Loading...
HomeMy WebLinkAboutR-425523Z ti O Z O 450 „m 430 420 STA. 19f66.50, 0.00' TYPE 1, SEE M0 4'+429.40 426.55 6" /F /N A*T 4 (S) SHEET 426 55 6" 1E /N 4-4 04 (N) PROPERTY LINE 12" /F OUT -fir. 64 (E) (TYP) C4, 05 425.80 23 22 21 20 I' 1�1,19 18 17 I EX OFFSITE TREE L TO REMAIN (TYP) 18f 11.01, ROW 2 =01 51 f37.96, ROW 4 ORION MAIN APN 042E MYgVO4i� - o z d PHUON I y TRACT M `L (OPEN SPACE) 171LF -F 12" DI ® 9.• B6-,qB- 0.0085 I 9 8 SEE SHEET TRACT N C4. 05 (OPEN SPACE) 1 ®�117�III� SEE SHEET C4.01 � 1 l N�{IN OI/ �a F o SEE SHEET STA. 11f41.29, 8.35" L T '; C4, 01 TYPE 2-48 ift 4-98 59.427.92 12" 1E /N 4,49 66-(W) 421.52 12" If /N 60 (S) 421.52 12" If OUT 1111 #B- (E) 421.52 PROPERTY LINE PROPOSED STREET (TYP) LIGHT (TYP) SEE SHEETS C4.10-C4.11 EX GROUND CONTOUR (TYP) 10' UTILITY FOR STORM SERVICE LINE CB EASEMENT (TYP) DESIGN (TYP) ✓O STA. 21,4665.02, 0.00' 16115 14 - I - TYPE 1, VANED GRATE 1 1 I ! 1 �4fM 4z'3.-9-� 423.20 .. 20f 00. 00, ROW 1 = ' 13 I , 6" If /N -�-99 (S) 420.60 �� 11 f 41.29, ROAD A 11 10 6H 1E IN �.� (N) 420.60 I C12 C-900-v-i'i'-sir 0.0928 II 1 � 8" IE /N-4z-B. 6 (E) 420.36 24LF 151LF �� 12" 1E OUT �,r (W) 420.15 12" Dl21 �._�I f75.50 0 _ I END ROAD STORM EASEMENT 3 30A 21 �00 _ STA. 21f84. 69, 0. 00' ROW 1 N T�423.58/NG LID 16LF a - REF 8" D/ 8" lE /N 420.86 (S)420.88 ®� _ 8" lE OUT 420.86 (W)420.88 a. 426 I TRACT O 10.0320 I / 2305, TES 103LF „ 04ASSOOIA I (OPEN SPACE) 69 1B4EF 8 Of i I! 0.0108 CATCH BASIN TYPE 2 SEE SHEET C 3 (TYP)1' 4 ! 3 �� I 2 1 SEE SHEET C4.08 FOR PROFILE I I PROPOSED FINISH 0 11 CATCH BASIN TYPE 1 GRADE CONTOUR STA. 11f4129, 16.15' RT PER C.O.R. STD DTL 200, (TYP) SEE SHEET C4.33 (TYP) TYPE 2-48'; Ift 2' 427.92 STORM CLEANOUT 15 STORM ESMT 6" If /N 424 97 (SE) 421.92 PER C.O.R. STD DTL 226, 12 If /N z (E) 419.22 SEE SHEET C4.33 (TYP) 12" 1E /N A1�(W)419.22 15" IE OUT0:9 111 (N)418.97 SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. HIGH PT STA: .. 18f33.49 . . . . . . . . . . . . . . HIGH PT I L: 437.51 PW STA: 18*50.00 PW EL: 437. 98 60.0 VC . . �^ �h 18f 11.01 = ROW 2 �i �i Lu Lu 51f37.96 = ROW 4 EL: 4J7.20 PROPOSED GRADE EX/STING GROUND .00A, 0 ROAD (TYP) ® ROAD (TYP) � N mhrn o . c� ., W . 1? \ . .O . O�j�G� . c.� . °e NN N o�NN PROPOSED ELEV. 0 ROAD f (TYP) RO 2 o EX/STING ELEV. HOR/Z. SC E. 1 �� 30' 1 N L j W W L W I W ® ROAD (TYP) INERT. SCA E. 1 =5 A 450 440 440 430 430 420 420 410 18+00 18+50 19+00 19+50 20+00 20+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 h o Q PROPOSED GRADE s N W 9 ROAD f (TYP) W In 1 EX/STING GROUND mo"� oQ W \ 0 ROAD (TYP) o . . . . . 18LF . f7EF 8 Dl 0. 0.0320 . . . . . . . . . 151LF -1�5z''EF 12" DI 0.9.-8859- 1 O 0.0062 N N . W = W O o C3 _�IW�, z . . . . . . . 0000 �0 __ o ��a N PROPOSED ELEV. . 0 Q Q o a 0 ROAD f (TYP) RO 1 EX/STING ELEV. 9 ROAD f (TYP) HOR/Z. SCALE- 1 "=30' "-5' �' ��" � � W � �' v oo INERT. SCA E. 1 tiF SGti sFT e�G O �C NE 92TH ST `(EYMAP SCALE: 1" = 30' 440 0 15 30 60 STORM LEGEND 430 • 420 410 20+00 20+50 21+00 21+50 22+00 22+50 4 FIELD CHANGE #1 DNV 5/1/24 LBS SURVEYED: SCALE: BY OTHERS vERncAL: NAw lsae 5 STAIR REVISION KEL 7/ 17/25 HHH AS NOTED HORIZONTAL- NAD 1983/1991 DESIGNED: 6 STAIR REVISION - REVISED PER CITY COMMENTS KEL 8/19/25 HHH ROLL/ HEAVR/N 7 STORM REVISION KEL 8/20/25 HHH DEW"` MARY MOORE ONE INCH DATUM 8 STORM REVISION M J S 8/25/25 HHH CHECKED: AT FULL SCALE 6 STAIR REVISION - REVISED PER CITY COMMENTS KEL 9/16/25 HHH ROLL/ HEAI/R/N IF C NOT ONE INCH APPROVED: SCALE ACCORDINGLY NO. REVISION BY DATE APPR ROLL/ HEAVR/N STORM P/PE STORM SERVICE STORM EASEMENT EX/STING STORM PIPE STORM P/PE FLOW ARROW STORM STRUCTURE - TYPE 1 CB STORM STRUCTURE - TYPE 2 CB STANDARD NOTES 1. ALL STORM FRAMES SHALL BE VANED GRA TES PER C. OR STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET C4.33. 2. STORM FRAMES W/TH/N SAG CURIES AT LOW POINTS SHALL BE 81-DIREC77ONAZ VANED GRA TES PER C. O. R. STD DTL 204.3. SEE DETAIL SHEET C4.33. 3. PIPE MA TER/AL SHALL CONFORM TO THE 2022 RSWDM CHAPTER 4, SECTION 4.2.1. AND TABLE 4.1.1.A2. 4. SEE SHEET CA 10 AND CA 11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MA Y BE CLASS 52 DUCT/LE IRON /F DES/RED. 9AII CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425523 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O O O N N N DATE: O CITY 0 F TOWNS ON 12TH 812012025 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: DRAWING NO: Planning/Building/Public Works Dept. ROAD & STORM DRAINAGE PLAN & PROFILE C4. 03 ROW 1 & ROW 2 SHEET: 23 OF 93