Loading...
HomeMy WebLinkAboutSWP272171(3) CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM DATE: August 27, 2003 TO: Bonnie Walton,City Clerk r7 FROM: Ron Straka, Surface Water Utility Supervisor(024$)' �L STAFF CONTACT: Raymond van der Roest,Civil Engineer II(x7392) SUBJECT: Wetland Mitigation Bank Site Fence Project—Bid Opening The Wetland Mitigation Bank Site Fence Project involves the construction of a chain link fence to protect the Wetland Mitigation Bank Sites along Oakesdale Ave SW. The bid opening for the subject project was held on Tuesday, August 19, 2003 at 2:30 PM. Two bids were submitted for the project. The bids were opened and officially read by the City Clerk. The engineer's estimate for this project is$45,623.34. The bids from Complete Landscaping, Inc. and L.W. Sundstrom, Inc have been reviewed for completeness, inclusion of all required forms,bid bond and mathematical correctness. Upon review of the two bids, the Surface Water Utility has determined that the both bids are unacceptable due to the following irregularities: one bidder did not complete the word section of the schedule of prices as required to qualify as a responsive, responsible bid; both bids included significant mathematical errors in completing the schedule of prices. The mathematical error consisted of the fact that the bidders did not properly multiply the estimated quantity by the unit cost correctly to establish the correct total cost for certain bid items. The mathematical errors would result in each of the total bid amounts for the two bids to be over five million dollars, if the unit prices were considered to be valid. Due to the irregularities in both bids,we recommend that all bids for the project be rejected. The Surface Water Utility intends to re-advertise the project for new bids in the future. Enclosed are the bid packages received from the two bidders. If you have any questions,please contact Raymond van der Roest or me. cc: Lys Hornsby H:\File Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\O1 Fence Proj 2003\1000 Correspond\A01_Drafts\clerkMEMO.doc\RJS\tb CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM DATE: June 18,2003 TO: Sandra Meyer,Transportation Division Leslie Betlach, Parks Department Abdoul Gafour, Water Utility David Christensen,Wastewater Utility John Thompson, PW Maintenance �/ FROM: Ron Straka, Surface Water Utilit,� 066— STAFF CONTACT: Raymond van der Roest(x7392) SUBJECT: Wetland Mitigation Bank Site Fence Project 90%Plan Review/Comments Attached is a set of 90% Design Plans for the Wetland Mitigation Bank Site Fence Project for your review and comments. Construction may occur between August and October 2003. The plans include installing approximately 2,300 linear feet of 6-foot high chain link fence with a barbed wire top. About two 20-foot wide gates and one 6-foot wide gate will be installed. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. Access to an existing water main, and apparently a buried telephone line, will need to be considered. Alternate B involves clearing more of the adjacent trees. The fence location will be selected after comments are received from the private utilities and other City Departments, and potential permitting issues are reviewed. Trees and shrubs along the fence line will need to be cleared. In the forest area the clearing will be about 5 feet on each side of the fence line. In non-forest area the clearing will be about 3 feet on each side. At the ends of the fence, thick sections of blackberry bushes will be preserved to discourage people from going around the fence to enter the property. Please review the Design Plans for utility conflicts and any other concerns that you may have. Please return your comments to me by June 27th. The Surface Water Utility will coordinate with you directly if you have any comments or questions. Please contact Raymond van der Roest at 425-430.7392 or e-mail, if you have any comments and/or questions. HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27 2171 Wetland Mitigation Bank\O1 Fence Proj 2003\1000 Correspond\030617 Util Memo.doc\Rv\tb Page 1 of 1 CITY OF RENTON Planning/Building/PublicWorks Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator June 18, 2003 Bill Gebenini TCI Cable of Washington 15241 Pacific Highway S. Seattle, WA 98188 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr. Gebenini: Enclosed is a copy of the project plans, in reduced format(I Ix17),for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, J, Raymond van der Roest,Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\O1 Fe 005 Corrsp-PrivateUtil\030617-TCI-Cable.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N AHEAD OF THE CURVE This paper contains 50%recycled material,30%post consumer • �� CITY OF RENTON Planning/Building/PublicWorks Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator June 18, 2003 Frank Forrest Qwest 7235 S. 228th St. Kent, WA 98032 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr. Forrest: Enclosed is a copy of the project plans, in reduced format(11xl7), for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3,2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, Raymond van der Roest, Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01� 005 Corrsp-PrivateUtil\030617-Qwest.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE 40 CITY OF RENTON gR PlanningBuilding/PublicWorks Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator June 18, 2003 Kathy Reed Olympic Pipeline 2319 Lind Ave. SW Renton, WA 98055 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Ms. Reed: Enclosed is a copy of the project plans, in reduced format(I Ix17), for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, Raymond van der Roest, Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\0� �-00 Corrsp-PrivateUtil\030617-Olympic Pipeline.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N O N 0 This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE CITY OF RENTON Planning/Building/PublicWorks Department Mayor Gregg Zimmerman P.E.,Administrator Jesse Tanner, June 18,2003 Jack Rucinsky Electric Lightwave 1218 Third Ave., Ste. 510 Seattle, WA 98101 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr. Rucinsky: Enclosed is a copy of the project plans, in reduced format(11x17),for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, r I Raymond van der Roest, Project Manager Surface Water Utility Enclosures H:\File Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01 F 005 Consp-PrivateUti I\030617-E1 ec-Lightwave.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE CITY OF RENTON .. Planning/Building/PublicWorks Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator June 18, 2003 Jeff McMeekin Puget Sound Energy P.O. Box 90868, XRD-01 W Bellevue, WA 98009 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr. McMeekin: Enclosed is a copy of the project plans, in reduced format(11x17), for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, r f" Raymond van der Roest, Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01 Fo, 005 Corrsp-PrivateUtil\030617-PSE.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N ®This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE 4,OR CITY OF RENTON M tt Planninouilding/PublicWorks Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator June 18, 2003 Doug Long ComCast 410 Valley Ave.NW#12 Puyallup, WA 98371 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr.Long: Enclosed is a copy of the project plans, in reduced format(1 lx17),for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the Southern Site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by July 3, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, Raymond van der Roest, Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\O1 F�' 005 Corrsp-PrivateUtil\030617-ComCast Cable.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N 9 This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE CITY OF RENTON a Planning/Building/PublicWorks Department ` Mayor Gregg Zimmerman P.E.,Administrator Jesse Tanner, July 24, 2003 Eric Davison King County Wastewater Treatment Division 201 S. Jackson St., KSC-NR- 0508 Seattle, WA 98104-3855 SUBJECT: CONSTRUCTION PROJECT - WETLAND MITIGATION BANK SITE FENCE PROJECT Dear Mr. Davison: Enclosed is a copy of the project plans, in reduced format(I Ix17), for installing about 2,300 linear feet of 6-foot high chain link fence on City owned property on the east and west sides of Oakesdale Ave SW. Construction may occur between August and October of 2003. At the southern site the fence will be installed in one of two possible locations. In Alternative A the fence is located about 12 feet off the face of the curb. In Alternative B the Fence is located about 28 feet off the face of the curb. The fence location will be selected after comments are received from the private utilities and other City of Renton Departments. We know two large diameter Metro sewers run along the northern site, but they have enough cover to facilitate the construction of a fence. A 20-foot wide gate will provide access behind the fence. Please review the plans and proposed fence locations, and identify any buried utilities that your company has in the area that could conflict with the project. If there are potential conflicts, please mark the locations on our plans in redline, provide us with a copy of any plans you have of your buried utilities in the area, and return both sets of plans to us. We would like to have your response by August 4, 2003, so we can finalize the drawings and advertise the project for bids. Please call me at(425)430-7392 if you have any questions. Sincerely, Raymond van der/oest,Project Manager Surface Water Utility Enclosures HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01�F 01 Corrsp-PrivateUtil\030617-Metro-sewer.doc\Rv\tb 1055 South Grady Way-Renton,Washington 98055 R E N T O N ®This paper contains 50%recycled material,30%post consumer AHEAD OF THE CURVE A CITY OF RENTON COUNCIL AGENDA BILL Al#: Submitting Data: Planning/Building/Public Works For Agenda of- Dept/Div/Board.. Surface Water Utility 12/15/03 Staff Contact...... Ron Straka, x-7248 Agenda Status Raymond van der Roest, x-7392 Consent.............. X Subject: Public Hearing.. Wetland Mitigation Bank Site Fence Construction Correspondence.. Project Funding Ordinance............. Resolution............ Old Business........ Exhibits: New Business....... Issue Paper Study Sessions...... Vicinity Map Information......... Recommended Action: Approvals: Council Concur Legal Dept......... Finance Dept...... X Other............... Fiscal Impact: Expenditure Required... Transfer/Amendment....... $30,000 Amount Budgeted....... $45,000 Revenue Generated......... Total Project Budget $75,000 City Share Total Project.. SUMMARY OF ACTION: The Surface Water Utility requests Council approval to transfer$30,000 from the completed Morris Ave. S. Storm Improvement Project account to the Wetland Mitigation Bank Site Fence Construction Project account. We intend to carry the transferred funds forward into 2004 to complete the fence project. The Morris Ave. S. Storm Improvement Project is complete and the remaining funds in the account are approximately $34,000. The chain link fences are needed to prevent the reoccurrence of vandalism, dumping of garbage, and environmental degradation caused by sport-utility vehicles four-wheeling on the sites. The project will reduce the need for City services for site clean-up as well as police and code enforcement responses to illegal activities. STAFF RECOMMENDATION: The Planning/Building/Public Works Department recommends Council approval to transfer$30,000 from the completed Morris Ave. S. Storm Improvement Project account (account# 421.600.018.5960.0038.65.065435) to the Wetland Mitigation Bank Site Fence Project(account# 421.600.018.5960.0038.65.065119) to provide sufficient funding for the project construction. H:\File Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01 Fence Proj 2003\I000 Correspond\City- 2003 Fund_Transt\031201_Agnbill.doc\Rv\tb CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM DATE: December 8, 2003 TO: Kathy Keolker-Wheeler, Council President Members of the Renton City Council VIA: Mayor Jesse Tanner ' FROM: Gregg Zimmerman' Administrator STAFF CONTACT: Ron Straka, Supervisor, Surface Water Utility Supervisor (X-7248) Raymond van der Roest, Project Manager(X-7392) SUBJECT: WETLAND MITIGATION BANK SITE FENCE CONSTRUCTION PROJECT FUNDING ISSUE: Additional funding is needed to complete the Wetland Mitigation Bank Site Fence Project. Surface Water Utility requests approval from Council to transfer funds in our budget and carry these funds forward into 2004 for the completion of this fence project. RECOMMENDATION: The Planning/Building/Public Works Department recommends Council approval to transfer $30,000 from the completed Morris Ave. S. Storm Improvement Project account (account# 421.600.018.5960.0038.65.065435) to the Wetland Mitigation Bank Site Fence Project (account #421.600.018.5960.0038.65.065119) to provide sufficient funding for the project construction. BACKGROUND SUMMARY: The Wetland Mitigation Bank Site Fence Project will place chain link fences to protect the two Wetland Mitigation Bank Sites along Oakesdale Ave. South(see attached Project Vicinity map). The chain link fences are needed to prevent the reoccurrence of vandalism, dumping of garbage, and environmental degradation caused by sport-utility vehicles four-wheeling on the sites. The project will reduce the need for City services for site clean-up as well as reduce police and code enforcement responses to illegal activities. The sites were donated to the City for the creation of a wetland bank and are zoned for resource conservation. The illegal dumping of garbage and the off-road vehicle use has required extra code and law enforcement services, in addition to the costs associated with Public Works Maintenance Services cleaning up the garbage dumped on the sites. This project will reduce the need for these services and the associated costs to the public. The Surface Water Utility had initially planned to construct the Wetland Mitigation Bank Fence Project in 2003. The construction contract was advertised last August and bids were opened. HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01 Fence Proj 2003\1000 Correspond\C ity-2003Fund_Transfl031201_IssuePaper.doc\Rv\tb December 8,2003 Page 2 Unfortunately, we had to reject the only two bids received due to irregularities in both bids. From the apparent intent of the bids we deduced that the real cost of construction will be higher than we had estimated. In addition, the staff costs to produce the construction plans and specifications, and advertise the project for bid was more than originally estimated. The additional funding is also needed for staff costs associated with the re-advertisement of the construction contract, and project management during the project construction. The 2003 project budget was $45,000. Year-to-date expenditures on the project are $9,474. The remaining project budget is $35,526. The revised estimated construction cost for the 2,300 linear feet of fence and other improvements is approximately $55,000. The requested funding transfer of$30,000, plus the remaining budget of$35,526, would provide for a total project budget of $65526, which would be carried forward into 2004. The total project budget will fund the construction and project management necessary for completion of the project. The Wetland Mitigation Bank Site Fence Project will be re-bid in early 2004. The Morris Ave. S. Storm Improvement Project was part of an interlocal agreement with King County. The City of Renton worked with King County to make water and storm utility improvements in Morris Avenue as part of King County's Eastside Interceptor Sanitary Sewer Capacity Restoration Project. The Surface Water Utility has paid King County in full for their work, and approximately $34,000 remains in the account. CONCLUSION: The Surface Water Utility recommends the transfer of$30,000 from excess funds from the completed Morris Ave. S. Storm Improvement Project to the Wetland Mitigation Bank Site Fence Project for its completion in 2004. The completion of the Wetland Mitigation Bank Site Fence Project will help protect the sites from environmental damage and reduce City service requirements from our code enforcement officers, our police, and Public Works Maintenance Services Division. cc: Lys Hornsby H:\File Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\01 Fence Proj 2003\1000 2 Correspond\City-2003 Fund_Transf\031201_IssuePaper.doc\Rv\tb VICINITY MAP F Wetland Mitigation Bank Site Fence Project I SW 16th St 1 \ sW 16th� St.� d � - S 19th 6 sW 21st St. SW 23rd Sttx W SW 27th St. SW 27th St. I SW 21 St F a [t Oth St. E•:. -��, SIT y FENCE LsW 3 th St. Uth S 1 f LOCATION _ I SO_ ElUsV / w t 4 St. SW 41st 0 1000 2000 1 : 12000 a EXEMPTION FROM SHORELINE MANAGEMENT ACT SUBSTANTIAL DEVELOPMENT PERMIT REQUIREMENT July 17, 2003 EXEMPTION FILE NUMBER: LUA-03-068-SME APPLICANT: City of Renton, Surface Water Utility 1055 South Grady Way Renton, Washington 98055 PROJECT NAME: Wetland Mitigation Bank Fence PROPOSAL: Construction of a 6-foot tall chain link fence around a wetland mitigation bank site to protect the wetland(s)from decline. The total length of fence is 2,300 feet; approximately 205 feet of fence are within the 200-foot setback of Spring Brook Creek. The closest area of work is approximately 47 feet from the ordinary high water mark of Spring Brook Creek. PROJECT LOCATION: Oakesdale Ave SW between SW 41st Stand SW 27th St SEC-TWN-R: Section 24/25 Township 23 Range 4 WATER BODY/WETLAND: Spring Brook Creek CORPS PUBLIC NOTICE NUMBER: NA An exemption from a Shoreline Management Substantial Development Permit is hereby granted on the proposed project described on the attached form for the following reason(s): x Watershed restoration project. The proposed development is consistent or inconsistent with (check one): CONSISTENT INCONSISTENT x Policies of the Shoreline Management Act. x The Master Program. 4 U)ay, Neil Watts, Director Development Service Division To appeal this determination, a written appeal--accompanied by the required $75.00 filing fee--must be filed with the City's Hearing Examiner (1055 South Grady Way, Renton, WA 98055, 425-430-6515) no more than 14 days from the date of this decision. Your submittal should explain the basis for the appeal. Section 4-8-110 of the Renton Municipal code provides further information on the appeal process. attachments: Vicinity Map Site Plan \ ` 1.960 a - -APPROX. TREE LINE, WETLAND BOUNDARY. CAI \\ - "WETLAND I - - - - - - - - - - - WETLAND - - - - - - - - - - - f' APPROX. TREE LINE S, - - - - - - - 06INARY HIGH WATER MARK, I - - - - - - - - - - - - - - +.✓ `� / TYPICAL APPROXj 1 \ TYPICAL TREE LINE, \ TREES: 24"" TO 6" DIAM.; - - - - - - - - - z - - FT,, MA FENCE CORNER. '/ ! 0 ... - TQ 70 FT. HEIGHT, \ LAC NEW CORNER POST 6' - \ z FROId EXISTING CORNER POST \ NEW CHAIN-LINK FENCE - - - - - - - - - - - - - - - - - j TYP., SEE DETAIL IN ENCE OPTION „B�� ;' O�O p0 No\LFJ1R BLACK \ PERTY c ER SPECIAL PROVISIONS - - - -CLEARING -AREA "A"=350 LF = - - - - - - - - P �` BERRIES e��� f 20 F/ANGLE OUBLE GATE �'/ - - �S THE - - - - - - /� ti& DENSE BLACK BERRIES 10' LIT. ESMT. CTR. 110' SOUTH TREE AT 24' OFF FOC / 20' SEE-NOTE FROM POST, TEL UNE - - - �"FOC T6 TREE DIRT ROAD SEE . DETAIL - 27�' FOC TO-*TREE - = = \\ ' TYP / 10' UT. ESWT. f7 --T SEE NOTE i — —T— 12.0' m Wv —7 —T- - END 12.0' FOC TO FENCE CB FACE OF CURB e %WV " op,nON A' 17.O' FOC TO ROW 17.0' FOG TO ROW FACE OF CURB 17' C � OAKESDALE AVE SW ROPERTY CORNER 28.0' FOC TO FENCE 90.0' ROW 56• CATCH BASIN, LIGHT POLE) I 28.0' 3 OPTION 'B' FENCE OPTION "A" SEE NOTE 3, TYP• TYPICAL j z FACE OF CURB 20 FT. DOUBLE GATE CU TRANS( NS FACE OF CURB SEE DETAIL DRAWING T012T10' HEIGHT TO THf SOUTH 1 NOTES: 1. 10' UTILITY ESMT. TO CITY OF RENTON, REC. NO. 8202080435 CALL 48 HOURS BEFORE YOU DIG & TO PUGET SOUND POWER do LIGHT CO., REC. NO. 8306240522 1-810-424-5555 2. ALL CLEARED AND DISTURBED AREAS SHALL BE HYDRO-SEEDED AFTER CONSTRUCTION IS COMPLETED. 3. TEMPORARY FILTER FABRIC CATCH BASIN RN PROTECTION PER 1990 KCSWDM. ITE74. CLEARING LIMITS: AREA 'A'; 10 FT WIDE, MEN CENTERED ON FENCE, ALL OTHER AREAS; NORTHERN 6 FT i NEEDED O CONSTRUCT THE FEN RED ON FENCE, OR CE. E. g 1'=40' CITY OF WETLAND MITIGATION BANK 77-11-200 RENTON FENCE PROJECT SOUTHERN SITE LOCATION FIGURE owc _ Planning/8ulding/Public Works Dept. �• c NO_ REVISION BY DATE APPR `� 1 —2 DF-[2:fl 1711111 cV f` N TENSION BAR, TYP_, >d I ATTACHED TO POST WfTH �( 3 STRANDS OF TENSION BANDS BARBED WARE �� CAP WITH SUPPORT TOP RAIL ARM FOR BARBED WIRE CHAIN-UNK 0 80' 160' _ FABRIC MIDDLE 1:960 6' E RAIL LINE POST TENSION POST LINE POST 10' OC. TYPICAL--] CHAIN-LINK FENCE DETAIL —ROW ...u.. TAU / _ 1J FACE OF CURB ---- •—._—..—.— — •—.--- -- OAKESDALE AVE SW CATCH BASIN 80.0, " 5:.0' noraaxt SEE NOTE 3., TYPICAL SAN SEWER LID. _ 15.0' 7.4 ROW » / lIT11Y METRO SEWER TYPICAL 72"0ET s_ METRO SEWER ­A�FACE-DE ,16•.-.-.-- CB,� U VAUL- 72" METRO SEWER - — WALK F OF U 36.5. 20.0' calc wWALK r o8'0 M RO S wit ~^ —� 21.0' \ /� ' 47.0' ��.__—.__�,�_� O\ do o v o 0 0 0 0 0 0 0 0 0 0 0 o v o 0 0 0 0 0 0 0 0 0 0 o ROW FENCE ANGLE PT 21.0' 20.0' U _- __ v o 0 0 o v o 0 0 0 0 O'15.0' - _LOC/�TED !�T LIGt{T �- o 2r o _ � 1 6' WIDE GATE l POLE EXISTING LINE OF ECOLOGY OBSERVED WETLAND• SED FENCE LINE 3 TO 4' BOUI D€RS AND �_ _ _ DETAIL— 1 wuT_ SOUNpARY do - - - - - -SET TWO FENCE ANGLE BLOCKS, FACE OF BLOC �00ww BARR11 ,_ TO BE \ ;i� WETLAND BOUNDARY, LIGHT POLE JUNCTION GRADE—BREAK GRADE BREAK IN FENCE POINTS AT 10' APART T IS ABOUT 36' OFF F MOVED INME FENCE LINE _ _ TYPICAL X.JN CQN PAD, TYP. _ _ _ LJNE, ABOUT_3 FEEET _ _ - GLEAR-POWER VAULTS - - - f' � /�' - - SEE NOTE I.; VERTICAL IN 9 FEET \ i SAN. SEINER UD �� _ HORIZONTAL I - 20 FT. DOUBLE GATE Ski _ \ _ _ _ _ INOF; CLE�,RING pF _ DO,NOT�IFAR BLYQND END ' DETAIL, LOCATE Af EX{ST. - JUNCTION BOX, TYP. AND YOUNG TREES MAY B - POST. i TYPICALWAND BOUNDARY. - DI/ROAD '' _ - _ NEEDED. TYPICAL • - I - MOVE 2-,IfCOLOGY BLOCKS - - - - WETLAN D TO PR0>4DE 20' ENTRANCE WETLAND - - - ' - - - - - _ - . . . - - - - - - - ' - - - - - - - W - - - - - - - - - - - - - - - - - - - - NOTES: CALL 48 HOURS BEFORE YOU DIG 1. VACANT 1—800-424-5555 2. ALL CLEARED AND DISTURBED AREAS SHALL BE HYDRO—SEEDED AFTER CONSTRUCTION IS COMPLETED. 3. TEMPORARY FILTER FABRIC CATCH BASIN PROTECTION PER 1990 KCSWDM. 4. CLEARING LIMITS: AREA Ate; 10 FT WIDE, CENTERED ON FENCE, ALL OTHER AREAS; TTE� 6 FT CENTERED ON FENCE, OR AS NEEDED TO CONSTRUCT THE FENCE. NORTHERN) AU SITE ,."s. CITY OF WETLAND MITIGATION BANK 07-11—zoo RDR ' R PENTON FENCE PROJECT RDR I� NORTHERN SITE �p1YC Plonning/Building/Public Works Dept. LOCATION FIGUREvm` NO. REVISION 2 -2 - 2171 2 D 0-3 CITY CITY OF RENTON E X E M Pq ��rz � 3 h FROM CRITICAL AREAS REGULATIONS DATE: July 17, 2003 PROJECT NAME: Wetland Mitigation Bank Fence OWNER/APPLICANT: City of Renton, Surface Water Utility PROJECT MANAGER: Kristina Catlin, Assistant Planner PROJECT LOCATION: Oakesdale Ave SW between SW 41st St and SW 27th St PROPOSAL: The applicant will construct a 6-foot tall chain link fence around wetland mitigation bank site to protect the wetland(s) from decline and preserve the integrity of the soil, water and vegetation. The total length of fence is 2,300 feet. CRITICAL AREA: The subject site is located in or near an unclassified regulated. EXEMPTION JUSTIFICATION: Pursuant to RMC section 4-3-050.C.5.h.1, of the Critical Areas Regulations is hereby granted for the following reason(s): X Natural Resource/Habitat Conservation or Preservation: Conservation or preservation of soil, water, vegetation, fish and other wildlife DECISION: The proposed development is consistent with the following findings pursuant to RMC section 4-3-050.C.4.c: 1. The activity is not prohibited by the RMC or state or federal law or regulation; 2. The activity will be conducted using best management practices as specified by industry standards or applicable Federal agencies or scientific principles; and, 3. Impacts are minimized and, where applicable, disturbed areas are immediately restored to their original state. SIGNATURE: 7/7�� Neil Watts, Director Date Development Services Division Director H:\Division.s\Develop.ser\Dev&plan.ing\kmc\Shoreline Exemptions\Wetland bank fence CAO.doc Page 1 of 1 Project; LUA.03-068 Location'OA.KESDALE AVE SW BETWEEN SW 41ST t S"Y 27 Status: PPROVED A! APPLICANT, CITY OF RENTON Date: 07/17/ 3 ea k!top Lj (� Srrcen ees ��T E'" Patce'i Status: ,PPROVED Zoning:RC — I Owner, CITY OFRENTON ProjectTi V,ULAhdDNIITIGATIONDANKFENCE R Address: up Code:TS3 055 Location OAKESDALE AVE SW BETWEEN SW 41ST& 27 Corrrprel-enme Plan Designation EAV Recontdetatlon'Y,M Assoriated Land UseActions�]SHORELINE EXEMPTION E)JenzionY/N:F Application Date' 07/17/2003 Wetlands Y/N r A.ccrptance+Not atonlRoutrg 07/17/2003 MortitofingDate: Publication/Postoi%/StateAgency: i/_ ERCDate' 1 End of Appeal Date: 07/31/2003 Appeals Filed rY/NJ Public Heating(YIN}.I— Adminiviabve Decision[YIN) File Sent to HEX tYIN),I- Date File Sent I_/ Heanng Exarrmet Dates=I_: HEX Decision Dates End Appeal Pwiod_/_I_ Appeals FiledY/N (— PiotectDecisionDate 07/17/2003 ProjectExpirationDate: 107A7120M Reserved Licensee:Renton,lntA•Cry ON Serial Number,6098 Users:025 ;Version Y.4.7.50 i ;Start �'PERPUTS'Plus { J_j , 4 l 2:27 PM CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM DATE: June 18, 2003 TO: Jennifer Henning, Development Services FROM: Ron Straka, Surface Water Utility(x-7248) SUBJECT: Letter of Exemption for fences at Wetland Mitigation Bank sites We are proposing to construct a fence along the Oakesdale Avenue SW street frontages of the city's Wetland Mitigation Bank sites. Our main objective in proposing these fences is to protect two wetland sites from continued intrusions by four-wheel drive vehicles and from illegal dumping. Please refer to the attached project narrative. Trees to be removed: On the northern Wetland Mitigation Bank Site property, the fence is located so that no trees need to be removed, except for some young 2"trees. On the southern Wetland Mitigation Bank Site property, the trees to be removed depend upon which fence alignment option is selected. The eastern right-of-way line of Oakesdale Ave SW is 17 ft. from the existing curb along the eastern side of the street. If the fence is constructed at an offset of 12 ft. from the curb(5 ft. inside the right-of-way), then no trees will need to be removed (Option "A"). If the fence were constructed at an offset of 28 ft. from the curb (11 ft. outside of the right-of-way), then 5 to 10 trees over 8" may need to be removed (Option `B"). We have enclosed the plan sheets, which show the fence locations. The two fence locations that are being considered for the southern site were based on avoiding conflicts with existing utilities and attempting to minimize vegetation removal. Letter of Exemption: The purpose of constructing the fence is to protect the wetland mitigation sites from further degradation, and to preserve and protect these wetlands, and that is in precise accordance with the purposes of the wetland regulations per RMC 4-3-050B-7, p. 3-11. Therefore,we are requesting that you grant a letter of exemption per RMC 4-3-050C-4. We believe that the proposed fence falls under the intended meaning of the exempt activities for wetlands, listed under RMC 4-3- 050C-5.a.i, 5.e.ii, 5.e.iii, 5.e.v and 5.f.ii. We believe the fence construction should be granted a shoreline permit exemption for the following reasons: Approximately 205-feet of the fence would be constructed within the 200-ft. shoreline setback from the ordinary high water mark of Springbrook Creek. The estimated cost to construct the 205 ft. feet of the fence that is located within the 200-ft. shoreline setback is$3,485,which is more than the cost exemption allowed in the city's shoreline master program ($2,500). However, HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27 2171 Wetland Mitigation Bank\01 Fence Proj 2003\1000 Correspond\City\City Permit Exemption.doc\RJS\tb June 18, 2003 Page 2 the cost is less than the new cost exemption that was recently approved by the State Legislature of $5,000. In addition,the construction of the fence qualifies for the normal maintenance exemption allowed by the city's shoreline regulations(4-9-190), since it is intended to prevent a decline in the condition of the Wetland Mitigation Bank Sites. By no means would the construction of the fence have as much of an impact on the shoreline as the construction of a normal protective bulkhead associated with a single family residence,which per city code is also exempt from having to get a shoreline permit. Please determine whether these or other exemptions apply or if we need to apply for any specific permits. If any permits are required please specify them. If you have any questions or need additional information, please contact Raymond van der Roest at x-7392 or me. Thank you. cc: Neil Watts Lys Hornsby H:\File Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27-2171 Wetland Mitigation Bank\OI Fence Proj 2003\1000 Correspond\City\City PermitExemption.doc\RJS\tb CITY OF RENTON Wetland Mitigation Bank Site Fence Project PROJECT NARRATIVE The proposed project consists of installing a 6 feet high chain-link fence at two locations along the right-of-way of Oakesdale Ave SW between SW 41st St. and SW 27th St. along the street frontages associated with the city's"wetland mitigation bank"sites. The total length of fence to be constructed is approximately 2300 ft. We anticipate that the only permits needed for the project is a Shoreline Exemption and a Certificate of Exemption from Critical Area Regulations. Both sites are zoned Resource Conservation(RC). The adjacent properties are zoned Industrial— light to medium, commercial office,and the southern site is bordered on the east by the Springbrook Creek Greenbelt. The distance from the closest area of work to the ordinary high water mark of Spring Brook Creek is 47 ft. The nature of the shoreline of Springbrook Creek is moderately steep(>25°), grassed banks of 10 to 20 ft. in height,with intermittent growth of trees and shrubs. The current state of the sites is undeveloped and that will remain until the sites are developed as official wetland mitigation banks. The purpose of both sites is to create a large protected wetland area that developers,who are required to perform on-site wetland mitigation, pay to replace their wetland mitigation in the bank site in lieu of providing on-site wetland mitigation. The existing improvements on the northern site include the following: 108 in. diameter Metro sewer, 8 in. diameter city sewer, and a gas stub line. The existing improvements on the southern property consist of an 8 in. city sanitary sewer. Both sites may contain small, low quality, isolated wetlands. The southern site near SW 4ft St. is also bordered by Springbrook Creek. Approximately 205 ft. of the fence will be constructed within the 200-ft. shoreline setback area associated with Springbrook Creek. The main purpose for the fences is to keep four-wheel drive vehicles and unauthorized persons out of the Wetland Mitigation Bank Sites,which are owned and maintained by the City of Renton. At the northern site the fence will be installed close to the right-oway line,on the wetland bank property. At the southern site we are presenting two alternatives. The first alternative is to place the fence 11 ft. within the Mitigation property,requiring more invasive clearing and tree cutting. The second alternative is to place the fence 5 ft. within the Oakesdale Ave. SW right-o€way, in a grassed strip. (Refer to the enclosed plans.) The sites will remain undeveloped and natural features will be enhanced and protected as part of the wetland mitigation bank program. The placement of a fence is in fact part of this effort. The fences shall have the following characteristics: 3.25 ft. minimum depth portholes to be set with concrete fill,poles set at 10 ft. on centers, with a Eft. above ground height;tensioned chain- link fabric;tie-rods and support wires; 3 strings of barbed wire atop, in addition to the 6-ft. height; and two 20 ft.wide access gates. The work will include removal of boulders,ecology blocks,trees and shrubs where necessary. The only access to both sites is directly off Oakesdale Ave. SW. A 20-ft. chain-link gate will be provided at each location for maintenance access. There shall not be any off-site improvements. HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27 2171 Wetland Mitigation Bank\01 Fence Proj 2003\1000 Correspond\City\Project Narrative.doc\RJS\tb The total estimated construction cost of this project is$39,100. No significant fill or excavations are required. Trees to be removed: At the northern property the fence is located so that no trees need to be removed,except for some young,2-in. diameter trees. On the southern Wetland Mitigation Bank Site property,the trees to be removed depend upon which fence alignment option is selected. The eastern right-of-way line of Oakesdale Ave. SW is 17 ft. from the existing curb along the eastern side of the street. If the fence is constructed at an offset of 12 ft. from the curb(5 ft. inside the right-of-way),then no trees will need to be removed (Option"A"). If the fence were constructed at an offset of 28 ft. from the curb(I I ft. outside of the right-of-way),then 5 to 10 trees over 8-in. diameter may need to be removed(Option`B"). We have enclosed the plan sheets,which show the fence locations. The two fence locations that are being considered for the southern site were based on avoiding conflicts with existing utilities and attempting to minimize vegetation removal. HAFile Sys\SWP-Surface Water Projects\SWP-27-Surface Water Projects(CIP)\27 2171 Wetland Mitigation Bank\O1 Fence Proj 2003\1000 Correspond\City\Project Narrative.doc\RJS\tb 0 80' 160' x \ APPROX. TREE LINE. TYPICAL e - - WETLAND BOUNDARY. \ \ .'WETLAND - - - - - - - - - - WETLAND - - - - - - - - - - - - - J` 1~ cq APPROX. TREE LINE - - - - - - - - - - - - - - - - - -= O12DINARY HIGH WATER MARK, TYPICAL , ,, t, ✓ TYPICAL I APPROX. TREE LINE, \\ JTYPICAL TREES \ TREES: 24,,. TO' 6». DRAM." o MA��H YST]NG FENCE CORNER, /�� ! �j0 FT:' FT TQ 70 . HEIGGHT_ LACE NEW CORNER POST 6" \ z FRO1J EXITING CORNER POST Q� { - - O NEW CHAIN-LINK FENCE - - - - - - - - - - - - - TYP., SEE DETAIL IN ILI ENCE OPTION "B" ? a NOTE: _ - DO NOT \ OPERTY CO SPECIAL PROVISIONS F° _ _ �LEARING =AREA " 350 LF BERRIES BEY D LAST TELEPIiON€ FEN POST `j C ! UTYP. ry°° DENSE BLACK BERRIES 20 F/ANGLE OUBLE GATE �_ S NO VS TH S SH / 10' UT. ESMT. CTR, 110' SOUTH 20' —' -SEE-NOTE FROM POST, - TEL LINE TREE AT 24' OFF FOC - - - - 45 fOG TU TREE o DIRT ROAD SEE DETAIL 2T8' FOC TO-FREE' - - = = = - - ! - \ —T —WV eg iSEE NOTE 77 ' c� - wv- _ END 0 � — _ __ Cg FACE OF CURB BUR 12.0' FTI TO FENCE FACE OF CURB %WV \ 17' OP"' 'A' 17.0' FOC TO ROW 17.0' FOC TO ROW _ OAKESDALE AVE SW cB 26D ROPERIY CORNER 28.0' FOC TO FENCE 90.O' ROW 56' CATCH BASIN, LIGHT POLE,) —63.8'--1 3 OPTION 'B' SEE NOTE 3, TYP. TYPICAL j z FENCE OPTION "A" FACE OF CURB 20 FT. DOUBLE GATE CURB'TRANSITIONS FACE OF CURB SEE DETAIL DRAWING T0:2HEIGHT TO I i I 6 NOTES: 1. 10' UTILITY ESMT. TO CITY OF RENTON, it REC. NO. 8202080435 CALL 48 HOURS BEFORE YOU DIG & TO PUGEF SOUND POWER & LIGHT CO., REC. NO. 8306240522 1-800-424-5555 2. ALL CLEARED AND DISTURBED AREAS SHALL BE HYDRO-SEEDED AFTER CONSTRUCTION IS COMPLETED. 3. TEMPORARY FILTER FABRIC CATCH BASIN SITE PROTECTION PER 1990 KCSWDM. i 4. CLEARING LIMITS: AREA 'A'; 10 FT WIDE, CENTERED ON FENCE, ALL OTHER AREAS; NORTHERN) ! 6 FT CENTERED ON FENCE, OR AS SITE NEEDED TO CONSTRUCT THE FENCE. 3 — — 1"=40' CITY OF WETLAND MITIGATION BANK 07-11-200 RIM ..0 RENTON FENCE PROJECT LOCATION FIGURE °'•�`RDR l 9/ g�Public Work: Dept. SOUTHERN SITE r, ,.a I Planninte Buildin YI ` NO. REVISION BY DATE AF'PR D - 2171 1 I I N I j r N TENSION BEAR, TYPR. 0-• ATTACHED TO POST WITH TENSION BAWDS 3 STRANDS OF POST CAP WITH SUPPORT BARBED WIREcl) TOP RAIL ARM FOR BARBED WIRE CHAIN-LINK 0 80' 160' FABRIC MIDDLE 1:960 I 6' BRACE RAIL I I LINE POST TENSION POST LINE POST —10' OC. TYPICAL--I CHAIN-LINK FENCE DETAIL j —ROW OAKESDALE AVE SW FACE OF CURB -- —•- .—...—.--•-- --- 80.0, CATCH BASIN --— -..- - �%•0' ND"'"� SEE NOTE 3., TYPICAL SAN SEWER LID. 1 ROW �— _ �_--y08" METRO SEWER �I� 1 15.0' 17.4 'S UTILITY VAUL 72"S METRO SEWER_ C 72" METRO SEWER - - _ C WALK FAC F U 36.5' 20.0' _ CONC w —-- .w —a 108'0 METRO SEW ' - 21.0 � ._� .R{�{¢-yE� �_- __._..._�„_ O o c!o o c�o o 0 0 o c o o 0 0 o o .� - �e.,.em�"s�s_ �, FENCE ANGLE F'T. 2 20.0' D o 0 0 0 0 0 0 0 0 ROW 015.0' oso o d, LOCATED AT POLE `- 6' WIDE GATE - o BOUNpARY WOBSERVED ETLAND ROPOSED FENCE LINE - - EXISTING LINE OF ECOLOGY 3' TO 4' BOU - AND GHT P _ `"_� SEE DE7All _ _ _ _ SET TWO FENCE ANGLE BLOCKS, FACE OF BLOC TfE�F1C S TO-BE -- WETLAND BOUNDARY, LIGHT POLE TH JUNCTION GRADE-BREAK GRADE BREAK IN FENCE TYPICAL POINTS AT 10' APART T MOVED INSIDE FENCE LINE IS ABOUT 36' OFF F I TYPICAL BOX.JN COJN PAD. TyP. _ 1-INE. (+BOUT_3 � _ _ _ _ VERTICAL IN 9 FEET GLEAF2 POWER VAULTS - �_,\\ SAN. SEWER LID SEE NOTE 1\\� HORIZONTAL - I - 20 FT. DOUBLE GATE, SET _ _\ _ _ _ _ - - _ INOIj CLEARING QF BRUS - _ DO_NOT pLEAR BEYCIND END bETAII, LOCATE Af EXIST. JUNCTION-BOX, TYP. AND YOUNG TREES MAY B POST. WETLAND BOUNDARY, 17/ROAD ��\ NEEDED, TYPICAL TYPICAL . _ MOVE 2-,�COLOGY BLOCKS I TO PROVIDE 20' ENTRANCE 1 WETLAND r WETLAND \� - - - - - - - - - - - i NOTES: CALL 48 HOURS BEFORE YOU DIG 1. VACANT 1-800-424-5555 2. ALL CLEARED AND DISTURBED AREAS SHALL BE HYDRO-SEEDED AFTER CONSTRUCTION IS COMPLETED. 3. TEMPORARY FILTER FABRIC CATCH BASIN PROTECTION PER 1990 KCSWDM. RN 4. CLEARING LIMITS: AREA A'; 10 FT WIDE, SITE CENTERED ON FENCE, ALL OTHER AREAS; 6 FT CENTERED ON FENCE, OR AS GAI NEEDED TO CONSTRUCT THE FENCE � NORTHERN) Avg sr SITE CITY OF WETLAND MITIGATION BANK 07-11-200 RDR -+t RENTON FENCE PROJECT RDR DATUM NORTHERN SITE LOCATION FIGURE �Dwc � Plonning/Building/Public Works Dept. NO. REVISION E?Y DATE APPR •a�s - 2 �2 D- 217102 �I M L, k �. 1 S�Vt fit. d h EEE{ fin" � �� '�-���� „1N'd�, � �E��i�^• � SS , E SW 31st St lE SDI 3 th St. iS E r� 0 m e SW 38th St Y .... O Neighborhood Detail Map 0 500 1000 1 : 6000 • s - I °� 6 SUBMITTALS FOR: 5/3/04 City of Renton 1055 South Grady Way Renton, WA 98055 Wetland Mitigation Bank Site Fence Project SWP-27-2171 Construct Co. 1621 Pease Ave Sumner, WA 98390 253-826-2050 Spec Section -9-16.1 Chain Link Fence Type 1 Commercial Fence Corp 206767SOS1 04/ZS/04 10:SBA P.001 PS POST 10' MAX PS YE TOP CAP 1 S/8" FW TOP RAIL 2.27 LBS/FT 2 7/8" FW TERM. POST 5.73 LBS/FT BRACE v E WIRE BAND PS R iL END 1 1 5/8" 72" BRACE RAIL 2.27 LBS/FT TENSION .OST 3.65 GAG BAR E CHAIN LINK FABRI �SS/FT 3/16 X 3/4 TRUSS ` ROD BOTTOM TENSION WIR 7GAGE COIL SPRING aq O _ NOTE: 1. CHAIN LINK FABRIC SELVAGE 36" SHALL BE TWIST/TWIST 2- FENCE POSTS AND RAILS SHALL BE SCHEDULE 40 FULL WEIGHT An, itd GALYANIZED FINISH �. 1D. «{ 3. CHAIN LINK FABRIC SHALL BE ATTATCHED TO FENCE POSTS WITH BRACE BANDS AT 1S INCH INTERVALS. 4- TOP AND BOTTOM OF FABRIC SHALL ATTATCHED WITH WIRE TIES AT 24 INCH INTERVALS. COMtXMRCTAT FENCE CORP P. O. BOX 80326 SEATTLE, WA 98108 - 206-767-7433 FAX: 206-767-9051 FM— 8Y: OS/10/02 SCaLL: NONC PAS: WETLAND MITIGATION FENCE — TYPE 1 xcvism: w2wu r=x: 6vzTlLamD I 1 of 3 Commercial Fence Corp Z0676790S1 04/Z9/04 10:68A P.00Z l D oN �v RQJs �ec POST CAP 6 Fr POST CAP 3" OD GATE POST S.79 LBS/FT 3" OD LATCH POST SCH 40 SCH 40 S.79 LBS/FT GATE FRAME 2" GALV. SCH 40 2.72 LBS/FT BULLDOG HINGE TOP AND BOTTOM 'r1.71laRt '� 9M CONCRETE �' �� 36" " +. 3000 PSI ate_ •.•�.�_ 1 2,i 12" NOTES: i- CHAIN LINK FABRIC SHALL BE 9 GAGE 2" GALVANIZED MESH. 2. CHAIN LINK SELVAGE - TWIST/TWIST 3, ALL MATERIALS GALVANIZED FINISH COMMMCIAL FENCE CORP P. O. BOX 80326 SEATTLE, WA 98108 206-767-7433 FAX: 206-767-9051 DRAM BY: 01/30/01. SCALL: P(7NE PAGE= SWING GATE WETLAND MITIGATION SITE atvrSLD: 04/29/04 liS.E: 5196WaTLD 2 Commercial Fence Corp 2067673061 04/2S/04 10:S8A P.002 POST CAP 6 FT *� POST CAP 3" CD GATE POST S.70 LBS/FT 3" OD LATCH POST SCH 40 SCH 40 S.73 LBS/FT GATE FRAME 2" GALV. SCH 40 2,72 LBS/FT BULLDOG HINGE TOP AND BOTTOM a4b Ve d' 1 CONCRETE -o. 36' 3000 PSI r'° 12" NOTES: 1. CHAIN LINK FABRIC SHALL BE 9 GAGE 2" GALVANIZED MESH, 2. CHAIN LINK SELVAGE - TWIST/TWIST 3, ALL MATERIALS GALVANIZED FINISH COMlIIm=AL FENCE CORP P. O. BOX 80326 SEATTLF,, WA 98108 206-767-7433 FAX: 206-767-9051 IORMH 9Y: 07/30/01 3CRLL: NONE PxGx: SWING GATE WETLAND MITIGATION SITE axv13w: 04/29/04 F=t swomw 12 nt Commercial Fence Corp 2OG7G79051 04/29/04 10:SSA P.003 DIAGONAL. CROSS BRACE S/16" DIA TRUSS ROD 2 EACH 20' OPENING 2" POST CAP POST CAP HINGE 180—DEG GATE PENYN 31 TOP & BOTTOM GATE DROII ROD TENSION BAND TENSION BAR 1/4 X 3l4 GATE LATCH GATE POST 4" (9.1 LBS/FT) 7Z" GATE FRAHE 2" OD 2-72 LBS/FT 2" NOTES: JATCH CONCRETE GATE FABRIC 2 3 GAG --TO' FENCE. CLASS C 36 •. . ;ties 2, GATE FABRIC SELvaGE SHALL BE TWIST/TI+IIST e•• d'4 • 3. FIELD VERIFY GATE OPENING SIZE •'• ~� 4. ALL MATERIALS GALVANIZED FINISH 12" CoMMKRCIAL FACE CORP P. O. Box 80326 SEATTLE, WA 98108 206-767-7433 FAx: 206-767-9051 DRAM 2Y: 05/23/01 BCAT.L: L70NL PALL: WETLANDCTIGATZON SITE — 20 DOUBLE GATES nLvisra: 04/z9/a� rurzo a 3 eF 3 Commercial Fence Corp 2067679OS1 04/29/04 10:S9A P.009 DIAGONAL CROSS BRACE S/16" DIA TRUSS ROD 2 EACH 210' OPENING 2" POST CAP POST CAP HINGE 190-DEG GATE PENIN TOP & BOTTOM GATE IDRO ROD 1 TENSION BAND TENSION BAR 1/4 X 3/4 GATE LATCH GATE POST 4" (5"1 LBS/FT) r2 GATE FRAME 2" OD 2.72 LBS/FT 2" CONCRETE ' -- NOTES: GATE FABRIC 2" 9 GAGE TO MATCH FENCE. CLASS C •.•• 2, GATE FABRIC SELVAGE SHALL BE TWIST/TWIST L�I-t 3. FIELD VERIFY GATE OPENING SIZE 4. ALL MATERIALS GALVANIZED FINISH COMMERCIAL FACE CORP p. 0. BOX 80326 SEATTLE, WA 98100 206-767-7433 FAX: 206-767-9051 To-.— MY: 05/23/01 SCA Z: NOmTE PAGi: WETLAND MITIGATION SITE - 20 DOUBLE GATES AY7SSlW: 04/z9/04 rII.A: D 3 of 3 S ,J IT 7EM 6 ) 2 ,oy 1 z fr D k Fax Cover Sheet Cons+-,ruct CO. _55.8�C-:GAO Send to: From: C Op P`X' Wfj Ht4 c it Artention Cast care 6 _ 7 �• D +n Fax Lk 2.s t.{ p. 7 2 LA ! ages 5 R E: s".b rvti hot t L�2r1�n F� ice frb'V-ct- To iego +o se :h X lJrgenl Reply ASAP J Plecse Commen _7 Phacs,= Ravnr?w J Gr�r yr�«r infrrmc7tipn Comments: Re-ire "s ok r Lb c,t•`c.-,s tl\-4 Sub r� t�-es S • !Xr +�n.E KM -L1•, n O6/01/2004 10 : 18 FAX 2539260815 FIFE SAND GRAVEL CO 001/001 SAND & GRAVEL 312D Freaman Road East Fife,Washington 98424-3623 Phone: (253)922.7710 Fax:(253)926.0815 www,fifesendandgrevei,com June 1, 2004 Mike Kelley& Family Construct Co FAX#: 820-2048 ATTN: John Doyle SUB]; Wetland Fence Project John, Our topsoil Is a screened mixture of sand, dirt, composted bark and sawdust that Is free of noxious weeds, We make the material on site at our facility. Our sand is pulled from the bank of our pit. I was unable to find any current testing results for our bank run sand, You are welcome to come grab a free sample and take it to the testing lab. If you need anything else, please give me a call. Susan Kelley Office Manager Jun 02 04 11 : 24a HYDROSEEDZNG & DRRKDLOWER 253 770-0332 P- 2 qo LETTER. OF SUBMITTAL DATFI: 2-16-01 TO: Hydroseeding & Bark Blowcl Inc. r, y FROM: Ken Doubrava. JOB: TO WHOM H' MAY CONCERN: This letter is to confirm that the 10-20-20 with trace elements and Boron is available for the above mentioned_job. The fertilizer does not contain cynamid or hydrated lime and conforms with United States and Washin9,ton State government. regulations. The T'ertilizer mix consist of the following: Ammonium Phosphate Muriate of Potash Monoammonium Phosphate Urea Perk Micro Mix Boron Sincerely, //7 / ZL Ken Doubrava WIL BUR-ELLIS COMP/aNY NOnTHF.nN DIVISION f 1521 15TH STnGFT N W SUITI::i,ALIGI ON.`NAS,I IINC,rnN gF31V1 Jun 02 04 11 : 24a HYDROSEEDING & BRRKBLOWER 253 770-0332 p. 3 i Erosion ContrOI Mulch for Hydraulic Seeding SpEeMCJMONS O Eoanbreis mtajDvfa.bturedugingspeciallyprepared whole wood chips. O Ecrotlbre usoe heat and gressuM W cld9 fib�c'es whose shape and t the mecl'aanleal,reflning proceseyi , , size is suitable for hydraulic plan.tlzag.Thte process sterilizes the fibres,eliminatizag coast n-inants that lnay inhibit grovTth. O Ecofibre uses a.non-toxic green dye tion o corat or the fibre and fao111ta.te visual monitoring of the appli O Eoofibre is packed in 50 lb.kraft double wall wet strength paper begs. wet w . t basis) 12%+3% lU[olsl•,ure content( e Organic matter(oven dryweightbasis) 99.2%''-0.2% Ash content(oven dry weight basis) 0.B%.:!-0.2% PH at 3%consistency 4.5 t 0.596 Moisture holding p0 Creme oven dry fibre) Minimum.1,250 (grams water per Availability filer N'lnrketing Intern0iuw"i hoc. �Illl ,y iIlPored roe Wood g � 1` � F��•++h�}I 1 °.. _Tr`l7'gV��iht� �{ 9y. � d } Marketing International Ine. �'r�er� IVI � I � To. CF,RTIFICATr OF COMPLIANCE for ECOFIBRE wood Fiber SneC:s i;,caLiUrls ECOFIBRE is manufactured Co meet the following turedrr`�t� 100`e whole. ECOF113RE is a virgin Wood fiber mulch the ocmech9ni� �'lFaefibrccing vrood chips. ECOFIBRE is produced in eci leci ranc.L U- berms process and manufactured to contsfn sP- f- :averaging 0. 15 inches or longer and w;-Lh 50"1. or moractecan�edrocess a 28-mesh screen (a Tyler Ro separates theLate so1Ld taood into it: of pressurized disc refining p' individual fibers and fiber bundles. ECOF1 3RE disperes rapidly ill blendster an re7n;'fert:il fertilizer ocherorm n sion under agitation. It rs form 3 e ui mane, chc tibe-� approved and specified materilantin�,foAn P homogenpn�ls slurry. applied with hydraulic p good percol,acion and strong moisture holding mac while erminacion and grot�•th. favorable micro-climate for seed B The fibers are colored green 14,OFIBRE iIn- ormlyubThele nereErlc"Ore to help the operator aPl'rass-like appearance to the `OsitrlCed;Surface- also gives a temporary g asphalt or p concrete, The dye will not stain masonry the CanEot 'Technicl�} ECOFIBRE specifications are monitored by Scientifically sound and Services group- Tests are conducted using produce slsEhtly differ- EC methods. Other test methods may ent results. 99 . 2';s 0.Z'; Moisture Matter (coral d Nyesghtbbasis) 0 $,t_0.2` Organic platter (oven dry Ash Content (oven dry height b4sis) 4 5 r0,5 water pH at 3'� consistency a`n`y 1 fiber) min. 1 , 250 poisture holding caer i00 gms oven dry (grams of eater p Representative %AfdA aq f�DlF3�2'77 � � �� Itern 8,rrxov ~ Qr`r Fox Cover Sheet Construct Co. IC�21 pca:e ���e 003c, �5.3 4 4 -1. -)4"4j (f Gt x) Send to: From: G• O R (ti N P 1.-c Li Or IC -�o r-1 w D O l C Attention: Date: c,.n :e, t CcLIrt (o • 3 . o Fax: 2 S• y 3 a - ']2 '-1 t Pages Rr_: t�ettaticl C'�enc fee, etcx - Se(e.Q.r orr Fti A X Urgent RcepIy A.`inI J Pl(t r- (-01111nerit J 'fc�,cas vI(IW J For your Informofion Comments: H 4 re 0.re tj Q re5r re 5.-c t rS For ec't be rr O'd Plo_c-e-4 cL. T' 9.e.n't6N nne K�o.,I ►' F (��:5 :s cLcLtvt-q,Eale . i Particle Size Distribution Report 100 90 7d, t i �.. ' I I 1 I I I I •,. I I _... I I ( I 11 (I - 70 — I r_.�•. I\\I I I I 1 I I � ;� t I I I I\. I I I •� I 1 I I I LU 6D ZAl I I I I \ I I u- I I I I 1 I I I I � 1 � 50 lilt I I I I I I I \ I I i I I i i -- W 40 —— n. 30 I i I - 20 10 --- `. O I o.� ao1 o.on� loa 100 10 GRAIN SIZE-mm %COPI$LES %GRAVEL %SAND %SILT ° CLAY p 7 . SIEVE PERCENT SPEC.' PASS? soil Description 512E FINER PERCENT (X=NO) Bank Run Sand with some Gravel 16 in. 100.0 100-100 Sampled on 6/ 1-1�2 in. 100.8 Sample No.040 85 99. 5 81 in. 936-55 Atterberg Limits �8 pia. 90gg.337 PL= NA LL= NA PI` NA U4 m_ 83.7 Coefficients #M. 81.0 D35= 7.10 D60= 0.807 Dgp= 0.617 #t p0 73gg.I D30= 0.420 D15= 0-295 D10= 0.233 4 30.6 0-50 Cu 3.46 C� 0.94 188 4.0 0-10 Classifl—tion USCS= SP AAStiTO= A-1-b Remarks cstcd by:Timothy I.Bergstrom -rsted oza 612JM eportcd on 6/3/04 i 9 03 14(2) Sample No.: 040885 Source of Sample: Date: 6/3/04 Location: Fife Sand and Gravel Ph Elev./Depth: Client: Renton Wetland Fen e [KRLAZAN &ASSOCIATES, INC- PToject: RcrrtoDWotIandFCnC0 Proiect No: 066-04108 ve.-� Afi:nt rooziCoi90 Carrie Olson -050314 RequestOpenNewFile.doc Page 1 E-mail to Carrie Olson REQUEST TO OPEN NEW FILE PLANNINGBUILDING/PUBLIC WORKS DATE: 3/14/2005 CONTACT PERSON: Daniel Carey Existing File or New File Title of Secondary: Wetland Mitigation Bank (label line one) Title of Tertiary(FILE NAME): 2004 Fence Project-Construction Info (label line two) (250 CHARACTERS MAXIMUM) DESCRIPTION OF FILE CONTENT: Bid Document,Material Information for 6-foot high chainlink fence construction NARRATIVE: (include retention schedule)Permanent ALIASES:Wetland Mitigation Bank Site Fence Project (250 CHARACTERS MAXIMUM EACH) SUGGESTED FILE CODE:SWP-27-2171 (PRI-XX) FOLDER TYPE: QUANTITY: I"side tab (use for shelf storage) 2"side tab (use for shelf storage) 4"side tab (use for shelf storage) 1 -4"expanding box 1"top&side tab (for desk/file cabinet,then shelf storage) LOCATION OF FILE: My Work Space: File Bay Shelf#: CH5FS025 Other: FOR FILE MAINTAINANCE USE ONLY date entered: labels made: Data_Center/Forms/PBPW/DevServ/PlanReview/RequestNewFile/bh Revised:07/2001