O GALVANIZED UNION GALVANIZED UNION
APPROVED DOUBLE CHECK VALVE
PLASTIC VALVE BOX CARSON 0910 6" MIN. (SEE IRRIGATION SCHEDULE)
O OR EQUAL AMETEK BOX OR 2" DIAMETER
4" MIN.
`W GATE VALVE ��� P.V.C. WITH LOCKING CAP.
„ PRESSURE REDUCING VALVE GALVANIZED UNION
FEBCO PRV-1 INSTALL SIDEWAYS
WATER SERVICE FROM MIN.
IRRIGATION METER MAIN LINE
TO SYSTEM.
GALVANIZED UNION
TEST COCKS TO FACE SIDEWAYS ALLOW QUICK COUPLING VALVE 1" WASHED GRAVEL UNDER
6" MIN. CLEARANCE BETWEEN THEM AND (SEE IRRIGATION SCHEDULE) ENTIRE ASSEMBLY 6" DEPTH, BLOCK UNIT
THE SIDE OF BOX. AS REQUIRED.
N
N NOTES:
1. ENCLOSURE 2" & SMALLER D.C.V.A. IN TWO METER BOXES STACKED ON TOP OF EACH OTHER OR OVERSIZE BOX
O MUST HAVE REMOVABLE COVER, BOXES TO BE LOCATED IN SIDEWALK AND AREAS WITH VEHICULAR TRAFFIC
SHALL BE METAL EQUAL TO OLYMPIC FOUNDRY SM30 BOXES, IN OTHER NON TRAFFIC AREAS TO BE CARSON
r^ INDUSTRIES 1730-18 BCFXL METER BOX WITH 1730 COVER.
2. PER PLUMBING CODE REQUIREMENT, IRRIGATION SYSTEMS MUST HAVE SHUT OFF INSTALLED AS SHOW, FEMALE
FITTINGS ARE PROHIBITED IN CONJUNCTION WITH METALLIC MALE FITTINGS.
3. ALL INSTALLATIONS MUST MEET MINIMUM STANDARDS OF THE UNIFORM PLUMBING CODE AND WSDOH
APPROVED INSTALLATION LIST.
O 4. TESTING IS REQUIRED BY A WASHINGTON STATE DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY
TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER; ASSEMBLY TO BE MAINTAINED BY OWNER.
5. USE PIPE DOPE ON ALL GALV. FITTINGS
DETAIL - POINT OF CONNECTION
NOT TO SCALE
Yam_.
N
LATERAL LIN
MATIC CONTROL VALVE
FROM SOURCE
IRRIGATION WATER METER (CgNNECTION AND WATER METER
VALVE BOX
GALVANIZED PIPE TO POINT OF
2" BRASS BALL VALVE
OT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY.
'E TO BE SET PLUMB & CENTERED IN VALVE BOX.
TRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT.
✓IDE 6" DEPTH DRAIN ROCK.
APPROVED DOUBLE CHECK VALVE (SEE DETAIL HEREON)
VALVE BOX (CARSON JUMBO BOX)
BRASS QUICK COUPLER VALVE (RAINBIRD 44LRC)
FLOW SENSOR
PVC PIPE (SCHEDULE 80)
MASTER CONTROL VALVE
PVC IRRIGATION MAIN (SCHEDULE 40)
SPRINKLER HEAD
REMOTE CONTROL VALVE
NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE USE EXTENSIONS AS NECESSARY.
2. VALVE TO BE SET PLUMB & CENTERED IN VALVE BOX.
3. CONTRACTOR TO PROVIDE (1) EACH QCV KEY AND SWIVEL HOSE ELL PER PROJECT.
4. PROVIDE 6" DEPTH DRAIN ROCK.
DETAIL - POINT OF CONNECTION PLAN (NO PR
PLASTIC ISOLATION BALL VALVE
SAME SIZE AS CONTROL VALVE
FINI:
VAULT FLUSH W/ FINISH GRADE
//
COMPACTED
CLEAN BACKFILL
4" CLEAR
PVC LATERAL PIPE
USE CARSON STANDARD VALVE BOX FOR 1"
PVC MAINLINE
VALVES,CARSON JUMBO VALVE BOX FOR 1-1/2"
R
VALVES VAULTVALVES,ANDSUY O EXTEND MWV6" BELOW
VALVES.VALVE.
APED TOGETHERIELD
USE EXTENSIONS AS NECESSARY.
10" O.C. LOCATE 6"
FROM SIDE OF MAINLINE
3" MIN.
SCHEDULE 40 PVC NIPPLE, TYP.
CL R
LENGTH AS REQUIRED
COMPACTED CLEAN
BACK -FILL OR BEDDING
-SCHEDULE 40 PVC 90
SAND, 6" DEPTH BELOW
BLULOCK & PVC CLASS 200
PIPE
PVC UNIONS, TYP.
USE 3" LENGTH NIPPLES BOTH SIDES OF UNION.
VALVE NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE.
2. ALL PIPE AND FITTINGS WITHIN VAULT TO BE SCH 40 PVC SAME SIZE AS OUTLET LATERAL.
3. ALL BOLT COVERS TO BE LOCKING TYPE, BOLT INSTALLED.
4. NO FEMALE ADAPTERS PERMITTED.
5. TEFLON TAPE ONLY. USE NO PIPE DOPE.
6. PROVIDE 6" WASHED DRAIN ROCK BENEATH VAULT.
DETAIL - ZONE CONTROL VALVE
NOT TO SCALE
HEAD TO HEAD SPACING MAY BE DEFINED AS EACH HEAD'S SPRAY HITTING EACH
ADJACENT HEAD, ALL DIRECTIONS. FOR EXAMPLE, 12' RADIUS HEADS SHALL NOT BE
SPACED FURTHER THAN 12' ALL DIRECTIONS.
ri
HEAD TO HEAD LAYOUT NOTE: PLAN VI
m
ALL SHRUB HEADS TO BE IN SHRUB BED, AND TURF HEADS SHALL BE PLACED IN THE
TURF, 4" FROM EDGE OF BED.
NOTES:
1. USE 4" POP -UPS IN TURF AREAS AND 12" POP -UPS IN SHRUB OR GROUND COVER
AREAS.
DETAIL - HEAD LAYOUT
NOT TO SCALE
c»
N
0
N
m
0
NOT TO SCALE
)OT BARRIER
)NCRETE SIDEWALK
. IN SIDEWALK PLANTING STRIPS PLACE MAINLINE
NT 24" DEPTH AND 12" IN FROM SIDEWALK.
2. IN SIDEWALK PLANTING STRIPS PLACE
_ATERALS AT 12" DEPTH AND 18" IN FROM
31DEWALK.
BARE COPPER TRACE WIRE 12" GAUGE TAPED
ON MAINLINE 15" O.C.
MAINLINE AND LATERAL TRENCHING
ASPHALT, CONCRETE OR MASONRY PAVED SURFACE BY OTHERS
'COMPACTED BACKFILL FROM NATIVE SOIL
1. SLEEVES REQUIRED UNDER ALL PAVED AREAS.
2. DUCT TAPE ENDS OF SLEEVE PIPE
3. SURVEYOR TO LOCATE ALL HARD SURFACES PRIOR
° TO SLEEVE PIPE INSTALLATION.
5/8 MINUS CRUSHED ROCK BEDDING
PVC SLEEVE
SLEEVE TRENCHING
DETAIL - TRENCHING
NOT TO SCALE
10 EAVE OF BUILDING
O HUNTER WRF-CLIK WIRELESS RAIN/FREEZE SENSOR
O PLASTIC TIE DOWN STRAP
®MOUNTING BRACKET
DETAIL - RAIN SENSOR (ROOF MOUNT)
NOT TO SCALE
1
REVISED
PER
CITY
COMMENTS
2
REVISED
PER
CITY
COMMENTS
3
REVISED
PER
CITY
COMMENTS
N0.
REVISION
PLUG-IN TRANSFORMER
SPRAY OR BUBBLER NOZZLE
-LUSH W/ FINISH GRADE
VOZZLE & BODY PER SPECIFICATIONS
JSE BOTTOM INLET ONLY
SCH 40 PVC STREET ELL AND SWING PIPE 90
POLY PIPE
30" MAX. LENGTH
SCH 40 PVC STREET ELL AND SWING PIPE 90
SCH 40 PVC FITTINGS, TYP.
LATERAL, TYP.
SIZE AS INDICATED ON PLAN
SPRAY HEAD SECTION VIEW
NOTES:
1. USE 4" POP -UPS IN TURF AREAS AND 6" POP -UPS IN
SHRUB OR GROUND COVER AREAS, AS SHOWN IN
IRRIGATION SCHEDULE.
2. USE TEFLON TAPE AT ALL TREADED FITTINGS
DETAIL - POP-UP SPRAY HEAD
NOT TO SCALE
INTERIOR WALL
MODEL X-CORE-XOOi
CONTROL WIRE IN ELECTRICAL
CONDUIT. SIZE AND TYPE
PER LOCAL CODE
DETAIL - CONTROLLER WALL MOUNT
NOT TO SCALE
MJS
7/26/23
HHH
SURVEYED:
BY OTHERS
KEL
9/12/23
HHH
DESIGNED:
LINDSEY 50LOF/0
KEL
o/11/2
HHH
DRAWN:
DANNY VILLAGRANA
CHECKED:
LINOSEY SOLORIO
BY
DATE
APPR
APPRGVELINOSEY SOLORIO
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: HAD 1983/1991
DATUM
REMOTE
CONTROL
VALVE WITH
FILTER AND
PRV
LINE FLUSHING VALVE
AREA PERIMETER
LATERAL TUBING
START CONNECTION ADAPTER
EXHAUST HEADER
TEE
SUPPLY HEADER
DETAIL - DRIP LINE LAYOUT
NOT TO SCALE
18" MIN.
24" MAX.
b
30" MIN. 15" MIN.
PVC SCH 80
50" MIN. UNINTERRUPTED FLOW
NOTES:
1. DO NOT ALLOW VAULT TO REST ON PIPE
2. PROVIDE MIN. 6" DEPTH DRAIN ROCK.
3. USE PE-89 WIRE FOR CONNECTION TO FLOW MONITOR.
C TY OF
RENTON
f;R
Planning/Building/Public Works Dept.
DETAIL - FLOW SENSOR
NOT TO SCALE
STANDARD VAULT PER SPECIFICATIONS
TEE WITH 1" FLOW SENSOR,
SEE SPECS.
BUSHING, TYPICAL
TO MASTER VALVE
MAIN LINE
MAIN LINE SECTION
CIVIL ENGINEERING
�SNIN�TCORE LANDSCAPE ARCHITECTURE
7� 0,'�1 PLANNING
�zw�
DESIGN SURVEYING
a v 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
R-425555
AP�P
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
AMorganroth [11/16/23] '
DEVELOPMENT ENGINEERING
yqi 12/06/2023 '
TOWNS ON 12TH
3916 & 3926 NE 12TH ST, RENTON, WA 98056
A TION DETAILS
O
0
0
N
N
N
DATE:
O
0/111202J
FIELDDO t„
PAGE:
DRAWING NO:
.3
SHEET: OF:
79 99