Loading...
HomeMy WebLinkAboutS-425506Z ti O Z O O v 450 430 420 N N SEE SHEET 05.04 44 1_ 45 M 3- -1 SEWER MANHOLE 54 59.91, ROW 4 = - - - PER C. O.R. STD DTL 400.1, 12f89.35, ROAD A SEE SHEET C5.31 TYP SEE SHEETS C5.09-05.10 - - = _ 'LT FOR SEWER SERVICE LINE DES/GN (TYP) 46 �-� SSMH 9 , %� STA. 12f83.35, 5.00 IJ 30 RIM 430.18 4 A3 -` SIDE SEWER I I / PER C. O.R. STD DTL 406.1, 47 SEE SHEET C5.31 (TYP) _ �-r \ _JI 8.1E IN 415.39 (S) 29 8" 1E IN 415.39 (W) 8" 1E /N 415.39 (E) 8" lE OUT 415.29 (N) 48 _ 28 \ STA. 52*76.26, 8. 92' L T TYPE 1-48" R/M 434.58 8" IF OUT 426.39 (E) 15' BSBL TRACT L (CRITICAL AREA) SEWER EASEMENT ' 182LF 8" PVC 00.0604 TRACTA (ACCESS & UTILITY) 26 25 I 24 1, TRACT M (OPEN SPACE) 22 / 23'`, SEESHEETS C7.02-C7.04 FOR UT/L/TYCROSS/NG NFORMAT/ON. 10' UTILITY EASEMENT (TYP) SEE SHEET PROPOSED FINISH - C5.03 GRADE CON��) 52fOQ,_ � � � - '.r. PROPOSED STREET LIGHT (TYP) SEE SHEET C5.08 __ L_ IO TRACTN (OPEN SPACE) , I : `• 115 00 � I ,,, . O ►IINI LL BSBL TYP o o PROPERTY LINE (TI I� 51 f37.96, ROW 4CD = N z 79f97.66, NE 12TH ST LQ o EX GROUND CONTOUR (TYP) 1 q -50f00.00, ROW 4 = 80f 00.00, NE 12TH ST Ln I �z O U � U ►w vLL J/7LC / (i.7, Vl3 HIGH T STA: 51f46.93 LOW PT ST : 50f4>.99 H/G PT EL: 437.21 LOW PT 434.72 P STA: 51f37.96 PV/ STA: 50*50.00 I/l EL: 437.81 PW EL: 434.39 O 80.00' VC O 0 50.0 VC o EXISTING GROUND ' • ® ROAD �' (TYP) j j I I I I o j c:i �i � W W .� d, � I . O ^ WW RI RI mO�3 O� Q PROPOSED GRADE o ®ROAD (TYP) 388z -2.00% ' ^o nn� / _246.9 . . 0 i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 006 o „ Pv0 �L . . . so^ ^ ^ ^ ROW4 (� �, �I W EX/STING ELEV. PROPOSED ELEV. HOR/Z. SCALE. 1 "30' ® ROAD (TYP) ® ROAD (TYP) VERT. SCALE' 1 "=5' 55+00 54+50 54+00 53+50 53+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 52+50 52+00 51 +50 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS Ora 51 +00 50+50 M J S 7/26/23 HHH SURVEYED: BY OTHERS K E L 9/ 12/23 HHH DESIGNED: HOLL/ HEAVR/N KEL 10/11/22 HHH DRAWN: MARY MOORS CHECKED: HOLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N 50+00 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL* NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. SEWER LEGEND 0 0 SEWER P/PE SEWER SERVICE SEWER EASEMENT EX/STING SEWER PIPE SEWER PIPE FLOW ARROW SEWER STRUCTURE SEWER CLEANOUT GENERAL NOTES tiF SG� SFT e�L O I I I I _7F NE 2TH ST `(EYMAP SCALE: 1" = 30' 0 15 30 60 1. ALL CONSTRUCAON SHALL BE /N ACCORDANCE WITH CITY OF RENTON STANDARD SPEC/F/CATONS. 2. WHERE THE WATER MAIN /NSTALLATON CROSSES OVER SANITARY SEWERS, THE MINIMUM VERTCAL SEPARATON SHALL BE 18 INCHES, OR CONSTRUCTON SHALL BE /N ACCORDANCE WITH DOE CRITERIA FOR SEWAGE WORKS DESIGN (SEE DETAILS). 3. ALL SIDE SEWER TEES SHALL BE FIELD LOCATED. 4. CONTRACTOR SHALL FIELD VERIFY CONNECTON TO EXISTING PIPE FOR PROPER AS -BOIL T ELEVATON PRIOR TO CONSTRUCTON OF MANHOLE OVER LINE. SIDE SEWER NOTES 1. MIN/MUM SLOPE ON 6" SIDE SEWER LINES /S 2% 2. UNITS NUMBERS MARKED WITH A "*" WILL HA VE BACKWA TER VA Vf-5 INSTALLED ON THE PR/VA TE SIDE (UPSTREAM) OF THE CLEANOUT A T THE END OF THE S/DE SEWERS. 3. SEE SEWER SERVICE PLAN ON SHEET C5.09 AND C5.10 FOR SIDE SEWER /NFORMATON. O O N N 10/11 /23 conCIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425506 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING WASTEWATER UTILITY yqi 12/06/2023 jstowell 11 /13/2023 ' N ODATE: TOWNS ON 12TH 10/11/2023 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: SA NITA R Y SEWER PLAN & PROF/LE DRAWING N0: O C5.05 � ROW 4 SHEET: OF: 41 93