Loading...
HomeMy WebLinkAbout04249 Renton WA.Rpt.0003ARev1.2024-03-29.Concrete Compressive Strength Test.GREENReport Number: Service Date: Report Date: Task: Client Renton, WA 98055 375 Rainier Ave S Chick-fil-A #04249 Renton, WA (T)Chick-fil-A Inc Attn: Kari Teresa 5200 Buffington Road Atlanta, GA 30097-3508 425-742-9360 Lynnwood, WA 98036-6365 20225 Cedar Valley Rd Ste 110 Laboratory Services M7241122.0003A 03/29/24 04/27/24 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project - M7241122 Permit No.: C23000412 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: C4000A Corliss Resources Material Information 0700 137 Plant: Ticket No.: 1 10028659 Field Test Data Test Air Content (%): Result Specification 4 1/2 4 - 6 5.5 4.5 - 7.5 62 Max 95 44 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:03/29/24 0800 Edward Smith Clear 15 8 0 0 Curb at the west side of the parking area and at the south side of the north drive lane. Sample Location: Placement Method:Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Curb at the west side of the parking area and the south side of the north drive lane. Also placed the north drive entry approach slab along Rainier Ave. Placement Location: Sample Description:4-inch diameter cylinders Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Max Strength Comp Frac No.ID Spec Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested ByCond. Cyl. 1 1 3.99 12.5 04/01/24 04/05/24 7 43,310 2 APIGood 3,460 1 2 3.99 12.5 04/01/24 04/26/24 28 59,590 3 APIGood 4,770 1 3 3.99 12.5 04/01/24 04/26/24 28 58,610 2 APIGood 4,690 1 4 3.98 12.44 04/01/24 04/26/24 28 59,080 3 APIGood 4,750 Average (28 days) 4,730 Initial Cure:Final Cure:Covered with Blanket Moist Room Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Special Inspections / Materials TestingServices: Reported To: Contractor: Report Distribution: See attached distribution list.Aaron Vanderpol Group Manager ESI Jim Hibbard with ESI Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Edward Smith The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 3-31-22, Rev.7 Report Date: Service Date: Report Number: Task: M7241122.0003A 03/29/24 04/27/24 20225 Cedar Valley Rd Ste 110 Lynnwood, WA 98036-6365 425-742-9360Laboratory Services Revision 1 - 28-day results Distribution List Distribution Page (1) Chick-fil-A Inc, Kari Teresa (1) Barghausen Consulting Engineers, Inc., Alex Bell (1) City of Renton WA, Development Engineering (1) City of Renton WA, Patrick Decaro (1) City of Renton WA, Yong Qi (1) ESI Construction Inc, Eric Quevedo (1) ESI Construction Inc, Jim Hibbard (1) Jones Lang Lasalle, Agustin Solaberrieta (1) Jones Lang Lasalle, Maggie Nuckols (1) Mayes Testing Engineers, Inc, Belinda Rix (1) Mayes Testing Engineers, Inc, Myndi Kraft