Loading...
HomeMy WebLinkAbout20240425 Memo (Grady Way Stm) 2200335.10 Page 1 of 1 TO: Huy Huynh City of Renton Department of Engineering Division DATE: April 25, 2024 FROM: Yi Yang, PE Seattle - (206) 267-2425 PROJECT NO.: AHBL #2200335.10 PROJECT NAME: Watershed Affordable Housing Apartments SUBJECT: South Grady Way Existing Storm Line Upgrade In accordance with the directive from the City of Renton, the project proposes to upgrade the exiting storm pipes on the southeast side of South Grady Way, from CB 135355 to CB 136908 (City of Renton GIS Facility ID Number). The existing storm lines are 8” concrete pipes that connect to an 18” concrete pipe. The project will replace the existing pipes with 12” ductile iron pipes. The new pipe will match the crown of existing pipe. Curb and gutter will be reinstalled, and pavement will be restored for the utility trench. The Project Engineer has conducted a conveyance analysis for the existing and proposed storm pipes. The existing pipe has a capacity of discharging 1.19 cubic feet per second when it’s 90% full. The new pipe will be able to discharge 3.79 cubic feet per second when it’s 90% full. See attached documents for a FlowMaster Report. It is determined the new pipes have adequate capacity and will not create any new problems to the downstream drainage system. YY c: Taylor Galbraith, Sierra Construction Company, Inc. Attachment C:\Users\yyang\Desktop\20240425 Memo (Grady Way Stm) 2200335.10.docx Ex. 8" Conc. Project Description Manning FormulaFriction Method DischargeSolve For Input Data 0.013Roughness Coefficient ft/ft0.009Channel Slope in7.2Normal Depth in8.0Diameter Results cfs1.19Discharge ft²0.3Flow Area ft1.7Wetted Perimeter in2.4Hydraulic Radius ft0.40Top Width in6.2Critical Depth %90.0Percent Full ft/ft0.011Critical Slope ft/s3.59Velocity ft0.20Velocity Head ft0.80Specific Energy 0.696Froude Number cfs1.20Maximum Discharge cfs1.11Discharge Full ft/ft0.010Slope Full SubcriticalFlow Type GVF Input Data in0.0Downstream Depth ft0.0Length 0Number Of Steps GVF Output Data in0.0Upstream Depth N/AProfile Description ft0.00Profile Headloss %0.0Average End Depth Over Rise %41.6Normal Depth Over Rise ft/sInfinityDownstream Velocity ft/sInfinityUpstream Velocity in7.2Normal Depth in6.2Critical Depth ft/ft0.009Channel Slope ft/ft0.011Critical Slope Page 1 of 227 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 4/24/2024 FlowMaster [10.03.00.03] Bentley Systems, Inc. Haestad Methods Solution CenterROW Conveyance.fm8 New 12" DI Project Description Manning FormulaFriction Method DischargeSolve For Input Data 0.012Roughness Coefficient ft/ft0.009Channel Slope in10.8Normal Depth in12.0Diameter Results cfs3.79Discharge ft²0.7Flow Area ft2.5Wetted Perimeter in3.6Hydraulic Radius ft0.60Top Width in9.9Critical Depth %90.0Percent Full ft/ft0.009Critical Slope ft/s5.09Velocity ft0.40Velocity Head ft1.30Specific Energy 0.806Froude Number cfs3.83Maximum Discharge cfs3.56Discharge Full ft/ft0.010Slope Full SubcriticalFlow Type GVF Input Data in0.0Downstream Depth ft0.0Length 0Number Of Steps GVF Output Data in0.0Upstream Depth N/AProfile Description ft0.00Profile Headloss %0.0Average End Depth Over Rise %60.0Normal Depth Over Rise ft/sInfinityDownstream Velocity ft/sInfinityUpstream Velocity in10.8Normal Depth in9.9Critical Depth ft/ft0.009Channel Slope ft/ft0.009Critical Slope Page 2 of 227 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 4/24/2024 FlowMaster [10.03.00.03] Bentley Systems, Inc. Haestad Methods Solution CenterROW Conveyance.fm8