Loading...
HomeMy WebLinkAboutR-425521Z ti O Z O O v EE SHEET C4.06 STA. 13t56.81, 9.25' L T TYPE 1, 7QhW *29:ff' 428.53 6" If /N 4z-29 E,r(W) 425.53 12" 1E OUT -4z-15 lzr (E) 425.13 SEE SHEETS C4.10-C4.11 FOR STORM SERVICE DESIGN (TYP) m/ AQnAnccn 1'Aenc 9%, V 430 L� I W W I I QO� 420 W Z I V I Q 410 I I ,5/A. 7gt7U.bb, U.UU TYPE 1, &M 436if 429.49 12 If IN 0 (W) 425.89 12" /F OUT -4,9610 (E) 425.89 15+00 14+50 14+00 13+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 ffbl-�`29-4;7 429. 00 C4, 03 'T #Z/ YZ 12 If IN -4z` * 9-; (W) 424.95 12 lE /N 422;50-(W) 421.52 12" 1E OUT 4z-4:9-;(E) 424.95 12" If /N 0-a;� 39- (S) 421.52 12" 1E OUT4z-�F56 (E)421.52 STORM CLEANOUT PER C. O.R. STD DTL 226, SEE SHEET CA33 (TYP) STA. 10t66.00, 9.25" RT TYPE 1, VANED GRA TE A'M 4�- &9-427.01 6"IE/N 42. ) 12" If OUT Of A (W) SEE SHEET C4.O8 SEE SHEET CB 14 C4.08 STA. 10t66.00, 9.25' L T TYPE 1, VANED GRATE fr9- 426.73 12" If IN :9 (E) 423.33 12" /F IN Ago * (S)-423.28 (SW) 12" 1E OUT (N) 423.28 13+00 12+50 12+00 11+50 NO. I REVISION I BY I DATE I APPR 11+00 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N APPROVED: ROLL/ HEA VR/N PROPOSED FINISH GRADE CONTOUR (Typ) EX GROUND CONTOUR (TYP) 10100.00, ROAD A = 81*89.10, NE 12TH ST PROPOSED STREET LIGHT (TYP) 10+50 SCALE: I AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 10+00 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM m 430 420 410 CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP SCALE: 1" = 30' STORM LEGEND STORM PIPE STORM SERVICE STORM EASEMENT EXISTING STORM PIPE STORM PIPE FLOW ARROW STORM STRUCTURE - TYPE 1 CB STORM STRUCTURE - TYPE 2 CS STANDARD NOTES 1. ALL STORM FRAMES SHALL BE VANED GRATES PER C.O.R STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET C4.33. 2. STORM FRAMES WITHIN SAG CURIES AT LOW POINTS SHALL BE 91-DIREC77ONAL VANED GRATES PER C.O.R. STD DTL 204.3. SEE DETAIL SHEET C4.33. 3. PIPE MATERIAL SHALL CONFORM TO THE 2022 RSWOM CHAPTER 4, SECTION 4.2.1. AND TABLE 4.1.1. A2. 4. SEE SHEET C4.10 AND C4.11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MAY BE CLASS 52 DUCTILE IRON IF DES/RED. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,CORE PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425521 IN COMPLIANCE WITH CITY OF RENTON STANDARDS TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 ROAD & STORM DRAINAGE PLAN & PROF/LE ROAD A (START- 15+00) CONSTRUCTION RECORD DRA WINGS 0 0 0 N N 1 N ti DATE: O 0/111202J FIELDeo PAGE DRAWING NO: �ijh C4.01 SHEET: OF: 21 93