Loading...
HomeMy WebLinkAboutR-425538Lr) 4 SEE SHEET C7.02 N N NLO �0°50 rr 53 54 :.;II r / d' d' APN 3307801LE � � 55 56 57 58 59 • . I� g TRACT H / 41 (CRITICAL AREA) I I JEN / � \ Nr ' I TRACT L (CRI T/CAL AREA) % a 42 I / �/ I \ \ / 1�\W ,I ;.• 'a ' 39 ❑ I 4 ,. ( 305,9245�GG y \ �I ly \ , a pN 042opERTIEs 43 "OAApAY PR ` EXISTING TREE TO BE SA VED 44 52 51 50 49 4R Q (rYP) 46 ; rrH c, i [a ` h � \ v�l Pz SEE UTILITY CROSSING TABLE .�0 9PEN " N SHEET C7.04 (TYP) Y TRACT M 45 SPACE) e � u F IIzi b 3 i 9 •' NI+IN 5 9°46 \ 1 �� 5 � ❑ �iJ \ ApN ° pON WONO �\ / \ 28 29 30 24 25 26 27 31 32 33 34 O PROPOSED WATER (TYP) 35 36 37 9061 I PROPOSED SEWER (TYP) 6 ApN 4230ERT1C5 LLC PPOP M I PROPOSED STORM (TYP) ]NI p ALp AY TRACTA `. 7 ... STMENT N• 1 \ i (ACCESS & UMITY) a ApJO —3002 TRACT B "" , ... ,. ... ' L°T LINELLA, LN O9 O .. (ACCESS & UTILITY)' A :. : ' . RENTON LO 106, 2g000 7.CITY O NO• LINO 20°50 g2 I — ' L.L.A. REC- I 23 22 21 20 19 18 17 16 15 14 13 12 Jill 10 9 ApN 0423o5�Y�O4 pHUON I'' row 0425500 TRACT /V ApN 305— 0423ATES LLG ApN 055— 2 (OPEN SPA OALpAY & A DAMES UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 811 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH NO. REVISION BY 1 DATE 1 APPR SURVEYED: BY OTHERS DESIGNED: ROLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M c� SD SD-- o—o—o CONNECT TO EXISTING WATER CITY OF RENTON Planning/Building/Public Works Dept. `(EYMAP SCALE: 1" = 30' 0 15 30 60 STORM LEGEND STORM PIPE STORY _SD EX/S NGESTORM P/PE STORM PIPE FLOW ARROW ❑❑ STORM STRUCTURE — TYPE 1 CS STORM STRUCTURE — TYPE 2 CB SEWER LEGEND SEWER PIPE SEWER SERWCE _SS EX/STING SEWER PIPE ­4 SEWER PIPE FLOW ARROW 0 SEWER STRUCTURE SEWER CLEANOUT WA TER LEGEND r�:••wAf•r WA TER MAIN —W EXISTING WATER P/PE v HI WATER FITTING �• ~� Z z • FIRE HYDRANT ® WA TER METER 9 •� TYPE / BLOW_ OFF AIR— VAC 100NAL 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425538 S-425515 W-425515 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 w 0 0 N M N v 0 0 N N WASTEWATER UTILITY jstowell 11 /13/2023 kmj 141% TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 UTILITY CROSSING PLAN DATE: 0/111202J FIELDeo PAGE DRAWING NO: �7 C7.03 SHEET: OF: 62 93