HomeMy WebLinkAboutSWP272172(3) CITY OF RENTON Planning/Building/Public Works Department J e Tanner,Mayor Gregg Zimmerman P.E.,Administrator October 10, 1996 Shirley Lukhang Seattle Water Real Estate Services Dexter Horton Building- RM 1112 710 Second AVE Seattle, WA 98104 SUBJECT: PERMIT FOR STORM WATER PIPE REPLACEMENT PERMIT NO.327-428 Dear Ms. Lukhang: Enclosed is a $500 check to pay for the required fee for the above-referenced permit. Also enclosed in a copy of the permit and revised construction plan showing the Seattle water pipelines on the plan and profile in accordance with Items A and B of the permit. Thank you for your assistance. If you have any questions, please call me at(206)277-5547. Sincerely, Scott Woodbury, P.E., P ject Manager Surface Water Utility H:DOCS:96-668:SW:ps Enclosures CC: Ron Straka ,T 200 Mill Avenue South - Renton, Washington 98055 ®This paper contains 50%recycled material,20%post consumer ., Seattle Water Diana Gala, Superintendent Norman B. Rica, Mayor October 7, 1996 rt. OCT a 8 i596 CITY OF RENTON Engineering Dept, Scott Woodbury City of Renton, Public Works Dept 200 Mill Avenue South Renton, WA 98055 Permit of Storm Water Pipe Replacement No. 327-428 Dear Mr. Woodbury: Enclosed is the finalized permit for the above mentioned project. Please submit $500 administration fee and a copy of the revised maps showing the SWD pipelines on the plan and profile drawings, as indicated on item A of the permit. If you have any questions please call me at 386-9754. Sincerely, Shirley Lukhang Real Estate Services Dexter Horton Building, loth Floor 710 Second Avenue Seattle,WA 98104 ��, Printed on Recycled Paper CITY OF SEATTLE-WATER DEPARTMENT UTILITY CROSSING PERMIT Permit#327428(U96-021) PERMISSION IS HEREBY GIVEN to the following named petitioner: CITY OF RENTON,200 Mill Avenue South, Renton, WA.98055, (hereinafter called Permittee)remove an existing 18 inch concrete storm water pipe and install a 24 inch CPEP storm water pipeline within the Cedar River Pipeline 1,2,3 Right-of-way,in conjunction with the Tobin/Lake Storm System Improvement Project,said crossing of approximately 10 feet is located at the intersection of South 2nd Street and Lake Avenue South, Renton,Washington,as shown on the City of Renton drawing"S.Tobin St.-Lake Ave.Storm System Improvement Project",file name 6575SD, Sheet 2 of 5.Said permit is issued conditioned upon the following terms: A. The City of Renton must show the Seattle Water Department(SWD)pipelines on their plan and profile drawings. B. Show the SWD pipelines on all profiles. C. Contractor shall keep excavating activities as close to he existing manhole as possible(shoring may be necessary). D. No disturbance to the 66"water pipeline. E. Cathodic protection facilities are located nearby(see CH2MHill drawing enclosed). Call Les Nelson at 684-5919 for further information regarding step to be taken for the protection of the pipeline. F. Potholing of the pipeline may be necessary. G. SWD must be notified 48 hours before the start of construction at(206)244,26 ir. Z2NZ. SUBJECT to City of Seattle ordinances and regulations and to the following terms and stipulations: 1. To the fullest extent permitted by law,the Permittee agrees that the City of Seattle shall not be responsible for any injury, loss or damage of any kind or description which may accrue to or be sustained by any person,firm,corporation or other entity by reason of the Permittee's sole negligence or to the extent of the Permittee's concurrent negligence in the construction, maintenance,operation or use of said installation,or the use and occupancy of the property referenced above by the Permittee, its successors or assigns. In the event any suit or action be brought against the City by reason thereof,the Permittee, its successors or assigns shall indemnify and save the City harmless therefrom,and shall upon notice to it of the commencement thereof,defend such suit or action at its sole cost and expense and will fully satisfy the final judgment rendered in any such suit or action except for that portion,if any,of such injury, loss or damage that results in such judgment, which is attributable to and results from negligence of the City,its agents,employees or officers. 2. In an emergency the Seattle Water Dept.must be notified immediately at 386-1800. 3. Permittee's use of the City's right of way shall in no way interfere with the City's present or future use of said right of way for any purpose. Work to be prosecuted with diligence,and with due respect to all property,contracts, persons, rights and the interests and convenience of the public. Permittee agrees to restore the premises to the condition found,or better. 4. If at any time the City shall install, repair or replace a pipeline or pipelines at said storm water crossing, Permittee upon written notice from the City shall temporarily remove its storm water pipe at its own expense during the City's installation, repair or replacement and shall replace same at its own expense under the supervision of the City. 5. Permittee agrees upon being billed therefor to pay for any increase in the City's cost of installing, replacing or repairing the City's pipelines or other City improvements resulting from the existence of Permittee's storm water pipe 6. Permittee agrees to pay to the City the reasonable cost of repair of any of the City's facilities damaged by the installation,operation,or maintenance of Permittee's storm water pipe. 7. Permittee agrees that the City shall not be liable for any damage to said storm water pipe by reason of any construction,alteration or improvement by the City,its agents or representatives,except where such damage is caused by the sole or comparative negligence of the City,its agents or employees. 8. The City reserves the right to institute an annual fee for this permit. 9. This permit is revocable upon thirty days notice by the Superintendent of Water. 10. This permit is not transferable. 11. One copy of this permit must be on-site during installation by Permittee or Permittee's agent. All work shall be completed by December 31.1996. 12. This permit is invalid unless approved by the City of Seattle and executed in acceptance by Permittee. 13. Payment of application fee:$500 to cover costs of administration, inspection,etc. If costs to the City of Seattle in conjunction with this permit exceed the permit fee, Permittee agrees,upon being billed,to pay such reasonable costs. APPROVED THE SEATTLE WATER DEPARTMENT B J Y ,t E'1'1 i<� Date: Sharon King, Real EstatLyManager ACCEPT0­By CITY OF RREENT,ON: By � vim^— Date: (f—T 3 155 Title UIILI-IieS oldalcxt 33' II 30 I 30' I noo S. 2ND sT. I I I REMOVE EX CB SDMH RIM-28.541 A110 RAINIER AVE. M t RIEPLAZE w EX MH TO BE 1 I y II / ♦I3� I.E.15'CMP.N.-21;5 IX YFI TO BE REN04ED. I I 1®1 7 CB RIM=28.89 I�fMG�'ED C8 WM-2fl00 W I III I SDMH 18M-29.19 LE15-CMP.S.=21 5 W ,[ LE6•CONC W.-6.9 LE.12'PVC.W.=21.a .E12-PVGE.-23.8 SWt; R1M=27.91 I TG[ RpAOyEp I.E15'CMP.S.E.-20.8 1 LE12'CMPA-23.7 I I I I III ! o I SDMH RIM=29.S2 I.E.15•CMP.N.=20.8 LE.1'CMP.N.=21.6 L'7.1Vp`r. 1 \ LE.1"CMP.S-=21.6LLI i I LEIS CMP.NW�20.6 LE6•CONG w.=23.J I IX MH TO BE REMOVED \ EJO51',BLDG(1YP� I.E.6'CONGE.=25.2 �W I N C.B.Rlu=30.37 F ; LE.18'CONC 5-20.8Lu I I 1 I LE-6'coNcsE-z6.1 (FIELD VEPoFY W/ENGINEER �`�\\` / ! I \ _ - !--- ',�`.. W. 49 OF 24'CPEP x I I.E.6'CONCE_A_() TO CONFIRM PRIOR TO \" \• LE6'CONC M1.-24.9(AB _ '� REMOVING) "\`.\\•::\ 1 RAyI� o,f N g✓ ' LE.6'CONGSW.-25.6 E)L SO k REPLACE w/ SouHR7M�30.7 7" I III I ,�: 28 LF 6"D.LDL - > I II a-- — _ _ _—� — — — E1e'eoNe z1. cone BEHOVE EXIST. k REPLACE W/ r - FfEiAdVE IX 50 REMOVE E7L SO ATAT.FIBER OPTIC CABLE J�V} I I I Ij PER DET SHT. / I °G - °CT A r.&r nBER o-TIC CABLE z I I 8 8'- i 4'CPEP 178 LF 24'CPEP m totFz ��,• I lix S'SO '--NEW CB/2 J S03'21.39"E REMOVE IX SD g f o REMOVE IX -- _ _ -----g 613.6a' RE li 8'Ex.6=50 I + I I I I k REPLACE w/ - I NEW CB k RE CPE/ I _ B. I 27 LF 24'_CF1FP-"_ REM_ 8 SD - ' • 4 \ _ r _—_ ____ _8'WATER —__- r .___ -- Y_ ___- w/ __ w. ._._- RFN04E 18LF(2 SE j IX CGNC.yy x j REMOVE t - - - - - - - -'- - - - -u= -_ -.j - - 1 F 27LF CURB k ' REPLACE W I ! Uv - -.... �a uo I� _-_�� SIDEWALX I p GUTTER Q 11 _ _ _ ➢ - I III �I 4 I I�`• , k REPLACE W APPROK LOCATION F�ER e I: / OPTIC CROSSING. USE IX CB TO BE REMOVE) REMOV EX SD B++p629 zs 18 LF 8'D.L k REPLACE W C8 05 ' _I - cH-S SO El°C.•�'T EXTREME CAUTION / F I ! RIM-20.09 FF'd= 2927 CB RIM=2797 C8 RIM=26.et > _ #t REPLACE W/ I 'C.NW. -i. 6 =26 9 LEB'CONGW.=23 i 1E.6•CONC W.-25.6 O LF 24 _._ LF 6'CONC.SE.=23 a ,-._..-_ .. __ _ ..1.E�4"PVC E.=25.0- O REMOVE IX CA I I IX C8 TO REMAIN. REN T'N HIGH SCH Y t REPLACE W/CB/36 REMOVE IX 8 t I .M<00 S. 2ND S OOL n CONNECT NEW 8'AT 1 I SAME I.E. p200 S. 2ND Si. Z 12 I 30' ! 148' 1 I `n I I V► 1 I 18 LF- 8'01 S•3.331L I I I USE SINGLE SECTION BETWEEN 28 LF- 8"D.I. S-214X CATCH BASINS NEW TYPE I CS 037 NEW TYPE RNA 28.8E I CB 136 RNA ZB BSI LE 26.80 REMOVE t REPLACE LE 26.80 r_-.----- --__._--- _—_----- 30 EX C81 NEW TYPE 1 C8 05 _-- REMOVE EX BRICK MH t REPLACE W/ I I -------- ! LEA 2'LO W M NEW 48'TYPE I CB jI IYII SOLID tAGONC COVER I REMOVE IX CONC. MH t REPLACE W/ i CONNECT EX 4'E w RNA 29.32 i II Ex NEW 48"TYPE I CB/3 W/SCJD'�OCIONG COVER ! I j w LE 21.15 24'S k NW ; I RIM 28.54 ! C8/3 i = 40 I - LE 26.20 8'SIN k SE ! .� EX SD i 0 I.E.21.40 24'S k N ' r ---- - I --- --- -------- to ----- I I i. -- I -- -- Ex. G6- — � Ld - ' I I --�W CONNECT EX 12'IN I I I CB f4 I y IX CONC.MH I I NEW CB h I I I r{. g'W i i Ex"AIH CONNECT NEW 24 N �t I t MODIFY CONG i I 20 j REMOVE IX MCK IH k REPLACE W/ I I -__--�--_.zs-. . (I III _-USE 201-F SECTION _ -- Ex. 6"SD CHANNEL.N - - A �O6-L - G Wk- ----- - OF SO PIPE LMWER - Ex. 8"w TO FIT NEW PIPE.NEW i RIM 29.19 I I I I I 8'W(W/MNL 6- USE 2aLF SECTION I.E.24'TO MATCH I I.E.21.20 24'SE t'N I I GEAR Dom.)W/END OF SO PIPE TINDER LE OF IX 18'CONC.Ni i - CONNECT EX 6'W I I O I AT CB TO EAST I ' _ ' e'w(W/MIN.6' EX GRADE AT 3oL --- I CENTERLINE OF-PAVING I -- ! ----' EX. 8' So B3x 1 AT GB TO EAST CLEAR DIST. W Do I - - -- -- -� -- f-X.Go w � i --F----2o--- - -t---io---� --- ao — Q Lxwr�eNs I c]rY of I I I' I B,W— I I ExlsnN sic�%< DRAIN� ARE &AsEO toWp,rc� 5 - r L ! -- - - ----.__-"_. REORW RF411..090 DRAWINb D-I B Tt,77rp c/rY MAKES - I f- - - - - - - - - - ---- - - '° No GIMR,A•rEE ziS 1'0 I 80 LF-2,v 5-0.19x 770 LF-24'CPEP S=O.iBx 178 LF- 'CPEP S= 0.20X 8 LF=24'CPEP S_0_20S - - R 77r A EocAT/oNS SHeWA1, SEE ! REMOVE EX MCI(MH t W/ 27 IF 24'CPEP NEW 48'TYPE I CB/4 W SOLID LOMNG COVER + - Er. S/'W S-0.19X RIM 27.91 a �, I LE. 27.76 2!-ES k NDAnW In j fa,v I I z 3 1 1 s L1 id F o 3: 72 a¢i 50+00 514-00 52+00 53+00 ¢c 0 H 54+00 ' CITY OF RENTON �` O qFOj nPEO �4P DEPARTMENT OF PTJ73LIC WORKS HORZ. SCALE 1' - 20' �S310NALE -79-16 VERT. SCALE 1' - 5 >�E61a,w 2 S. TOBIN ST. — LAKE AVE. AA STORM SYSTEM IMPROVEMENT PROJECT oATUM: N.A.V.D, M PER CITY OF RENTON BENCH MARKS ll•1ADO Wmn111A TL_ eFl S�MM !0/ . SIGNED! SW DATE: 7/1 FiE NAME: 6575SD DRAWN: MM �-/2/96 S W� 0 20 40 6o SCALE: 1' 20' eooK 629 -17-�/T$ GRAPHIC SCALE CHECKED: W. REVISION BY APP0. DATE APPROVED: SHEET' 2 OF: 6 ou� o >� o � o ho ►� p � � o 4) �v Q1 o �, o 0 0 0 0 0 0 � gh I � I I � I j j I � � I `• � I I ; I I I I I COPPER WATEP Ij C?PL NO. 2 i I ' 4 I A/O. 1 171 v 3 C,QPL ,N0..3 C I � 24 S;FOR/✓' .5'`rYER . / z- //V /IA 12 `// 49LAC,=< AIIR = ,2 4'c` c C.A< ✓1/;'Rr FLow Na�th N, T,�, AJit/EL!�c�7 -I .,- TO P/PE AND P N✓.4TC:� LIVES CC.V;'./c C cl_) PE,1/C� ELECT/;FCDES APPh'C,(. 6 ir0 /V&GATiVc 3- C OUT BUT ,-(�C%�'✓i Pi;�ES, /=C "ZZ-LCAI .51-RI/VG1_'_i✓VC T cRM/AIAL o ';FEC711=,ER SPLICE-. /4/VODE CABLE - EGE/VU REFCTir/ER r/.i'OUNTE•D TO - RO /T/VE CA84_ E (� 4 s. : ON CEME/VT PAD) - --- RECT/F-iE,"� f' GRAD ANODE I;JS : L L A T/O/1/S CABLE ` ■ iC'Er'=ERENCE ELECT✓F00ES `- i 2 Tc ST Wl,Q S _... '. . •art-- .,ev-e--c«r-vvrfr• r —._•.-^rt —T_—_ '^—a•.-•^ :St.. L TO APE C T/F:Erg ,�.._.rP� .. - - ---a --- -.. _ . _ --....- _.,.` , �.>3 WA 7-ER M E T c iE' ,8 O X a (COAVTAINS T _ST ✓//RES) CRFL ` 70'ii3:. NQ<<2 �� I CONNcECT/O/`✓S TO �MIRE To ) I C, (TY/0) I (✓'VE6Ai_i ✓F CA ` _cS_ ✓V R``5 r c r. TG J�ECT/r-/c(P Tyra) -- I i,CO-'C C C('t/ 1/ S77;,i L;a iC.`' o/V "A/VCDES' t 01A. X I 60 ., L. CORNEIL,HOWLAND.HAYES & MERRYFIELD CHZM OrVG� /.1/ COKE: �H M ILL E3/P�EZ� COL=.Jjv/N - !' �� �TY/�) CLAIR A. HILL & ASSOCIATES .�� - �� 7295-4 .572.9�".O r3-�✓-73 CITY OF RENTON w, Planning/Building/Public Works Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator October 4, 1996 Shirley Lukhang Seattle Water Real Estate Services Dexter Horton Building,Room 1112 710 Second Avenue Seattle, WA 98104 SUBJECT: PERMIT FOR STORM WATER PIPE REPLACEMENT PERMIT NO.327-428 Dear Ms. Lukhang: Enclosed are two originals of the above-referenced permit for countersignature by the Seattle Water Department. Please return a signed original as soon as possible, as we would like to start work early next week. Because of the shortness of time,I really need the permit to be processed concurrent with my getting a check cut for the $500 permit fee. Your consideration of this request is appreciated. If you need to contact me, please call me at 277-5547. Sincerely, Scott Woodbury, P.E., Project Manager Surface Water Utility U:65250:96-01 t:SW enclosures 200 Mill Avenue South Renton, Washington 98055 6)This paper contains 50%recycled material,20%post consumer CITY OF SEATTLE-WATER DEPARTMENT UTILITY CROSSING PERMIT Permit#327-428(U96-021) PERMISSION IS HEREBY GIVEN to the following named petitioner: CITY OF RENTON,200 Mill Avenue South, Renton, WA.98055,(hereinafter called Permittee)remove an existing 18 inch concrete storm water pipe and install a 24 inch CPEP storm water pipeline within the Cedar River Pipeline 1,2,3 Right-of-way,in conjunction with the Tobin/Lake Storm System Improvement Project,said crossing of approximately 10 feet is located at the intersection of South 2nd Street and Lake Avenue South, Renton,Washington,as shown on the City of Renton drawing"S.Tobin St.-Lake Ave.Storm System Improvement Project",file name 6575SD,Sheet 2 of 5. Said permit is issued conditioned upon the following terms: A. The City of Renton must show the Seattle Water Department(SWD)pipelines on their plan and profile drawings. B. Show the SWD pipelines on all profiles. C. Contractor shall keep excavating activities as close to he existing manhole as possible(shoring may be necessary). D. No disturbance to the 66"water pipeline. E. Cathodic protection facilities are located nearby(see CH2MHill drawing enclosed). Call Les Nelson at 684-5919 for further information regarding step to be taken for the protection of the pipeline. F. Potholing of the pipeline may be necessary. G. SWD must be notified 48 hours before the start of construction at(206)244-2525. SUBJECT to City of Seattle ordinances and regulations and to the following terms and stipulations: 1. To the fullest extent permitted by law,the Permittee agrees that the City of Seattle shall not be responsible for any injury,loss or damage of any kind or description which may accrue to or be sustained by any person,firm,corporation or other entity by reason of the Permittee's sole negligence or to the extent of the Permittee's concurrent negligence in the construction,maintenance,operation or use of said installation,or the use and occupancy of the property referenced above by the Permittee,its successors or assigns. In the event any suit or action be brought against the City by reason thereof,the Permittee,its successors or assigns shall indemnify and save the City harmless therefrom,and shall upon notice to it of the commencement thereof,defend such suit or action at its sole cost and expense and will fully satisfy the final judgment rendered in any such suit or action except for that portion,if any,of such injury,loss or damage that results in such judgment, which is attributable to and results from negligence of the City,its agents,employees or officers. 2. In an emergency the Seattle Water Dept.must be notified immediately at 386-1800. 3. Permittee's use of the City's right of way shall in no way interfere with the City's present or future use of said right of way for any purpose. Work to be prosecuted with diligence,and with due respect to all property,contracts,persons,rights and the interests and convenience of the public. Permittee agrees to restore the premises to the condition found,or better. 4. If at any time the City shall install,repair or replace a pipeline or pipelines at said storm water crossing,Permittee upon written notice from the City shall temporarily remove its storm water pipe at its own expense during the City's installation, repair or replacement and shall replace same at its own expense under the supervision of the City. 5. Permittee agrees upon being billed therefor to pay for any increase in the City's cost of installing,replacing or repairing the City's pipelines or other City improvements resulting from the existence of Permittee's storm water pipe 6. Permittee agrees to pay to the City the reasonable cost of repair of any of the City's facilities damaged by the installation,operation,or maintenance of Permittee's storm water pipe. 7. Permittee agrees that the City shall not be liable for any damage to said storm water pipe by reason of any construction,alteration or improvement by the City,its agents or representatives,except where such damage is caused by the sole or comparative negligence of the City,its agents or employees. 8. The City reserves the right to institute an annual fee for this permit. 9. This permit is revocable upon thirty days notice by the Superintendent of Water. 10. This permit is not transferable. 11. One copy of this permit must be on-site during installation by Permittee or Permittee's agent. All work shall be completed by December 31.1996. 12. This permit is invalid unless approved by the City of Seattle and executed in acceptance by Permittee. 13. Payment of application fee:$500 to cover costs of administration,inspection,etc. If costs to the City of Seattle in conjunction with this permit exceed the permit fee,Permittee agrees,upon being billed,to pay such reasonable costs. APPROVED BY THE SEATTLE WATER DEPARTMENT BY Date: Sharon King, Real Estate Manager ACCEPTY5`By CITY OF RENTON: BY \2 QL� Date: QLT 3 I`fi(o Title UTUrCS Qua= A I G t� � k� 0 ►� o �o 'n m C) C) 4) o 0 0 0 0 0 o � to . . (b 00 Rl 2 n V h h �;. a Cr nl COPPER AIATEP L'NE, I W GPPL NO. Z J i I i r r i a 1 1 CR,PL NO, 1 I I {Y IOU Ink Owr� 4-Me CRPL ,N0.2 V \- ":� /��/- `!' %V(C ice-1. ----,.,, -- •.. -_ l� C. / A i i'5 i;. ,Y4/4.1 n% Ti 1 � r- 12 T/,/ 3L A C,-< N/J? FL o /V, T, P_ f'c`D c .3_ C".K ✓'✓; CA D I EL.)E0 To A N D G1/.4Tc:f' L//1/E, CC:V,'✓cC`" i� i/U'c' .' rG=EQE.VCF' ELECT�C!?E .gGPRC:(. 6" ii^/11/UA� "J ;��✓ %/11: .` =h� 3.%�' 7"0 /Vc GA T/V E 3- C O U7-p U T /::WO/'✓I Pi PG�� /=0 '�r,L G// r/V c -SPL./CE A/VODE CAB LE - LEGE�VO {a . f�'�CT/f-I E� /✓'O U,N TE.D TO - GOB/T/VE C A 23L. E (-� 4 ON CEME/V T rn.4 0) - -- REC T/F/E,,' GR.4 0 E - w//F W/\ A P .� ® A/VCR -E l/VS 7 A L L A T/O/VS ,. ■ RE - /FENCE ELECT JPOJES ST Wl,R)6 " W5,17-El? METEJP 30X Q ("CO,•V 7-A//1lS TE S T ✓'/iR ESS �lp& CRhL I Cr2FL /V/ I L ECTRO DE °~h 1 i i CO/V,NEC T/O/`✓S TO P/PES 1 �TYP) i T/ VE CABLES T� S/ T 60 / LOwG) //L/ CO�� CORNELL,HOWLAND,HAYES & MERRYFIELD CNzM Yp) CLAIR A. HILL & ASSOCIATES HILL 1 vGl•+(t RS fry tlf:f H ECO+,^11,55 72:?5-4 572.9�.0 r3-1?,9-73 Seattle Water Diana Gale, Superintendent - Norman B. Rice, Mayor October 2, 1996 OCT " 3 i996 CITY OF RENTON Scott Woodbury Engineering Dept City of Renton 200 Mill Avenue So. Renton, WA 98055 Permit for Storm Water Pipe Replacement at So. 2nd Ave./Lake Ave. (Permit#327-428) Dear Mr. Woodbury: Enclosed are two original of the permit for the storm water replacement pipe that will be located in the Seattle Water Departments (SWD), Cedar River Pipeline 1, 2, 3 Right-of- way at the above mentioned location. Please have both originals signed and return both to me for the SWD final signature. A completed document will be returned to you. If you have any questions please call me at 386-9754. Sincerely, Shirley Lukhang Q Real Estate Services Dexter Horton Building, Mrflum 710 Second Avenue Seattle,WA 98104 0 Printed on Recycled Paper ' 10/01/96 16:29 FAX 206 386 9747 SEATTLE WATER 16001/001 Seattle water Fax Dlnn� qal�, zup,j,.nd.nt : 70— /— / 4 DAtO Norm— p, Rle�, Yaye� Time: 'G S Cover Shoot FAQ Number: (206)386-9747 Total number of pages (excluding corer sheet) Sent by: SHIRL�,Y I1JKK�NG Pbone 386-9754 Attention Sent to: Fax ; �' S Company: Comments Dc;:cr Hcr:cri SuiIdi:i„ lltn Floor 710 5cco,-,dAseauc Sat:le. `".; 9$ii)4 11. One copy of this permit must be on-site during installation by Permittee or Permittee's agent. All work shall be completed by December 31.1996. 12. This permit is invalid unless approved by the City of Seattle and executed in acceptance by Permittee. 13. Payment of application fee: $500 to cover costs of administration, inspection, etc. If costs to the City of Seattle in conjunction with this permit exceed the permit fee, Permittee agrees, upon being billed, to pay such reasonable costs. APPROVED BY THE SEATTLE WATER DEPARTMENT By Date Superintendent of Water ACCEPTED BY Date By Title CITY OF SEATTLE -WAT DEPARTMENT UTILITY CROSSING ERMIT PERMISSION IS REBY GIVEN to the following named pe tioner: CITY OF RENTON, 200 Mill Avenue South, Renton, WA, 98055, t 18 inch concrete storm water pipeline within the Cedar River Pipeline 1, 2, 3 Right-of-way, in conjunction wi e Tobin/Lake Storm System Improvement Project, said crossing of approximately 10 feet is located at the intersection of South 2nd Street and Lake Avenue South, Renton, Washington, as shown on the City of Renton drawing "S. Tobin St, - Lake Ave. Storm System Improvement Project" , file name 6575SD, Sheet 2 of 5. Said permit i issue conditioned upon the following terms: A. The City of Renton must show the Seattle Water Department SWD / /hL p (SWD) on their plan and profile draw)ngs. B. Show the SWD pipelines on all profiles. 5�,-/�y L-o", C. Contractor shall keep excavating activities as close to he existing manhole as possible {sh'oring may befnecessaryj���^Zn�,.r D. No disturbance to the 65"water pipeline. E. Cathodic protection facilities are located nearby (see CH2MHiIl drawing enclosed). Call Les Nelson at 684-5919 for further information regarding step to be taken for the protection of the pipeline. E. SWD must be notified 48 hours before the start of construction at(206)244-2525. � o L SUBJECT to City of Seattle ordinances and regulations and to the following terms an tipufations: 1. To the fullest extent permitted by law, the Permittee agrees that the City f Seattle shall not be responsible for any injury, loss or damage of any kind or description which may accrue to or be s ained by any person, firm, corporation or other entity by reason of the Permittee's sole negligence or to the extent of a Permittee's concurrent negligence in the construction, maintenance, operation or use of said installation, or the u and occupancy of the property referenced above by the Permittee, its successors or assigns. In the event any suit ota ion be brought against the City by reason thereof, the Permittee, its successors or assigns shall indemnify and save th Ci harmless therefrom, and shall upon notice to it of the commencement thereof, defend such suit or action at its sole cos d expense and will fully satisfy the final judgment rendered in any such suit or action except for that portion, if any, of such injury, loss or damage that results in such judgment, which is attributable to and results from negligence of the City, its agents, employees or officers_ 2. In an emergency the Seattle Water Dept. must be notified immediately at 386-1800. 3. Permittee's use of the City's right of way shall in no way interfere with the City's present or future use of said right of way for any purpose. Work to be prosecuted with diligence, and with due respect to all property, contracts, persons, rights and the interests and convenience of the public. Permittee agrees to restore the premises to the condition found, or better. 4. If at any time the City shall install, repair or replace a pipeline or pipelines at said storm water crossing, Permittee upon written notice from the City shall temporarily remove its storm water pipe at its own expense during the City's installation, repair or replacement and shall replace same at its own expense under the supervision of the City. 5. Permittee agrees upon being billed therefor to pay for any increase in the City's cost of installing, replacing or repairing the City's pipelines or other City improvements resulting from the existence of Permittee's storm water pipe 6, Permittee agrees to pay to the City the reasonable cost of repair of any of the City's facilities damaged by the installation, operation, or maintenance of Permittee's storm water pipe. 7. Permittee agrees that the City shall not be liable for any damage to said storm water pipe by reason of any construction, alteration or improvement by the City, its agents or representatives, except where such damage is caused by the sole or comparative negligence of the City, its agents or employees. 8_ The City reserves the right to institute an annual fee for this permit. 9. This permit is revocable upon thirty days notice by the Superintendent of Water. 10. This permit is not trnnsfernhNa CITY OF RENTON %v Planning/Building/Public Works Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator July 29, 1996 Donna Kruger, Property Management Seattle Water Department Dexter Horton Building, 1 lth Floor 710 Second Avenue- Room 1122 Seattle, WA 98104 SUBJECT: REQUEST FOR PERMIT TO WORK WITHIN CEDAR RIVER PIPELINE RIGHT-OF-WAY AT THE INTERSECTION OF S 2ND STREET AND LAKE AVENUE S Dear Ms. Kruger: The City of Renton requests the granting of the necessary permits from the Seattle Water Department for work within the Cedar River pipeline right-of-way at the intersection of S. 2nd Street and Lake Avenue S. The work within the Cedar River pipeline right-of-way includes the removal and replacement of a storm drainage pipeline and connection of the new pipeline to an existing catch basin. Two sets of final plans and bid specifications are attached. Because the work is north of the physical location of the pipelines, I anticipate that the potential for impact is minimal. The project will be advertised for two weeks beginning on July 31, 1996 and ending on August 14, 1996. Construction is not expected to start until mid-September. Your assistance in reviewing the plans and issuing the necessary permits and conditions before the deadline for bids is appreciated. This would allow the permits and any conditions to be issued as an addendum. In any case, we are requiring in the specifications that all work within the Cedar River pipeline right-of-way to be done in accordance with the conditions and requirements of the City of Seattle. If you have any questions, please contact my supervisor Ron Straka at 277-5548. I will be on vacation until August 5, 1996, and will contact you when I return to see if you have any questions. Your assistance is greatly appreciated. Sincerely, Scott Woodbury, P.E., Pr ject Manager Surface Water Utility U:65250:96-004:SW attachment 200 Mill Avenue South - Renton, Washington 98055 Jax_. --- . . . ___, . 33' � II 30' , I #100 S. 2ND ST. WATER 3 0 M.H.S I I REMOVE EX. CS SDMH RIM=28.54I LACE W CB T EX. MH TO BE & REP I j II / - I.E.15"CMP.N.=215 . - I i CB RIM=28.89 REMOVED I.E.15"CMP.S.=21 5 CB RIM=28.00 I III j I I.E.6"CONC NW.=26.9 SDMH RIM-29.19 I.E.12"PVC.W.=2 .0 I.E.12"P VC.E. 23.E �(. MH TO BE, REMOVED I.E.15"CMP. S.E.=20.8 I.E.12"CMP.W.=23. � I MH RIM=29. I.E.15"CMP. N.=20.8 ' I.E.15 CMP.NW.=20.6 I.E.6 CONC. W.=25.7 EX. I Ij C.B. RIM=30.37 > j LE.18"CONC.S.=20.8 I LE.6 CONC.SE.=26.1 ij (FIEL X I.E.6"CON C.E.-24.0 TO II� I j I.E.6"CONC.W.=24.9(AB 01IE EX. SD REM �+ ,/ LE.6"CONC.SW.=25.6 UVC EX. A1H T R � Ili I: � � & REPLACE W/ � w I SDMH RIM 30.37 j -�. - --- 28 LF 8—D-1.— --'1- 1-1 I 8"CONC.W.a21.4 � — -_�_ - ------ --- --- _ - LE.18"CONC — . 21. � A I�€ REMOVE EXIST. TR do -- —=- _ LE.24'coNc s. 21. REMOVE EX. SD REPLACE W/ N W EE b I PER DET SHT. / UGT UREPLACE Wr UGT - I I i P c I 110 LF 24" CPEP r L 2`saC�C a D 6 SD — — _ I I { W TE �� EW CB2 — ---- N REMOVE EX. SD g REPLACE W/ NEW CB3 o do _ — ° _ REMC . 8. 27 LF 24'_�PfP W EW CB — 8" WATER g & RE I 18l REMOVE F (2 SE REMOVE EP CE � w w � _ — I EX. CONC. D x ' N W C.",, j 21 LF CURB &REPLACE W _-- UGP \ I SIDEWALK ` \I i GUTTER L. \�\ REMOVE EX. SD APPROX. LOCATION FIBER / 1 & REPLACE W/ I ' R�. I �/ ' _ r �11C CROSSING. USE -.. � PER W.N. . I Bp1 #629--26 18 LF 8 D.I. REMOV EX. SO j CHIS.SQ.ELEC.VLT EXTREME CAUTION CB RIM=27.G1 REPLACE W/ C RIM=28.89 ELE-V.=: 29.27 . I i I. .6"C.NW.=26.9 I.E.B"CONC.W.= r+� -•- LF 24 CP _ — _ LE.6"CONC.SE. G ,ry T REMOVE EX. CB EX. CB 0 R! I do REPLACE W/ C836 REMOVE EX. c 25-r— 2-7-1Z CONNECT NE' SAME I.E. I I I ICI � i I 30 48' ,c-34 I I 18 LF — 8" D.I. S=3.33% USE SINGLE SECTION BETWEEN 28 LF — 8r D.I. S-2.14X CATCH BASINS NEW TYPE I CB #36 N �� NEW TYPE I CB �37 �I'Rc RIM 28.89 RIM 28.89 I.E. 26.80 30 I.E. 26.80 REMOVE EX. BRICK MH REPLACE W/NEW 48' TYPE II CB #1 IW/ SOLID LOCKING COVER (REMOVE EX. C)NC. MH do REPLACE! W/ RIM 29.32 I X S� INEW 48- TYPE: 11 CB 13 W SOLID ILOCKING COVER �1no.�s �/�1 e�.�''''� � �-!'SSA CITY OF RENTON .� Planning/Building/Public Works Department Jesse Tanner,Mayor Gregg Zimmerman P.E.,Administrator October 7, 1996 Kevin Oleson, Transportation Specialist Renton School District Transportation Department 435 Main Avenue S Renton, WA 98055 SUBJECT: TOBIN STREET/LAKE AVENUE STORM SYSTEM IMPROVEMENT PROJECT Dear Mr. Oleson: Thank you for attending the preconstruction conference. Attached are two 1/2 size plans for the above-referenced project per your request. I will be sending out minutes of the preconstruction meetings tomorrow. I appreciate your assistance. If you need anything else or have any other questions, please contact me at 277-5547. Sincerely, C.o w(rUTiw ,w I Scott Woodbury, P.E. Project Manager Surface Water Utility U:65250:96-012:SW enclosure 200 Mill Avenue South - Renton, Washington 98055 ®This paper contains 50%recycled material,20%post consumer 10-01-96 09 : 38 RENTON TRANSPORTATION ID=20620444SS P .01 �K0 RENTON SCHOOL DISTRICT #403 TRANSPORTATION DEPARTMENT CZ o 1220 North Fourth Street Renton, WA 98055 ` PHONE (206) 204-4455 FAX (206) 204-4465 403 TO: DATE: FROM: reV r A) O/eSOOJ FAX #: 2-35 - a Ste+ RE: LA Ke 4 �IO�I rt Pn c- # OF PAGES (including cover sheet): COMMENTS: 10-01-96 09 : 3e RENTON TRANSPORTATION ID=2062044456 P . 02 1 R$NTON SCHOOL DISTRICT #403 TRANSPORTATION DEPARTMENT 1220 NORTH 4TH STREET RENTON, WA 98055 September 30, 1996 TO: Scott Woodbury Project Coordinator City of Renton Public Works Dept. FR: Kevin Oleson Renton School Transportation Dept. RE: Project on Lake Ave & Tobin Street Per a request from someone in your office, the following are times that buses will pass through the intersection at Shattuck & Tobin OR Lake & Tobin: 11 buses @ 6150 - 7 :20 1 bus @ 7 :30 1 bus @ 7 :3 5 1 bus @ 8 :15 1 bus @ 8 :45 3 buses @ 9 : 00 - 9 : 10 1 bus @ 9 : 50 1 bus @ 10:10 1 bus @ 10:25 1 bus @ 11:25 1 bus @ 11:45 1 bus @ 12 :10 2 buses @ 12 :30 1 bus @ 1:35 12 buses @ 2 : 00 - 2 :15 1 bus @ 2 :20 1 bus @ 2 : 50 2 buses @ 3 :40 1 bus @ 3 : 50 If there are further questions, I will be in attendance at the pre-con meeting on Thursday. If you need something sooner, please give me a call at 204-4462 . 33 t I #100 S. 2ND � � 30 sT. 30 I R #110 RAINIER AVE. .s II I REMOVE EX. CB EX. MH TO BE SDMH RIM=28.54 is REPLACE W/ CB #37 I.E.15"CMP.N.=21;5 H I II REMOVED CB RIM=28.00_ w I CB "RIM-28.89 SDMH RIM=29.19 I.E.I5"CMP.S._21 5 I.E.12"PVC.E.=23.8 EX. MH TO BE REMOVED. I w I I I.E.6 CONC W.= 6. " I.E.12 PVC.W.-2 .0 MP.W.=23.7 SDMH RIM=27.91 = III I• �(, M 10 BE REMOVED I.E.15 CMP. S.E.=20.8 I.E.12 C I.E.15 CMP.N.=21.6 I 5DM IM-29.32 I.E.15"CMP. N.=20.8 - I I 1 H " I.E.15"CMP.S.=21.6 W ( co � I I.E.15 CMP.NW.=20.6 I.E.s CONC. W.-25.7 EX. MH TO BE REMOVED REMOVE EX. SD I C.B. RIM-30.37 ( I I.E.18"CONC.S.-20.8 ` ' . EAST. g�pQ I.E.6"CONC.E.=25.2 W > I FIELD VERIFY W ENGINEER �, ���';) � REPLACE W/ � u� I t I.E.6 CONC.SE.�-26.1 < / \ 49 LF 24" CPEP I.E.s"coNc.E.i24.o TO CONFIRM PRIOR TO - I 1 I.E.6"CONCH-24.9 AB QQ))— REMOVING I� R, III I " � &E EX. SD y I.E.6 CONC.SW.=25.6 ( II I REPLACE W/ ;a kx. t, II► ► 28 LF a D.I. _ SDMH RIM 30. 7 �� I - - CONC ET. PrAI. 1 I.E.1 CONC.W.-214 D I " I.E.1 8 CON C 21. � - REI�OVE IXIS'1'. TR r1t , - - I I _ - - REMOVE EX. SD REMOVE EX. SD A.T.&T. FIBER OPTIC CABLE -- UGT UGT UGT I.E.24 CONC S, 21. � - UGT ucT UGT A T R OPTIC CABLE I I REPtJ11ttE W"/ UGT — �— / A. FIRE 0 C 6,1 e I i PER K. + �"' I 110 LF 24" CPEP 178 LF 24" CPEP 15" CMP I � Q c V" SD I Ln CONC Q N w S03'21'39"E s0= I I W Cc EW CB2 REMOVE Ex. 6" so REMOVE EX. SO NEW CB $ $ 613.64 & REPLACE W �- - ' •= I " � $ � � NEW C8 r / & REPLACE W/ REMOVE EX. 8" SD #4 30 IF 8 CPEP I 27 LF 24 ..(CEP w 8 w I EW C81 8" WATER w w g REPLACE W w w w w W f • REMOVE 19LF' (2..SE - --- _ .._.:-._..... REMOVE * P CE v EX. CONC. _ _._..__._-- --..- uGP _...__.. �____...__,r.--- _--- _---.__.._._....__�� uw 21LF CURB _.._ _ - REPLACE W N W GUTTER SfDEWALK `. I _I I 4 , � � REMOVE EX. SD i j I It & REPLACE W/ APPROX. LOCATION FIBER TiC CROSSING. USE :j EX. CB TO BE REMOVED F - r l�r,� #E�2y- �6 18 LF 8 D.I. I & REPLACE W/ CB 05 PE W.N I CH1S.SQ.EL.E_t,.Vl-T EXTREME CAUTION CB RIM=27.97 CB RIM=26.81 { REMOV� EX. SD � I �` + & REPLACE W C RIM 28.89r__I_:.4. 29.27 I " - I / ; I " " _ 1.E.4 PVC.E.-25.8 O r I I. .6 C.NW.=26.9 I.E.B"CONC.W.=23.0 I.E.6»CONC.W.=25.6 O LF 24 CP REMOVE EX. CB EX6 ONTO REMAIN. *RENTON HIGH SCHOOL �' & REPLACE W/ CB J36 REMOVE EX. 8" & I #400 S. 2ND ST. `n 00 CONNECT NEW 8 AT #20o S. 2ND w z r� ST. Z I m SAME I.E. { 30148 - " � I 18 LF 8 D.I. S=3.33X I USE SINGLE SECTION BETWEEN I I ` CATCH BASINS 28 LF - � D.I. 5=2.14X I NEW TYPE I CB II NEW TYPE I C837 RIM 28.89 REMOVE �c REPLACE - RIM 28.61 I.E.E. 26.80 I.E. 26.80 EX. CB W/ NEW TYPE I CB #5 - - _ _ ( - --- ----_.------- -- I- - --- - --- _ .. _ _ _ - __ __ l _ -- ._� --- - -- - -- - --- - _, -RIM 26.81- --- ---- - -- - --- (- � REMOVE EX. BRICK MH REPLACE W/ � t I.E. 22.0 W " D LOCKING COVER I ! IREMOVE"EX. CONC. MH REPLACE; W/ I CONNECT EX. 4 E w NEW 48 TYPE II CB SOLI I I w I � / � � X so !NEW 48 TYPE II CB �3 W/ SOLID ILOCKING COVER RIM 29.32 " I; RIM 28.54 I CB I _ I.E. 21.1524 S � NW E I �I.E. 21.4024" SIN I - - - - - - - �— � � � I.E. 26.20 a SW Ic SE 9--__ - __..-___._.- •. _. ____ . _ .__ - �__- __ ___ __ __ - _ - - -. . _ ...._______ .__ _ ___ , r uj CONNECT EX 12" W 1 (40 C8 04 cn EX. 8 W I I I rL I I i EX. CB � I I I X. MH EX. CONC. MH w I NEW CB #1 I I EX. 8"w I E „ CONNECT NEW 24 N ' I I I II ! EX. 6 3D USE 0LF SECTION k MODIFY CONC. 1 REMOVE EX. BRICK H & REPLACE W _ _-- _ _ _ .---- - - - - - - - -?�--- - - - � - - - --- - -- -- - -- - - --- -- _ - _ __ _}- - ( _ _ - _ - I _�- __ - - - --- OF SO PIPE UNDER ! � � „ I - - - -- - - - W SODS LING COVER x. 8 w �N SASE NSW 4 `TYPE li � / I I r r E USE 20LF SECTION I RIM 29.19 � ( I 8 W (W/ MIN. 6 TO FIT NEW PIPE NEW I OF SD PIPE UNDER I.E. 24" To MATCH ' I — I.E. 21.20 24 SE is IN ( I — I CLEAR DIST.) W/ END — 8"w (W/ MIN. 6" I.E. OF EX. is" CONC. N' CONNECT EX 6 W EXISTING GRADE AT I AT CB TO EAST S. CLEAR DIST.) W/ END I CENTERLINE OF PAVING I „ AT CB A 30 � I I � I EXISTIN STORM DRAIN 1 I EX. 8 W EX. 8"W II II — r - - 24r CPEP S 0.18X I 178 LF - 4" CPEP S 0.20X 78 LF 24 CPEP S = 0.20% 80LF — 24" G 110LF ,. 201 BRICK MH �c PLACE W/ O REMOVE EX. r NEW 48" TYPE it C8 #4 W SOLID LOCKING COVER + 27 LF 24 CPEP S = 0.19X RIM 27.91 It I.E. 21.7624" S �CN Lo N r ~o DA rum Ks Z o J. T Q J a. > !4+00 51+00 52+00 53+00 ���*1 iti b4+00 g CITY OF RENTON 9 q 72 c ��:` DEPARTMENT OF PUBLIC WORKS W xt. HORZ. SCALE: 1" = 20' �r,,�r-�,�-� - LAKE AVE. r S. TOBIN ST. o VERT. SCALE: 1 5 EXPIRES t0/16/9"' STORM SYSTEM IMPROVEMENT PROJECT Lo n DATUM: N.A.V.D. 88; PER CITY OF RENTON BENCH MARKS DESIGNED: DATE: 7/12/96 FILE NAME: 6575SD Q 20 40 60 DRAWN: MAA SCALE: 1" = 20' FIELD BOOKI 629 rn GRAPHIC SCALE CHECKED: U NO. REVISION @Y APPR. DATE APPROVED: SHEET: 2 OF: DIR[CTOR Or rIJRL.IC WORKS