HomeMy WebLinkAboutSWP272153 w 3 CITY OF RENTON PLANNINGBUILDING/PUBLIC WORKS MEMORANDUM DATE: January 15, 1996 TO: STORM WATER WASTEWATER FROM: Arneta H. X6198 SUBJECT: SAFEWAY FINAL PROJECT CLOSEOUT WOO RSTW 2153 C940106 4300 NE 4TH ST The purpose of this memo is to inform you that this project is done. Please refer to the attached two sheets for project information. cc: Neil W. MEMO.DOT/ IT PROJECT CHECKLIST Project No. R-2153 Project Name: SAFEWAY S-2153 W-2153 W.O.No. 87580 Address:4300 NE 4th St. Permit No. C940106 Date Issued: 8/4/94 Issued to:Safewa Preconstruction Meeting Sept. 13, 1994 Developer's Name Safeway Address Utility Contractor's Name: Abscher Construction Rich Teddy 845-9544 City Project Manager Arneta Henninger City Project Inspector Steve Pinkham Letter Special Billing Yes No May Comments: Original is attached to thi X be Final Inspection Signoff Date 6/19/95 As-Built Plan Checkprint Date:Yes Received As-buillt Plan sent to Date:12/8/ inspector 95 As-Built Plans Mylars Date:1/15/ Received 96 Easement Yes No N/A Sent to Carrie 12/29/95 X on Date Recording No. Bill of Sale sent to Carrie Date 12/29/95 Recording No. Cost-Data sent to Carrie Date 12/29/95 Backflow Test Reports Yes No N/A Date Received See Tom Fire Sprinkler DDCVA Domestic Water Meter Stub Service Agreement Yes No N/A Date Water Meters Size(inch) S.0 No. Domestic Meter 2" Landscape Meter 2" Fire Protection Meter Maintenance Bond to Dee Yes No N/A Expiration Date X _T AJH , r CITY OF RENTON MEMORANDUM DATE: December 30, 1994 TO: Lys H. Dave C. Bob M. Ron S. FROM: Arneta Plan Review X6198 SUBJECT: SAFEWAY NE 4TH & UNION RSW 2153 For your files. 0 REQUEST FOR FILE AND NUMBER El PRECON NOTICE 0 PRECON MINUTES 0 ATTENDEES AT PRECON 0 LETTER OF SPECIAL BILLING SIGNED 0 MEMO TO BECKY AND RAY STATING THAT LETTER OF SPECIAL BILLING WAS SIGNED 0 CONSTRUCTION PERMIT 0 RECEIPT FOR CONSTRUCTION PERMIT--SEE SIERRA SYSTEM UNDER PERMIT C940106 0 STORM DRAINAGE REPORT WAS TURNED OVER TO STORM AT THE BEGINNING OF THE PROJECT PC: Neil w. SPECIFY STORM OPTION: 1 Ll� S.C.S. TYPE-lA RAINFALL DISTRIBUTION ENTER: FREQ(YEAR) , DURATION(HOUR) , PRECIP(INCHES) 2,24,2.0 ---------------------------------------------------------------------- ******************** S.C.S. TYPE-IA DISTRIBUTION ******************** ********* 2-YEAR 24-HOUR STORM **** 2.00" TOTAL PRECIP. ********* ---------------------------------------------------------------------- ENTER: A(PERV) , CN(PERV) , A(IMPERV) , CN(IMPERV) , TC FOR BASIN NO. 1 8.07,85,0,0,24.7 DATA PRINT-OUT: AREA(ACRES) PERVIOUS IMPERVIOUS TC(MINUTES) A CN A CN 8. 1 8. 1 85.0 .0 .0 24.7 PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) 1 .01 7.83 23210 ENTER [d: ] [path]filename[ .ext] FOR STORAGE OF COMPUTED HYDROGRAPH: SPECIFY STORM OPTION: GN Z5 1 S.C.S. TYPE-IA RAINFALL DISTRIBUTION ENTER: FREQ(YEAR) , DURATION(HOUR) , PRECIP(INCHES) 10,24,3.4 ---------------------------------------------------------------------- ******************** S.C.S. TYPE-lA DISTRIBUTION ******************** ********* 10-YEAR 24-HOUR STORM **** 3.40" TOTAL PRECIP. ********* ---------------------------------------------------------------------- ENTER: A(PERV) , CN(PERV) , A(IMPERV) , CN(IMPERV) , TC FOR BASIN NO. 1 8.07,85,0,0,24.7 DATA PRINT-OUT: AREA(ACRES) PERVIOUS IMPERVIOUS TC(MINUTES) A CN A CN 8. 1 8. 1 85.0 .0 .0 24.7 PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) 2.94 7.83 56276 ENTER [d: ] [path]filename[ .ext] FOR STORAGE OF COMPUTED HYDROGRAPH: Led G z . 100,24,3.9 ---------------------------------------------------------------------- ******************** S.C.S. TYPE-lA DISTRIBUTION ******************** ********* 100-YEAR 24-HOUR STORM **** 3.90" TOTAL PRECIP. ********* ---------------------------------------------------------------------- ENTER: A(PERV) , CN(PERV) , A(IMPERV) , CN(IMPERV) , TC FOR BASIN NO. 1 8.07,89,0,0,24.7 DATA PRINT-OUT: AREA(ACRES) PERVIOUS IMPERVIOUS TC(MINUTES) A CN A CN 8. 1 8. 1 89.0 .0 .0 24.7 PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) 4.45 7.83 79488 ENTER [d:] [path]filename[ .ext] FOR STORAGE OF COMPUTED HYDROGRAPH: d:\rons\junk FILE ALREADY EXIST; OVERWRITE (Y or N) ? n ENTER [d: ] [path]filename[ .ext] FOR STORAGE OF COMPUTED HYDROGRAPH: (A-9 SPECIFY STORM OPTION: G�/ 1 S.C.S. TYPE-IA RAINFALL DISTRIBUTION ENTER: FREQ(YEAR) , DURATION(HOUR) , PRECIP(INCHES) 100,24,3.9 ---------------------------------------------------------------------- ******************** S.C.S. TYPE-lA DISTRIBUTION ******************** ********* 100-YEAR 24-HOUR STORM **** 3.90" TOTAL PRECIP. ********* ---------------------------------------------------------------------- ENTER: A(PERV) , CN(PERV) , A(IMPERV) , CN(IMPERV) , TC FOR BASIN NO. 1 8.07,85,0,0,24.7 DATA PRINT-OUT: AREA(ACRES) PERVIOUS IMPERVIOUS TC(MINUTES) A CN A CN 8. 1 8. 1 85.0 .0 .0 24.7 PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) 3.70 7.83 69094 ENTER [d: ] [path]filename[ .ext] FOR STORAGE OF COMPUTED HYDROGRAPH: Short Plat (S1'PL !! ) RE--QUEST FOR PROJECT!! Prclim. Plat (PP!! ) Cy 46 I o(o CAGR To: Technical Services Datc �� �9`�WQ!! GrccnM 1� From. Plan Review/Project Manager Project NameL� (70 characters max) Description of Project: '3p" /0 Circle Size of Wa"terline: 8" 10" 12" Circle One- Ne\v or Extension Circle Size of Sewerline: 101, 12 Circle One: Nety or Extension Circle Size of Stormline: 12" 15" 18" 24" Circle One: Nety or Extension Address or Street Name(s) � (J y �( Dvlpr/Contractor/Owner/Cnslt:s Q� (70 characters max) Check each discipline involved in Project Ltr Drwg #of sheets per discipline ✓ ✓ Trans-Storm _��� (RoadwaynXainage) (Off site improvementsXinclude basin name) (include TESC sheets) Q Transportation (Sigalization,Channelization,Ughting) or i Wastewater anitary Sewer Main)(include basin name) Water (Mains,Valves.Hydrants) bbb"' ' / ��� (include composite&Horizontal Ctrl Sheets) r— nn TS Use my / �� C�— / s 1 S ICJ C Approved by TSM Date: rorms/misc/92-090.DOC/CD/bh City of Renton Department of Planning/Building/Public Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: COMMENTS DUE: APPLICATION NO: LUA-93-948, SA, ECF DATE CIRCULATED: APPLICANT: Safeway, Inc./ Baylis Brand Wagner PROJECT MANAGER: Paul ForsandR'—_-N'Tr''" �17 DEPT. Architects FIRE FRLVLI i iulV 6UREAU ? PROJECT TITLE: New Safeway at NE 4th &Union Ave. WORK ORDER NO: 79706 DEC )� LOCATION: Approx 400 feet.east of NE 4th and Union,Intersection kP SITE AREA: 8.07 acres I BUILDING AREA(gross): SUMMARY OF PROPOSAL: Environmental Review and Site Plan Approval for development of approximately 78,800 gsf of retail space on an 8.07 acre site abutting the east side of the existing Safeway store. Three development phases are proposed: Phase I is a new 62,500 gsf grocery store and all site improvements; Phase II is 8,500 gsf of retail shops located between the existing grocery store and Phase I construction; Phase III is a free standing 7,800 gsf structure adjacent to NE 4th for either retail use or a fast food restaurant. This proposal also requires Binding Site Plan Approval. NOTE: This portion of the application along with Architectural Elevations will be submitted separately, prior to SEPA review. A. ENVIRONMENTAL IMPACT(e.g.Non-Code) COMMENTS � Element of the -Probable - Probable More Element of the Probable Probable More Environment Minor Major Information Environment Minor Major Information Impacts` Impacts Necessary Impacts Impacts Necessary Earth-;"' Housing Air' - Aesthetics Water -- Li htlGlare Plants Recreation LandIShoreline Use Utilities Animals Transportation Environmental Health Public Services Energy/ HistoriclCultural Natural Resources` - Preservation B. POLICY-RELATED COMMENTS C. CODE-RELATED COMMENTS �. ; We have reviewed this application with particular attenbon to those areas in which we have expertise and have identified areas of probable impact or areas where addition -information is ne ed to properly assess this proposal, nature of Di tafor Authorized Representative Date DEVAPP.DOC / Rev 10193 NARRATIVE FOR SAFEWAY AT 4TH & UNION - RENTON, WASHINGTON This proposal is for the development of an 8.07 acre site adjacent the northeast corner of 4th and Union in Renton, Washington. The proposal includes approximately 78,800 SF of retail space which will be developed in phases. Phase I will include a 62,500 SF Safeway grocery store and all site improvements. Phase II will include the adjacent 8,500 SF in-line retail shops. Phase III will include the 7,800 SF retail pad/fast food restaurant. The existing site is undeveloped with the exceptions of two structures which were abandoned years ago. The site is surrounded on the west by the existing Safeway store, gas station, and Taco Time restaurant; to the north and east is the Windsor Apartments; to the south, across the five-lane frontage road is undeveloped land and two-single family residences. The comprehensive plan shows this site designated as Community Center which allows for the proposed development. The underlying zoning is CB-Commercial as adopted in the Interim Zoning Code of June 7, 1993. The development of the site includes the removal of the abandoned residential improvements, and removal of overhead power and telephone lines currently bifurcating the site. Earthwork includes clearing and grubbing of the entire parcel and cutting, filling and importing as necessary to achieve workable grades for a retail ;development. Those grades to the northeastern corner of the site will be substantially lowered allowing the retail development to be recessed into the ground relative to the adjacent multi-family residential neighbors. Othersite improvements include underground sanitary,water, gas,telephone, electricity, storm water collection (including bio-filtration), paving, and landscaping. Additionally, surface improvements include a pedestrian connector from the frontage sidewalk connecting all retail facilities including a connection to the existing Safeway store on the adjacent westerly parcel. The proposed buildings are scaled to be appropriate for the commercial neighborhood and sited so as to not insult the multifamily neighbors. The exterior materials will be tilt-up concrete, block masonry and/or stucco-like finishes with metal and wood trims. Pedestrian walks along buildings will be covered by canopies and/or awnings constructed of fabric, metal and/or shingles. Colors will be light earth tones with bright accents. Signs will be displayed only on backgrounds designed for such purpose and will be consistent with governing ordinances of the City. CONSTRUCTION MITIGATION Refer to Questions A6, 131(h), 132(a), 132(c), 137(b), 1311(d), and Civil Drawings. RE'CEIVED DEVEiUFTAENT F BANNING CITY OF RENTON 2?99) = LA CON00_; � u 4.58 AC. T (4) u ` &4 SP.064-83 !j c Ij 2z9.59 ! j-J LtU I _"' 0.440 AC. 29 I 63 j 75 88 161.0� 274.01 Safewa New Safeway yn Ln r, Retail 1 "' 00 I II n .n N 1 N QJ SITE OFB6 �--� 0.25 AC. �.• PROPOSED DEVELOPMENT �z-LJ=Jb-Ij 8z 80 I50 2.84 Ac. I � Q I Q Q 20 .21 12 GL Retail Texaco Taco Time t.J I � erg; N.E.. 4 4T H S T I68.21. , 133.2 -160.03 i 323.42 /]23�._ __.. - o y I77tI 18795 ; fhf.l 430� I 80 lo0 1^ O I11 h 60 1 _-_ ---Z 1 �,M < 1 .o / o ~Z Ln 133a1 •I I NI _ `~-" z o . co �2 / o _ o ►<. (2) ♦ I r(j15 _— Z e ( o I 60 , 80.38 ZIZ6i Z73) S.F 1079069 ® !oz 3! ,O LIMIT m ' o3 8 0 0 4 1s3sz s' — SP.084- 323.SZ o3.s I I j1'A(fl 293 6SMY 'n / \ 12 18 303.674 3°_MY'*R I N S C R E T 2.4-5 - - --- ACTS . , z® Q l-so A c (293.831 324.oi 1923.C31 R 36 294.02 NTON(323.8 )-3Z4.02 317 02 316.83 U I�'s 35 128 —zl 1„ 323.8 .n "I 03.82T v S.P. 678160 =U N � Q R D E D SHOP I I __ - - - � 25d (-1 n Iw 1 ♦ •♦ _ 1 ♦ »� \ MW3 ♦♦♦♦ Location Map MW2 n. 150 1 — ♦♦ ' i ': ■_ ��,..rs'.' � ;. NE - dth ♦ i strsel � T 1 •r o o ,mm,-, 12 oh _. tr; � d.:•i ... ♦ ... - •-630 3'. - ~ rr' Hsi MWI v O ■ \ i ♦ - eftwoo r—� ^ - - - — r J • • 3.2 4 ism 0299 .■/_��.■ �- 3.4 • ♦ .�. .p • .. .y' • G 5 0 d.e F9 �o • � ♦6 S2'' ..... dz � 36 R'n�on \dJ _ • II 9R d.0 .6e_. 3.h �vll� 56 \ :� Rood O�flq 6.0 6.1 - 1 h° 02fl9 — ' �l — 6.4 _ o 1 7�o t _`\f 1 U t Maplewood & Orting Hills Subbasin Conditions Map 20 Cedar River Basin Planning Area i Stream&Stream Number '0/0 Problem Location/Area e Locally Significant Resource Area I Lake River Areawide Non point Water Flooding 0.6• Stream Mile Quality Problem I � 5 Wetland&Wetland Number � Wetland Habitat Problem j •�'• Subbasin Boundary 3 Stream Habitat Problem t 1 Catchment Boundary o IA 'AhMie MWl Catchment Number Erosion/Sedimentation