HomeMy WebLinkAboutWWP272955(11) LETTER OF TRANSMITTAL Date: June 3, 2002 To: Scott Clemons 9600 M.L. King Way S. Seattle,WA 98118 From: John Hobson,Project Manager City of Renton Wastewater utility 1055 So. Grady Way Renton,WA 98055 SUBJECT: East Kennydale Sanitary Infill PH 1 & Water Main replacement CONTRACT CAG-02-34 SUBMITTALS AS NOTED BELOW COPIES DATE DESCRIPTION Manufacturer STATUS Bid Item 1 6-4-02 8"&6"PVC Sewer Pie PW Pie NET 9& 11 1 6-4-02 8"&6"C900 Sewer Pie PW Pipe NET 10& 12 1 64-02 48"Sewer Manhole Hanson NET 13 1 6-4-02 54"Sewer Manhole Hanson NET 14 1 6-4-02 Select hn ort Backfill Various Pits NET 30 1 5-31-02 Resilient Wedge Valve Mueller NET 18 A-2360 1 5-31-02 Permanent B.O. Assembly Ku ferle NET 23 1 5-31-02 1"Air-vac Assembly Crispin C Series NET 16 1 5-31-02 Steel tapping sleeve FTS420 Romac Industries NET 16 1 5-31-02 Romac Style 501 Coupling Romac NET 16 1 5-31-02 Poly Wrap Northtown Co. NET 16 1 5-31-02 Compression fittings Mueller Co. NET 20,21 H-15403 H-15428 1 5-31-02 Copper Meter Setter Mueller Co. NET 20,21 B2470-2060715 1 5-31-02 Corp. Stop Mueller Co. NET 20,21 H-15008 1 5-31-02 Super Centurion Fire Mueller Co. NET 19 Hd rant,A-423 1 5-31-02 DI C153 MJ Fittings Tyler NET 16 1 5-31-02 C110 Flanged Fittings Tyler NET 16 1 5-31-02 Tyton joint Ductile Iron US Pipe NET 16 Pipe(6"& 8") 1 5-31-02 Meter Box Brooks Products,Inc. NET 20,21,23 38 Series,65 Series Status Code: Remarks: NET No exceptions taken 1. Missing submittal for poly pig (ethefoam bullet) Girrard or equal RAR Revise and Resubmit(see remarks) 2. Valve Box HDFCO Seattle Type 940B, orequal. R Rejected(see remarks) 3. 3/4"Copper Service pipe, Type K AWC Approved wit omments (see remarks) a—�//. &-/ A�Z Signed Date material-submittal.D00 FROM ST06E CONSTRUCTION PHONE NO. : 2538629635 May. 31 2002 01:30PM P2 tl. Request for Approval of � Wasiiinyton State Materials Source '!o Departniettt of Transportation 17 A. Nlitnf.mr �'�ft i:7:►I(; SE'GjlU1► ; C(Xilfly. r;r.,,Ui:►clor ,. . ... . SubIT►illecJr3y .. ......................._.__ __ _. .._ i•n F•�^.I•.+.,.n 1 0 cW 5111111 ,Wq Ilvel:c!K)c fur i1mil"IcIRID.r•. ..Fer W.$D. T.Use --_—. CONTRAOT Bib IT eOURCG Mnl F.I11A1011 NAMI,Of.MANUF-AC rullEhd'AHNICA I UI I r14;Cu'ICAI,pN APIIIIt, A111111. 11II.6 0AANUVACtURCI1'S PNOOMMVP1; onIII'1 NUMIK-11 nF.l FRI.NCF COIX COUF. NO rTIf A OWL NIOXC I FtJC,NFL• Il L)A t f; 110S MA KPIA1.S i:NGINI[ti h UA I F. Approval Action Codes for use by Proioct Engineer and NQ Materials Laboratory I Source Approved- Acceptance based upon'Salisfaclory'1'est Reporl lore somples of malerlals to be irlcorllofaled into pr 4KI. 2. Source Aoproved: Submit Mfcg.Cett,nl Compliance for'Approval'prior to UsP of malerial ? Source.Approved: %lbmil Calafrlg Cuts for'Apploval'prior to uSe Of malarial. d Soutee Approved: Subntfl Shop Drawings for'Approvat'prior to fabricaliOh of tnatolfai. 5. Source Approved: Only maloriplF idenliked'Approved for Shiprhertl'by WSDOT Fabricaliorl Inspecliort Office prior to shipment to be used. R. Source Approved: Materials to be certified as either 100%,American manufacturer or idCntilicalion of foreign manufacturer and malerinls cost within the permissible limits for the project(See Special Provisions). i. Approvol Pending: Rawest Transmifted to Hdglr,lab.for Approval Action. S. Source Approved: Remarks Approval Aetian Coders for Headqunrlers laboratory use—only 9. Source Approved Approval of Choose of source must be secured Irom headquarters Materials Engineer per sld.5pecilicalions. 10. Aovsuval Withhold: SUbmil Samples for preliminary guilualion. 11. Approval Withheld: 12. Remarks: Project 6 neor Dlslributton II:ityl"a•v Plelr161tl1e„ cenlraetor 140 Male Lab(General File)me Oial.Over.Engr../ HO Mass Lab(Flee)(ell E&s Codes) pwt Mats Z HO Mals Lab(Asphalt)(ell B codes) HO Mats lab(Docun+)1�_ Seattle Inap.Office(all 5 codes) ( )Mandatory Distribution Prhject Erx)u>Eer IYjt 14p.(171 Supersedes Previous Editions Other 1'PWR,36 Sewer and Drain Products Submittal and Data Sheet February 2000 Solid Wall Sewer Pipe - SDR 35 Gasketed ASTM D 3034 Nominal Average Base Minimum Approximate Weight Approximate Weight Pipe Size Outside Diameter Inside Diameter Wall Thickness 20' Pieces 13' Pieces (inches) (inches) (inches) (inches) (Ibs/100') (Ibs/100') 4 4.215 3.890 0.120 100 100 6 6.275 5.742 0.180 230 240 ---�-� 8 8.400 7.665 0.240 410 420 10 10.500 9.563 0.300 650 650 y 12 12.500 11.361 0.360 920 940 15 15.300 13.898 0.437 1390 1420 ASTM F 679 Nominal Average Base Minimum Approximate Weight Approximate Weight Pipe Size Outside Diameter Inside Diameter Wall Thickness 20' Pieces 13' Pieces (inches) (inches) (inches) (inches) (Ibs/100') (Ibs/100') 18 18.701 16.976 0.536 2090 2140 21 22.047 20.004 0.632 2920 2990 24 24.803 22.480 0.711 3710 3800 Notes: All sizes have integral gasketed bells;4"is also available with integral solvent-weld bells. Pipe Material: Pipe compound meets ASTM D 1784 cell class 12454 or 12364. Gaskets meet ASTM F 477. Pipe Design: Pipe meets ASTM D 3034 for diameters 4"-15"or ASTM F 679 for diameters 18"-24". All pipe has an SDR of 35 and a minimum pipe stiffness of 46 psi when tested in accordance with ASTM D 2412. Pipe joints meet ASTM D 3212. Agency Listing: Underwriters Laboratories, Inc.®for 4"- 15". Installation: PWPipe sewer pipe should be installed according to the PWPipe Installation Guide for PVC Sewer Pipe. Installation instructions are also found on labels that are included on the pipe. Testing: PWPipe tests its sewer pipe for dimensional compliance, impact resistance,flattening, stiffness, and joint integrity according to ASTM standards. Solid Wall Sewer Pipe - SDR 26 Gasketed ASTM D 3034 Nominal Average Base Minimum Approximate Weight Approximate Weight Pipe Size Outside Diameter Inside Diameter Wall Thickness 20' Pieces 13'Pieces (inches) (inches) (inches) (inches) (Ibs/100') (Ibs/100') 4 4.215 3.801 0.162 140 140 6 6.275 5.612 0.241 330 340 8 8.400 7.488 0.323 600 600 10 10.500 9.342 0.404 930 950 12 12.500 11.102 0.481 1330 1340 15 15.300 13.575 0.588 2010 2050 Notes: All sizes have integral gasketed bells. Pipe Material: Pipe compound meets ASTM D 1784 cell class 12454 or 12364. Gaskets meet ASTM F 477. Pipe Design: Pipe meets ASTM D 3034. All pipe has an SDR of 26 and a minimum pipe stiffness of 115 psi when tested in accordance with ASTM D 2412. Pipe joints meet ASTM D 3212. Agency Listing: Underwriters Laboratories, Inc Installation: PWPipe sewer pipe should be installed according to the PWPipe Installation Guide for PVC Sewer Pipe. Installation instructions are also found on labels that are included on the pipe. Testing: PWPipe tests its sewer pipe for dimensional compliance, impact resistance,flattening, stiffness, and joint integrity according to ASTM standards. P.O.BOX 10049 EUGENE, OREGON 97440 (541)343-0200 FAX(541)686-9257 MKT-F-702A 'jPWHA1W Waterworks Pressure Water Pipe Products Submittal and Data Sheet October 1998 AWWA C900 Distribution Pipe, Cast Iron Pipe Size (Gasketed) Pressure Class 100 psi -DR 25 UL Listed Nominal Average Approximate Minimum Approximate Pipe Size Outside Diameter Inside Diameter Wall Thickness Weight (inches) (inches) (inches) (inches) (Ibs/100') 4 4.800 4.39 0.192 193 6 6.900 6.31 0.276 398 8 9.050 8.28 0.362 685 10 11.100 10.15 0.444 1030 12 13.200 12.08 0.528 1457 Pressure Class 150 psi - DR 18 UL Listed, FM Approved Nominal Average Approximate Minimum Approximate Pipe Size Outside Diameter Inside Diameter Wall Thickness Weight (inches) (inches) (inches) (inches) (Ibs/100') 4 4.800 4.23 0.267 264 6 6.900 6.08 0.383 543 8 9.050 7.98 0.503 936 10 11.100 9.79 0.617 1408 12 13.200 11.64 0.733 1989 Pressure Class 200 psi -DR 14 UL Listed, FM Approved Nominal Average Approximate Minimum Approximate Pipe Size Outside Diameter Inside Diameter Wall Thickness Weight (inches) (inches) (inches) (inches) (Ibs/100') 4 4.800 4.07 0.343 333 6 6.900 5.85 0.493 688 8 9.050 7.68 0.646 1182 10 11.100 9.41 0.793 1779 12 13.200 11.20 0.943 2516 AWWA C905 Transmission Pipe, Cast Iron Pipe Size (Gasketed) Pressure Rated 165 psi -DR 25 UL Listed Nominal Average Approximate Minimum Approximate Pipe Size Outside Diameter Inside Diameter Wall Thickness Weight (inches) (inches) (inches) (inches) (Ibs/100') 14 15.300 14.00 0.612 1950 16 17.400 15.92 0.696 2522 18 19.500 17.84 0.780 3213 20 21.600 19.76 0.864 3942 24 25.800 23.61 1.032 5603 Pressure Rated 235 psi -DR 18 UL Listed Nominal Average Approximate Minimum Approximate Pipe Size Outside Diameter Inside Diameter Wall Thickness Weight (inches) (inches) (inches) (inches) (Ibs/100') 14 15.300 13.49 0.850 2664 16 17.400 15.34 0.967 3447 18 19.500 17.20 1.083 4389 20 21.600 19.05 1.200 5386 24 25.800 22.76 1.433 7728 Pipe Material: Pipe compound meets ASTM D 1784,cell class 12454. Pipe Joints: Pipe is manufactured with thickened integral bells;bells include elastomeric gaskets. The gasket meets the requirements of ASTM F 477. Agency: Certified by Underwriters Laboratories,Inc.®to ANSI/NSF Standard 61.Underwriters Laboratories,Inc.®also tests our C900 to the requirements of the Uniform Plumbing CodeTM. Installation: The pipe system design engineer and installer should refer to the following installation guides: AWWA C605 and PWPipe's Installation Guide for PVC Water Pipe. Hydrostatic Proof Testing: Every standard and random length of PWPipe's C900 and C905 pipe is individually pressure tested to the requirements of AWWA. PWPipe C900IC905 products also undergo additional in-house quality assurance testing,such as impact resistance,flattening,quick burst,and extrusion quality, where applicable. P.O.BOX 10049 EUGENE,OREGON 97440 (541)343-0200 FAX(541)686-9257 MKT-F-701 m SDR 35 (PS46) FITTING SPECIFICATIONS 1.0 GPK PVC Sewer Fittings shall be manufactured in accordance with either ASTM D-3034, F-1336 or F-679. The PVC material shall have a minimum cell ciassificafiion of 12454-B, 12454-C or 12364-C as defined in ASTM D-1784. 2.0 The purpose of GPK in-line fittings is to convey municipal sanitary and industrial wastes,storm water run-off and many other related applications. They are designed to be used In gravity flow and low pressure applications not to exceed 10.8 psi, 3.0 Injection Molded Fittings are produced in sizes 4"through 8"diameter. Fabricated Fittings are produced in sizes 4"through 27"diameter. A fabricated fitting is considered any fitting made from pipe or a combination of pipe and molded components. 4.0 Chemical Resistance. GPK fittings resist attack from certain alcohols, alkalies,salt solutions,acids and other types of chemicals, Refer to chemical resistance chart. 5,0 Marking. GPK fittings shall be marked with applicable size, "PVC", company name or logo,PSM and the ASTM spectficatlon number(D-3034, F-1336 or F-679), The fittings and/or packaging shall Include the manufacturer's date and shift code. 6.0 Testing. A test after Installation of either low pressure air(Uni-B-6)or a water Infiltration-exfiltration test Is recommended. 7.0 Deflection Test. The maximum allowable pipe's fitting deflection should be 7 1/2%of base ID as shown in Table XI.I of D-3034. 8.0 Backfiliing and Tamping. Backfilling should follow closely after assembly of pipe and fittings. 8.7 Backfiliing with proper material is important to achieve desired density In haunching area which enables pipe, fitting and soil to work together to meet designed load requirements. This eliminates excess deflection and shear breaks due to heavy loads. Approved material shall be used properly,compacted continuously above and around the pipe and fittings as well as between the fitting and trench wall. A cushion of approved material up to a minimum of 12"over the fittings and between the trench walls shall be done in accordance with the engineers'specifications. 8.2 Tamping. This shall be done by hand tamping of the embedment material between the trench wall of the service line fitting and riser connection. Tamping can also be done by mechanical tampers or by using water to consolidate the embedment material, Extreme unstable ground conditions may require wider trenches to enable you to compact a larger area around the pipe and fittings to the density consistent of the original ground surface conditions. 9.0 Service lanes. Normally, service lines from the property line to the collection sewer should be a minimum depth of 3 feet at the property line and should be laid In straight alignment and uniform slope of not less than 1/4"per foot for 4"nominal pipe and 1/8"per foot for 6"pipe. Where collection sewers are deeper than 7 feet a vertical standpipe of stack is permitted. Deep sewer chimney and risers necessitate extreme care during backfilling. Where surface loading Is anticipated the final backfill must be compacted to a density compatible with those surface loads to be encountered. 9.1 Backfllling around pipe service laterals on slope. Extra attention should be given on slopes to prevent the newly backfilled trench from becoming a "French Drain." Before backfiliing completely there is a tendency for ground and surface water to follow the direction of the looser soil. This flow may wash out soil from under or around pipe and branch line fittings,reducing or eliminating the support needed. To avoid this problem the backfilling should be of greater compaction, Tamping should be done in 4" layers and continued in this manner all the way up to ground or surface line of the trench. Concrete collars or other concrete poured around the fitting to stabilize unwanted movement Is recommended to prevent water from undercutting the underside of the pipe and fittings. SUMMARY: Due to various ground conditions and different situations,Installation techniques vary widely. We warranty our products to be free of manufacturer's defects. We will not replace the products that are installed or used Incorrectly, The design of the systems that our product is used in Is a factor that cannot be overlooked, Ilium WH PIPE & PRODUCTS MOT standard plan B-236 and Seattle We 200 TOP UNIT Grade adjustments rings available PLAN VIEW in 2",4"and 6". Concentric or-eccentric cones or ------ flat tops optional. A ;' Flat Top Slabs come with 25" A Copenings offset to one side or �, centered in slab. + Reinforcing is 0.12 i&Aayer/LF f minimum. DETAIL A SECTION Sections are available in heights of I'thru 4'. �-- 25" --( All joint are designed for use with 1'-6"or 3' Rubber Gaskets_ 8 b Steel Reinforced Polypropylene Steps and APWA ladders are OSHA approved and installed as required Circumferential wall reinforcing 2",4",6" :. �. OPTIONAL is 0.12 W/LF minimum BASE UNIT � Base units are available in 2',3',4' and 5'heights. 1'-6"OR 3' Qe 3,/2" Ran mo g is O.15inZ/LF r a \ a 6 All units meet or exceed ASTM C 78. 1,,2',3'&4, ► " PIPE PENETRATIONS s a a Cored holes or blockouts TYPICAL RUBBER available as required GASKET CONNECTION 5 �► � Maximum hole size is 36". 2',3' 4&S' a ► Minimum distance between holes i. a is 8 . SEE DETAIL A WEIGHTS �4 6" 48"x2'Base-2,780 lbs. SECTION AA Additional Footage-9201bs.per ft. 48"Sections-920 lbs per ft. 48" 48"x8"Flat Slab Top- 1,900 lbs. 48"x18"Top Cone-1,5801bs. 58" 48"06"Top Cone-2,420 lbs. TUCOma 4601 S.Orchard i Fardland 755 HE Columbia Bird. Salem 5032 Dallas Hwy,NW Deschutes 835 SE First St. CO.cox 9156 1 PO.Box 11305 PO.Box 5249 Redmond,OR 97756 Tacoma,MIA 98409 - Podland,OR 97211 Salem,OR 97304 (541)923-6063 (253)4754888 i (503)285-8391 (503)585-7350 (541)923-6115(FAX) (800)922-S338 (360J574-3666 (800)452 0339 ' i (253)4714747(Fax) (503)286-0603(FAX) (503)362-SS26(FAX) mom mom 0"Han PIPE & PRODUCTS 9DOT standard plan 17-23a and Seattle type 201 PLAN VIEW TOP UNIT Grade adjustment ring available in A A 2",4",and 6". Concentric or eccentric cones or flat tops optional. Flat top slabs come with 25" openings offset to one side or — -' centered in slab. Reinforcing is 0.12 in2/layer/LF minimum. 25" �--, - sEcrioN 2 � Sections are available in heights ------- of2'to6'. Steel reinforced polypropylene 2-5n steps and APWA ladders are OPTIONAL OSHA approved and are installed 4" 4"_ F as required. Lift holes provided for handling . ! and must be grouted up from both Zt inside and out side to assure a watertight structure. ———————— Circumferential reinforcing is ,a 0.135in' /LF minimum. 4y4^ BASE UNIT (� (: I Base units are available in 2' 3 —.1 5 yz L through 8'heights. g — Separate base slab available upon TYPICAL.RUBBER request. •i--i ±, GASKET CONNECTION Lifting hoops cast into base slab 2',3',4',5',6,T OR 8' :1 I for handling. Reinforcing is .1 h 0.19W/LF/minimum. 1• —j• All units meet or exceed ASTM C478. 8" P1PE PENETRATIONS 54" 5►/2" WEIGHTS 65" 54"x T base-3,800 lbs. Cored holes or blockouts additional footage- 1,1201bs/ft available as required SECTION AA 54"sections- 1,120 lbs/ft Maximum hole size is 42". 54"x 8"flat slab top-2,340 lbs Minimum distance between holes Joints use a confined round rubber 54"x 8"base slab-2,1201bs is 8". 54^x 2'top cone-2,225 1bs gasket meeting ASTM C-443. ) 1 Tacoma 1 Porthmd 755 HE Columbia Blvd. Salem 5032 Dallas Hwy.HW Deschutes 935 SE First St. 4601 S.Orchard P.O.Box 11305 PO_Box 5249 Redmond,OR 97756 P.O.6ox 9156 I Portland,OR 97211 Salem,OR 97304 (541)923-W3 Tacoma,WA 98409 (503)285-6391 (503)�-73� (541)923 b115(FAX) (253)47S-8888 I (360)574-3666 (800)452 0339 —roeo rc-1 lot ncno MAYA IS031362-8526(FAX) KOR-N-SEAL® I & II FLEXIBLE PIPE-TO-MANHOLE CONNECTORS SPECIFICATION SHEET Stainless Steel Stainless Steel Korband Pipe Clamp Reinforced EPDM - Nylon Wedge Rubber Connector KOR-N-SEAL I-WEDGE KORBAND CONNECTOR ASSEMBLY install Kor-N-Seal I-Wedge Korband Install Kor-N-Seal II- Wedge Korband Install Pipe Clamp(s) With Socket Wrench &Torque Limiter With Standard Torque Wrench With T-Handle Torque Wrench NPC Inc. 250 Elm Street P.O.Box 301 Milford,N.H.03055,U.S.A. Tel: (603)673-8680 (800)626-2180 EAL �'- Fax: (603)673-7271 �,__..--''� Form SKNS 4196 KOR-N-SEAO I & II SPECIFICATIONS PERFORMANCE Head Pressure C923-7.1 10 psi (23 ft)for 10 min. +10 psi for 10 min. Deflection Test C923-7.2.2 7°in any direction Over 70 in any direction Load Test C923-7.2.3 150 Ibs/in. pipe dia. Over 150 Ibs/in. pipe dia. Performed on all sizes of Kor-N-Seal Connectors with no leakage occurring initially nor during the 24 hour test period. RESILIENT EPDM RUBBER Conforms to ASTM C923 Chemical Resistance D543,at 22°C for 48 h 1 N Sulfuric Acid No weight loss No weight loss 1 N Hydrochloric Acid No weight loss No weight loss Tensile Strength D412 1200 psi 1580 psi Elongation at Break 350%min. 500% Hardness D2240(shore A durometer) ±5 from the manufacturer's 43±5 specified hardness Accelerated Oven-aging D573 70±1°C for 7 days Decrease of 15%,max.of original 10.1% tensile decrease tensile strength,decrease of 14.0% elongation decrease 20%max.of elongation Compression Set D395,method B,at 70°C for Decrease of 25%,max.of original 13%decrease 22 In deflection WaterAbsorption D471,immerse 0.75 by 2-in. Increase of 10%,max.of original .8%increase specimen in distilled by weight water at 70°C for 48 h Ozone Resistance D1149 Rating 0 Rating 0 Low-temperature Brittle Point D746 No fracture at-40°C No fracture at-40°C Tear Resistance D624,method B 200 Ibf/in. No tear at 210 Ibf/in. INTERNAL KORBAND Conforms to ASTM C923 and ASTM A167 Korband Assembly with toggle-type expander is manufactured of 304 series non-magnetic stainless steel. Korband Assembly with wedge-type expander is manufactured of 304 series non-magnetic stainless steel. The Kor-N-Seal I wedge assembly is manufactured from reinforced nylon. EXTERNAL PIPE CLAMP Conforms to ASTM C923 and ASTM A167 External take-up clamps are manufactured of 304 series non-magnetic stainless steel. The bolt assembly is manufactured of 305 Series non-magnetic stainless steel. NPC Inc. qD 250 Elm Street, P.O. Box 301, Milford, NH 03055 U.S.A. E�QL Tel: (800)626-2180 (603)673-8680 Fax: (603)673-7271 v Polypropylene HangingLadder EMEW Created exclusively for LANE Poly Steps �b a Conforms to: � � u If Polypropylene ASTM D-4101 %d. II 1/l" Grade 60 Reinforcing Bar A-615 If 9/ 16" Cold Drawn Bar. C-1018 • II II ' II . II o� I tl II o' 'I . a tl o• II I, Rail 'I 9/16" Round Bar II II II If d II O II O fl II � II �. o 0 : 1 tt � II II ,o Rung 1/2" Grade 60 q" II II Patent Pending II CORPORAT/OY PO Sox 925 • 18067 S.W. Lower Boones Ferry Road • Tualatin, OR • 97062 • Phone (503) 684-0077 FAX (503) 684.0078 6P.nn®f AR.n 7& E= PRODUCT GUIDE HIGH•TECH COATINGS PRODUCT: MC-ConsealTM - USDA/FDA Approval � . • Single component, moisture-cure, high solids • Solids by Volume: 61.0 ±2.0% urethane • Weight per Gallon: 8.3 ±0.2 lbs/gal • Chemical and sulfide resistant concrete coating . Viscosity @ 75' F: <60KU • Cold, damp application tolerant coating • Volatile Organic Content (VOC): Less than 2.8 lb/gal • High solids, VOC compliant coating (340 g/1) • Pigment Type: Clear or Off White ® • Flash Point: Above 103' F • Sealer for interior of new concrete sewer pipe, • Theoretical Coverage: 978 sq ft per gallon at 1 mil DFT manways or vaults • Chemical and sulfide resistant protective coating • Recommended Dry Film Thickness: 1.5 - 2.5 mils DFT (2.5 - 4.0 mils wet) per coat. Avoid excessive for concrete films. Dry films over 3 mils DFT per coat may show • Mixed with aggregate as sealer for stress cracks bubbling. Use 2 coats • Compatible with PURQuikTm Accelerator System • Temperature Resistance (Dry): 275' F continuous 300' F intermittent • Chemical Resistance: See "Wasser Chemical Resis- F A tance Chart" • Curing Time @ 75' F: Touch - 30 min; Handle - 12 • Single component - no catalyst mixing errors hr; Recoat - 4 hrs; Stack - 24hrs • Can be applied in cold, damp conditions - at • Recoatability: After 72 hours, abrade surface humidties to 99% • Can be applied at low temperatures - to below • Color: Clear, white freezing. Avoid frozen surfaces (no ice or frost) • Finish: Gloss • Typical urethane abrasion resistance and all-around • Shelf Life: 12 months from date of shipment in performance in harsh environments unopened original container • VOC compliant • Superior adhesion to concrete • Excellent resistance to hydrogen sulfide fumes typically found in sewers and manways • Meets United States Department of Agriculture requirements for incidental food contact • Complies with FDA 21 CFR 175.300 for direct food contact 8041 South 228th Street• Kent,Washington 98032 U.S.A.•(253) 850-2967• Fax (253) 850-3098 10/97 MC-CS http://www.wassercoatings.com WATIN . EA 99 ♦ 1 1021W • This product is primarily recommended for coating Consult "Wasser Application Guides" or a Technical interior sewer and manway concrete surfaces. Sweep Representative for specific system recommendations. blast, or full blast to remove all laitance, dirt, organic Consult "Wasser Application Instructions" and "Steel : coatings or unsound concrete. Structures Painting Council SSPC-PA 1 - Good Paint- ing Practices". Consult Wasser's "Application Instructions For Paint- ing Concrete" when applying on concrete. Product will yellow on UV exposure. Additionally interior applications with high intensity UV lighting (metal halide) may cause slight yellowing. Perform a test patch or consult a Wasser Technical Representa- tive if color is an issue. Thin only with Wasser MC-Thinner or MC-Thinner 100. Use MC-Thinner 100 in brush and roll applications. Improper thinners will cause gelation or improper cure! If VOC regulations restrict thinning, use Wasser MC-Thinner XMT. Do not apply to wet surfaces or ice. Excessive film will require longer cure times and may cause poor adhesion, blistering, pinholing, solvent entrapment and may require remedy. Consult Wasser Technical Representative for more information or if films exceed 100% of upper recommended Dry Film ♦ ♦ Thickness. WASSER HIGH-TECH COATINGS warrants its products to be free from defects in materials. Wasser High-Tech Coatings' sole obligation and Buyer's exclusive remedy in connection with the products shall be limited,at Wasser High- Tech Coating's option,to either replacement of products not conforming to this Warranty or credit to Buyer's account in the invoiced amount of the nonconforming products. Any claim under this Warranty must be made by Buyer to Wasser High- Tech Coatings in writing within five(5)days of Buyer's discovery of the claimed defect,but in no event later than the expiration of the applicable shelf life,or six months from the delivery date,whichever is earlier. Buyer's failure to notify Wasser High-Tech Coatings of such nonconformance as required herein shall bar Buyer from recovery under this Warranty. Wasser High-Tech Coatings makes no other warranties concerning the products. No other warranties, whether express, implied, or statutory, such as warranties of merchantability or fitness for a particular purpose,shall apply. In no event shall Wasser High-Tech Coatings be liable for consequential or incidental damages. Any recommendation or suggestion relating to the use of the products made by ♦ ♦ • Wasser High-Tech Coatings,whether in its technical literature,or in response to III specific inquiry,or otherwise,is based on data believed to be reliable;however,the products and information are intended for use by Buyers having requisite skill and This product is for industrial use only. know-how in the industry,and therefore it is for Buyerto satisfy itself ofthe suitability of the products for its own particular use and it shall be deemed that Buyer has done ' WARNING: Vapor and spray mist are harmful. so,at its sole discretion and risk. variation in environment,changes in procedures Consult the Material Safety.Data Sheet. Use an ap- of use,or extrapolation of data may cause unsatisfactory results. proved respirator when applying this product. Consult • ' : �Wassers liability on any claim of any kind,including the MSDS sheet for recommendations. Protect skin claims based upon Wasser's negligence or strict liability,for any loss or damage and eyes from contact. This product contains organic arising out of,connected with,or resulting from the use of the products,shall in no y p g case exceed the purchase price allowable to the products or part thereof which give solvents and polyisocyanates. Do not use if you have a rise to the claim. In no event shall Wasser be liable for consequential or incidental chronic or allergic reaction to isocyanates or organic damages.Published Product Data Sheets are subject to change without notice. Contact your Wasser Representative for current Product Data Sheets. Solvents. 10/97 MC-CS TYTON JOINTO Pipe 4 " - 64 " Ductile Iron ' For Water and Wastewater, Fire Protection and Industrial Applications 2001 Edition 1 k III FNv� j YY �e 1 i t NSF Certified CO ANSUNSF 61 TYTON JOINT° Pipe TYTON JOINT®is U.S. Pipe's trademark for pipe Ductile Iron TYTON JOINT Pipe are centrifugally with a push-on type connection. Simplicity, sturdiness and cast in metal molds in accordance with ANSI/AWWA water-tightness of the system are built into the system by C151/A21.5I Ductile-Iron Pipe, Centri fugally Cast for Water. design.Taking advantage of a background of more than TYTON JOINT Pipe, sizes 4"-16," is UL listed and 100 years experience with pipe and pipe connecting systems, FM approved. U.S. Pipe made a thorough study of existing joining systems The asphaltic outside coating is in accordance with and requirements of pipe users.The results of this study ANSI/AWWA C151/A21.51. The cement-mortar lining showed the need for a simple, economical and reliable and inside coating are in accordance with ANSI/AWWA method of assembling pipe.A number of new designs were C104/A21.4 Cement-Mortar Lining for Ductile-Iron Pipe devised.A rigorous testing process resulted in the selection of and Finings for Water.Special linings and/or coatings can be the TYTON JOINT Pipe System. furnished for specific conditions. After selection of the system,TYTON JOINT Pipe Sizes 4" through 42" are furnished in nominal 18-foot were then subjected to further testing designed to simulate laying lengths.Sizes 48"through 64"are furnished in nominal extreme installation and service conditions which might be 20-foot laying lengths. encountered in the field. It was only after these tests As specified in ANSI/AWWA C151/A21.51, pipe proved completely satisfactory and were confirmed by field weights have been calculated using standard barrel weights installations that the decision was made to market and weights of bells being produced. TYTON JOINT Pipe in 1955. Convincing proof of its wide When joint restraint is required for push-on joint pipe, acceptance is shown by the fact that more than 95%of the two options are available from U.S. Pipe. For joint restraint pipe now sold by this company is TYTON JOINT Pipe. of 4"through 24", FIELD LOK 3500 Gaskets may be used. The TYTONO Gasket—a circular rubber gasket which FIELD LOK 350 Gaskets are rated for 350 psi in sizes 4" has a modified bulb shape in cross section—is the only through 24". In addition,for 4" through 64"sizes,TR FLEX® required accessory.They are furnished in accordance with Pipe and Fittings may be used.TR FLEX Pipe and Fittings ANSI/AWWA C111/A21.11 Rubber-Gasketjoints for are rated for working pressures for 350 psi in 4" through Ductile-Iron Pressure Pipe and Fittings. Composition and 24" sizes, 250 psi in sizes 30" through 48", and 200 psi in dimensions of the gasket have been carefully engineered to sizes 54" through 64". For higher pressure applications ensure a water-tight and lasting seal.The standard TYTON contact your U.S. Pipe representative. Complete details on Gasket is manufactured of SBR-styrene butadiene rubber. both FIELD LOK 350©Gaskets and TR FLEX®Pipe and Gaskets of special elastomers may be ordered for special Fittings can be found on our website,www.uspipe.com. applications. The gasket contour and bell socket contour ensure that the gasket will remain seated during proper assembly of the pipe. The plain end of the pipe is furnished beveled to ease assembly. Because TYTON JOINT Pipe assembles so easily, those not experienced with it may think that the system is not water-tight. More than 40 years of successful experience have proved its sealing capabilities. Hydrostatic tests have shown that the system will withstand pressures far in excess of rated pressures. When TYTON JOINT Pipe are used for bridge crossings or other above-ground installations,each length of pipe must be supported in a manner to restrict both vertical and horizontal movement Note: If specifiers and users believe that corrosive soils will be encountered where our products are to be installed,please refer to ANSI/AWWA C105/A21.5 Polyethylene Encasement for Ductile Iron Pipe Systems,for proper external protection procedures. U.S.Pipe qualifies for Federal Procurement under Public Law No.94-580,Section 6002,known as the Resource Recovery Act of 1976,since,due to modern technology, recycled iron and steel scrap is used to a large degree in our Ductile Iron Pipe production. TYFON@,TTTON JOINT@,TR FLEX®,and FIELD LOK 350@ are registered trademarks of U.S.Pipe and Foundry Company. TP 1 i �7 NOTE: Actual bell configuration may vary from ' illustration shown. 3 P i e I ff I I A Dimensions of Bells* Pipe g C Size O.D. Bell O.D. Socket Depth 4 4.80 6.52 3.15 6 6.90 8.66 3.38 ----'�' 8 9.05 10.82 3.69 10 11.10 12.91 3.75 12 13.20 15.05 3.75 14 15.30 17.62 5.00 16 17.40 19.74 5.00 18 19.50 21.86 5.00 20 21.60 23.98 5.50 24 25.80 28.16 5.95 30 32.00 35.40 6.55 36 38.30 41.84 7.00 4 42 44.50 49.36 7.90 48 50.80 55.94 8.60 54 57.56 62.63 9.40 60 61.61 66.63 10.10 64 65.67 70.80 1 10.65 *Subject to manufacturing tolerances. Dimensions in inches. TP 5 Thicknesses, Dimensions and Weights of Ductile Iron TYTON JOINT° Pipe Thickness Class Thicknesses and dimensions of 4" through 64" Ductile Iron pipe conform to ANSI/AWWA C151/A21.51. Weights may vary from the standard because of differences in bell weights. 18-Foot Laying Length Size Thickness Outside Weight Per Avg.Weight Inches Class Thickness Diameter* Lengtht Per Foottt Inches Pounds 4 51 0.26 4.80 215 11.9 4 52 0.29 4.80 235 13.1 4 53 0.32 4.80 260 14.4 4 54 0.35 4.80 280 15.6 4 55 0.38 4.80 300 16.7 4 56 0.41 4.80 320 17.8 6 50 0.25 6.90 305 16.9 6 51 0.28 6.90 335 18.6 6 52 0.31 6.90 370 20.6 6 53 0.34 6.90 400 22.2 6 54 0.37 6.90 435 24.2 6 55 0.40 6.90 465 25.8 6 56 0.43 6.90 495 27.5 8 50 0.27 9.05 430 23.9 8 51 0.30 9.05 475 26.4 8 52 0.33 9.05 520 28.9 8 53 0.36 9.05 560 31.1 8 54 0.39 9.05 605 33.6 8 55 0.42 9.05 650 36.1 8 56 0.45 9.05 690 38.3 10 50 0.29 11.10 570 31.7 10 51 0.32 11.10 625 34.7 10 52 0.35 11.10 680 37.8 10 53 0.38 11.10 730 40.6 10 54 0.41 11.10 785 43.6 10 55 0.44 11.10 840 46.7 10 56 0.47 11.10 890 49.4 12 50 0.31 13.20 725 40.3 12 51 0.34 13.20 790 43.9 12 52 0.37 13.20 855 47.5 12 53 0.40 13.20 920 51.1 12 54 0.43 13.20 985 54.7 12 55 0.46 13.20 1045 58.1 12 56 0.49 13.20 1110 61.7 * Tolerance of O.D.of spigot end:4-12 in.,t0.06 in.;14-24 in.,+0.05 in.,-0.08 in.; 30-48 in.,+0.08 in.,-0.06 in.;54-64 in.,+0.04 in.,-0.10 in. f Including bell;calculated weight of pipe rounded off to nearest 5 lbs. ff Including bell;average weight,per foot,based on calculated weight of pipe before rounding. TP 9 28 U AW TECHNI ML/ JU91111 I I ML VM I M C 110 FLANGED FITTINGS V' RecommendedS eci ications PO'Dimensions and Weiqhts Apolication Information i?'Dijifile Iron 41 V3, yision o fRansam lnduslries,LP MADE IN THE AM _Mff [ USA ] Tyler Pipe/Utilities Division 9 P.O.Box 2027 • Tyler, Texas 75710 • (903) 882-5511 MIZA? W ` DUCTILE IRON C 110 FLANGED FITTINGS SAMPLE SPECIFICATION Flanged Fittings, 2" through 30" shall be manufactured in the USA of Ductile Iron in accordance with all applicable terms and provisions of standards ANSI/AWWA Cl 10/A21.10 (current revisions). All Ductile Iron Flanged Fittings shall be rated for water pressure of 250 PSI. FLANGE DETAILS O O Nominal Dia. of Flange Pipe Size Flange Bolt Thickness Bolt Hole Number Bolt Dia. O sp O �? Inch O.D. Circle T Diameter of Bolts and Lengths F' B.C. ' 2 6 4.75 .62 .75 4 s/8 x 21/4 O 3 7.5 6 .75 .75 4 5/8 A 21/2 4 9 7.5 .94 .75 8 s/8 x 3 O O 6 11 9.5 1.00 .875 8 3/4x 3'/2 8 13.5 11.75 1.12 .875 8 3/4x 31/2 10 16 14.25 1.19 1.00 12 7/8 x 4 " 12 19 17 1.25 1.00 12 7/8 x 4 O.D. 14 21 18.75 1.38 1.125 12 1 x 4'/2 16 23.5 21.25 1.44 1.125 16 1 x 41/2 18 25 22.75 1.56 1.25 16 11/8 x 5 T 20 27.5 25 1.69 1.25 20 1'/8x 5 T 24 32 29.5 1.88 1.375 20 1'/4x 5'/2 T 30 38.75 36 2.12 1.375 28 1'/4 x 6'/2 NOTE: Drilling templates are in multiples of four, so that fittings may be made to face NOTE: No flange joint in any quarter. Bolt holes shall straddle the center line. S1 material furnished. \r titiS'I� fig° 0.Q O� a, "a . n .dp Q o BENDS211, 311 411, 6", 8" 1 0", 1211, 14" 1 6", 1 8" 2011, 2411 Note: Base Bends are on page 5 and 6,reducing and long radius 900 bends are on page 5. A� �P� 4> A7 A A� i R R 90° Bends (1/4) 450 Bends (1/8) 22'/20 Bends 0/16) 11'/40 Bends (1/32) Dimensions Dimensions Dimensions Dimensions Size R A Weight R A Weight R A Weight R A Weight 2 3.0 4.5 14 ... ... ... ... ... ... 3 4 5.5 25 3.62 3 20 7.56 3 20 15.25 3 20 4 4.5 6.5 48 4.81 4 42 10.06 4 40 20.31 4 40 6 6 8 74 7.25 5 66 15.06 5 64 30.5 5 55 8 7 9 118 8.44 5.5 105 17.62 5.5 90 35.5 5.5 90 10 9 11 190 10.88 6.5 154 22.62 6.5 130 45.69 6.5 159 12 10 12 275 13.25 7.5 195 27.67 7.5 231 55.81 7.5 195 14 11.5 14 330 12.06 7.5 245 25.12 7.5 250 50.75 7.5 245 16 12.5 15 430 13.25 8 315 27.62 8 315 55.81 8 315 18 14 16.5 530 14.5 8.5 375 30.19 8.5 385 60.94 8.5 385 20 15.5 18 685 16.88 9.5 595 35.19 9.5 505 71.06 9.5 505 24 18.5 22 1085 18.12 11 730 37.69 11 755 76.12 11 760 30 21.5 25 1755 27.75 15 1335 ... ... 1385 116.75 15 1395 ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 2 Tyler Pipe/Utilities Division 0 P.O. Box 2027•Tyler,Texas 75710 • (903)882-551 1 4-12-99 DUCTILE IRON C1 10 FLANGED FITTINGS TEES, REDUCING TEES, CROSSES H H rH H �H H H �H H � I I iJ I J I J I J J J Straight Tees, Reducing *Reducing *Reducing on *Bullhead Straight and on Branch Tees on Run Run and Branch Tees Reducing Crosses Size Dimensions Weights Size Dimensions Weights Run Run Branch H J Tee Cross Run Run Branch H J Tee Cross 2 2 2 4.5 4.5 20 *t12 8 8 12.0 12.0 375 ... 3 3 2 4.5 4.5 35 ... *t12 8 12 12.0 12.0 420 ... 3 3 3 5.5 5.5 40 50 *tl2 10 6 14.0 14.0 390 ... 4 3 3 6.5 5.5 55 ... *t12 10 8 12.0 12.0 400 *4 4 2 6.5 6.5 62 ... *t12 10 10 12.0 12.0 420 ... 4 4 3 6.5 6.5 60 78 *t12 10 12 12.0 12.0 440 4 4 4 6.5 6.5 60 92 12 12 4 12.0 12.0 322 310 *4 4 6 8.0 8.0 90 ... 12 12 6 12.0 12.0 295 355 *6 4 4 8.0 8.0 103 ... 12 12 8 12.0 12.0 346 383 *6 4 6 8.0 8.0 108 12 12 10 12.0 12.0 394 415 *6 6 2 8.0 8.0 156 ... 12 12 12 12.0 12.0 408 494 6 6 3 8.0 8.0 85 107 *14 14 4 14.0 14.0 410 6 6 4 8.0 8.0 90 110 14 14 6 14.0 14.0 420 450 6 6 6 8.0 8.0 112 141 14 14 8 14.0 14.0 435 475 6 6 8 9.0 9.0 140 ... 14 14 10 14.0 14.0 450 ... *8 6 4 9.0 9.0 146 ... 14 14 12 14.0 14.0 470 555 *8 6 6 9.0 9.0 148 ... 14 14 14 14.0 14.0 500 595 *8 6 8 9.0 9.0 145 ... *16 16 4 15.0 15.0 525 8 8 3 9.0 9.0 130 140 16 16 6 15.0 15.0 540 565 8 8 4 9.0 9.0 150 155 16 16 8 15.0 15.0 555 590 8 8 6 9.0 9.0 183 191 16 16 10 15.0 15.0 565 620 8 8 8 9.0 9.0 179 195 16 16 12 15.0 15.0 590 665 *8 8 10 11.0 11.0 260 ... 16 16 14 15.0 15.0 610 *8 8 12 12.0 12.0 291 ... 16 16 16 15.0 15.0 635 755 *t10 6 6 13.0 13.0 275 ... 18 18 6 13.0 15.5 641 ... *t10 6 10 13.0 13.0 305 ... 18 18 8 13.0 15.5 652 ... *t10 8 6 13.0 13.0 280 ... 18 18 10 13.0 15.5 585 *t10 8 8 13.0 13.0 302 ... 18 18 12 13.0 15.5 605 670 *t10 8 10 13.0 13.0 325 ... 18 18 14 16.5 16.5 740 ... 10 10 4 11.0 11.0 239 220 18 18 16 16.5 16.5 760 10 10 6 11.0 11.0 215 240 18 18 18 16.5 16.5 870 915 10 10 8 11.0 11.0 254 292 * Not included in AWWA C110 10 10 10 11.0 11.0 291 330 t H and J dimensions are two-inches longer than straight tees. 10 10 12 12.0 12.0 355 ... *t12 6 6 14.0 14.0 340 ... *t12 6 8 14.0 14.0 360 ... *t12 8 6 14.0 14.0 355 ... ANSI/AWWA C110/A21.10,ANSI/AWWA C111/A21.11 4-12-99 Tyler Pipe/Utilities Division •P.O.Box 2027•Tyler,Texas 75710• (903)882-551 1 3 23U -Nil er u nnisronAL— MNi%mL//rjUB 0 ( 153 Mech 1114.ul JU1111 AOM 0 Ire M ii* 03 C A - Ma %V MO w V' RecommendedS ec ications Dimensions and Waksis PO App ication In ormanon 1�� Ductile Iron MADE IN THE USA - Tyler Pipe/Utilities Division * P.O.Box 2027 • Tyler, Texas 75710 • (903) 882-551 1 Union Foundry Company - P.O.Box 309 • Anniston, Alabama 36202 0 (205) 236-7901 T rC 153 DUCTILE IRON e n i MECHANICAL JOINT COMPACT FITTINGS U on Sizes 3" thru 12" UL Listed For Fire Main Equipment SAMPLE SPECIFICATIONS �M� �L 3" THRU 24" MECHANICAL JOINT DUCTILE IRON FITTINGS shall be produced in the USA in accordance with all applicable terms and provisions of ANSI/AV,/WA X C153/A21.53 and ANSI/AWWA C1 11/A21.11. All 26° Ductile Iron Mechanical Joint (Only) Fittings are rated for '° s 350 PSI working pressure, unless otherwise indicated. T NOTE: Fittings are cement-lined and seal-coated in accordance with ANSI/AWWA C104/A21.4; also 0.12ln. 2° available double cement-lined or bare. All coated fittings 0.75 in. meet requirements of NSF-61. See list price sheet for 0.31 in. 8- details. K2 1 D C F A K' JOINT DIMENSIONS IN INCHES BOLTS Size A Dia. B C Dia. D Dia. F Dia. 1 Dia. K' Dia. K2 Dia. L M S T X Dia. Size No. 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 1/4 5/8x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 7/a 3/4x3'/2 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 7/8 '/4x3'/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 12.31 13.37 .66 1.00 .45 .38 7/8 3/4x3'/2 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 7/8 3/4x3'/2 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 7/a 3/4x3'/2 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .56 .47 7/8 '/4x4 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .57 .50 7/8 3/4x4 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 7/8 1/4x4 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.08 1.02 1.44 .69 .57 7/8 3/4x4 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 7/8 3/4x.4'/2 16 BENDS R 7A � AJ � T A I+-A-►I T �T � �A 90' Bends (1/4) 45' Bends (1/8) 221/20 Bends (1/16) 111/4. (1/32) Dimensions Dimensions Dimensions Dimensions Size T A R Weight A R Weight A R Weight A R Weight 3 .34 4.5 4.0 20 2.00 3.62 16 1.50 4.98 15 1.25 7.62 15 4 .35 5.0 4.5 26 2.49 4.81 22 1.82 6.66 21 1.55 10.70 20 6 .37 6.5 6.0 48 3.50 7.25 40 2.59 10.50 37 1.81 13.26 33 8 .39 7.5 7.0 68 4.00 8.44 59 2.85 11.80 51 2.06 15.80 48 10 .41 9.5 9.0 136 5.01 10.88 86 3.35 14.35 67 2.32 18.36 61 12 .43 10.5 10.0 141 5.98 13.25 109 3.86 16.90 90 2.56 20.90 79 14 .51 12.0 11.5 220 5.50 12.06 164 3.93 17.25 148 2.59 21.25 133 16 .52 13.0 12.5 264 5.98 13.25 202 3.98 17.50 179 2.62 21.50 159 18 .59 15.5 14.0 410 7.50 14.50 325 7.50 30.19 292 7.50 60.94 320 20 .60 17.0 15.5 505 8.00 16.88 368 8.50 35.19 364 8.50 71.07 346 24 .62 20.0 18.5 695 9.00 18.12 481 9.00 37.69 481 9.00 76.12 457 Tyler Pipe/Utilities Division • P.O. Box 2027•Tyler,Texas 75710• (903)882-5511 2 Union Foundry Company• P.O.Box 309 •Anniston,Alabama 36202 • (256)236-7601 7-17-2000 MECHANICAL JOINT C 153 DUCTILE IRON Tyler/Union COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment BENDS R T %R i / 1 � Y I i- -- Y T 4- -Y V• -Y �1�1 �-Y 90' Bend MJ x PE (1/4) 45' Bend MJ x PE (1/8) 22'/2° Bend MJ x PE (1/16) 11'/4' Bend MJ x PE (1/32) Dimensions Dimensions Dimensions Dimensions Size T A Y R Weight A Y R Weight A Y R Weight A Y R Weight 3 .34 4.5 10.0 4.0 20 2.0 7.5 3.62 17 1.50 7.00 4.98 16 1.25 6.75 7.62 15 4 .35 5.0 10.5 4.5 25 2.5 8.0 4.81 22 1.82 7.32 6.66 20 1.55 7.05 10.70 19 6 .37 6.5 12.0 6.0 45 3.5 9.0 7.25 37 2.58 8.08 13.50 34 1.80 7.30 13.26 32 8 .39 7.5 13.0 7.0 65 4.0 9.5 8.44 56 2.84 8.34 11.80 50 2.05 7.55 15.80 44 10 .41 9.5 15.0 9.0 109 5.0 10.5 10.88 83 3.35 8.85 14.35 66 2.31 7.81 18.36 60 12 .43 10.5 16.0 10.0 135 6.0 11.5 13.25 108 3.86 9.36 16.90 87 2.56 8.06 20.90 76 14 .51 12.0 20.0 11.5 220 5.5 13.5 12.06 165 3.93 11.93 17.25 152 2.59 10.59 21.25 137 16 .52 13.0 21.0 12.5 254 6.0 14.0 13.25 206 3.98 11.98 17.50 181 2.62 10.62 21.50 161 24 .62 17.0 25.0 15.58 710 7.5 16.2 14.69 460 9.00 17.00 37.69 455 9.00 17.00 76.12 475 R I Jp 1 I T F---I �* A -I TV J T�F" I Tj ` 5�A I*A 1-' 90' Bend MJ x Flange 45' Bend MJ x Flange 22'/2° Bend MJ x Flange 11'/4' Bend MJ x Flange (1/4) (1/8) (1/16) (1/32) Dimensions Dimensions Dimensions Dimensions Size T A R F Weight A R F Weight A R F Weight A R F Weight 3 .34 4.5 4.0 5.5 21 ... ... ... ... 4 .35 5.0 4.5 6.5 28 2.50 3.56 4.0 34 1.75 3.81 4.0 34 1.50 5.12 4.0 19 6 .37 6.5 6.0 8.0 46 3.25 5.49 5.0 57 2.25 6.35 5.0 57 1.50 5.12 5.0 30 8 .39 7.5 7.0 9.0 73 4.25 7.93 5.5 83 2.50 7.62 5.5 83 1.75 7.70 5.5 50 10 .41 9.5 9.0 11.0 111 5.00 9.76 6.5 122 3.00 10.16 6.5 122 2.00 10.25 6.5 75 12 .43 10.5 10.0 12.0 153 6.0012.19 7.5 159 3.50 12.70 7.5 159 2.25 12.82 7.5 88 14 .51 12.0 11.5 14.0 227 5.5010.85 8.5 207 16 .52 13.0 12.5 15.0 280 6.00 12.02 9.5 290 rr- - - - 9 -_.-" " T --t ---7 90' Swivel x Swivel Hydrant Ell C T-...-- r-----..- L- E F D Dimensions Size T A B C D E F R 'Weight R _ 1 6 .37 10.5 15.5 6.90 11.2 6.81 7.98 6.0 69 A 'Weight includes two swivel glands. Tyler Pipe/Utilities Division • P.O. Box 2027•Tyler,Texas 75710• (903)882-5511 7-17-2000 Union Foundry Company• P.O. Box 309 0 Anniston,Alabama 36202 • (256)236-7601 3 MECHANICAL JOINT C 153 DUCTILE IRON Tler/Union COMPACT C FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment TEES CROSS Ti J J3 T Ti T J 2 1 j J. i FI FI H H H -�j.-F1 1-1 H T T T T MJ Tee MJ x FE Tee MJ x Swivel Tee Cross Dimensions Weights Size T T' H J' J2 J3 MJ MJxFE MJxSt Cross 3 .34 .34 3.5 3.50 5.5 ... 26 28 33 4x3 .35 .34 3.5 4.00 6.5 ... 32 34 ... 40 4 .35 .35 4.0 4.00 6.5 ... 35 38 ... 42 6x3 .37 .34 3.5 5.00 8.0 ... 47 51 ... ... 6x4 .37 .35 4.0 5.00 8.0 ... 51 54 ... 62 6 .37 .37 5.0 5.00 8.0 10.50 60 68 77 80 8x3 .39 .34 4.0 6.50 9.0 ... 68 ... ... ... 8x4 .39 .35 4.5 6.50 9.0 71 79 ... 84 8x6 .39 .37 5.5 6.50 9.0 11.50 80 86 99 108 8 .39 .39 6.5 6.50 9.0 11.50 90 102 116 115 1Ox3 .41 .34 4.0 7.50 11.0 ... 83 ... ... ... IOx4 .41 .35 4.5 7.50 11.0 83 89 98 1Ox6 .41 .37 5.5 7.50 11.0 13.00 93 110 119 118 1Ox8 .41 .39 6.5 7.50 11.0 13.00 113 115 129 138 10 .41 .41 7.5 7.50 11.0 ... 120 144 155 12x3 .43 .34 4.0 8.75 12.0 ... 100 ... ... 12x4 .43 .35 4.5 8.75 12.0 104 117 123 12x6 .43 .37 5.5 8.75 12.0 14.25 115 133 138 140 12x8 .43 .39 6.5 8.75 12.0 14.25 123 126 149 155 12x 10 .43 .41 7.5 8.75 12.0 ... 153 174 187 12 .43 .43 8.75 8.75 12.0 178 198 212 14x6 .51 .44 6.5 10.50 14.0 16.00 183 205 211 210 14x8 .51 .45 7.5 10.50 14.0 ... 206 ... ... 231 14x10 .51 .46 8.5 10.50 14.0 ... 229 244 ... 255 14xl2 .51 .47 9.5 10.50 14.0 ... 235 284 269 14 .51 .51 10.5 10.50 14.0 281 305 ... 299 16x6 .52 .45 6.5 11.50 15.0 17.00 229 239 248 250 16x8 .52 .46 7.5 11.50 15.0 ... 248 260 ... 264 16x10 .52 .47 8.5 11.50 15.0 265 287 286 16x12 .52 .48 9.5 11.50 15.0 ... 281 312 ... 310 16x14 .52 .51 10.5 11.50 15.0 317 348 16 .52 .52 11.5 11.50 15.0 ... 361 374 ... 410 t Weights include swivel gland NOTICE:Weights published in this catalog are for shipping purposes only. Actual weights may vary because some fittings are produced in both foundries. All fittings are made in the USA and meet the AWWA standards to which they are designed. Compact flanged fittings are made to manufacturer's standards, incorporating AWWA C153 wall thickness and AWWA C1 10 laying lengths. For weights of specific fittings, please contact Tyler Pipe or Union Foundry Company. Tyler Pipe/Utilities Division • P.O. Box 2027•Tyler,Texas 75710• (903)882-5511 4 Union Foundry Company• P.O.Box 309 0 Anniston,Alabama 36202• (256)236-7601 7-17-2000 TY]er Union MECHANICAL JOINT C 153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment TEES (Continued) MJ GLANDS Ti Js T T J2 Glands J Size Weight Size Weight - - - - - 3 3 12 12 F� F� H 4 4 14 16 6 6 16 20 T T T 8 8 18 25 .. 10 11 20 29 MJ Tee MJ x FE Tee MJ x Swivel Tee 24 38 Dimensions Weights Size T T' H J' J2 J3 MJ MJxFE tMJxS 18x6 .59 .44 6.5 12.5 15.5 18.0 275 261 278Retainer Glands, ; 18x8 .59 .45 7.5 12.5 ... 280 351 ... 18x10 .59 .A7 8.5 12.5 ... 286 ... ... 18x 12 .59 .49 9.5 12.5 ... ... 370 ... ... 18x14 .59 .56 10.5 12.5 ... ... 415 ... 18x16 .59 .57 11.5 12.5 ... 445 ... -VARIABLE 18 .59 .59 12.5 12.5 ... 490 ... 20x6 .60 .44 7.0 14.0 17.0 19.5 335 362 358 20x8 .60 .A5 8.0 14.0 ... 383 ... 20x 10 .60 .47 9.0 14.0 ... 410 ... 20x12 .60 .49 10.0 14.0 ... ... 432 ... ... - 20x 14 .60 .56 11.0 14.0 ... ... 475 ... ... 20xl 6 .60 .57 12.0 14.0 ... ... 530 ... ... Swivel x Solid Adapter 20x18 .60 .59 13.0 14.0 ... 560 ... with Swivel Gland 20 .60 .60 14.0 14.0 ... ... 605 ... Size by Wall 24x6 .62 .44 7.0 16.0 19.0 21.5 448 451 461 Laying Length Thickness Weight 24x8 .62 .45 8.0 16.0 ... ... 475 ... 6x13 .37 46 24x10 .62 .47 9.0 16.0 ... 516 ... ... 6x18 .37 . 58 24x12 .62 .49 10.0 16.0 ... ... 549 580 ... 6x24 .37 74 24x14 .62 .56 11.0 16.0 ... ... 585 ... ... 8x12 .39 52 24xl6 .62 .57 12.0 16.0 ... ... 625 744 ... 24x18 .62 .59 13.0 16.0 ... ... 675 ... ... VARIABLE 24x20 .62 .60 15.0 17.0 ... ... 740 ... ... 24 .62 .62 17.0 17.0 ... ... 947 ... - - t Weights include swivel gland. ra MJ x FE Flange Dimensions are on Page 6 Swivel x Swivel Adapter Size by Wall MJ x PE x MJ Tee Laying Length Thickness Weight T 6xl2 .37 28 Dimensions J' Z Size T T' H J' Z Weights 6x18 .37 49 6 .37 .37 5.0 5.0 11.5 57 6x24 37 52 FI 8x6 .39 .37 5.5 6.5 11.5 79 8 .39 .39 6.5 6.5 12.5 83 T 10 .41 .41 7.5 7.5 13.0 133 Tyler Pipe/Utilities Division • P.O.Box 2027•Tyler*Texas 75710• (903)882-5511 7-17-2000 Union Foundry Company• P.O.Box 309•Anniston,Alabama 36202 • (256)236-7601 5 9A , Mueller Co. MUELLER`R' SUPER CENTURION" REV.4-99 FIRE HYDRANT ❑ Super Centurion 250Tm 3-way catalog numbers (approved to UL 262,FM 1120/1130,ANSI/AWWA C502 Standards)--- A421 4-1/2"main valve opening three way (two hose nozzles and one pumper nozzle) F --+A423 5-1/4"main valve opening three way (two hose nozzles and one pumper nozzle) Super Centurion 200rm 2-way catalog numbers (approved to ANSI/AWWA C502 Standards)--- A420 4-1/2"main valve opening two way(two hose nozzles) A422 5-1/4"main valve opening two way(two hose nozzles) ~. A425 5-1/4"main valve opening two way(two pumper nozzles) Super Centurion 200Tm 1-way catalog number ` (approved to ANSI/AWWA C502 Standards)--- A424 4-1/2"main valve opening one way(one pumper nozzle) ❑ 10 year limited warranty on material and workmanship ❑ Meets all applicable parts of ANSUAWWA C502 Standard ;, " ❑ Post type dry barrel design ❑ Dry top design with 0-ring sealed oil reservoir ❑ Traffic feature with stainless steel safety stem coupling ❑ Compression-type main valve closes with pressure for positive seal; it is made of rubber and is conveniently reversible providing a spare for long service life(Patent Pending) ❑ Operating nut available in wide variety of shapes and sizes---open left or right ❑ Field replaceable hose and pumper nozzles , ❑ Hose and pumper nozzles have large radius, full flow openings for low friction loss ❑ Contoured shoe is designed for full flow ❑ Dual bronze drain valves provide effective barrel drainage ❑ 250 psig(1723 kPa)maximum working pressure,500 prig(3447 kPa)static test pressure for 3-way hydrants; 200 psig(1379 kPa) maximum working pressure,400 psig(2758 kPa) static test pressure for 2-way and I-way hydrants i Dimensions � Non-rotating _ bolt design--- -i no tool need on back side -� \ of bolt for - - 7 Mechanical joint s n easier installation --standard and ,0-1/8"_4.6noe Front view detail o 0 D-150 6.7/32 -6 snoe of Mechanical Point 10-3/6•-6•s„°e (Standard only) ,e• I ( i —� — 12 (6'Shoe) ' \ VOW Flange LA Vertical i Bury-1'6'(0.46m) 10-7/e•-4•snoe �f Flange* — minimum;longer by 6' 9.3/4•-6•snoe s5-1 s1t l (162 mm)intervals. *4"Vertical shoe available for A-420 and A-421 hydrants. + Slip-on 3-7/16' 9-11/16' SEE PAGE 9.24 FOR ORDERING INSTRUCTIONS MUELLER° SUPER CENTURION° Mueller Co. 9M5 FIRE HYDRANT PARTS REV.4-99 MUELLER Super Centurion Fire Hydrant Parts Cat. Description Material Material standard A-1 part# — — — A-2 — — —A-1 Operating A-85 nut Bronze ASTM B584 A-3 A-2 Weather cap(not shown;used onlyon re-1988 models) Cast iron ASTM A 126 CL.B — — — A-3 Hold down nut 0-ring Rubber ASTM D2000 BUNA N A-4 A-4 Hold down nut(not shown;used only on pre-1988 Bronze ASTM B584 - A-84 models) A-5 A-5 Bonnet 0-ring Rubber ASTM D2000 BUNA N A-6 A-6 Anti-friction washer Celcon A-7 A-7 Oil plug Brass ASTM B16 A-8 A-8 Bonnet Cast iron ASTM A 126 CL.B A-9 A-9 Bonnet bolt and nut Steel ASTM A307 Plated A-10 A-10 Bonnet O-ring(1997 and newer 3- ,y models;all pre- Rubber ASTM D2000 BUNA N 1997 models and 1-wa and 2-wa models have Flat as A-1 1 ,a. A-11 Upper stem Steel ASTM A576 GR.B Jr A-12 A-12 Stem 0-ring Rubber ASTM D2000 BUNA N A-13 A-13 Nozzle lock Stainless steel ASTM A276 t I A-14 A-14 Pumper nozzle Bronze ASTM B584 A-15 t A-15 Pumper nozzle gasket Rubber ASTM D2000 Neoprene A-16 A-16 Pumper nozzle 0-ring Rubber ASTM D2000 BUNA N A-17 A-17 Pumper nozzle cap Cast iron ASTM A 126 CL.B A-18 A-18 Hose nozzle Bronze ASTM B584 t'll) A-19 A-19 Hose nozzle gasket Rubber I ASTM D2000 Neoprene l'T�� A-20 A-20 Hose nozzle 0-ring Rubber ASTM D2000 BUNA N A-21 A-21 Hose nozzle capCast iron ASTM A126 CL.B A-22 Cap chain Steel Plated A-22 A-23 Chain ring Steel Plated A-23 A-24 Upper barrel less nozzles Cast iron ASTM-A 126 CL.B A-24 A-25 Safety coupling Stainless steel ASTM A890 A-25 A-26 Safety flange bolt and nut Steel ASTM A307 Plated A-26 A-27 Safety flange 0-ring(1997 and newer models; Rubber Cellulose A-27 re-1997 models have flat asket� A-28 A-28 Safety flange Cast iron ASTM A[26 CL.B A-29 A-29 Cotter pin Stainless steel ASTM A276 I A-30 A-30 Clevis pin Stainless steel ASTM A276 A-31 A-31 Lower stem Steel ASTM A576 GR.B A-32 Lower barrel Cast iron ASTM A126 CL.B A-33 A-33 Stem in Stainless steel ASTM A276 A-34 Drain valve facing Plastic A-34 A-35 Drain valve screw Stainless steel ASTM A276 A-35 A-36 Upper valve plate(includes A-34 and A-35) Bronze ASTM B584 A-36 A-37 Shoe bolt and nut Steel ASTM A307 Plated A-37 A-38 Drain ring housing 0-ring 0 997 and newer models; Rubber ASTM D2000 BUNA N A-38 I t� re-1997 models Haves square asket) f'� /A-39 A-39 Seat ring to 0-ring Rubber ASTM D2000 BUNA N A-40 A-40 Drain ring housing Cast iron ASTM A 126 CL.B A-41 A-41 Drain ring housing bolt and nut(not shown; used only Steel ASTM A307 Plated - _ "" -. on re-1997 model-hydrants) ""A A-42 A-42 Drain ring Bronze ASTM B584 / C//� A-43 A-43 Seat ring Bronze ASTM B584 �`K� '�///� A-44 A-44 Seat ring bottom 0-ring Rubber ASTM D2000 BUNA N I A-45 A-45* Reversible main valve(1997 and newer models only; Rubber ASTM D2000 i A-46 pre-1997 models use non-reversible main valve and lower A-47 valve late-not shown) A-46 Lower valve plate(1997 and newer models for Cast iron ASTM A126 CL.B I A-48 reversible main valve;pre-1997 models have non-reversible main valve-not shown) A-49 A-47 Cap nut seal Rubber ASTM D2000 �--A-50 A-48 Lock washer Stainless steel ASTM A276 A-51 A-49 Lower valve plate nut Cast iron ASTM A 126 CL.B A-50 Shoe Cast iron ASTM A 126 CL.B A-84 Hold down nut Bronze ASTM B584 A-85 Weather seal Rubber ASTM D2000 A-51 10.5 oz.hydrant lubricating oil(not shown) *Pre-1997 models may be upgraded to use the reversible main valve by also replacing the lower valve plate with the 1997 model. SEE PAGE 9.24 FOR ORDERING INSTRUCTIONS 10.E Mueller [o. C-12" MUELLERO A-2360 RESILIENT WEDGE REV.4.99 _ GATE VALVES WITH M.J. x FL. ENDS ❑ Catalog number--- A-2360-16 mechanical joint x flanged ends(with mechanical joint unassembled accessories) A-2360-19 mechanical joint x flanged ends(less mechanical joint accessories) ❑ Sizes---4",6",8", 10", 12" _ ❑ Meets or exceeds all applicable requirements of ANSUAWWA C509 Standard and is certified to ANSI/NSF 61 ❑ Flanged end dimensions and drilling comply with ANSI B16.1,class 125 m, ❑ Mechanical joint end complies with ANSI/AWWA C 111 Standard ❑ Iron body with nominal 10 mils MUELLER@ Pro-GardTM Fusion Epoxy ` s Coated interior and exterior surfaces Res ;}aEr° ❑ Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF 61 . ❑ Iron wedge,symmetrical&fully encapsulated with molded rubber; no exposed iron " ❑ Non-rising stem(NRS) � w ❑ Triple 0-ring seal stuffing box(2 upper& 1 lower O-rings) ❑ 2"square wrench nut(optional handwheel available)---open left or open right ❑ 4"-12"sizes --250 psi g(1723 kPa)maximum working pressure, M.J.accessoriesshipped unassembled 500 psig(3447 kPa)static test pressure ❑ UL Listed,FM Approved---200 psig(1379 kPa) A-2360-16 Options See pages 10.68 and 10.69 for more information on Resilient Wedge Gate Valve options ❑ Position indicators ❑ Stainless steel fasteners:Type 304,Type 316 ❑ ASTM 1398-C66100/1­104 stem ❑ Handwheel Resilient wedge gate valve parts G-20 G-200 G-207 Catalog Description Material Material standard G-41 Part No. G'49 /G-201 G-16 Bonnet Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated Z1 / G-206 G-41 Stuffing Box Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated G-49 Stem O-rings(3) Rubber ASTM D2000 G-203 G-210" G-200 Wrench Nut Cap Screw Carbon Steel ASTM A307 Grade B,Zinc Plated G-201 Stuffing Box Seal Rubber ASTM D2000 G-16 G-202 Wrench Nut Cast Iron ASTM A126 CL.B G 211„ G-203 Stem Bronze ASTM B 138 G-206 G-204 Hand Wheel(not shown) Cast Iron ASTM A126 CL.B G-205 Stem Nut Bronze ASTM B62 G-212- G-206 Guide Cap Bearings Celcon G-207 Stuffing Box Cast iron ASTM A126 CL.B i G-208 Anti-friction Washers(2) Celcon G-209 'G_209 Wedge, G-206 Rubber Encapsulated Cast Iron* ASTM A126 CL.B G-210** Bonnet Cast Iron ASTM A126 CL.B G-211** I Bonnet 0-fing Rubber ASTM D2000 G-212** I Body Cast Iron ASTM A126 CL.B *Fully encapsulated in molded rubber with no iron exposed **Previous to 1999 these parts on 4%12"valves were designed with a gasket instead of an 0-ring and with additional bolts. Confirm the type of seal when ordering a replacement gasket or 0-ring. SEE PAGE 10.73 FOR ORDERING INSTRUCTIONS C-12" MUELLER" A-2360 RESILIENT WEDGE Mueller Co. 1 Om7 _ GATE VALVE DIMENSIONS - M.J. x FL. ENDS REV.4-99 AM FFF A 00 FF TT N M _ UU I L�I�YY----� Dimensions Dimension* Nominal size 411 C p 1011 1211 A 14.19 18.00 21.50 25.50 28.62 L 2.50 2.50 2.50 2.50 2.50 M 4.90 7.00 9.15 11.20 13.30 N 9.12 11.12 13.37 15.62 17.88 0(number and size of holes for MJ) 4---7/8" 6---7/8" 6---7/8" 8---7/8" 8---7/8" FF 4.30 6.30 8.30 10.30 12.30 00(bolt circle diameter for MJ) 7.50 9.50 11.75 14.00 16.25 Tr 9.00 11.00 13.50 16.00 19.00 UU(bolt circle diameter for FL) 7.50 9.50 11.75 14.25 17.00 YY 9.50 11.00 12.00 13.88 14.44 FFF(number and size of holes for FL) 8--3/4" 8---7/8" 8---7/8" 12---1 12---1 Turns too en 14 20.5 26.5 33 38.5 Weight* 1115 1 18 1275 400 570 *All dimensions are in inches. All weights include accessories and are in approximate pounds. 10A6 Mueller Co. 2"1 2-1/2" & 3" MUELLER° A-2360 RESILIENT REV.4-99 WEDGE GATE VALVES WITH THD. x THD. ENDS ❑ Catalog number--- A-2360-8 threaded ends ❑ Sizes---2",2-1/2", 3" , ❑ Meets or exceeds all applicable requirements of ANSI/AWWA F C509 Standard and is certified to ANSI/NSF 61 ❑ Thread end dimensions comply with ANSI 132.1 ❑ Iron body with nominal 10 mils MUELLER°Pro-GardTM Epoxy Fusion Coated interior and exterior surfaces ❑ Epoxy coating meets or exceeds all applicable requirements of ANSI/AWWA C550 Standard and is certified to ANSI/NSF 61 ❑ Iron wedge,symmetrical&fully encapsulated with molded rubber; no exposed iron ❑ Non-rising stem(NRS) ❑ Triple 0-ring seal stuffing box(2 upper& 1 lower 0-rings) ❑ 2" square wrench nut(optional handwheel available)---open left ory open right ❑ 2"-3"sizes---250 psig (1723 kPa)maximum working pressure, 500 psig(3447 kPa)static test pressure ❑ UL Listed,FM Approved: 200 psig(1379 kPa)--- 3" size A-2360-8 Options See pages 10.68 and 10.69 for more information on Resilient Wedge Gate Valve options ❑ Position indicators ❑ Stainless steel fasteners:Type 304,Type 316 ❑ ASTM B98-C66100/H04 stem ❑ Handwheel �i G-202 Resilient wedge gate valve parts G-200 G-207 41 Catalog Description Material Material standard G-4 f c 20, Part No. G-208 G-16 Bonnet Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated v � G41 Stuffing Box Bolts&Nuts Carbon Steel ASTM A307 Grade B,Zinc Plated G-203 G-49 Stem O-rings(3) Rubber ASTM D2000 G-210 G-200 Wrench Nut Cap Screw Carbon Steel ASTM A307 Grade B,Zinc Plated G-ts G-201 Stuffing Box Seal Rubber ASTM D2000 G-202 Wrench Nut Cast Iron ASTM A126 CL.B G-211 G-203 IStem Bronze ASTM B138 G-205 G-204 Hand Wheel(not shown) Cast Iron ASTM A126 CL.B ✓G 21F G-205 Stem Nut Bronze ASTM B62 G-206 Guide Cap Bearings Celcon G-207 Stuffing Box Cast iron ASTM A126 CL.B _ _ G-209 G-208 I Anti-friction Washers(2) Celcon G-206 G-209 Wedge, Cast Iron* ASTM A126 CL.B Rubber Encapsulated G-210 Bonnet Cast Iron ASTM A 126 CL.B G-211 Bonnet Gasket Rubber ASTM D2000 G-212 Body Cast Iron ASTM A 126 CL.B *Fully encapsulated in molded rubber with no iron exposed SEE PAGE 10.73 FOR ORDERING INSTRUCTIONS 2 12-1/2" & 311 MUELLER@ A-2360 RESILIENT Mueller Co. 1017 WEDGE GATE VALVE DIMENSIONS - THD. x THD■ REV.4-99 A H HT _ FF NPT I--- WW-1 V Dimensions Dimension* Nominal size 2" 2-1/2" 3" A 9.88 12.38 12.38 V 5.88 5.88 6.88 FF 2.30 2.80 3.30 HH(hex--across flats) 3.88 4.25 5.00 W W 4.12 4.12 5.12 Turns too en 8 11 11 Wei,-ht* 31 60 62 *All dimensions are in inches. All weights are in pounds and are approximate. The MainGuard hydrant is built better than any other oth hydrant in its class. The features available on this model include: ■ 21/z NST Nozzle.Also avail- able in any smaller size. ■ Traffic Break-away. The Main- Guard is designed to break easily at ground level. y ■ Security.A locking cover pre- vents water theft and protects MainGuard from the elements. A" ■ Easy Repair. You'll never need It a shovel to repair the Main- x �t Guard. Remove two bolts and you can take the inner workings out for easy repair and replacement. ■ Brass Working Parts.All the moving parts are enclosed and made from high quality brass for greater durability and wear. ■ Full Draining Capabilities. The MainGuard drains to prevent freezing after flushing. ■ 2"FIP Inlet. Inlet can come in from the side, or from the bottom. (As shown). ■ Underground Model Available. The *78 MainGuard blow-off hydrant can be placed in a meter box if an underground installation is desired. b MainGuard hydrants are '= recommended for water main flushing purposes only. Please see our Eclipse line of hydrants for all other applications. f 1-800-231 -3990 Model #78 MainGuard Model #77 0 MEMBER HE KUPFERIE f0WM(0_WW 013 HE PSTE.O STREET i ST.LOUIS MISSOUFI 60102 Flushing and Sampling Systems At the end of the main — ffs MainGuard Submittal Sheet for Crispin C Series r9 Manufactured in compliance with ANSI/AWWA C512 Date: October,2001 11 1 5 g A 15 2 10 13 ' 50 5 4 11 A� 4 7 2 =E!:I=rr-n 12 I s 7 g t rlfl—z 3 -'' 8 3 DIAMETER MAX.PRES. DISCHARGE RATE 65 1 1/8" 50 PSIG 9.6 SCFM 3/32" 85 PSIG 8.3 SCFM -- 29 J 1/16" 150 PSIG 6.1 SCFM A 3/64" 200 PSIG 4.5 SCFM 1/32" 300 PSIG 3.2 SCFM The combination air valve(s)shall be installed at high points in the system or MODEL INLET SIZE OUTLET SIZE A B WHT. at points selected by the engineer.This will permit discharging the surge of C5 1/2"NPT 1/2"NPT 8.75 5.75 air s from an empty line when filling and relieve the vacuum when draining,and also--*C10 1"NPT 1"NPT 10.25 6.00 13 21 ' to release an accumulation of air when the system is under pressure. ,y , The body of the valve shall be one integral casting or 2 valve bodies flange bolted together containing an air and vacuum valve and a separate pressure ITEM DESCRIPTION MATERIAL ASTM _ valve mechanism. is TOP CAST IRON A126 CL.B The Air and Vacuum Valve shall operate by sealing the BUNA-N rubber outlet 2 FLANGE CAST IRON A126 CL.B seat with a peripherially guided float as the liquid enters the valve chamber to 3 BODY CAST IRON A126 CL.B raise the float All Crispin Valves are hydrostatically tested at 150%of their 4 GASKET ARMSTRONG N-8092 N/A maximum working pressure. 5 SEAT BUNA-N RUBBER D2000 The pressure air release vaive shall operate through simple or compound 6S FLOAT STAINLESS STEEL A240 levers to permit air to be released under operating conditions.The valve shall 7 HANGER STAINLESS STEEL A240 have a "orifice with valve sealing faces of an adjustable 8 CUP STAINLESS STEEL A312 BUNA-N valve and (stainless steel or PVC) and shall operate at 9 RIVET STAINLESS STEEL A582 PSIG and be capable of passing SCFM of air. 9A FLOAT ROD STAINLESS STEEL A582 The valve(s)shall be CRISPIN Model Combination Air Valve, 11 BOLT STEEL A307 Type N,(PVC seat and BUNA-N rubber valve)or Type P(stainless steel seat 12 NUT STEEL A563 and BUNA-N rubber valve) pressure valve as manufactured by Crispin. 29 PLUG BRASS B505 Multiplex Manufacturing Co.,Berwick,Pa. 50 INTERFERENCE PIN STAINLESS STEEL A582 The valve(s)shall be "NPT screwed or ANSI Class(125,250) _ 5 ,', •- flanged inlet connection and shall be cast iron body, top, and inlet flange ITEM DESCRIPTION MATERIAL ASTM (where required),stainless steel floats with bronze and brass or stainless steel trim.Refer to Air&Vacuum and Pressure Air Release specifications for Valve 1 VALVE SEAT STAINLESS STEEL A240 description. 2 PLUNGER BUTTON VITON D2000 Option:A protectop shall be supplied to prevent debris from entering the out 4 VALVE LEVER STAINLESS STEEL A240 let of the Air and Vacuum Valve. 5 SCREW DRIVE STAINLESS STEEL A193 -- 6 BALL FLOAT STAINLESS STEEL A240 Option:(Where pressures are greater than 300 psig),the valve(s)shall be 7 HINGE PIN STAINLESS STEEL A580 ANSI Class flanged inlet connection and shall have a(steel,stainless steel,or 8 HINGE BUTT STAINLESS STEEL A240 ductile iron)body,top and inlet flange. 9 BOLT STEEL A307 Standard operating pressure for Crispin Air Valves is 20 to 150 PSIG. 10 SCREW STAINLESS STEEL A193 Please check one of the following if your operating needs differ: 11 FLANGE CAST IRON A126 CL.B 2 to 40 PSIG 151 to 300 PSIG 13 FLANGE GASKET ARMSTRONG N-8092 N/A C Crispin Valve,600 Fowler Ave.,Berwick,PA 18603.1-800-AIR-VALV"T.(570)7524524"F:(570)7524962" WWW.CRISPINVALVE.COM"sales@c6spinvalve.com RNP•January 1, 1999 ROMAC �C INCUSTRIES, "FTS420" Fabricated u 1-800-426-9341 A A Steel Tapping Sleeves CATALOG NUMBER SLEEVE NOMINAL O.D.RANGE SLEEVE BRANCH APPROX. PIPE SIZE (Inches) NUMBER BY SIZE WEIGHT (Ibs.) 6.83- 7.16 1 F7S420-7.16 3' 74# To Order: Specify catalog 6 it 7.05- 7.40 FTS420-7.40 X 4" 76# number by the desired O.D. range 7.40- 7.73 FTS420-7.73 6" 82# and flange size. Add S.S. for 7.74- 8.35 2 FTS420-8.35 3' 83# optional 304 stainless steel bolts „ 8.98- 9.37 1 FTS420-9.37 6" 88# p $ X75 & nuts, and F.E. for optional 8 to 9.27- 9.69 1 FTS420-9.69 8' 116# 12 mils of fusion bonded epoxy..*- 9'83- 10.25 2 FTS420-10.25 3' 90# 10 Oit 10.64 - 10.86 1 FTS420-10.86 4' 92# Example: 11.03 - 11.47 1 FTS420-11.47 X 6" 125# 11.36 - 11.80 1 FTS420-11.80 8" 125# FTS420- 17.87 x 6 - SSFE 11.76- 12.24 2 FTS420-12.24 10" 168# 3• 98# 1 For size on size taps, a 1/2" under- 1 G A 12.62- 12.88 1 FTS420-12.88 4" 100# sized shell cutter is required. 11 13.13- 13.60 1 FTS420-13.60 X 6" 104# 13.60- 14.09 FTS420-14.09 8" 140# 2 For size on size taps, 2" undersized 14.10- 14.56 FTS420-14.56 12" 192# shell cutter is required. 3" 102# Some ranges not listed are 14.59- 15.08 FTS420-15.08 4" 106# g 1 ^ 15.23- 15.80 FTS420-15.80 X 6' 112# available on request. 't 15.73- 16.22 FTS420-16.22 8- 151 # 16.30- 16.73 FTS420-16.73 10" 172# Test plugs furnished on all 12" 207# applicable models, and are 3" 112# stainless steel when tapping 16.74- 17.26 FTS420-17.26 4" 115# sleeve is ordered with S.S. bolts 1611 17.88- 18.43 FTS420-18.43 X 8" 162# and nuts. 18.62- 19.19 FTS420-19.19 10" 187# 12" 222# 3' 120# 18.87- 19.45 FTS420-19.45 4" 122# 19.41 - 20.01 FTS420-20.01 6" 126# 1 $ 20.00- 20.60 FTS420-20.60 X 8" 180# 20.29- 20.94 FTS420-20.94 10' 199# 20.93- 21.57 FTS420-21.57 12" 237# 21.51 - 22.15 FTS420-22.15 3" 130# 22.16- 22.81 FTS420-22.81 4" 133# 20 r 22.78- 23.45 FTS420-23.45 X 6' 140# 23.46- 24.16 FTS420-24.16 8" 185# 24.15- 24.85 FTS420-24.85 10" 218# 24.82- 25.52 FTS420-25.52 12" 255# 3" 143# 25.71 - 26.41 FTS420-26.41 4" 145# 2411 26.55- 27.25 FTS420-27.25 X 160# 27.26- 27.96 FTS420-27.96 8" 215# 28.14- 28.84 FTS420-28.84 10" 236# 12" 270# 3" 163# 29.78- 30.48 FTS420-30.48 4" 165# 30 30.48- 31.18 FTS420-31.18 X 6" 175# 31.52- 32.22 FTS420-32.22 8" 226# 10" 255# 12" 289# 4-13 RNP•January 1, 1999 ROMAC V INCUSTRIES, Style "501" Straight, Transition 6W 1-800.426-9341 MADE IN U.S7 and Long Barrel Couplings N Center Rings: Ductile iron per ASTM A 536, Grade 65-45-12.Yellow o shopcoat. Epoxy and special coatings available on request. A ROMAC ORIGINAL - 1970 +- The First Color Coded Ductile Iron Coupling cc End Rings: Ductile iron per ASTM A 536, Grade 65-45-12. Color coded c.) Interchangeable Gaskets and :.= RED for O.D. and Std. Stl., BLACK for cast iron and YELLOW for A/C. End Rings Reduce Inventory .Q Gaskets: Virgin SBR per ASTM D 2000 MBA 710,compounded for water and sewer service. Other compounds available on request. � Bolts and Nuts: Trackhead bolts, heavy hex nuts, UNC s/a" rolled NSF thread, high strength, low alloy, corrosion resistant steel per AWWA C111. w �. Other materials or special coatings available on request. cc Approved for Options: For other options and specifications, see Page 2-24. Most Sizes WARNING:Flexible couplings do not provide protection against possible pullout of pipe ends in unrestrained ' conditions.See Page 6-4 for appropriate restraint system. 6"501 CAUTION.Couplings with a step in the center ring have the potential for migrating along the pipe:therefore some Coupling ■ form of restraint should be used. NOM. ONE END BY OTHER END BY CTR. AppROX WEIGHT PIPE SIZE COLOR GASKET APPROX. X COLOR GASKET APPROX. X RING (Ibs.) TH CODE RANGE USE CODE RANGE USE 2n 2.00.2.13 O.D.Stl.,Copper X a' 2.00-2.13 O.D.Stl,Copper 5"1 9# 2.38-2.55 Std.Stl.,D.I.&PVC X 2.38-2.55 Std.Stl,D.I.&PVC L . .. ............................. L 3 rr 3.48-3.65 Std.Stl.&PVC ` 3.48-3.65 Std.Stl.&PVC 5"1 13# - B x •a�� x 3.65-3.82 3 C.I.&PVC 3.65-3.82 C.I.&PVC 10" 17# 722777727=�J rll�Z�111�11111 3.80-4.05 O.D.Stl.,3"D.I. 3.80.4.05 O.D.Stl. 5" 1 16# _ 4.06-4.31 Riv.Stl. 4.06-4.31 Riv.Stl. -� 4.50-4.70 Std,Stl. 4.50.4.70 Std.Stl. 7" 22# 4,� 4.50-4.81 Std.Stl.,D.I.&PVC X 4.50-4.81 Std.Stl.,D.I.&PVC X 4.80-5.00 Cast Iron&PVC 4.80-5.00 Cast Iron&PVC 10" 27# 4.74-5.10 C.I.&A/CME 4.74.5.10 C.I.&A/CME 12" 28# 5.11 -5.30 A/C R.B. 5.11 -5.30 A/C R,B. YELLOW 5.11 -5.40 A/C R.B.CL.200 YELLOW 5.11 -5.40 A/C R.B.CL.200 14" 36# 5.40-5.60 2 Std.Stl.&PVC 5.40-5.60 2 Std.Stl.&PVC 5.60-5.79 2 Std.Stl.&PVC 5.60-5.79 2 Std.Stl.&PVC 5.80-5.98 2 Std.Stl.&PVC 5.80-5.98 2 Std.Stl.&PVC 5" 1 23# o: 5.80-6.10 O.D.Stl. , 5.80-6.10 O.D.Stl. 6.05-6.30 Riv.Stl. 6.05-6.30 Riv.Stl. 7" 31 # 6" 6,55-6.76 Std.Stl.&PVC 6.55.6.76 Std.Stl.&PVC x µ . 6.60-6.91 Std.Stl.,D.I.&PVC X 6.60-6.91 Std.Stl.,D.I.&PVC 10" 37# 6.90-7.10 Cast Iron&PVC 6.90-7.10 Cast Iron&PVC 12" 45# 6.86-7.20 C.I.&A/CME 6.86-7.20 C.I.&A/CME 14" 53# 7.15-7.35 A/C R.B. 7.15.7.35 A/C R.B. YELLOW 7.26-7.60 A/C R.B.CL.200 ELLOW 7.26.7.60 A/C R.B.CL.200 777777777,172777, � 7.80 8.10 O.D.Stl. 7.80-8.10 O.D.Stl. 1 8.05-8.30 Riv.Stl. F 8.05-8.30 Riv.Stl. 5' 31 # 0 8.30-8.55 C.I-Soil,PVC Sewer ® 8.30-8.55 C.I-Soil,PVC Sewer 7„ 40# 8.55-8.75 Std.Stl. 8.55-8.75 Std.Stl.&PVC 8.60-9.06 Std.Stl.,D.I.&PVC X 8.60-9.06 Std.Stl.,D.I.&PVC X 10" 54# 9.05-9.30 Cast Iron&PVC 9.05-9.30 Cast Iron&PVC 8.99-9.40 C.I.&A/CME 8.99-9.40 C.I.&A/CME 12" 57# 9.31 -9.50 A/C R.B. 9.31 -9.50 A/C R.B. YELLOW 9.39-9.79 A/C R.B.CL.200 YELLOW 9.39.9.79 A/C R.B.CL,200 14" 67# 1 Standard Center Ring length. To Order:Determine O.D.of pipes to be coupled.Select proper gasket range for each pipe from above table. 2 Requires special 5"end ring. Insert high range of each gasket into catalog number as follows: 501 -one end x other end. 3 Not for use on Ductile Iron (3.96 OD) Example: To couple 4"A/C rough barrel and 4"O.D.steel,with 5"Center Ring,order 5 1-5.30 x 4.05 5 2-2 tilORTHTOWN COMPANY Pipe Protection Products POIYWRAP TUBULAR POLYETHYLENE PROTECTION FOR CAST IRON, DUCTILE IRON AND STEEL PIPE PRODUCT HISTORY Certain soils and artificial environments have been shown to be corrosive to cast iron pipe. In severe environments, the life of the pipe has been significantly shortened. Extensive tests and field installations for over 35 years have shown that loose polyethylene encasement of the pipe is an effective and economical means of corrosion protection. a PRODUCT USE / DESCRIPTION Polyethylene film prevents contact between the pipe and the surrounding soil for corrosion protection. However, it is not expected to be an airtight or watertight encasement. It is available in Natural (clear), Black or custom colors and in several widths suitable for all pipe sizes. INSTALLATION The 8 mil polyethylene tube should be cut to lengths that provide a one foot overlap beyond each end of a pipe section. Slip the tubing over the pipe and bunch it back to clear both ends. A shallow bell hole should be made to facilitate installation of the polyethylene. Lower the pipe into position and make up the joint. Pull tubing over the joint from the preceding pipe length and tape it securely to the new pipe length. Overlap the polyethylene from the new pipe length back over the same joint and tape in place on the preceding pipe barrel. Pull the polyethylene along the length of the new pipe, folding excess tubing over the top of the pipe barrel and securing it every 3 to 4 feet. Keep the excess polyethylene for the overlap of the next joint bunched back from the joint in preparation for making the next joint. Repeat this process for each new pipe length. Repair any tears, holes or other damage with tape or small sections of polyethylene taped into place. SPECIFICATIONS The 8 mil, Type 1, low density, flat tube, virgin polyethylene film provided, meets or exceeds the requirements of ANSI A21.5-93, AWWA C105-93,ASTM D1248-89, and NT4112-94. PROPERTIES Tensile Strength (psi) 1200 psi minimum Elongation 300% minimum Fungus Resistance - Federal Specification LS-137 and LS-125 Mildew Resistance -ASTM D-2020, Method A OPTIONS Northtown's Polywrap is available in custom colors and can be printed. A standard option is purple polywrap with the words "CAUTION RECLAIMED WATER LINE" printed lengthwise, continuously, and appearing four times around the circumference, equally spaced. As a custom product Northtown Polywrap may be manufactured at 10 mil thickness for limited pipe sizes. P. O. BOX 2064 • HUNTINGTON BEACH, CA 92647 (714) 375-4000 • FAX (714) 375-4006 StHVIL;t 1-11 1 IINGS WITH I Mueller Co 6n9 MUELLER 110@ COMPRESSION CONNECTION REV.4.99 Quarter bend coupling Straight three part union MUELLER 110®Conductive 1 ' MUELLER 110© Conductive " `f1 Compression Connection for Compression Connection for CTS O.D.* tubingx F.I.P. CTS O.D.* tubing---both ends thread H H-15533 -15403 1/T. 3/4" 1" 1"x3/4" 1-1/4" 1]-1/2" 2" 3/4" 1" 1-1/2" 2" coupling G �� � Eighth bend union = y Straight g DIM lert, MUELLER 110 Conductive r� MUELLER 110 Conductive � Compression Connection for Compression Connection for CTS O.D.* tubing x M CTS O.D. * tubing---both ends g .LP. thread H-15528 H-15428 1/2"$ 3/4" 3/4"xl" 1" 1 1'.x3/4" 1-I/4"xl" Q � ''`°' ., Quarter bend coupling Quarter bend union yow MUELLER 110 Conductive '` MUELLER 110 Conductive Compression Connection for Compression Connection for CTS O.D.* tubing ---both CTS O.D.* tubing x M.LP. ends thread H-15526 H-15531 1-1/2" 2" 3/4" 12" Straight coupling Straight coupling MUELLER 110 Conductive MUELLER 110 Conductive h A Compression Connection for Compression Connection for CTS` O.D.* x F.I.P.tubing �• CTS O.D.* tubing:x female thread copper flare thread H-15451 H-15071 3/4" 3/4"xl" 1" 1"x3/4" 1-1/4" 1-1/2" 2" 3/4" 3/4"xl" 1" 1-1/4" 1-1/2" 2" Eighth bend coupling �� Eighth bend coupling 4w MUELLER 110 Conductive MUELLER 110 Conductive Compression Connection for Compression Connection for } q P b; CTS O.D. * tubing x F.I.P. " CTS O.D. * tubing x swivel nut thread '" with female copper thread H H-15075 -15534 *See chart on page 6.11 for tubing and pipe that may be used with these connections. t Requires minimum ordering quantity.Contact MUELLER Customer Service Center for minimum ordering requirements and availability. [VOTE:Sizes shown above represent nominal size of fitting.When two sizes are given,first is size of MUELLER 110 Compression Connection and second is size of threaded end. MUELLER Service Fittings are manufactured and tested in accordance with ANSUAWWA C800. 8A.2 )Mueller ca.) COPPER METER YOKES WITH - ,REV.4-99' HORIZONTAL INLET AND OUTLET n i ti V k. at/ MUELLER 1100 Conductive Compression Connection ends Typical installation of a horizontal inlet and outlet copper meter (B-2470-2A05 with optional bracing eye shown) yoke Copper meter yokes with horizontal inlet and outlet, and Mueller 110 Conductive Compression Connection ends Catalog number H-1468 H-1469 H-1470 H-1471 B-2470 B-2471 Description Plain yoke With test valve With lock wing With lock wing With lock wing With lock wing ground key angle ground key angle MUELLER 3001m MUELLER 300 meter stop meter stop and test An-le Meter Ball Angle Ball Valve* valve Valve* and test valve Check valve options MUELLER Copper Meter Yokes can be ordered with one of the following: an ASSE approved top entry vertical check valve (except ; 5/8" yoke); an ASSE approved dual check valve; a dual check valve F ;` (ASSE non- approved). To order the ASSE approved top entry check feature, add a suffix of-6A to the y oke catalo e number; add -6D for the same check with a test drain. For the dual check feature, add a suffix of-2A to the yoke catalog number for the ASSE approved model or-2 suffix for the nonapproved model. Examples: M-98Tm ASSE approved top B2470-6D for the ASSE approved top entry vertical check with a test drain; Angle dual check valve entry vertical check valve B2470-2A for the ASSE approved model angle dual check valve. Dimensions Meter size 5/8" 5/8"x 3/4"* 3/411* E B Nominal size of I.P.thread in meter nut 3/4" V,_TA Dimension Dimension A I-1/16" 1-5/16" 1-5/16" Dimension B 7-7/8" 7-7/8" 9-3/8" F Dimension C-nominal pipe size of inlet and 3/4" 3/4" 3/4" outlet C Dimension D 6-11/16" 6-11/16" 8-1/8" Dimension E 12-5/8" 12-5/8" 14-1/4" Dimension F-minimum riser height 7" 7"(9"**) 8"(10"**) O - Other riser heights available 9" 12" 15", 18",21" 9" 12" 15", 18" 21" 12" 15", 18" 21" D 24",27",30",33",and 24",27",30",33",and 24",27",30",33",and 36" 36" 36" *Add"R"to the end of the yoke catalog number to order a reduced port Angle Ball Valve; EXAMPLE:5/8x3/4x7 B-2470R. **Minimum with 6A or 6D option. Copper Meter Yokes are normally supplied less end connections. See pages 8A.41 and 8A.42 for end connections that can be used with these yokes. Note:the 5/8",5/8"x 3/4"and 3/4"sizes are fumished with a tie bar on heights greater than 15". The 1"size is furnished with a tie bar on heights greater than 18". SPECIFY METER SIZE, RISER HEIGHT AND CATALOG NUMBER. 1/2" - 1 " GROUND KEY DESIGN (Mueller Co.l 5x7 CORPORATION VALVES REV.4-99 Ground Key Corporation Valve %` Ground Key Corporation Valve Inlet: AWWA taper(MUELLER Inlet: AWWA I.P. thread "CC") thread Outlet: MUELLERO 1100 Outlet: MUELLER" 110" Conductive Compression Conductive Compression Connection for CTS O.D. H-15008 Connection for CTS O.D. tubing* H-15028 tubing* 1/2"$ 3/4" A, 3/4"xl" 1" 1/2" 3/4" V. Ground Key Corporation Valve Ground Key Corporation Valve dF" Inlet: AWWA taper z= Inlet: AWWA I.P. thread y y (MUELLER "CC") thread . Outlet: MUELLER 110 Outlet: MUELLER 110 ' - Compression Connection for Compression Connection for IPS plastic pipe* H-15009 IPS plastic pipe* H-15029 3/4" l" 3/4" I" Ground Key Corporation Valve Ground Key Corporation Valve Inlet: AWWA taper Inlet: AWWA I.P. thread (MUELLER "CC") thread Outlet: MUELLER Pack Joint 1 f Outlet: MUELLER Pack Joint Connection for CTS O.D. Connection for CTS O.D. tubing* P-15008 tubing* P-15028 11 3/4" I" 3/4" I" Ground Key Corporation Valve Ground Key Corporation Valve 9 Inlet: AWWA I.P. thread Inlet: AWWA taper per Outlet: MUELLERO (MUELLER "CC") thread , ° Outlet: MUELLER" <'%"� INSTA-TITEO Connection for �> INSTA-TITE(D Connection for ` CTS PE plastic tubing* H-15006 CTS PE plastic tubing* H-15024 3/4" 3/4"x1"$ I" 3/4" 1" Ground Key Corporation Valve Ground Key Corporation Valve Inlet: AWWA taper `. � ; Inlet: AWWA I.P. thread (MUELLER "CC") thread Outlet: MUELLER Outlet: MUELLER INSTA-TITE Connection for INSTA-TITE Connection for H-15026 IPS PE plastic pipe* H-15005 IPS PE plastic pipe* 3/4" 3/4"x1"$ I" 3/4" 1„ *See chart on page 5.9 for tubing and pipe that may be used with these connections. #Requires minimum ordering quantity. Contact MUELLER Customer Service Center for minimum order requirements and availability. NOTE:Sizes shown above represent nominal size of inlet and outlet connections.When two sizes are given,the first is size of inlet and the second is size of outlet. For identification purposes MUELLER INSTA-TITE Connections for CTS O.D.PE plastic tubing have red gripper rings,and the connections for IPS PE pipe have white gripper rings. MUELLER® Corporation Stops and Valves are manufactured and tested in accordance with ANSI/AWWA C800. NO.65-R CAST IRON READING LID WT.- 7 7 1/2 DiA. 3 NO.65•TR STEEL TRAFFIC COVER 32 1/4 rya 205/g WT.-70 # c� s" x 67/8 �3/8 DIAMOND PLATE :a 7 I/g 11/4 131/2 N0.65 S LID 1 WT.-9# f I I GA. WELDED WIRE FRAMES 11/2 15 1/ NO.65•S COVER 267/8 4 \ , WT.—69 # I Ix 13/a o•:."°� N0. 65 S- BODY W/ CONCRETE 5/®3 /4 DIA.WELDED WIRE FRAME COVER a LID 3/ NO. 65•TR- BODY a STEEL COVER 1 W/ C.I. LID 32 I/4 205/8 NO. 65•T-BODY a STEEL COVER N0.65 BODY W/OUT LID ( NOT SHOWN) WT.- 165# NO. 65•S(C.I.)-BODY 81 CONCRETE 141/8 COVER W/ C. I. LID (NOT SHOWN) NO. 65•H- BODY a CONCRETE COVER W/ C.I. HINGED LID 253/4 ( NOT SHOWN12 ) 17 2 83/g \ + 11/2 1711 x 28" METER BOX ( FOR 2" WATER METER ) 4 <� 4 6 GA. WELDED WIRE FRAME REVISED DRAWING NUMBER N 165 SERIES BROOKS PRODUCTS INC . NO. 38•R - CAST IRON READING LID 71/2 DIA. W T.- 6# i 1/2 1/4 1/4 DIAMOND PLATE NO. 38•TR - STEEL TRAFFIC COVER t8 WT. - 37# F':� N0. 38 H COVER W / CAST IRON 27 1/2 HINGED LID WT.- 50# 11 GA. WELDED WIRE FRAMES 6 7/8 51/2 1 \ �\ 71/8 1 1/4 c(• \/ 131/2 r NO. 38•S LID WT. - 9# 11/2 1/4 DIA. WELDED 7 5/8 WIRE GRID NO. 38•S COVER 13 3/4 2 WT. - 45# / BRASS HINGE PIN /231/4 121/e a 2 3/4 .' 153/8 27 1/2 18 N0. 38 BODY NO. 38• S(C.I.) - BODY a CON- WT.-125# CRETE COVER W/C.I. LID NO. 38•H -BODY a CONCRETE COVER W/ C.I. HINGED LID 121/2 NO. 38•T -BODY a STEEL COVER W/OUT LID 12 22 . NO. 38•TR-BODY a STEEL COVER W/ C.1. LID 13 X 2 4" METER BOX 24 (FOR 11/2 WATER METER) 4 11/4 � REVISED DRAWING NUMBER 9 GA. WELDED 38 SERIES 41/4 WIRE FRAME BROOKS PRODUCTS INC.