HomeMy WebLinkAboutS-425503Z
ti
O
Z
O
74
SEE SHEETS C5.09-05.10
SEE
73
FOR SEWER SERVICE LINE
DES/GN (TYP)
SHEET
III f
72
SIDE SEWER
Cam•.! 5. 07
[
PER C.O.R. STD DTL 406.1,
SEE SHEET C5.31 (TYP) I
t. v �.
71 �4.
%n
17f 90.67, ROAD A =
- -
71 f 72.00, ROW 6iN
-
85
-_
SEWER MANHOLE
PER C. O.R. STD DTL 400.1,
SEE SHEET C5.31 (TYP)
86
SSMH
4
STA. 17f97.67, 12.00 L T
��o•
TYPE 1-48"
87
70
RIM 427.25
8" 1E /N 412.37 (E)
SEE SHEET SEWER
8" If /N 412.37 (S)
EASEMENT
8" IE OUT 412.27 (N)
n5, 07
l�
SSMH 5
STA. 16f81.16, 8. 6J' L T
TYPE 1-48"
RIM 422.66
8"IE/N 413.11 (E)
8" IE OUT 41J 01 (W)
EMI
430
420
410
18+50 18+00
17+50
UNDERGROUND LOCATOR SERVICE
CALL BEFORE YOU DIG.
8/g1
PROPOSED FINISH
GRADE CONTOUR
(TYP)
TRACT)
(STORM DRAINAGE)
I \
°O I \ \ \
A- - -- \
r-
I ml���
�I� � •tee
EX GROUND
SEE SHEET C5.09 CONTOUR (TYP)
\ b�
` -39r, �� \
\ \ L
PROPOSED
STREET LIGHT L
-q \'�\ . (TYP) ill
40�\ ,\ \
PROPERTY LINE \
( ) .44
a--�
t--16 60�95
CT?
16
0. f
426
'42¢ 5+0O ,
i , , ENE 01
63 ' I 62 61 60 To T C5,
III MA EE
ESN
SSI�IH 6 5E
STA. 15f 48.56, 8.28' L T
TYPE 1-48"
RIM 424.96
8" IE /N 413. 76 (SE)
8" IE OUT 413.66 (W)
TYPE 1-48"
RIM 425.90
8" 1E /N 414.07 (S)
10' UTILITY 8- IE OUT 413.97 (NW)
EASEMENT
(TYP)
SEE SHEETS C7.02-C7.04 FOR
UTILITY CROSSING NFORMAT/ON.
►,►LLv�[�i7����-,A�G�L-'iZ►ilG��7
� 440
O
430 ti
W
Z
W
420 O
O
H
Z
Z
V
410 Q
17+00
16+50
16+00
15+50
1
REVISED PER CITY COMMENTS
MJS
7/26/23
HHH
SURVEYED:
3Y OTHERS
2
REVISED PER CITY COMMENTS
KEL
9/12/23
HHH
DESIGNED:
ROLL/ HEAVR/N
3
REVISED PER CITY COMMENTS
KEL
10/11/22
HHH
DRAWN:
MARY MOORS
CHECKED:
ROLL/ HEA VR/N
NO.
REVISION
BY
DATE
APPR
APPROVED:
ROLL/ HEA VR/N
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL• NAVD 1988
HORIZONTAL- NAD 1983/1991
DATU M
KEY MAP
/Y
SEWER LEGEND
0
O
SEWER P/PE
SEWER SERVICE
SEWER EASEMENT
EXISTING SEWER PIPE SCALE: 1 " = 3 0 )
SEWER P/PE FLOW ARROW
SEWER STRUCTURE 0 15 30 60
SEWER CLEANOUT
GENERAL NOTES
1. ALL CONSTRUC7ON SHALL BE /N ACCORDANCE WITH CITY OF RENTON STANDARD SPEC/F/CATIONS.
2. WHERE THE WATER MAIN /NSTALLAIJON CROSSES OVER SANITARY SEWERS, THE MINIMUM VER77CAL
SEPARA77ON SHALL BE 18 INCHES, OR CONSTRUCTON SHALL BE /N ACCORDANCE WITH DOE
CRITERIA FOR SEWAGE WORKS DESIGN (SEE DETAILS)
3. ALL SIDE SEWER TEES SHALL BE FIELD LOCATED.
4. CONTRACTOR SHALL FIELD VERIFY CONNECAON TO EXISANG PIPE FOR PROPER AS-BU/L T
ELEVATION PRIOR TO CONSTRUCTION OF MANHOLE OVER LINE.
SIDE SEWER NOTES
1. MIN/MUM SLOPE ON 6" S/DE SEWER LINES /S 2Z
2. UNITS NUMBERS MARKED WITH A "*" WILL HA VE BACKWATER VAL VfS INSTALLED ON THE
PRIVATE SIDE (UPSTREAM) OF THE CLEANOUT AT THE END OF THE SIDE SEWERS.
3. SEE SEWER SERVICES PLAN ON SHEET C5.09 AND C5.10 FOR SIDE SEWER /NFORMA AON.
CITY OF
RENTON
Planning/Building/Public Works Dept.
00
O
N
N
V
0
0
0
N
N
1 0/11/23
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
PLANNING
DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
S-425503
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING 0 WASTEWATER UTILITY
yqi 12/06/2023 jstowell 11 /13/2023 L�
N
H
DATE:
O
TOWNS ON 12TH 101111202J
3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK:
PAGE:
SA NITA R Y SEWER PLAN & PROF/LE DRAWING NO: O
C5.02
ROAD A (15+00 -END) SHEET: OF:
38 93