HomeMy WebLinkAboutR-425555I O GALVANIZED UNION GALVANIZED UNION APPROVED DOUBLE CHECK VALVE PLASTIC VALVE BOX CARSON 0910 6" MIN. (SEE IRRIGATION SCHEDULE) O OR EQUAL AMETEK BOX OR 2" DIAMETER 4" MIN. `W GATE VALVE ��� P.V.C. WITH LOCKING CAP. „ PRESSURE REDUCING VALVE GALVANIZED UNION FEBCO PRV-1 INSTALL SIDEWAYS WATER SERVICE FROM MIN. IRRIGATION METER MAIN LINE TO SYSTEM. GALVANIZED UNION TEST COCKS TO FACE SIDEWAYS ALLOW QUICK COUPLING VALVE 1" WASHED GRAVEL UNDER 6" MIN. CLEARANCE BETWEEN THEM AND (SEE IRRIGATION SCHEDULE) ENTIRE ASSEMBLY 6" DEPTH, BLOCK UNIT THE SIDE OF BOX. AS REQUIRED. N N NOTES: 1. ENCLOSURE 2" & SMALLER D.C.V.A. IN TWO METER BOXES STACKED ON TOP OF EACH OTHER OR OVERSIZE BOX O MUST HAVE REMOVABLE COVER, BOXES TO BE LOCATED IN SIDEWALK AND AREAS WITH VEHICULAR TRAFFIC SHALL BE METAL EQUAL TO OLYMPIC FOUNDRY SM30 BOXES, IN OTHER NON TRAFFIC AREAS TO BE CARSON r^ INDUSTRIES 1730-18 BCFXL METER BOX WITH 1730 COVER. 2. PER PLUMBING CODE REQUIREMENT, IRRIGATION SYSTEMS MUST HAVE SHUT OFF INSTALLED AS SHOW, FEMALE FITTINGS ARE PROHIBITED IN CONJUNCTION WITH METALLIC MALE FITTINGS. 3. ALL INSTALLATIONS MUST MEET MINIMUM STANDARDS OF THE UNIFORM PLUMBING CODE AND WSDOH APPROVED INSTALLATION LIST. O 4. TESTING IS REQUIRED BY A WASHINGTON STATE DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER; ASSEMBLY TO BE MAINTAINED BY OWNER. 5. USE PIPE DOPE ON ALL GALV. FITTINGS DETAIL - POINT OF CONNECTION NOT TO SCALE Yam_. N LATERAL LIN MATIC CONTROL VALVE FROM SOURCE IRRIGATION WATER METER (CgNNECTION AND WATER METER VALVE BOX GALVANIZED PIPE TO POINT OF 2" BRASS BALL VALVE OT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY. 'E TO BE SET PLUMB & CENTERED IN VALVE BOX. TRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT. ✓IDE 6" DEPTH DRAIN ROCK. APPROVED DOUBLE CHECK VALVE (SEE DETAIL HEREON) VALVE BOX (CARSON JUMBO BOX) BRASS QUICK COUPLER VALVE (RAINBIRD 44LRC) FLOW SENSOR PVC PIPE (SCHEDULE 80) MASTER CONTROL VALVE PVC IRRIGATION MAIN (SCHEDULE 40) SPRINKLER HEAD REMOTE CONTROL VALVE NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY. 2. VALVE TO BE SET PLUMB & CENTERED IN VALVE BOX. 3. CONTRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT. 4. PROVIDE 6" DEPTH DRAIN ROCK. DETAIL - POINT OF CONNECTION PLAN (NO PR PLASTIC ISOLATION BALL VALVE SAME SIZE AS CONTROL VALVE FINI: VAULT FLUSH W/ FINISH GRADE // COMPACTED CLEAN BACKFILL 4" CLEAR PVC LATERAL PIPE USE CARSON STANDARD VALVE BOX FOR 1" PVC MAINLINE VALVES,CARSON JUMBO VALVE BOX FOR 1-1/2" R VALVES VAULTVALVES,ANDSUY O EXTEND MWV6" BELOW VALVES.VALVE. APED TOGETHERIELD USE EXTENSIONS AS NECESSARY. 10" O.C. LOCATE 6" FROM SIDE OF MAINLINE 3" MIN. SCHEDULE 40 PVC NIPPLE, TYP. CL R LENGTH AS REQUIRED COMPACTED CLEAN BACK -FILL OR BEDDING -SCHEDULE 40 PVC 90 SAND, 6" DEPTH BELOW BLULOCK & PVC CLASS 200 PIPE PVC UNIONS, TYP. USE 3" LENGTH NIPPLES BOTH SIDES OF UNION. VALVE NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE. 2. ALL PIPE AND FITTINGS WITHIN VAULT TO BE SCH 40 PVC SAME SIZE AS OUTLET LATERAL. 3. ALL BOLT COVERS TO BE LOCKING TYPE, BOLT INSTALLED. 4. NO FEMALE ADAPTERS PERMITTED. 5. TEFLON TAPE ONLY. USE NO PIPE DOPE. 6. PROVIDE 6" WASHED DRAIN ROCK BENEATH VAULT. DETAIL - ZONE CONTROL VALVE NOT TO SCALE HEAD TO HEAD SPACING MAY BE DEFINED AS EACH HEAD'S SPRAY HITTING EACH ADJACENT HEAD, ALL DIRECTIONS. FOR EXAMPLE, 12' RADIUS HEADS SHALL NOT BE SPACED FURTHER THAN 12' ALL DIRECTIONS. ri HEAD TO HEAD LAYOUT NOTE: PLAN VI m ALL SHRUB HEADS TO BE IN SHRUB BED, AND TURF HEADS SHALL BE PLACED IN THE TURF, 4" FROM EDGE OF BED. NOTES: 1. USE 4" POP -UPS IN TURF AREAS AND 12" POP -UPS IN SHRUB OR GROUND COVER AREAS. DETAIL - HEAD LAYOUT NOT TO SCALE c» N 0 N m 0 NOT TO SCALE )OT BARRIER )NCRETE SIDEWALK . IN SIDEWALK PLANTING STRIPS PLACE MAINLINE NT 24" DEPTH AND 12" IN FROM SIDEWALK. 2. IN SIDEWALK PLANTING STRIPS PLACE _ATERALS AT 12" DEPTH AND 18" IN FROM 31DEWALK. BARE COPPER TRACE WIRE 12" GAUGE TAPED ON MAINLINE 15" O.C. MAINLINE AND LATERAL TRENCHING ASPHALT, CONCRETE OR MASONRY PAVED SURFACE BY OTHERS 'COMPACTED BACKFILL FROM NATIVE SOIL 1. SLEEVES REQUIRED UNDER ALL PAVED AREAS. 2. DUCT TAPE ENDS OF SLEEVE PIPE 3. SURVEYOR TO LOCATE ALL HARD SURFACES PRIOR ° TO SLEEVE PIPE INSTALLATION. 5/8 MINUS CRUSHED ROCK BEDDING PVC SLEEVE SLEEVE TRENCHING DETAIL - TRENCHING NOT TO SCALE 10 EAVE OF BUILDING O HUNTER WRF-CLIK WIRELESS RAIN/FREEZE SENSOR O PLASTIC TIE DOWN STRAP ®MOUNTING BRACKET DETAIL - RAIN SENSOR (ROOF MOUNT) NOT TO SCALE 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS N0. REVISION PLUG-IN TRANSFORMER SPRAY OR BUBBLER NOZZLE -LUSH W/ FINISH GRADE VOZZLE & BODY PER SPECIFICATIONS JSE BOTTOM INLET ONLY SCH 40 PVC STREET ELL AND SWING PIPE 90 POLY PIPE 30" MAX. LENGTH SCH 40 PVC STREET ELL AND SWING PIPE 90 SCH 40 PVC FITTINGS, TYP. LATERAL, TYP. SIZE AS INDICATED ON PLAN SPRAY HEAD SECTION VIEW NOTES: 1. USE 4" POP -UPS IN TURF AREAS AND 6" POP -UPS IN SHRUB OR GROUND COVER AREAS, AS SHOWN IN IRRIGATION SCHEDULE. 2. USE TEFLON TAPE AT ALL TREADED FITTINGS DETAIL - POP-UP SPRAY HEAD NOT TO SCALE INTERIOR WALL MODEL X-CORE-XOOi CONTROL WIRE IN ELECTRICAL CONDUIT. SIZE AND TYPE PER LOCAL CODE DETAIL - CONTROLLER WALL MOUNT NOT TO SCALE MJS 7/26/23 HHH SURVEYED: BY OTHERS KEL 9/12/23 HHH DESIGNED: LINDSEY 50LOF/0 KEL o/11/2 HHH DRAWN: DANNY VILLAGRANA CHECKED: LINOSEY SOLORIO BY DATE APPR APPRGVELINOSEY SOLORIO SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: HAD 1983/1991 DATUM REMOTE CONTROL VALVE WITH FILTER AND PRV LINE FLUSHING VALVE AREA PERIMETER LATERAL TUBING START CONNECTION ADAPTER EXHAUST HEADER TEE SUPPLY HEADER DETAIL - DRIP LINE LAYOUT NOT TO SCALE 18" MIN. 24" MAX. b 30" MIN. 15" MIN. PVC SCH 80 50" MIN. UNINTERRUPTED FLOW NOTES: 1. DO NOT ALLOW VAULT TO REST ON PIPE 2. PROVIDE MIN. 6" DEPTH DRAIN ROCK. 3. USE PE-89 WIRE FOR CONNECTION TO FLOW MONITOR. C TY OF RENTON f;R Planning/Building/Public Works Dept. DETAIL - FLOW SENSOR NOT TO SCALE STANDARD VAULT PER SPECIFICATIONS TEE WITH 1" FLOW SENSOR, SEE SPECS. BUSHING, TYPICAL TO MASTER VALVE MAIN LINE MAIN LINE SECTION CIVIL ENGINEERING �SNIN�TCORE LANDSCAPE ARCHITECTURE 7� 0,'�1 PLANNING �zw� DESIGN SURVEYING a v 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 R-425555 AP�P IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING AMorganroth [11/16/23] ' DEVELOPMENT ENGINEERING yqi 12/06/2023 ' TOWNS ON 12TH 3916 & 3926 NE 12TH ST, RENTON, WA 98056 A TION DETAILS O 0 0 N N N DATE: O 0/111202J FIELDDO t„ PAGE: DRAWING NO: .3 SHEET: OF: 79 99