HomeMy WebLinkAbout04249 Renton WA.Rpt.0009A.2024-05-06.Concrete Compressive Strength Test.GREENReport Number:
Service Date:
Report Date:
Task:
Client
Renton, WA 98055
375 Rainier Ave S
Chick-fil-A #04249 Renton, WA (T)Chick-fil-A Inc
Attn: Kari Teresa
5200 Buffington Road
Atlanta, GA 30097-3508
425-742-9360
Lynnwood, WA 98036-6365
20225 Cedar Valley Rd Ste 110
Laboratory Services
M7241122.0009A
05/06/24
05/15/24
CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Project - M7241122
Permit No.: B23001461
Specified Strength:28 days
Mix ID:
Supplier:
Batch Time:
Truck No.:
C4000A
Corliss
Material Information
0902
130
Plant:
Ticket No.:
#1
10030192
Field Test Data
Test
Air Content (%):
Result Specification
6
64
50
3,000
Slump (in):
psi @
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Yield (Cu. Yds.):
Sample Information
Sample Date:
Sampled By:
Weather Conditions:
Sample Time:05/06/24 1010
Mohammad Zaki
Cloudy
10.5 10.5
10
0
SouthwestSample Location:
Placement Method:Pump
Water Added Before (gal):
Water Added After (gal):
Accumulative Yards:Batch Size (cy):
(6) Canopy FootingsPlacement Location:
Sample Description:4-inch diameter cylinders
Laboratory Test Data
Set Avg Diam.Area DateDate Test
Age at
Load
Max
Strength
Comp
Frac
No.ID
Spec
Received Tested (days)Type(in)(sq in)(lbs)(psi)
Tested
ByCond.
Cyl.
1 1 4.00 12.57 05/08/24 05/13/24 7 46,200 2 CMSGood 3,680
1 2 05/08/24 06/03/24 28Good
1 3 05/08/24 06/03/24 28Good
1 4 05/08/24 06/03/24 28Good
Initial Cure:Final Cure:Cure Box Moist Room
Comments:Not tested for plastic unit weight.
Samples Made By: Terracon
Special Inspections / Materials TestingServices:
Reported To:
Contractor:
Report Distribution:
See attached distribution list.Myndi Kraft
Project Manager
ESI
Jim Hibbard with ESI
Reviewed By:
ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods:
Terracon Rep.: Mohammad Zaki
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page 1 of 1CR0001, 3-31-22, Rev.7
Report Date:
Service Date:
Report Number:
Task:
M7241122.0009A
05/06/24
05/15/24
20225 Cedar Valley Rd Ste 110
Lynnwood, WA 98036-6365
425-742-9360Laboratory Services
Distribution List
Distribution Page
(1) Chick-fil-A Inc, Kari Teresa
(1) Barghausen Consulting Engineers, Inc., Alex Bell
(1) City of Renton WA, Development Engineering
(1) City of Renton WA, Patrick Decaro
(1) City of Renton WA, Yong Qi
(1) ESI Construction Inc, Eric Quevedo
(1) ESI Construction Inc, Jim Hibbard
(1) Jones Lang Lasalle, Agustin Solaberrieta
(1) Jones Lang Lasalle, Maggie Nuckols
(1) Mayes Testing Engineers, Inc, Belinda Rix
(1) Mayes Testing Engineers, Inc, Myndi Kraft