Loading...
HomeMy WebLinkAboutS-425508Z ti O Z O EX GROUND PROPERTY CONTOUR (TYP) EX OFF51TE TREE � LINE TO REMAIN TYP .14 (TYP) ( ) -SEE SHEETS C5.09-05.10 FOR SEWER SERVICE LINE DESIGN (TYP) J 76 75 174 73 72 71 ill _ Qj 70f00. 0%��1 BEGIN ROAD _ 0wu TRACT `(� �` ` � rxti°� �ti6 �, (CRI77CAL AREA), TOP OF SLOPE BEGIN N �o � I I SEWER EASEMENT x i 42411 77 78 79 80 1 81 15' SETBACK (TYP) SSMH 3 71- 00 �162LF I I -*3t 8" PVC 1 0.0185 82 83 SEEC5.02 SHEET II STA. 70f21.00, 7.00' RT STA. 17f97.67, 12.00' L T TYPE 1-48" TYPE 1-48" RIM O_A . dd 422.84 8" lE /N �89.-�92 (S) 408.79 RIM 5�426.79 8" lE OUT 4i98.�'2-(NE)408.,39 8" lE /N 7-(E)411.84 8"lE/N 41-2 6�(S)411.89 8" /F OUT , (N)411.79 SEE SHEETS C7.02-C7,04 FOR UTILITY CROSSING NFORMAT/ON. 1-- PROPOSED F/N/SH GRADE CONTOUR (TYP) 70 69 68 I / 671 �; .d. STA. 72f82.19, 7.00' RT TYPE 1-48" RIM 4Z25 z28 425.20 8" If OUT 2- (N) 416.50 89 90 EX TREE - TO BE SA VfD (TYP) SIDE SEWER PER C.O.R. STD DTL 406.1, SEE SHEET C5.31 (TYP) TRACTL (CR/T/CAL AREA) SEWER MANHOLE PER C. O.R. STD DTL 400.1, SEE SHEET C5.31 (TYP) =72f87.77 '\ / r-A In nn An �75 7.5' �a1J0 15' BSBL HIGH PT STA: 71f80.15 HIGH PT EL.• 427.11 PW STA: 71f72.00 PW EL: 427.82 . 100.00 VC 0 0 EX/STING GROUND v v p v v O 0ROAD (TYP) q �Q _N y' PROPOSED GRADE 0 ROAD �' (TYP) �L,4 . 70100 = ROW 6 EL: 422. 00 ROAD IMPROVEMENT . . . . . 0 0469 98LF PVC @� 8» 0.0185 162LF *&F 8" PVC ®� WWW ao 0o ao EXISTING ELEV. . zr 0 ROAD � (TYP) RO 6 PROPOSED ELEV. Ui CIO ao 9 ROAD (TYP) VERT. SC E.• 1 "-5' 70+00 70+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ SEWER LEGEND 0 0 MY Z SEWER P/PE SEWER SERVICE SEWER EASEMENT EX/STING SEWER PIPE SEWER P/PE FLOW ARROW SEWER STRUCTURE SEWER CLEANOUT `(EYMAP SCALE: 1" = 30' 0 15 30 60 GENERAL NOTES 1. ALL CONSTRUCAON SHALL BE /N ACCORDANCE WITH CITY OF RENTON STANDARD SPEC/F/CAAONS. 2. WHERE THE WATER MAIN INS TALLA77ON CROSSES OVER SANITARY SEWERS, THE MINIMUM VERACAL SEPARAAON SHALL BE 18 INCHES, OR CONSTRUC77ON SHALL BE /N ACCORDANCE WITH DOE CRITERIA FOR SEWAGE WORKS DESIGN (SEE DETAILS). 3. ALL SIDE SEWER TEES SHALL BE FIELD LOCATED. 430 4. CONTRACTOR SHALL FIELD VERIFY CONNECTION TO EXISTING PIPE FOR PROPER AS -BOIL T ELEVATION PRIOR TO CONSTRUCAON OF MANHOLE OVER LINE. SIDE SEWER NOTES 420 410 71 +00 71 +50 72+00 72+50 73+00 73+50 SURVEYED: SCALE: 1988 BY OTHERS HORIZONTAL AL AD 1 83/1 DESIGNED: AS NOTED HORIZONTAL• NAD 1983/1991 ROLL/ HEA VR/N DRAWN: MARY MOORE ONE INCH DATUM CHECKED: AT FULL SCALE ROLL/ HEA VR/N IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: L/ HE l/R/N SCALE ACCORDINGLY ROL CITY OF RENTON Planning/Building/Public Works Dept. 1. MIN/MUM SLOPE ON 6" S/DE SEWER LINES /S 2% 2. UNITS NUMBERS MARKED WITH A "*" WILL HA VE BACKWA TER VAL Vf-5 INSTALLED ON THE PR/VA TE SIDE (UPSTREAM) OF THE CLEANOUT A T THE END OF THE S/DE SEWERS. 3. SEE SEWER SERVICE PLAN ON SHEET C5.09 AND C5.10 FOR SIDE SEWER /NFORMA AON. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425508 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 SA NITA R Y SEWER PLAN & PROF/LE ROW 6 CONSTRUCTION RECORD DRA WINGS 0 0 N O N v 0 0 0 N N N DATE: O 0/111202J FIELDeo PAGE DRAWING NO: C5.07 SHEET: OF: 43 93