNHOMES PROJECT /S BEHIND THE SCHEDULE. THE CITY C/P PROJECT WILL INSTALL THE TWO TEES WITH STUBS TO THE PROPERTY L/NEAT DEVELOPERS COST FOR FUTURE CONNECAONS, AND INSTALL THE FIRE HYDRANT TO THE EAST W/TH/N NE 12TH ST. 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425502 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 WATER UTILITY ABDOUL GAFOUR 11/09/2023 TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROF/LE ROAD A (START- 15+00) 0 0 0 N N i N H DATE: O 0/111202J FIELDeo PAGE DRAWING NO: �7 C6.01 SHEET: OF: 49 93 Z ti O Z O O v 17*25.57, 5.00' RT 1-12" 45° BEND (M✓) W/ CONC BLOCK/NG WATER EASEMENT (TYP) WATER BSBL (TYP) 17f82.17, 5.00' RT SEE SHEET 1-12" TEE (FL) C6 07 221F 3--12" GA TE VAL VE (FLxM✓) 12" DI 1-12"x8" REDUCER (FL) 4-4 71 1-8" GATE VAL VE (FLxUI) 84 p W/ CONC BLOCKING A -- — — — 85 — 86 3 17*62.51, 5.00' RT 87 r`j I I- °j 12"x6" TEE (M✓xFL) SEE 1-6" GATE VAL VE (FLxM✓) F/RE HYDRANT ASS'Y SHEET W/ CONC BLOCKING C6.07 FIRE HYDRANT ASSEMBL Y PER C.O.R. STD DTL J10.1, SEE SHEET C6..31 (TYP) R 430 420 410 18+50 16*96. 08, 28. 75' L T 1-12" 45° BEND (M✓) W/ CONC BLOCK/NG 0 I 74 TRACT) y (STORM DRAINAGE) � a- 73 1 ► I 72 PROPOSED FINISH GRADE CONTOUR EX GROUND (TYP) SEE SHEET C6.09 CONTOUR (TYP) w .\� PROPOSED \ \ 402�.\` STREET LIGHT (TYP) W e P­=== PROPERTY LINE , (TYP) 1Q4 t� ','O\\ q22 \ — 15f56.32, 5.00 RT \ IILF 12 DI Q 1-12'X225*BEND (MJ) — W/ CO/VC BLOCKING > OEM 69 68 66 63 III 65 I 64 TRACT M 16,142.54, 22.33' L T (OPEN SPACE) 1-12" 45-BEND (M✓) W/ CONC BLOCK/NG 16f 15.21, 5.00' RT 1-12" 45° BEND (M✓) W/ CONC BLOCKING 18+00 17+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/g1 17+00 16+50 /2„ • 15f 11.18, 5.28' RT \OO D/ — 1-12'x225° BEND (M✓)° / W/ CONC BLOCK/NG TRACT H A (CRI77CAL AREA) 0— \ 10' UTILITY \ � '• � � � �00EASEMENT E �,5 (TYP) NEON c6,01 62, 61 60 MATC EET E5N 5E -16f 05.73, 5.00' RT STANDARD 1 " WA TER SERVICE 12"x6" TEE (M✓xFL) PER C.O.R. STD DTL 320.1, 1-6" GATE VAL VE (FLxM✓) SEE SHEET C6.31 (TYP) F/RE HYDRANT ASS'Y W/ CONC BLOCK/NG 16+00 1 440 i PROPOSED ELEV. F ® ROAD � (TYP) 15+50 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HE VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HE VR/N 430 v W1v, J' vJ 420 0 V, vi 4-4 410 Q SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. //: J WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE—HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/STING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE —TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON —POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 0 0 N M N v 00 0 N N Q V 0 0 0 N N 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425503 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.02 � ROAD A (15+00 -END) SHEET: OF: 50 93 Z ti O Z O 450 „m 430 420 51f34.97, 7.00' RT 1-12 x8" TEE (FL) SEE SHEET 2-12" GA VE VAL VE (FLxM✓) PROPERTY LINE 1-8" GAVE VAL I/E (FLxM✓) (TYP) C6, O5 W/ CONC BLOCKING I�11,\ �_ - . , 1 1 �/tiv X� ~ I 11 EX OFFSITE TREE I \ \ 23 22 21-0 TO REMAIN (TYP) . �.: a: 43� � _ 19� A 0`�23p5Yg�C I z� � P UONG M 25LF 8" y• TRACT M _ - (OPEN SPACE) I I/IIVIIl\f I�I TRACT N 8 SEE SHEET (OPEN SPACE) C6.05 WA TER BSBL (TYP) WATER EASEMENT (TYP) 18+00 18+50 19+00 19+50 7 19 18 17 V I \v � � /\\ 1568-D1 � 6) 19*42.64, 3.00' RT 1-11.25° BEND (M✓) W/ CONC BLOCK/NG 19f57.73, 6.00' RT 1-11.25° BEND (MJ) W/ CONC BLOCKING 20+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 SEESHEET C6.01 II 10' UTILITY EASEMENT (TYP) u I 16 15 14 13 1 Ll fl7 J. i RESTRAINED JOINT PIPING i TRACT 0 5 (OPEN SPACE) 11 4 \ 3 RESTRAINED SEE SHEET 20*05. 00, 6. 00' RT JOINT 1-12"x8" CROSS (FL) PIPING C6, 01 2-12 GA TE VAL Vf- (FLxM✓) 2-8" GATE VAL I/ES (FLxM✓) W/ CONC BLOCKING 450 430 420 20+50 „m STANDARD I" WATER SERVICE C.O.R. STD DTL 320.1 PROPERTY LINE PER SEE SHEET C6.31 (TYP) (TYP) 11 U LJ I EX GROUND 15 CONTOUR (TYP) 12 11 10 21*76.51, 6.00' RT 1-8" PLUG )VJ) 1-2" BLOW -OFF ASS? LIT W/ CONC BLOCK/NG 1-8" POL YP/GG/NG STATION I PER COR STD. PLAN NO. 300.7 ?LF 80 D/ I 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 1 3p5,9235 _LC 1� ApN 04ASSOCIAiE m PROPOSED FIMSH m GRADE CONTOUR 11 2 1 I I (Typ) WA TER EASEMENT (TYP) WA TER BSBL (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: 1" = 30' 0 15 30 60 . . . . . . . . mo�O h^ W . o Q PROPOSED GRADE s N W 9 ROAD f (TYP) OPOSED 8" In 1 TER (TYP) W N O N "� o EX/STING GROUND 0 ROAD (TYP) Q . v r . Q . . . . . . . . . . . . . . . . . . o i O j . . . . . . . . PROPOSED ELEV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ROAD f (TYP) RO 1 . EX/STING ELEV. HOR/Z. SCALE.• 1 "=30' ® ROAD f (TYP) INERT. SCA E.• 1 "5' . 20+00 20+50 21+00 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NE 2TH ST `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 440 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/S77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES 430 FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL 420 LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 410 21+50 22+00 22+50 VERnCAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 CITY OF 0 RENTON DATUM Planning/Building/Public Works Dept. L 0 O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.03 � ROW 1 & ROW 2 SHEET: 51 OF: 93 Z ti O Z O ii/ v 0 430 \- 420 410 TOP OF SLOPE 40f83.34, 5.00' RT (TYP) 1-8" PLUG (M✓) 40 �� TRACT H 1-2" BLOW -OFF ASS? `' • •, •' h �� (CRITICAL AREA) W/ CONC BLOCKING 1-8" POL YP/GG/NG STATION 4 PER COR STD PLAN 300.7 Bs� N PROPOSED FINISH / a GRADE CONTOUR ' 31f0150, 6.00 L T 42 I J — �I \ (TYP) 1-.6 TEE (FL) .30f05.00, 10.00 L T ` = 2 BLOW OFF 1-12" CROSS (FL) 3--8" GATE VAL I/ES (FLxM✓) ) I . PER C.O.R. STD DTL 340.1, 3-12" GATE I/AL l/ES (FLxM✓) W/ CONC BLOCK/NG — 39 I SEE SHEET C6.32 (TYP) 1-12"x8" REDUCER (FL) — - EX TREE 1-8" GA VE VAL VE (FLxM✓) SEE SHEET C6.O1 I / ` I �\ TO BE SA VED W/ CONC BLOCKING 43 I � I (TYP) 108LF 12 Dl < � I I � J\ - I I h `TRACT G \ 1.. (OPEN SPACE) 1 4 ... 4 �i 173LF 12 DI � I 38 I WA TER BSBL (TYP) RESTRA/NED I 's < ru JOINT PIPING 1 p 45 I I I I 46 t i7LF 8„ DI o � ' WATER EASEMENT (TfP) W 8" DI W "� NI IN� t . 15LF 8" DI 42g — 8" DI i PROPERTY L/NE � (TYP) (� ROW I 7,2LF 8 DI / I Wv N `r N _ 1f75.50, 6.00' L T I I I m 1-8N PLUG (MJ) M I \ 1-2 BLOW -OFF ASS? 30 i I 31 32 , 33 34 , I° I 35 36 37 I \ 'W/ CONC BLOCK/NG 1\ �1-8" POLY P/GG/NG STATION ' RESTRA/NED p/P/NG OIN TI II II 115 PER COR STD PLAN 300.7 I-222. 01, O (L T 30f36.80 6. 00' L T STANDARD I- WATER SERVICE EX GROUND 1-22.5°BEND (M✓) SEE SHEET PER C.O.R. STD OTL 320.1, CONTOUR (TYP) W/ CONC BLOCKING 1-225°BEND (MJ) C6.01 W/ CONC BLOCKING SEE SHEET C6.31 (TYP) 10' UTILITY EASEMENT (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMA TION. N PROPOSED GRADE li 0 ROAD � (TYP) u h p N 8"_, 1,P) EX/STING GROUND 0 ROAD f (TYP) - .00 PROPOSED ELEV. 0 ROAD � (TYP) ROW 3 (E ST-WEST EX/STING ELEV HOR/Z. SCALE. 1 "=30' 0 ROAD � (TYP) INERT. 30+00 30+50 31+00 31+50 - ASPHALT THICKENED EDGE TO BE ADDED TO END OF ROW 3, TO DIRECT DRAINAGE TO CB 21 J1*7560 = ROW 3 -EL: 424.58 END ROD IMPROVEMENT 32+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 440 440 1 430 A 410 32+50 1 i 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS \I�Cem FILMN Me, N rt";-5- A N SCALE: 1" = 30' 0 15 30 60 h 3� PROPOSED GRADE 0 0 ROAD f (TYP) II 3� o n PROPOSED 8" EX/STING GROUND oo o GRADE BREAK p N WA TER (TYP) 0 ROAD f (TYP) Z �i 41f29.55 EL. 429.13 0 I � �mQ 1 PROPOSED ELEV. 0 ROAD f (TYP) RO 3 (NORTH -SOUTH) EX/SRNG ELEV. HOR/Z. SCALE- 1 "30' 0 ROAD f (TYP) INERT. SCALE. 1 "5' 40+00 40+50 41+00 M J S 7/26/23 HHH SURVEYED: SY OTHERS K E L 9/ 12/23 HHH DESIGNED: ROLL/ HEAVR/N KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 41 f50 VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM m 430 410 42+00 CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77L/17ES 24 HOURS PRIOR TO CONS7RUC110N. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 0 0 N M N v "N O 0 N N Q V 0 0 0 N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425505 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` �' IL yqi 12/06/2023 WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING NO: O C6.04 ROW 3 (E- W & N-S) SHEET: OF: 52 93 i Z ti O Z O O v 450 I o 430 420 SEE SHEET C6.04 I I 54f64.9>, 4.94' L T 44 45 �k 31I I 1-12" CROSS (FL) 3-12" GATE VAL VES (FLxM✓) 1-12'x8" REDUCER (FL) ' • ,. �� 1-8" GAVE VAL VE (FLxM✓) W/ CONC BLOCK/NG W _ , H 12 D/ W I x W V RO 13f0 - - W W v STANDARD 1 WATER SERVICE 46LF RESTRAINED _ PER C.O.R. STD DTL 320.1, JOINT PIPING TO THE - - _ - SEE SHEET C6. J1 (TYP) END OF THE STORM LINE DUE TO NON -CONFORMING 46 I d l 30 RESTRAINED JOINT PIPING HORIZONTAL SEPARATION / I WHERE STORM /S CLOSER THAN 10.' HORIZONTAL TO WATER 47 *-r \ l 29 MAIN ONL Y NEEDS TO GO 10' PAST THE STORM ON EACH END. - FIRE HYDRANT ASSEMBL Y I / 28 PER C. O.R. STD DTL 310.1, 48 - SEE SHEET C6.31 (TYP) 52f06.85, 7.00' RT 12'x6" TEE (M✓xFL) o �i 1-6" GATE VALVE (FLxM✓) a v � FIRE HYDRANT ASS Y 49 - W/ CONC BLOCK/NG � I°d 26 SEE SHEET WATER EASEMENT I _ TRACTA (TYP) 50 "1 A� (ACCESS &UTILITY) C6.03 - 25 = 22 1 I. 27 24 52f93.96, 7.49' L T 1 7 - ` 1-12"x45° BEND (M✓) I \ - - _ _ - A Q I - W/ CONC BLOCKING 52 _�L 2JLF 12" D/ / F 52f73.83, 0.20' L T _\- f 66LF 12" DI 44 72LF 12"D/ I IN 144LF 12"DI 1-12 x45° BEND (M✓) °' W 4 52fOQ�_: � � _ _ _BSBL W/ CONC BLOCK/NG �` �� - ' i - �0 15, t TRACT M TRA CT L (OPEN SPACE) EX TREE PROPERTY LINE (CR/T/CAL AREA) �_ TO BE SA VED ;L (TYP) (TYP) PROPOSED FIN/S ^- o GRADE CONTOU EX/ST7NG GROUND ® ROAD � (TYP) j � T PROPOSED GRADE ® ROAD � (TYP) -2 46.E PROPOSED 12" - WA TER (TYP) Z m ROW 4 EX/S71NG ELEV. PROPOSED ELEV. HOR/Z. SCALE. I- 30' ® ROAD � (TYP) ® ROAD f (TYP) - VERT. SCALE- 1 "=5' IN a 55+00 54+50 54+00 53+50 53+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 (T HIGH T STA: 51f46.93 HIGHPT EL: 437.21 P STA: 51f37.96 80.004VC81 �1, II II N v 52+50 52+00 51 +50 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS 7r.�l :a •► W h SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 10' UTILITY EASEMEN7 51f34.97, 7.00' RT / (TYP) 1-12'x8" TEE (FL) PROPOSED STREET 2-12" GA VE VAL VE (FLxM✓) LIGHT (TYP) 1-8" GAVE VAL VE (FLxM✓) W/ CONC BLOCKING SEE SHEET WATER EASEMENT C6, 08 (TYP) WA TER BSBL (TYP) I I �yrk TRACT N 3 -(OPEN SPACE) - + a ao /436� 15 : is 00 I y.. O ►I INI �� - O o 00 DCVA J. �s SCALE: 1" = 30' 0 15 30 60 EX GROUND CONTOUR (TYP) 49f91.41, 7.00' RT CONNECT TO EX WA TER 1-8x8,, TEE (FL) J--8" GATE VAL VES (FLxM✓) 1-12'x8" REDUCER (M✓) 2-8" LONG BODY TRANS/TON COUPLING (8" AC TO 8" DI) N FINAL CONNECTION BY CITY FORCES W/ CONC BLOCK/NG � Z O U Z U u H RESTRAINED LQ R JOINT PIPING '�) SEE SHEET C6.08 LOW PT ST : 50*41.99 1 " LANDSCAPE LOW PT : 434.72 IRRIGATION METER AND PW STA: 50*50.00 DCVA PER COR STD PLAN O PW EL: 434.39 O 34 .8, SEE LANDSCAPE 50. 01 VC ho P N L4.03 512, WW mm 64Q Oo� -2.00% 51 +00 50+50 50+00 M J S 7/26/23 HHH SURVEYED: DINERS SCALE. HOR ONTAL• NADVD 1988 991 KEL 9/12/23 HHH DESIGNED: AS NOTED KEL 10/11/22 HHH ROLL/ HEAVR/N DRAWN: MARY MOORE ONE INCH DATUM CHECKED: AT FULL SCALE ROLL/ HEA VR/N IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY ROLL/ HEA VR/N 12" POL YP/GGING STA77ON PER C.O.R. STD DTL 300.7, SEE SHEET C6.32 ii/ W X X CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP WA TER LEGEND WA TER MAIN - - WA TER EASEMENT - - - - - - - - WATER BSBL EX/SRNG WATER PIPE IV] IN[ WATER RT77NG Ak FIRE HYDRANT ® WA TER METER •� TYPE I BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFAC7URER'5 RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONS7RUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXIS77NG U77LI77ES SHOWN/ ARE APPROXIMATE EX/STIIVG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAVE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRE7F THRUST BLOCKS REOU/RED ON ALL WATER RT77NGS PER C.O.R. 57D PLANS 330.2 AND 330.3. 8. WHERE NEW WA7FR MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARA 17ON. O O N M N v O O N N 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425506 IN COMPLIANCE WITH CITY OF RENTON STANDARDS i DEVELOPMENT ENGINEERING s os yqi 12/06/2023 � � L WATER UTILITY ABDOUL GAFOUR 11/09/2023 I ODATE: TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.05 � ROW 4 SHEET: OF: 53 93 Z ti O Z O O v TRACT M (OPEN SPACE) 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) EX GROUND CONTOUR (TYP) �. 8" POL YP/GG/NG STATION PER COR STD. PLAN NO.. 300.7 EX TREE TO BE SA VED (TYP) Z2 15' BSBL (Typ) Em 430 420 410 66 65 1 64 —1— 63 51f77.31, 6.00' RT 1-8" PLUG (M✓) I 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING / 12, 50f 49.44, 5.60' RT 1-8"x11.25' BEND (M✓) W/ CONC BLOCK/NG 62 161 60 WA TER EASEMENT (TYP) - WA TER B59L (TYP) RESTRAINED ✓DINT PIPING I �Eo 53 54 55 56 = REO� TRACT L (CRITICAL AREA) STANDARD 1 " WA TER SERVICE - PER C.O.R. STD DTL 320.1, SEE SHEET C6.31 (TYP) 52+50 52+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 SEE SHEET C6.02 Q 0 e r f\ 57 58 z 59 J9. 10' UT ZITY EASEMENT (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. 51 +50 51 +00 50+50 TRACT) (STORM DRAINAGE) 49f 95.00, 6.00' RT 1-12x8" TEE (FL) 1-8" GATE VAL Vf (FLxM✓) 2-12" GATE VALVES (FLxUd) W/ CONC BLOCKING SEESHEET C6.01 50+00 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N / PROPOSED F/NISH GRADE CONTOUR (TYP) 1 Eml 430 420 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON Planning/Building/Public Works Dept. tiF SG� SFT e�L 0 NE 2TH ST `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECAON AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE U77LITY COMPANIES PRIOR TO CONS7RUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M✓� END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRE7F THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. S7D PLAN 340.1. 8. WHERE NEW WA7FR MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARA 17ON. 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W 425507 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Q1 yqi 12/06/2023 EABO:TTER UTILITY GAFOUR 11/09/2023 TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 WA TER PLAN & PROF/LE Row 5 O O O N N N H DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C6.06 SHEET: OF: 54 93 Z ti O Z O O v PROPOSED FIRE HYDRANT EX GROUND PER C.O.R. STD DTL 310.1, CONTOUR (TYP) SEE SHEET C6.31 PROPERTY LINE EX OFFSITE TREE STANDARD 1" WATER SERVICE TO REMAIN (TYP) PER C.O.R. STD DTL 320.1, (TYP) SEE SHEET C6.31 (TYP) SEE WA-1 PROFILE, 76 1 75J 74 r 73 E6. SHET C09 <` / WATER SETBACK (TYP) 70f 19.82, 6.00' L T WATER EASEMENT (TYP) 1-12"x45' BEND (FLxUJ)(RJ) W/ CONC BLOCKING ' / r 14/1F. 12"D/ RJ1 171-1-00 1-- TRACT K� (CRITICAL AREA), J/ TOP OF SLOPE 15' SETBACK (TYP) 7LF 12" L BEGIN N 0 70f00 = ROW 6 EL: 422.00 ROAD IMPROVEMENT J 70+00 SEE SHEET PROPOSED FINISH C6.02 GRADE CONTOUR (TYP) 72 71 j I Q l� Q TRACT M (OPEN SPACE) TRAC 70 69 68 67 (0R A) 2" BLOW OFF / PER C. O.R. STD DTL 340.1, \ I SEE SHEET C6.32 (TYP) 72f87.77, 8.19' L T 1-8" PLUG (M✓) d•.:;,r ill -- —it 1-2" BLOW -OFF ASS'Y W/ CONC BLOCKING 1-8" POL )PIGGING 5TAT/ON PER C.O.R. STD DTL 300.7, til _ SEE SHEET C6.32 70f26.51, 6.00 L T " EX TREE 1-12TEE (FL) 12'W' TEE (FL) TO BE SA VED 1-12" GATE VAL l/E (FLxM✓) 2-12" GATE VAL vE (FLxM✓) (TYP) >->2" ADAPTOR (M✓) 1-12"x8" REDUCER (FL) 1-6" GATE VAL I/E (FLxM✓) 1-8" GATE VAL l/E (FLxM✓) FIRE HYDRANT ASS'Y W/ CONC BLOCK/NG W/ CONC BLOCKING SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. N" EXIS77NG GROUND 0 ROAD (TYP) 38% PROPOSED 12" oWATER � o 70+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ EXISTING ELEV. 0 ROAD � (TYP) - PROPOSED ELEV. 0 ROAD (TYP) 71 +00 GH PT STA: 71f80.15 HIGH PT EL.- 427.11 PW STA.- 71f72.00 PV/ EL: 427.82 ROW 6 HOR/Z. SCALE- 1" 30' VERT. SCA E. 1" 5, 10�2 I N 71+50 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS NONE i 72+00 15' BSBL 440 FILL AND COMPACT ROADWA Y PRISM TO F/N/SHED SUBGRADE PR/OR TO INS TALLAT/ON OF WATER MAINS (TYP/CAL ALL FILL AREAS) � I I PROPOSED GRADE 0 ROAD �' (TYP) �44q PROPOSED 8" WA TERM \ 72+50 0 M J S 7/26/23 HHH SURVEYED: SY OTHERS K E L 9/ 12/23 HHH DESIGNED: ROLL/ HEAVR/N KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N 430 420 410 N 73+00 73+50 SCALE: VERTICAL• NAw lsae AS NOlEO HORIZONTAL- NAD 1983/1991 ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY SCALE: 1" = 30' 0 15 30 60 CITY OF RENTON + N Planning/Building/Public Works Dept. FffA WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - - - - - - - - WA TER BSBL EX/STING WATER PIPE I IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLANS 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE 'Con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.07 ROOF, A� 6 SHEET: OF: �/ �/ 55 93 TRACT M (OPEN SPACE) PROPERTY L/NE — (TYP) 10' U7IL/TY — EASEMENT (TYP) w 79f00 � 8" WATERX(G 1) CM 11 SScC 1 A CD RIM=436.07/ IE 8" CNCM-435.22 - z RIM-437.03' can IE 12" CNC E=433.6800 IE 8" CNC SE=433.88' IE 8" CNC SW=433.88' IE 12" CNC W=433.78' 12" POL YP/GG/NG STA77ON PER COR STD DTL 300.7, SEE SHEET C6.32 SEESHEET C6.05 M W IJ W IJ TRACT N (OPEN SPACE) iBL 9 8 12" POLYP/GG/NG STATION PER COR STD DTL 300.7, SEE SHEET C6.32 7 6 1 5 PROPOSED SINEFT • TRACT , n - --- OH H SAWCUT (TYP) 817(00 o - ' 8" WATER MA IN ASBESTOS CEMENT o ?52f i NE 12TH ST,� ev V / SD SD_�D SD SD \ CM-- - CM �G Gv/ X CUT-& (BY CITY FORCES) CUT -IN: (BY CITY FORCES) 1 80f07.14, 8.47' RT 81f94.14, 1.86' RT CONNECT TO EX WA TER CONNECT TO EX WA TER I 1-8x8" TEE (FL) 1-8x8" TEE (FL) 3-8" GATE SAL VES (FLxM✓) 3-8" GATE SALVES (FLxUJ) RIM=4263' 1-8"x12" REDUCER (M✓) 1-8"x12" REDUCER (MJ) IE 8" CNC NF=475..78' 2-8" LONG BODY TRANSITION 2-8" LONG BODY TRANS177ON EX/STING WATER METEk COUPLINGS (8" AC TO 8" DI) COUPLING (8" AC TO 8" DI) TO BE ABA NOONEG 1-8" SLEEI/E (M✓) 1-8" af-f- E (MJ) W/ CONC BLOCKING W/ CONC BLOCK/NG FINAL CONNECTION FINAL CONNECTION BY CITY FORCES BY CITY FORCES m / a 2$ I I IE 12 CN774= IE 12" CNC W=424.44' PROPOSED F/N/SH GRADE CONTOUR I (TYP) PROPERTY L/NE BSBL J (T YP) PROPOSED FIRE HYDRANT PER C. O.R. STD DTL 310.1, N N SEE SHEET 0631. THIS NEW FIREHYDRANT W/LL BE i INSTALLED WITH THE CITY C/P PROJECT, AND THE TOWNS ON 12TH Df ELOPER oP— WILL REIMBURSE THE COST H _ P OF THE /NSTALLA77ON BY CITY. - SD G SD SD X -- x - - ° RIM=426.41' / CUT -IN.• (BY C/TY FORCES) IE 8" CNC Nw=*2�6' 837L68.75, 1.64' LT CONNECT TO EX WATER RIM-427.83' �1'S 8W" TEE )V✓XFL) IE 12" CNC E=424.93' 1-6" GATE VALVE (FLxUJ) IE 8" CNC SE-425.03' FIRE HYDRANT ASS'Y IE 8" CNC SW=425.03' IE 12" CNC W-425.03' 2-8" LONG BODY TRANSITION COUPLING (8" AC TO 8" DI) 1-8" SLEEI/E (M✓) W/ CONC BLOCK/NG SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. �42E W W- EX GROUND CONTOUR (TYP) -- ----SD V SD M i i O o C N 79+50 80+00 80+50 81+00 81+50 82+00 82+50 83+00 83+50 84+00 84+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N I N SCALE: 1" = 30' 0 15 30 60 SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY WA TER LEGEND WA TER MAIN — — WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLEC7ION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLECTION. 2. ALL CONSTRUCTON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXISTING U77LI77ES SHALL BE FIELD LOCATED BY RESPEC77VE UTILITY COMPANIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL NOAFY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONSTRUCTON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REOU/RED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 1 0/11/23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425509 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 WATER UTILITY } ABDOUL GAFOUR 11/09/2023 DATE: TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.OS � NE 12ST ST SH : 56 OF. 93 O O N M N v 00 O O N N Q V O O O N N Lr 10 CUT-1N.• (BY CITY FORCES) 0ti 93+70.55, 19.55' L T q� �`� CONNECT TO EX WA TER 1-12" TEE (FL) i 3-12" GATE VAL I/ES (FLxM✓) `k 0 CONC BLOCKING -P P "� P EX. 12" GATE VALVE ' - w 12" POL YP/GGING STATION PER COR STD PLAN N0. 300.7 93f00 CV /1CCC11TC rD= N TOP OF - SLOPE I I - (TYP) 15' BUFFER (Typ) PROPERTY LINE (TYP) EX TREE TO (� BE SA VED (TYP) v 370 IF CONNECTION TO THE WATER MAIN IN SUNSET IS MADE PR/OR TO THE EXTENSION OF THE ONS/TE WA TER, DEVELOPER SHALL EXTEND THE STUB FROM THE EX MAIN SOUTH TO A POINT WHERE /T /S OUTS/DE THE ROW. QF -6 �� %�����c EX GROUND ��%' R �G�P���� �`� �v CONTOUR (TYP) �`�\ c�c ��� . P T,P P r P P r' P P P P P P 12"WATER (G1) EX 12" WATER MAIN w w w w w w w w w w w w w w �r w w w = 32LF 12" DI \19r - - SEE WA-1 PROFILE, THIS SHEET 3y6\ v'9R\ �9?\ 94*00 N.• 187128.9348 .00 96,*, OO��ss � � ss 97400 ss ss � -Ss 98f00 ss � 9�00 L = 3� 1-12'x45° VERI7CAL BEND (Rd) ' i W/ CONC BLOCK/NG NE SUNSET BL VD i i / PROPOSED STREET N' 187121. J525 , LIGHT (TYP) o E.• 1310658.1103 , ' ' i 2" MPEI 1-12 x45° VERTICAL BEND (R✓) W/ CONC BLOCKING " P N. 187115.7893 _ _ -E°• 1310654.1044 41 �1-12"x45° INERT/CAL BEND (R✓) - - -l�W/ CONC BLOCK/NG 416, I \1 �� N.- 187112.7932 QO - \ E' 1310651. 9470 -1-12W5° INERT/CAL BEND (R✓) � -� ` 420 422 - W/ CONC BLOCKING \ 76 - - . CASING P/PE PER C. O.R. STD OTL 4>2, 41LF 12" D/ SEE SHEET C5.31 TRACT) N' 18706J5307 N.• 187096.5146 (STORM DRAINAGE) E' 1310616.4749 E' 1310640.2254 1-12"x45° VERTICAL BEND (R✓) 1-12"x45° INERT/CAL BEND (R✓) W/ CONC BLOCKING W/ CONC BLOCKING 5LF 12" Dl 92+50 93+00 93+50 94+00 94+50 i 95+00 95+50 96+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ �'`•--tee ` `. i�'M 'T �-� �� .. - ------------- � 420 PROPOSED FINISH GRADE CONTOUR (Typ) 390 370 0 96+50 430 420 410 390 71- -_�: - SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. EX/STING GROUND ® PIPE � (TYP) \ PROPOSED GRADE ® PIPE f (TYP) 12 x45' VERTICAL BEND (R✓) W/ CONC BLOCKING m PROPOSED 12" D/ WATER W/ RESTRAINED JOINTS (TYP) SLOPE ANCHORS ARE REQUIRED ON WATER MAIN /F GRADE /S A90Vf 209 SEE ANCHOR DETAIL, SHEET C6.32. V \ PR POSED BLOCK WALL 10' CASING PIPE EX SD PER COR STD DTL 412, lE 392.60 SEE SHEET C5.31 12"x45° VERTICAL BEND (R✓) y W/ CONC BLOCKING EX/STING ELEV. ® P/PE � (TYP) WA 1 PROPOSED ELEV. HOR/Z. SCALE- 1'=30' ® PIPE �' (TYP) VERT. SCALE- 1 "=5' �1 0+50 1 REVISED PER CITY COMMENTS MJS 7/26/23 HHH SURVEYED: BY OTHERS SCALE: AS NOTED 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE ONE INCH CHECKED: ROLL/ HEA VR/N AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE AP P R APPRovED: L/ HE l/R/N ROL 1 +00 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M TRACT H (CRI77CAL AREA) SCALE: 1" = 30' 0 15 30 60 f30 420 410 390 1+50 CITY OF RENTON Planning/Building/Public Works Dept. Kt: YImp WA TER LEGEND WA TER MAIN - - WA TER EASEMENT -------- WA TERBSBL EX/STING WATER PIPE IV] IN[ WATER FITTING A FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EXIS77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON. 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (M/) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340. t 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 0 O 0 N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425510 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.09 NE SUNSET BL VD & WA 1 SHEET: 57 OF. 93 EXISTING WATER MAIN TESTING CONNECTION - POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING NEW DI WATER MAIN TEMPORARY BLOCKING - CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (FLxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (3) GATE VALVES (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER 3. COUPLING ADAPTORS FOR CONNECTION FROM DI TO CI PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE PUBLIC WORKS CONNECTION TO WATER MAIN DEPARTMENT CUT -IN TEE AND THREE VALVES VALVE BOX AND LID SECTION A -A c 8" TO 12" r, f 12" yj MATERIALS MAIN STD. PLAN - 300.3 Marcie vssencha DATE Public Works AEminis"atm VALVE OPERATING NUT EXTENSION 2" SQUARE OPERATING NUT 4 i/4" DIAMETER 1/8" MIN THICKNESS IETER STEEL, I AS REQUIRED vyR lvnry 1 n1�nlvt» 2i/4" INSIDE MEASUREMENT 21'4" DEPTH NOTES: 1. EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE THAN 3' BELOW FINISHED GRADE. EXTENSIONS ARE TO BE A MINIMUM OF V LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. 2. ALL EXTENSIONS ARE TO BE MADE OF STEEL, SIZED AS NOTED, WITH ANTICORROSION COATING CONFORMING TO AWWA C210 VALVE MARKER POST TWO-PIECE VALVE BOX WITH REGULAR BASE SECTION TO FIT AND STANDARD 8" 34" OA VALVE BOX TOP SECTION, OLYMPIC FOUNDRY INC 940 OR RICH #045 (NON -LOCKING) 3" MIN E COVER TO MATCH VALVE BOX VALVE BOX LID MANUFACTURER, TO READ "WATER", i 62' WITH EARS IN DIRECTION OF WATER xA MAIN 8" THICK HMA FOR VALVE IN PAVED 24 �\ OC HMA COLLAR AREA OR 3'x3'x6" CONCRETE PAD IN UNPAVED AREA OOPERATING SEE DETAIL, THIS SHEET NUT EXTENSION WHITE MARKER POST WITH ANCHOR E O MARKER POST BARB AND BLUE LABEL TO READ NOTES: "WATER", CARSONITE UTILITY MARKER CRM3-066-08 OR EQUAL 1. VALVE MARKER POST TO BE USED FOR ALL MAIN LINE VALVES OUTSIDE PAVED AREAS. 2. DISTANCE TO VALVE SHALL BE NEATLY STENCILED ON THE POST WITH 2" NUMERALS. VALVE BOX, STD. PLAN - 330.7 PUBLIC WORKS APPROVED: DEPARTMENT OPERATING NUT EXTENSION, AND MARKER POST 6/28/2023 Marcie v, u DATE vublm wo.rks m Aemme"mm IVU 1 tz": 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. MATERIALS COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 51/4" MVO, OA HYDRANT 1 Y4" PENTAGON OPERATING NUT, TWO (2) 2 Y2" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. OB TEE MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET OC VALVE 6" GATE VALVE (FLxMJ) OD VALVE BOX VALVE BOX AND LID PER STD PLAN 330.7 OE PIPE CLASS 52 DI, LENGTH TO FIT OF JOINT RESTRAINT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING OR (2) 3/4" CORTEN STEEL TIE RODS OG GRAVEL 1 Y4" WASHED DRAIN ROCK, MINIMUM V ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL OH CONCRETE BLOCK MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE OI BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 JO SHEAR BLOCK 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 O PAVEMENT MARKER BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 � .}; PUBLIC WORKS '+" DEPARTMENT 0 FIRE HYDRANT ASSEMBLY APPROVED: 6/28/2023 _ Pub-d DATE llc Works AEminiscracor 90° BEND CAP / PLUG TEE n 45° BEND C 221/2° BEND 111/4° BEND MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) PIPE SIZE PR(PSI) O O O D O 4 200 2/(1) 1/(NONE) 1/(NONE) NONE NONE 300 3/(2) 2/(2) 2/(1) 1/M NONE 6 200 4/(3) 3/(2) 3/(1) 1/(1) 1/(NONE) 300 6/(4) 4/(3) 3/(2) 2/(1) 1/(NONE) 81, 200 7/(5) 5/(3) 4/(3) 2/(2) 1/(1) 300 11/(8) 8/(5) 6/(4) 3/(2) 2/(1) 10" 200 11/(8) 8/(6) 6/(4) 3/(2) 2/(1) 275 16/(11) 11/(7) 9/(6) 5/(3) 3/(2) 12" 200 16/(11) 11/(8) 9/(6) 5/(3) 3/(2) 250 24/(16) 17/(11) 13/(9) 7/(5) 4/(3) 14" 200 22/(13) 16/(11) 12/(8) 6/(4) 3/(2) 250 33/(22) 23/(16) 18/(12) 9/(6) 5/(3) 16" 200 29/(19) 21/(14) 16/(11) 8/(6) 5/(3) 225 32/(21) 23/(16) 17/(12) 9/(6) 5/(3) 18" 200 36/(24) 26/(17) 20/(13) 10/(7) 5/(4) 20" 200 45/(29) 32/(21) 24/(16) 13/(8) 7/(4) 24" 200 64/(43) 46/(30) 35/(23) 18/(12) 9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE SAFE BEARING LOAD (PSF MUCK OR PEAT 0 SOFT CLAY 1,000 SAND 2,000 SAND AND GRAVEL 3,000 CEMENTED WITH CLAY 4,000 HARD SHALE 10,000 I OTES: MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 1. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.1 • PUBLIC WORKS CONCRETE BLOCKING APPROVED: DEPARTMENT FOR HORIZONTAL FITTINGS 6/28/2023 Martin Pastucha DATE Public Works Atlminirtrator or UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 111/4° AND 221/2 ° BENDS FPIPE CLAMP AND ANCHOR ROD L L A e A� 45° BEND FPIPE CLAMP AND ANCHOR ROD A FINISHED GRADE 9" TO 12" e ° \ 24" TO 30" A /y -�22 Y2 MAIN LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER MATERIALS w w J r IN UNIMPROVED ROW, J F- CC INSTALL METER BOX w CITY PRIVATE p AT PROPERTY LINE WITH p a 1 1" COPPER TAILPIECE a PIPING PIPING - SIDEWALK � I� 12" 21" TO 30" 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, OA CORPORATION STOP FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ OB TUBING 1" TYPE "K" SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK OC METER SETTER VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS OD WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY OE METER BOX METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RCI-H7, TO READ "RENTON WATER" OF COUPLER AND PLUG COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE �G GRAVEL 1 i/4" WASHED GRAVEL PIPE SIZE BEND MINIMUM DIMENSIONS VOLUME (CF) A D L 11 V4° 8 2.0' 3/4" 1.5' 4" 22 Yz° 11 2.2' % l 2.0' 45° 30 3.1' 6" 11 Y4 11 2.2' 3/a' 2.0' 22 Yz° 25 2.9' 45° 68 4.1' 8" 11 Y4" 16 2.5' 3/4" 2.0' 22 Yz° 47 3.6' 45° 123 5.0' 12" 11 Y4* 32 3.2' 3/a' 2.0' 22 Yi 88 4.5' 3.0' 45° 232 6.1' 25 111/4 70 4. 1' 1" 3.0' 16" 22 Yz° 184 5.7' 11/$ir 4.0' 45° 478 7.8' 20" 111/4" 91 4.5' 11/4'. 3.0' 22 YZ 225 6.1' 4.0' 45° 560 8.2' 11 Y4 128 5.0' 1 Y4" 3.5' 24" 22 YZ 320 6.8' 13/$rr 4.5' 45° 820 9.4' * D = ANCHOR ROD DIAMETER NOTES: 1. CONCRETE BLOCKING SIZES BASED ON 200 PSI HYDROSTATIC PRESSURE AND 3,000 PSI CONCRETE. 2. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 3. PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4. FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 5. WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM 3' COVER. 6. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. }, PUBLIC WORKS DEPARTMENT 1 REVISED PER CITY COMMENTS MJS 7/26/23 HHH SURVEYED: BY OINERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: HOLL/ HEAI/RlN 3 REVISED PER CITY COMMENTS KEL 0/11/2 HHH DRAWN: MARY U00RE CHECKED: HOLLI HEA I/RIN NO. REVISION BY DATE I APPR I APPROVED: HOLLI HEA l/RIN CONCRETE BLOCKING FOR VERTICAL FITTINGS SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL' NAVD 198E HORIZONTAL* NAD 1983/1991 DATUM STD. PLAN - 330.2 M... Partuch. DATE Publlc Works ACminiscracw CITY OF RENTON vassiv Planning/Building/Public Works Dept. PUBLIC WORKS DEPARTMENT 1" WATER SERVICE STD. PLAN - 320.1 �-' 6/28/2023 siscracm DATE O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425511 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' Pz WATER UTILITY ABDOUL GAFOUR 11/09/2023 O TOWNS ON 12TH DATE 1011112023 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: DRAWING NO: WA TER STANDARD DETAILS C6.31 SHEET: OF: 58 93 Z ti O Z O M v PLAN PROFILE MATERIALS OA TEE MAIN LINE TEE WITH 4" SIDE OUTLET (MJxFL) WITH PLUG (MJ) 4" GATE VALVE WITH 2" SQUARE OPERATING NUT AND VALVE OPERATING NUT EXTENSION AS REQUIRED OB GATE VALVE PER STD PLAN 330.1 OC VALVE BOX AND LID VALVE BOX AND LID PER STD PLAN 330.8 OD FLANGE 4N2" TAPPED FLANGE (FLxFIPT) OE PIPE 2" BRASS OR BRONZE NIPPLE, LENGTH TO FIT F BEND 2" 90- BRASS BEND (FIPT x PACK JOINT), FORD C14-77-Q-NL OR EQUAL OG ADAPTER 2N2112" BRASS ADAPTER (FIPTxMNST) OH CAP 21/z" CAP (FNST) WITH GASKET, NOT VENTED METER BOX, ARMORCAST A600164OPCX18, WITH METER BOX LID, ARMORCAST A6001947RCI-H7, TO READ (DMETER BOX AND LID "RENTON WATER", EXPANSION JOINTS MUST BE INSTALLED 12" MINIMUM ON BOTH SIDES OF METER BOX JO BLOCKING CONCRETE BLOCKING PER STD PLAN 330.1 STD. PLAN - 340.1 PUBLIC WORKS 2" BLOW -OFF ASSEMBLY APPROVED: DEPARTMENT (PERMANENT) 6/28/2020 i Martin Pastucha PubliDATE c Works Atlminirtrator EXISTING WATER MAIN TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING 81± L TEMPORARY BLOCKING NEW DI WATER MAIN CONNECTION TO EXISTING MAIN (BY CITY FORCES) (1) TEE (MJxFL) (2) DI SPOOLS (2) LONG BODY DI SLEEVES (MJ) OR COUPLING ADAPTERS (ROMAC 501 OR EQUAL) (2) GATE VALVES (FLxMJ) (1) ADAPTER (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) NEW DI WATER MAIN NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO Cl PIPE WITH SAME OUTSIDE DIAMETER 3. COUPLING ADAPTORS FOR CONNECTION FROM DI TO Cl PIPE WITH DIFFERENT O.D. AND FROM DI TO AC OR TO STEEL PIPE STD. PLAN - 300.2 PUBLIC WORKS CONNECTION TO WATER MAIN APPROVED: DEPARTMENT CUT -IN TEE AND TWO VALVES I DATE METERED BACKFLOW ASSEMBLY (TO BE OBTAINED FROM CITY) (1) 212" CONTROL VALVE (1) CONSTRUCTION METER (1) RPBA METER SUPPORT (BY CONTRACTOR) NSF 61 SUPPLY HOSE HYDRANT ON EXISTING WATER MAIN TEMPORAD" DI n- nEE ACC -DI V (1) 2" GAL (1) 2" 90* (1) 2" GAT POLYPIG STATION (1) VERTICAL CROSS (MJxFL), SIZE TO MATCH WATER MAIN (1) BLIND FLANGE WITH 2" TAP ON TOP OF CROSS (1) TEMPORARY BLOW -OFF ASSEMBLY (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY THRUST BLOCKING NOTES: 1. THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY HOSE MUST BE DISCONNECTED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. 2. POLYPIG AND ALL DEBRIS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS VIA SANITARY METHOD PRIOR TO DISINFECTION OF NEW WATER MAIN. 3. UPON REMOVAL OF POLYPIG, REMOVE TEMPORARY BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG. 4. THE NEW WATER MAIN SHALL BE CONNECTED TO THE EXISTING SYSTEM ONLY AFTER NEW WATER MAIN IS POLYPIGGED, DISINFECTED AND SATISFACTORY BACTERIOLOGICAL SAMPLE RESULTS ARE OBTAINED. 5. THE INTERIORS OF ALL PIPES AND FITTINGS TO BE USED IN FINAL CONNECTION MUST BE SWABBED OR SPRAYED WITH A 5-6% AVAILABLE CHLORINE SOLUTION. STD. PLAN - 300.7 } PUBLIC WORKS APPROVED: DEPARTMENT POLYPIGGING NEW WATER MAINS 6/28/2( Marcm vsseucha vubh� w*rirc aemini:macm DATE WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BYTHE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. ti�Y o STD. PLAN - 300.0 va► PUBLIC WORKS WATER PLAN GENERAL NOTES DEPARTMENT MARCH 2O10 F NCO UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/g1 1114' AND 2212 ° BENDS PIPE CLAMP AND ANCHORROD L moo° L~ A J 45' BEND PIPE CLAMP AND ANCHOR ROD °L yp ° A - A - 90° BEND PIPE CLAMP AND ANCHOR ROD MINIMUM DIMENSIONS PIPE SIZE BEND VOLUME (CF) A D L 4" it Y4* BLOCKING NOT REQUIRED 221/z* 45* 90* 16 2.5' 3/4 2.0' 11 Y4 BLOCKING NOT REQUIRED 22 YZ 6" 45* 13 2.3' k4' 2.0' 90* 43 3.5' 3/4' 2.0' 11 Y4* BLOCKING NOT REQUIRED 221/z" 8" 45* 33 3.2' 3/4' 2.0' 90* 86 4.4' 3j4' 2.0' 11%* BLOCKING NOT REQUIRED 10" 221/z 13 2.3' 3j4" 2.0' 45* 64 4.0' k4' 2.0' 90* 141 5.2' V 3.5' 11 Y4 BLOCKING NOT REQUIRED 22 Y2 20 2.7' 3j4' 2.0' 12" 45* 111 4.8' Y4' 2.0' 90* 206 5.9' 1 Ya' 4.0' * D = ANCHOR ROD DIAMETER MINIMUM DIMENSIONS BASED ON FOLLOWING CONDITIONS: °� v • PIPE RESTRAINED MINIMUM 36' ON EACH SIDE OF BEND • SAFE BEARING LOAD = 1,000 SF • CONCRETE STRENGTH = 3,000 PSI L �, • CONCRETE WEIGHT = 150 PCF A • HYDROSTATIC PRESSURE = 200 PSI • TRENCH = TYPE 2 FLAT BOTTOM TRENCH WITH LIGHTLY ° CONSOLIDATED BACKFILL PER ANSI/AWWA C150/A21.50 L * ' • FACTOR OF SAFETY = 1.5 • SOIL FRICTIONAL RESISTANCE BASED ON COHESIVE I- -I GRANULAR SOIL (GC+SC), SAND, GRAVEL, CLAY MIXTURE f A CONCRETE BLOCKING DESIGN MUST BE ADJUSTED FOR NOTES: VARIANCES IN ANY OF THESE CONDITIONS. 1. NO CHANGE IN PIPE DIRECTION OR DIAMETER SHALL OCCUR WITHIN 36' OF THE VERTICAL BEND. BENDS, TEES, REDUCERS, ETC. BEYOND THE 36' LIMIT MAY BE RESTRAINED BY STANDARD CONCRETE BLOCKING PER STD PLANS 330.1 AND 330.2. 2. FITTINGS SHALL BE POLYWRAPPED AFTER INSTALLATION OF PIPE CLAMPS AND ANCHOR RODS PRIOR TO POURING CONCRETE BLOCKING. 3. PIPE CLAMPS AND ANCHOR RODS SHALL BE INSTALLED PER STD PLAN 330.4. 4. JOINT RESTRAINT SHALL BE MEGALUG SERIES 1100 OR EQUAL. 5. WATER MAIN SHALL NOT BE PRESSURIZED UNTIL ALL TRENCHING WITHIN 100' OF VERTICAL BEND IS BACKFILLED AND COMPACTED TO MINIMUM 3' COVER. 6. 90* VERTICAL BENDS SHALL ONLY BE INSTALLED WHERE GIVEN PRIOR APPROVAL BY THE CITY. 7. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 8. BACKFILL TRENCH BEYOND 90* VERTICAL BLOCK WITH CRUSHED SURFACING TOP COURSE MATERIAL COMPACTED TO 95% MDD. CRUSHED BACKFILL SHALL EXTEND 20' BEYOND BLOCK OR TO FIRM BEARING TRENCH WALL, WHICHEVER IS LESS. 9. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. CONCRETE BLOCKING STD. PLAN - 330.3 � + PUBLIC WORKS APPROVED: DEPARTMENT FOR VERTICAL FITTINGS WITH RESTRAINED JOINTS 6/28/2023 Mar"n vartucha DATE PUMic World Atlminbtrrtor 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: 3Y OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAI/R/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORS CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N 4.2.1 PIPE SYSTEMS DESIGN CRITERIA TIGURE 4.2.1.B PIPE ANCHOR DETAIL 11= 6^ MlN �^ ' A411V o a CONCRETE BLOCK -4 CONCRETE BLOCK ANCHOR _ Cf I_I ,-III-III,i�1-111_ _ -I 6" MIN. STRAP -FOOTING ANCHOR - TYPICAL) NTS z V1 o v 7 v v a , oOvaP "MIN.1 v a v v 66"" MIN. SECTION A -A NOTE: FOR SOLID WALL HDPE, PIPE MUST BE CONCRETE NTS FREE TO SLIDE INSIDE A 4' LONG SECTION FOOTING OF PIPE ONE SIZE DIAMETER LARGER. KEYEDINTO UNDISTURBED SOIL AS SHOWN II I. I �711. _I 1" MIN. DIAMETER L� STEEL ROD (STRAP) CLAMPED SECURELY TO PIPE. 6" MIN. µ p�- - CONCRETE FOOTING KEYEDINTO 1' iIN a lol o o br.v UNDISTURBED SOIL AS SHOWN x PIPE DIA. -��2 MIN. SECTION B-B NTS 2021 Surface Water Design Manual SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM 4-15 7/23/2021 CITY OF RENTON Planning/Building/Public Works Dept. w z J I � IJ_w �lo DIRECTION OF FLOW (MIN.} I 8" MIN. 6"MIN.{TYP.) UNION (TYP.I PLAN 3„MAX, 4 O 6"MIN, TO CITY METER STACKED METER SECTION 6" MIN. FREE BOXES DRAINING GRAVEL NOTES: 1_ ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTIC`. ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2, THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE- A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS -CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. t. • • PUBLIC WORKS SA* TO 2" DOUBLE CHECK VALVE STD. PLAN - 340.8 DEPARTMENT ASSLMBLY FOR IRRIGATION OR RESIDENTIAL FIRE SPRINKLER MARCH 2010 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425512 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: DRAWING NO: WA TER STANDARD DETAILS C6.32 SHEET: OF: 59 93 0 O O N N w TOP OF SLOPE (TYP) APO g510ggTR C / TRACT K (CRITICAL AREA) g I APO g51N�H�0 0 ZN11P 0 APO 3 pO REN�� q1Y EXISTNG TREE TO BE SA I/ED (TYP) LOCATOR SERVICE CALL BEFORE YOU DIG! 811 CONNECT TO EXISTING SEWER CONNECT TO EXISTING WATER TRACTA (ACCESS & UTILITY), EXISTNG OFFSIIE TREE - TO REMAIN (TYP) A PNUONO MYgv04 TRACTN_ (OPEN SPACE) CONNECT TO EXISTING STORM TOP OF SLOPE (TYP) 15' BLDG SETBACK (TYP) 15' BUFFER (TYP) / p42305�9E45LLC APO PROPER pALPAY PROPOSED WATER (TYP) PROPOSED STORM (TYP) PROPOSED SEWER (TYP) APO 4 23 OPER1E51LL0 pALPAY ApN O4ASSOC A1E5 LLC pALPAY & SCALE: 1" = 50' 0 25 50 100 STORM LEGEND STORM PIPE STORM SERVICE EXISTNG STORM PIPE STORM PIPE FLOW ARROW STORM STRUCTURE - TYPE 1 CB STORM STRUCTURE - TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERIWCE EXISTNG SEWER PIPE SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND WATER MAIN EXISTNG WATER PIPE js I IN[ WATER RTANG Ak FIRE HYDRANT ® WATER METER •� TYPE / BLOW -OFF AIR- VAC 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING `,,111111zm� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425536 S-425513 W-425513 0 N N I IN COMPLIANCE WITH CITY OF RENTON STANDARDS w w w w — SS- - - - - - SD • T `''' - - so - _ - � DEVELOPMENT ENGINEERING r�� ----SD % j CONNECT TO CONNECT TO 1 CONNECT TO — o — p — yq 112/06/2023 IRL W EXIS77NG WATER EXISTNG WATER \ Q J \ EX/SANG WATER EAB�DO:TER UTILITY EWASTEWATER UTILITY � �' N yz GAFOUR 11/09/2023 well 11 /30/2023 ' 1 REVISED PER CITY COMMENTS MJS 7/26/23 HHH SURVEYED: scu.E: VERTICAL. NAVE) 198B DATE, O 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH SY OTHERS AS NOTED HORIZONTAL: HAD 1983/1991 : PRI CITY 0 F TOWNS ON 12TH 1011112023 (� 3 REVISED PER CITY COMMENTS KEL o/11/2 HHH DESIGNEDHOLL/ HEAI/RlN 3916&3926NE12THST, RENTON, WA 98056 FlELDBOOK: DRAWN: RENTON PAGE � MARY MOORS ONE INCH DATUM DRAWING NO: CHECKED: AT FULL SCALE HOLLI HEAVR/N IF NOT ONE INCH Planning/Building/Public Works Dept. COMPOSITE UTILITY PLAN C7.01 NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: OF: HOLLI HEA VRIN 60 93 Z ti O Z O O v UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 SEE SHEET C7.03 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY O 0 N M N v `(EYMAP 0 0 0 N N K SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE -� STORM SERVICE -SD EXISTING STORURIPF STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE - TYPE 1 CS STORM STRUCTURE - TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERWCE _SS EX/STING SEWER PIPE � SEWER PIPE FLOW ARROW 0 SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND WA TER MAIN -W EXISTING WATER PIPE H C WATER F/TT/NG • FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF AIR- VAC v 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 �-425537 S-425514 1A-425514 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Lyqi PMENT ENGINEERING WASTEWATER UTILITY 12/06/2023 jstowell 11 /30/2023 N ODATE: VERnCAL• NAVD 1988 . HORIZONTAL- NAD 1983/1991 1 CITY 0 F TOWNS ON 2TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: DATUM DRAWING NO: Planning/Building/Public Works Dept. UTILITY CROSSING PLAN C7"02 SHEET: OF: 61 93 Lr) 4 SEE SHEET C7.02 N N NLO �0°50 rr 53 54 :.;II r / d' d' APN 3307801LE � � 55 56 57 58 59 • . I� g TRACT H / 41 (CRITICAL AREA) I I JEN / � \ Nr ' I TRACT L (CRI T/CAL AREA) % a 42 I / �/ I \ \ / 1�\W ,I ;.• 'a ' 39 ❑ I 4 ,. ( 305,9245�GG y \ �I ly \ , a pN 042opERTIEs 43 "OAApAY PR ` EXISTING TREE TO BE SA VED 44 52 51 50 49 4R Q (rYP) 46 ; rrH c, i [a ` h � \ v�l Pz SEE UTILITY CROSSING TABLE .�0 9PEN " N SHEET C7.04 (TYP) Y TRACT M 45 SPACE) e � u F IIzi b 3 i 9 •' NI+IN 5 9°46 \ 1 �� 5 � ❑ �iJ \ ApN ° pON WONO �\ / \ 28 29 30 24 25 26 27 31 32 33 34 O PROPOSED WATER (TYP) 35 36 37 9061 I PROPOSED SEWER (TYP) 6 ApN 4230ERT1C5 LLC PPOP M I PROPOSED STORM (TYP) ]NI p ALp AY TRACTA `. 7 ... STMENT N• 1 \ i (ACCESS & UMITY) a ApJO —3002 TRACT B "" , ... ,. ... ' L°T LINELLA, LN O9 O .. (ACCESS & UTILITY)' A :. : ' . RENTON LO 106, 2g000 7.CITY O NO• LINO 20°50 g2 I — ' L.L.A. REC- I 23 22 21 20 19 18 17 16 15 14 13 12 Jill 10 9 ApN 0423o5�Y�O4 pHUON I'' row 0425500 TRACT /V ApN 305— 0423ATES LLG ApN 055— 2 (OPEN SPA OALpAY & A DAMES UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH NO. REVISION BY 1 DATE 1 APPR SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M c� SD SD-- o—o—o CONNECT TO EXISTING WATER CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE STORY _SD EX/S NGESTORM P/PE STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE — TYPE 1 CS STORM STRUCTURE — TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERWCE _SS EX/STING SEWER PIPE ­4 SEWER PIPE FLOW ARROW 0 SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND r�:••wAf•r WA TER MAIN —W EXISTING WATER P/PE v HI WATER FITTING �• ~� Z z • FIRE HYDRANT ® WA TER METER 9 •� TYPE / BLOW_ OFF AIR— VAC 100NAL 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425538 S-425515 W-425515 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 w 0 0 N M N v 0 0 N N WASTEWATER UTILITY jstowell 11 /13/2023 kmj 141% TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 UTILITY CROSSING PLAN DATE: 0/111202J FIELDeo PAGE DRAWING NO: �7 C7.03 SHEET: OF: 62 93 O O N O N v O O O N N