Loading...
HomeMy WebLinkAboutR-425526O v EX GROUND CONTOUR (TYP) ,,, 430 420 TRACT M (OPEN SPACE) EX TREE TO BE SA l/ED (TYP) 15' BSBL (TYP) 50100. 00, ROW 5 = -\ 14f 49.57, ROAD A �a - 66 65 64 63 I 62 61 60` 51f77.31 ' 119LF 12" C-900 66LF 12" PVC �\ END ROAD 00.0050 00.0174 \ 4 - ..F . ROW 5 -T _ o TRACT L (CRITICAL AREA) CATCH BASIN TYPE 1 PER C. O.R. STD DTL 200, SEE SHEET C4.33 (TYP) STORM CLEANOUT PER C. O.R. STD DTL 226, SEE SHEET C4.33 (TYP) A53 154 55 56 I 57 58 9 STA. 51f68.86, 0.00' RT STA. 50f49.44, 0.49' L T TYPE 1, VANED GRATE TYPE 2-48" RIM 42J 96 RIM 426.36 6" 1E IN 420.33 (S) 12" 1E /N 419.23 (W) 12" If OUT 419.83 (E) 6.1E IN 419.73 (S) 12"IEOUT 419.23(E) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. EXISTING GROUND 0 ROAD � (TYP) i BADE BREAK 51f68.86- PROPOSED GRADE EL: 42J 96 0 ROAD � (TYP) E BREAK 51f77.31 / 424.05 _2009 /19LF 12" PVC 010. 59 SEESHEET C4.02 IF #90 vo 1 \ NI SEE SHEET C4.01 10' UT/L/TY EASEMENT (TYP) - SEE SHEETS C4.10-CA 11 FOR STORM SERVICE L/NE DESIGN (TYP) CA TCH BASIN TYPE 2 PER C.O.R. STD DTL 201, SEE SHEET C4.33 (TYP) L'L) ✓ STA. 14*49.57, 16.15' RT TYPE 2-48" RIM 427.52 18 IE /N 417. 58 (5) 12" /F IN 418. 08 (W) 18" 1E OUT 417.58 (N) PROPOSED FINISH GRADE CONTOUR (TYP) Eml 430 � hq� 1 L-- -I- I - 420 410 = ��, �,�,� mho 410 gQ Liz EX/STING ELEV 0 ROAD � (Typ) R0 5 . PROPOSED ELEV. HOR/Z. SC E. 1 "=30' 0 ROAD (TYP) VERT. SCA E.• 1 " 5' N 52+50 52+00 51 +50 51 +00 50+50 50+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/g1 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM tiF SG� SFT e�L O -44 NE 2TH ST `(EYMAP SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM P/PE STORM SERVICE - - STORM EASEMENT EX/STING STORM PIPE STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE - TYPE 1 CB 0) STORM STRUCTURE - TYPE 2 CB STANDARD NOTES 1. ALL STORM FRAMES SHALL BE VANED GRATES PER C. OR STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET CA33. 2. STORM FRAMES WITH/N SAG CURIES AT LOW POINTS SHALL BE 9/-DIRECTIONAL VANED GRATES PER C.O.R. STD DTL 204.3. SEE DETAIL SHEET CA33. 3. PIPE MA TER/AL SHALL CONFORM TO THE 2022 RSWDM CHAPTER 4, SECTION 4.2.1. AND TABLE 4.1.1.A2. 4. SEE SHEET C4.10 AND C4.11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MA Y BE CLASS 52 DUCTILE IRON IF DES/RED. O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425526 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LSULRFAICE WATER UTILITY f DEVELOPMENT ENGINEERINGAr IL ah 12/06/2023 yqi 12/06/2023 N DATE: O TOWNS ON 12TH 101111202J CITY OF 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: DRAWING NO, Planning/Building/Public Works Dept. ROAD & STORM DRAINAGE PLAN & PROFILE C4. 06 ROW 5 SHEET: OF: 26 93