Loading...
HomeMy WebLinkAboutR-425527O v EX GROUND CONTOUR (TYP) PROPERTY L/NE (TYP) EX OFFS/TE TREE TO REMAIN (TYP) PROPOSED FINISH GRADE CONTOUR (TYP) j I / 76 75 74 STA. 70*01.50, 0. 00' TYPE 1, VANED GRATE 79LF 12" DI RIM 422.05 00.0051 -� 6" 1E IN 419.36 (W) / ,�� �0 12" IF OUT 418.86 (S) �II dI I X TRACT /f ��� Eli (CR/T/CAL AREA), / 10 TOP OF SLOPE S 707L00. 00 BEGIN ROAD 15' SETBACK , 77 78. 79 U81 (TYP) ASPHAL T THICKENED EDGE CB 33 TO BE ADDED TO END OF ROW 6, STA. 70,180.12, 0.00' TO DIRECT DRAINAGE TO CB 34 TYPE 2-48" RIM 424.71 12"IEIN418.46(N) 6" IE /N 418.96 (W) 12" IE OUT 418.46 (5) 430 ' - ASPHAL T THICKENED EDGE TO BE ADDED TO END OF ROW 6, TO DIRECT DRAINAGE TO CB 34 70100 = ROW 6 EL: 422.00 BEGIN ROAD /MPROI/EMENT 420 410 / SEE SHEET C4.02 73 1 72 4)k', 71 f 72.00, ROW 6 = 17*90.67, ROAD A .-JIR 71f00 \ 97LF 12" DI-1 00.0051 81 82 83 84 85 86 STORM CLEANOUT PER C.O.R. STD DTL 226, SEE SHEET C4.33 (TYP) SEE SHEETS C4.10-C4.11 FOR STORM SERVICE LINE DESIGN (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. EX/STING GROUND 0 ROAD � (TYP) A. E I PERCC.O.R. ATCHB lD DTL SIN P200, 0 36 SEE SHEET C4.33 (TYP) STA. 72f77.19, 0.00' TYPE 1, VANED GRATE CATCH BASIN TYPE 2 RIM 425.26 PER C. O.R. STD DTL 201, 6" If /N 421.76 (W) SEE SHEET C4.33 (TYP) 12" IE OUT 421.26 (N) 70 69 1 68 67 \ I \ 100LF 12" C-900 / \ / 0 0.0329 I TRACTL (CRI17CAL AREA) 42 ,72f87.77 2f END ROAD NIA- 87� 88 89 90 ' 32 EX TREE 15' BSBL STA. 71f77.00, 0.00' TO BE SAVED TYPE 2-48'; (TYP) RIM 427.11 12 IE IN 417. 97 (N) 12" IE /N 417. 97 (5) 6" IE IN 418.47 (NW) 12" IE OUT 417.97 (E) IGH PT STA: 71 *80.15 HIGH PT EL.• 427.11 PV/ STA.- 71f72.00 PV/ EL: 427.82 100.00 VC o �o PROPOSED GRADE moo 0 ROAD � (TYP) o N MI F 12 97LF 12" D/ 0 0.0051 ^mod 0o r\ 03 .;. Q -4 .� d W �L W W f1-�Lu� W EXISTING ELEV. R0 �V V 0 ROAD � (TYP) . PROPOSED ELEV. HOR/Z. SCALE.- I" JO' 0 ROAD (TYP) l/ERT. SCA E. 1 "5' N o g rr cep h � � � � g � � • ri N a � 70+00 70+50 71 +00 71 +50 72+00 72+50 73+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/g1 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS \I�Cem FIL M J S 7/26/23 HHH SURVEYED: BY OTHERS K E L 9/ 12/23 HHH DESIGNED: ROLL/ HEAVR/N KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 430 420 410 73+50 VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M `(EY MAP SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE STORM SERVICE - - - - STORM EASEMENT _p EX/STING STORM PIPE 4 STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE - TYPE 1 0 0) STORM STRUCTURE - TYPE 2 CB STANDARD NOTES 1. ALL STORM FRAMES SHALL BE VANED GRA TES PER C. 0. R STD DTL 204.2 UNLESS OTHERWISE NOTED. SEE DETAIL SHEET C4.33. 2. STORM FRAMES WITHIN SAG CURIES AT LOW POINTS SHALL BE 81-DIRECTIONAL VANED GRATES PER C.O.R. STD DTL 204.3. SEE DETAIL SHEET CAJJ 3. PIPE MA TER/AL SHALL CONFORM TO THE 2022 RSWDM CHAPTER 4, SECT/ON 4.2.1. AND TABLE 4.1.1.A2. 4. SEE SHEET CA 10 AND C4.11 FOR STORM SERVICE PLAN. 5. PIPE MA TER/AL SHOWN AS C-900 PVC MAY BE CLASS 52 DUCTILE IRON /F DES/RED. O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425527 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LSULRFACE WATER UTILITY A 11 DEVELOPMENT ENGINEERING ah 12/06/2023 yqi 12/06/2023 N DATE: O CITY 0 F TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: RENTON PAGE: � DRAWING NO: Planning/Building/Public Works Dept. ROAD & STORM DRAINAGE PLAN & PROFILE C4. 07 RO I �/�/ A� G SHEET: OF: V 27 91