Loading...
HomeMy WebLinkAboutR-425526Z ti O Z O O v 6" CLEANOUT 2SEE SHEET W/ ATR/UM GRATE F 6" DI 50f00.00, ROW 5 = zv. 60 22 44 --0 9*9 0. 0131 C4, 02 6" 1E-420.44 14f49.57, ROAD A I EX GROUND 66 65 64 63 62 61 60 Q CONTOUR (TYP) / I \ • \ 119LF - I 65LF Q � ARBOR/ST TO BE ON -SITE 51f77.31 �F 12'" C-900 -661 12" PVC �\ DURING DISTURBANCE WITHIN END ROAD -�'-B.-B850 0.0065 � \ ¢26 � 0 / CATCH BASIN TYPE 2 SAVED TREE DR/PLINE TO I ; 0.0158 \ PER C.O.R. STD DTL 201, i . �" s� \ SEE SHEET C4.33 (TYP) PROVIDE GU/DANCE TO THE ACT M %j'• ; a a ,a.. \ CONTRACTOR TO ENSURE THE HEALTH OF THE TREE /S NOT (o N SPA CE) \ \ 0 �� COMPROMISED \ ° 428\ / STA. 14f49.57 16.15' RT EX TREE a . a 1 00 TYPE 2-48" 1 TO BE SA l/ED 15' BSBL ` . -i?Ji6�' i. 82- 426.33 (TYP) (T�) •� 4. /1 18" lE /N �58- (5) 417.23 / _ 12" IE /N 4 �& 08 (W) 41788 18" lE OUT -4158 (N) 417.23 41 Wo PROPOSED F/NISH QQ�EQ TRA CT L 11 / 1 \ GRADE CONTOUR RE (CR/T/CAL AREA) 53 ' 54 55 56 I ° I 5 758 a 59 " (TYP) AL TERNATE DISCHARGE LOCAT/ON FOR ROOF CS 17 CS 16 SEE SHEET DRAINS ONL Y OF LOTS 53-56 TO DISCHARGE TO , TRACT L. DISCHARGE TO ROCK PAD AS SHOWN TYPE 1,1*68.86VANED GRATE TYPE 20 8', 44, 0.49 LT C4, 01 CATCH RA SIN TYPE 1 A -F3 96 - 423.80 90 hF&zf6 426.12 10' UTILITY PER C.O.R. STD DTL 200, 420.10 6" If /N 4--V 3 (5) 12" lE IN J (W) 418.92 EASEMENT (TYP) SEE SHEET C4.33 (TYP) 42010 6" If /N 3 (W) 6" If /N 0 :7;74 (5) 419.42 SEE SHEETS CA 10-C4.11 STORM CLEANOUT 12 IE OUTS (E) 12" If OUT 41:9z-3 (E) 418.92 FOR STORM SERVICE LINE PER C. O.R. STD DTL 226, 419.70 DESIGN (TYP) SEE SHEET C4.33 (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMA T/ON. 430 420 410 52+50 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ EX/STING GROUND 0 ROAD � (TYP) i 51f68.86 EL: 42J 96 E BREAK 51f77.31 / 424.05 i 1.00 �L EX/STING ELEV. 0 ROAD � (TYP) PROPOSED ELEV. 0 ROAD (TYP) 52+00 PROPOSED GRADE 0 ROAD (TYP) 51 +50 M&NE •► 119LF -2.009 m liuMmE RO 5 VERT. SCA Er- 1 " 5' 51 +00 ro 50+50 65LF 50+00 SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N 430 420 410 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M `(EYMAP '� N SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM P/PE STORM SERVICE - - STORM EASEMENT EX/STING STORM PIPE STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE - TYPE 1 CB 0) STORM STRUCTURE - TYPE 2 CB STANDARD NOTES 1. ALL STORM FRAMES SHALL BE VANED GRATES PER C. OR STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET C4.33. 2. STORM FRAMES WITH/N SAG CURIES AT LOW POINTS SHALL BE 91-DIREC77ONAL VANED GRATES PER C.O.R. STD DTL 204.3. SEE DETAIL SHEET C4.33. 3. PIPE MA TER/AL SHALL CONFORM TO THE 2022 RSWDM CHAPTER 4, SECTION 4.2.1. AND TABLE 4.1.1.A2. 4. SEE SHEET C4.10 AND C4.11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MA Y BE CLASS 52 DUCTILE IRON IF DES/RED. 5/S/25 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425526 IN COMPLIANCE WITH CITY OF RENTON STANDARDS O O O N N N DATE: O CITY 0 F TOWNS ON 12TH 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: DRAWING NO: Planning/Building/Public Works Dept. ROAD & STORM DRAINAGE PLAN & PROFILE C4. 06 Q) ROW 5 SHEET: OF: 26 93 CONSTRUCTION RECORD DRA WINGS