HomeMy WebLinkAboutR-425524Z ti O Z O 430 A 410 a 40 EX GROUND CONTOUR (TYP) 41 o 42 SEE SHEET C4.01 PROPOSED STREET LIGHT (Ty i, 12189.35, ROAD A = 54f59.91, ROW 4 0 1,' W o ROI�i' z NIA N CA W CA TCH BASIN TYPE 1 J �o PER C.O.R. STD DTL 200, SEE SHEET C4.33 (TYP) V CB 128 6 4 29, 11 15' RT SEE SHEET TYPE 2n48" 428°78 C4.01 15" IF /N 6 (5) 418.23 12" IE /N "-,� (E) 418.38 12" If /N 4 �& 99 (W) 418.38 15" If OUT 4A8 778 (N) STORM CLEANOUT 41823 PER C.O.R. STD DTL 226, SEE SHEET C4.33 (TYP) 43 CATCH BASIN TYPE 2 I PER C. O.R. STD DTL 20=1, SEE SHEET C4.33 (TYP) 4445 03085Ro W3 ff9., 400., ROW3A m F31 82LF1�F 12" C-900 40.0305�34 f 32 p 33, J 10' UTILITY EASEMENT (TYP) STA. 30f98.50, 0.00' TYPE 2-48'; ffM 4zL,7 66r 426.78 12 If /N -Az . (E) 420.88 12" If OUT 44. ziB (W) 420.88 0 ^Q 1 va Q Q� \ oo N PROPOSED GRADE q 9 ROAD �' (TYP) II o N ASPHAL T THICKENED EDGE TO BE ADDED TO END OF ROW 3, EX/STING GROUND . �.39,' nog . TO DIRECT DRAINAGE TO CB 21 0 ROAD � (TYP) 31f75. 50 = ROW 3 - EL: 42 58 - END ROD IMPROVEMENT ULF . 11j,3�F12" C900 441�2 C900 \ C900 -' �-0-80.�09057F98 - f12" 0305 0\ I IIIWW W ro�v � Lv PROPOSED ELEV. . . . . . . . 0 ROAD � (TYP) ROW 3 (E ST- WEST) EXISTING ELEV. HOR/Z. SCALE- 1 "=30' . . 0 ROAD � (TYP) VERT. SCA E.• 1 "5' 30+00 30+50 31+00 31+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 41f24.88 TOP OF SLOPE END ROAD T (TYP) PROPOSED FAMISH GRADE CONTOUR (TYP) I _ EX TREE TRACT C TO BE SAVED (TYP) \ TRACTG (OPEN SPACE) MLF 3WEF 12" C-900 42LF 0.0115 4MF 12" C900 00 o 10.0079 CN PROPERTY LINE (TYP) 15' � _ I ' 31f75.50 (� END ROAD CS 21 STA. 31f74.00, 0.00' TYPE 1, VANED GRATE ffM 4z * 6� 423° 64 35 36 37 �6" IE /N 4T* (5)422.04 1 / 12" IE OUT f�. 66r (W)421.59 I ASPHAL T THICKENED EDGE 0 20 TO BE ADDED TO END OF ROW 3, STA. 31f32.50, 0. TO TO DIRECT DRAINAGE TO CB 21 TYPE 1, SEE SHEETS CA 10-C4.11 -4i'fbt-41& 90 425.81 FOR STORM SERVICE LINE 12" IE /N 5 (E)421.26 DESIGN (TYP) 6" IF /N 421.76 (N) 6" PVC PIPE ADDED IN CONSTRUC110N 12" IF OUT 22A (W)421.26 440 440 430 430 420 420 410 410 32+00 32+50 it N N SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. . . . . . . . . . . . . . . Z PROPOSED GRADE 0 9 ROAD � (TYP) II n o EX/STING GROUND o �' GRADE BREAK I h 0 ROAD � (TYP) o 41 f29. 55 oaoN 1.139' `�Z� EL: 429.13 W . �W N t k PROPOSED ELEV. 0 ROAD � (TYP) RO 3 (NORTH -SOUTH) EXISTING ELEV. HOR/Z. SCALE- 1 "=30' 9 ROAD � (TYP) VERT. SCALE- 1" 5' of a 40+00 40+50 41+00 SURVEYED: BY OTHERS DESIGNED: HOLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HEA VR/N BY DATE APPR APPROVED: HOLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM l r- `(EYMAP SCALE: 1" = 30' 440 0 15 30 60 STORM LEGEND STORM P/PE STORM SERVICE - - STORM EASEMENT SD EX/STING STORM PIPE ­4 STORM PIPE FLOW ARROW 430 10 STORM STRUCTURE - TYPE 1 CB 0 STORM STRUCTURE - TYPE 2 CB STANDARD NOTES 420 410 1. ALL STORM FRAMES SHALL BE VANED GRA TES PER C. O.R STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET C4.33. 2. STORM FRAMES W/TH/N SAG CURIES AT LOW POINTS SHALL BE 31-DIREC77ONAL VANED GRA TES PER C. O. R. STD DTL 204.3. SEE DETAIL SHEET CA33. 3. PIPE MA TER/AL SHALL CONFORM TO THE 2022 RSWOM CHAPTER 4, SECTION 4.2.1. AND TABLE 4.1.1.A2. 4. SEE SHEET CA 10 AND C4.11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MA Y BE CLASS 52 DUCT/LE IRON /F DES/RED. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425524 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 0 0 N N 41f50 42+00 N DATE: O CITY 0 F TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: ROAD & STORM DRAINAGE PLAN & PROFILE DRAWING N0: O Planning/Building/Public Works Dept. (,4, Q4 � RO W 3 (E- W & N-S) SHEET: OF: 24 93 CONSTRUCTION RECORD DRA WINGS