AMENDMENT NO. 4 TO AGREEMENT CAG-20-031 FOR THE
RAINIER AVE. AND OAKESDALE AVE. STORMWATER PUMP
STATION UPGRADES PROJECT
THIS AMENDMENT, dated for reference purposes only as April 1, 2024, is by and between the
City of Renton (the "City"), a Washington municipal corporation, and RH2 Engineering, Inc.
("Consultant"), a Washington corporation. The City and the Consultant are referred to collectively
in this Amendment as the "Parties." Once fully executed by the Parties, this Amendment is
effective as of the last date signed by both parties.
Whereas, the City engaged the services of the Consultant under Agreement CAG-20-031, dated
January 24, 2020, to provide necessary services for the Rainier Ave. and Oakesdale Ave.
Stormwater Pump Station Upgrades Project -Alternatives and Feasibility Evaluation (referred to
herein as the "Agreement");
Whereas, the Parties wish to amend the Agreement to add additional scope of work, and to
change the time for performance, and to add additional compensation, in order to deliver final
design for the Rainier Ave S Pump Station backup generator.
NOW THEREFORE, it is mutually agreed upon that CAG-20-031 is amended as follows:
1.Scope of Work: Section 1, Scope of Work, is amended to include additional technical
evaluation, private entity consultation, and design and drafting services, as specified in
Exhibit A-4, which is attached and incorporated herein.
2.Time of Performance: Section 3, Time of Performance, is amended pursuant to the
schedule(s) set forth in Exhibit C-4. All Work shall be performed by no later than July 31,
2026.
3.Compensation: Section 4, Compensation, is amended so that the maximum amount of
compensation payable to Consultant is increased by $92,350 from $160,300 to $252,650,
plus any applicable state and local sales taxes. The additional compensation shall be paid
based upon Work actually performed according to the rate(s) or amounts specified in
Exhibit B-4, which is attached and incorporated herein.
CAG-20-031, Adden #4-24
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
4.All terms of the Agreement not explicitly modified herein shall remain in full force and
effect and such terms shall apply to Work performed according to this Amendment as if
fully set forth herein.
IN WITNESS WHEREOF, the Parties have voluntarily entered into this Amendment as of the date
last signed by the Parties below.
CITY OF RENTON
By: __________ _
Armando Pavone
Mayor
Date
Attest
Jason A. Seth
City Clerk
Approved as to Legal Form
By: ------------
Chery I Beyer
Assistant Renton City Attorney
Contract Template Updated 06/17/2021
PAGE 2 OF 2
CONSULTANT
By:�L/;2�
Rick Ballard
Corporate Secretary, RH2 Engineering, Inc.
04/04/2024
Date
4/17/2024
Approved by Cheryl Beyer, via email 4/3/2024
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
EXHIBIT A-4
Scope of Work
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Alternatives and Feasibility Evaluation
Amendment No. 4 to CAG-20-031
Rainier SWPS Final Design and Services During Bidding
April 2024
Background
The City of Renton (City) retained RH2 Engineering, Inc., (RH2) to perform an alternatives evaluation
of its Rainier and Oakesdale Stormwater Pump Stations (SWPS). The Rainier SWPS was constructed
in the 1960s. Its electrical equipment is from the original construction and does not meet the current
electrical code with regards to the location in a Class 1, Division 2 area. To meet current electrical
code, new electrical equipment will need to be relocated to a separate electrical building or under a
shelter outside of the classified area. In addition to electrical equipment upgrades, the City requested
RH2 evaluate alternatives for equipping the station with a permanent emergency generator.
Based on the alternatives evaluation and preliminary design prepared by RH2, the City has chosen to
locate the emergency generator for the Rainier SWPS within the Rainier Avenue right-of-way (ROW),
just south of the existing pump station. Improvements also will include upgrades to the existing
electrical system. This Scope of Work includes the preparation of bid-ready design plans,
specifications, and opinion of probable construction cost (OPCC), as well as services during bidding,
for the Rainier SWPS.
This Scope of Work presumes that the previously developed 60-percent design will be advanced to
bid-ready design. This design is contingent upon the City working with Puget Sound Energy to extend
a gas main along Rainer Avenue SW to serve the service line to the backup generator.
Task 6 -Project Management
Objective: Manage the RH2 project team and maintain files and records. Monitor the project scope,
budget, and schedule.
Approach:
6.1 Provide monthly invoices documenting work performed and budget status.
6.2 Maintain frequent communication with the City to discuss the project's progress.
6.3 Maintain project files and records.
RH2 Deliverables:
•Monthly invoices in electronic PDF.
1
3/20/2024 7:46:32 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 4\AMND_NO. 4_EXH A-4_SOW_OAKESDALE RAINIER SWPS_RAINIER DESIGN AND SDB_REV-1.DOCX
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Rainier SWPS Final Design and Services During Bidding
Task 7 -75-Percent Plans, Specifications, and OPCC
Exhibit A-4
Scope of Work
Amendment No. 4
Objective: Advance the 60-percent emergency generator and electrical building design plans
previously prepared by RH2 to 75-percent design plans. Prepare 75-percent technical specifications
and OPCC. Submit 75-percent design documents to the City for review.
Approach:
7.1 Advance the preliminary design plans to 75 percent.
7.2 Prepare 75-percent technical specifications based on RH2's technical specifications that are
tailored for this project.
7.3 Develop a 75-percent OPCC for this project.
7.4 Submit the 75-percent design plans, specifications, and OPCC to the City for review. Attend
one (1) virtual review meeting with City staff.
Assumptions:
•RH2 will rely upon the accuracy and completeness of information, data, and materials
generated or produced by the City or others in relation to this Scope of Work.
•It is assumed the City will submit the ROW permit for this project.
•It is assumed the City will prepare the non-technical specifications.
Provided by City:
•Review and comment on 75-percent plans, technical specifications, and OPCC.
•Attendance at 75-percent design review meeting.
RH2 Deliverables:
•75-percent review plans, technical specifications, and OPCC in electronic PDF.
•Attendance at virtual 75-percent design review meeting.
Task 8 -90-Percent Plans, Specifications, and OPCC
Objective: Prepare 90-percent design plans, general and technical specifications, and OPCC. Perform
internal quality assurance and quality control (QA/QC) review and submit 90-percent design
documents to City for review.
Approach:
8.1 Advance design plans from 75 percent to 90 percent, including incorporating review
comments from the City into the design plans and providing additional details for the
90-percent design plans.
2
3/20/2024 7:46:32 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 4\AMND_NO. 4_EXH A-4_SOW_OAKESDALE RAINIER SWPS_RAINIER DESIGN AND SDB_REV-1.DOCX
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Rainier SWPS Final Design and Services During Bidding
Task 10 -Services During Bidding and Award
Exhibit A-4
Scope of Work
Amendment No. 4
Objective: Provide engineering services during the bidding phase of the Rainier SWPS project.
Approach:
10.1 Prepare bid advertisement and coordinate the timing and placement with the City. The City
will submit the advertisement to the appropriate publications and pay any applicable fees.
10.2 Produce PDF and hard copy sets as listed in the deliverables of the plans for RH2 and City use.
The City will produce hard copies of the bid-ready specifications for bidding the project.
10.3 Respond to questions from bidders. Revise the plans, technical specifications, or construction
contract conditions during the bidding process, as warranted. If requested, prepare addenda.
10.4 Assist the City with the evaluation of the qualifications and references for the apparent low
bidder. Prepare recommendation of bid award letter. It is assumed that the City will perform
the bid award and construction contract execution tasks and that RH2 will not be involved
with the bid opening activities.
10.5 Prepare construction plan sets, specifications, and construction contract documents for the
pre-construction meeting. Coordinate with the City to produce hard copies listed in the
deliverables, along with a PDF version of the documents.
Provided by City:
•Bid-ready specifications. One (1) electronic PDF and four (4) hard copies: one (1) set for City
use and bidding purposes; and three (3) sets for RH2's file and staff use during bidding.
•Management of and payment for the Builders Exchange of Washington online bidding
process.
•Distribution of bid documents and maintenance of the plan holder's list.
•Issuance of addenda, if any, to all plan holders.
•Bid opening attendance and tabulation of bids received.
•Bid award and construction contract execution.
•Construction specifications. One (1) electronic PDF and seven (7) hard copies: four (4) for
contractor; two (2) for City; and one (1) for RH2 file and staff use.
RH2 Deliverables:
•Bid-ready plan sets. One (1) electronic PDF and four (4) 11-inch by 17-inch hard copies: one
(1)set for City use and bidding purposes; and three (3) sets for RH2's file and staff use during
bidding.
•Phone assistance to vendors and bidders during the bidding phase.
•Addenda in electronic PDF, if requested. Up to two {2} are assumed.
4
3/20/2024 7:46:32 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 4\AMND_NO. 4_EXH A-4_SOW_OAKESDALE RAINIER SWPS_RAINIER DESIGN AND SDB_REV-1.DOCX
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Rainier SWPS Final Design and Services During Bidding
•Reference check of lowest bidder.
•One (1) electronic PDF of recommendation of bid award letter.
Exhibit A-4
Scope of Work
Amendment No. 4
•Construction plans sets. One (1) electronic PDF, four (4) full-size plan sets, and seven (7)
half-size plan sets: two (2) full-size and four (4) half-size sets for contractor; two (2) full-size
and two (2) half-size sets for City; and one (1) half-size set for RH2 file and staff use.
Fee for Services
RH2 estimates this additional work to be $92,350 as shown in Exhibit B-4.
Schedule
The completion for each Task is outlined in Exhibit C-4 for this Scope of Work.
5
3/20/2024 7:46:32 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 4\AMND_NO. 4_EXH A-4_SOW_OAKESDALE RAINIER SWPS_RAINIER DESIGN AND SDB_REV-1.DOCX
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
Exhibit B-4
Consultant Fee Determination -Summary Sheet
(Negotiated Hourly Rates of Pay)
Fee Schedule
Subconsultant:
RH2 ENGINEERING, INC
Negotiated Overhead Fee Multiplier Negotiated Rate
Staff Classification Hourly Rate Multiplier Per Hour
211.77% 12.00%
Professional I $ 48.40 $ 102.49 $ 18.11 $ 169.00
Professional II $ 53.55 $ 113.41 $ 20.04 $ 187.00
Professional Ill $ 59.57 $ 126.15 $ 22.29 $ 208.00
Professional IV $ 65.30 $ 138.28 $ 24.43 $ 228.00
Professional V $ 70.16 $ 148.59 $ 26.25 $ 245.00
Professional VI $ 74.17 $ 157.08 $ 27.75 $ 259.00
Professional VII $ 79.61 $ 168.60 $ 29.79 $ 278.00
Professional VIII $ 83.62 $ 177.09 $ 31.29 $ 292.00
Professional IX $ 83.62 $ 177.09 $ 31.29 $ 292.00
Technician I $ 37.80 $ 80.05 $ 14.14 $ 132.00
Technician II $ 41.24 $ 87.33 $ 15.43 $ 144.00
Technician Ill $ 46.39 $ 98.25 $ 17.36 $ 162.00
Technician IV $ 50.69 $ 107.35 $ 18.96 $ 177.00
Technician V $ 55.27 $ 117.05 $ 20.68 $ 193.00
Technician VI $ 61.00 $ 129.18 $ 22.82 $ 213.00
Technician VII $ 66.15 $ 140.10 $ 24.75 $ 231.00
Technician VIII $ 69.59 $ 147.37 $ 26.04 $ 243.00
Administrative I $ 25.20 $ 53.37 $ 9.43 $ 88.00
Administrative II $ 29.50 $ 62.47 $ 11.04 $ 103.00
Administrative Ill $ 35.23 $ 74.60 $ 13.18 $ 123.00
Administrative IV $ 41.24 $ 87.33 $ 15.43 $ 144.00
Administrative V $ 47.54 $ 100.67 $ 17.79 $ 166.00
In-House Copies B/W -8.5xll $ 0.09
In-House Copies B/W-8.5x14 $ 0.14
In-House Copies B/W-llx17 $ 0.20
In-House Copies Color -8.5xll $ 0.90
In-House Copies Color -8.5x14 $ 1.20
In-House Copies Color -llxl 7 $ 2.00
CAD Plots Large $ 25.00
CAD Plots Full $ 10.00
CAD Plots Half $ 2.50
CAD/GIS System Per Hour $ 27.50
Mileage Current IRS Rate
Subconsultants will be billed at cost plus 15%
Outside Services At Cost
Outside direct costs for permit fees, reports, maps, data, reprographics, couriers, postage, and non
mileage related travel expenses that are necessary for the execution of the project and are not
specifically identified elsewhere in the contract will be billed at cost.
Rates listed are adjusted annually.
DocuSign Envelope ID: 48B34DE7-2681-4C75-9E6A-8841 A0358957
EXHIBIT 8-4
Fee Estimate
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Alternatives and Feasibility Evaluation
Amendment No. 4 to CAG-20-031
Rainier SWPS Final Design and Services During Bidding
Mar-24
!Task 6
!Task 7
!Task 8
!Task 9
!Task 10
Description
Project Management
60-Percent Plans, Specifications, and OPCC
90-Percent Plans, Specifications, and OPCC
Bid-Ready Design
Services During Bidding and Award
PROJECT TOTAL
Total
Hours Total Labor
16 $ 3,728
154 $ 33,658
136 $ 30,482
48 $ 10,398
34 $ 7,522
388 $ 85,788
J:\Data\REN\119-215\00 Contract\Amend No. 4\Amnd_No. 4_EXH B-4_FEE_Oakesdale Rainier SWPS_Rainier Design and SDB_rev-1.xlsm
Total
Subconsultant Total Expense Total Cost
$ $ $ 3,728
$ $ 2,145 $ 35,803
$ $ 1,885 $ 32,367
$ $ 660 $ 11,058
$ $ 1,872 $ 9,394
$-$6,562 $ 92,350
3120/2024 7:42 AM