HomeMy WebLinkAboutPRE_StaffComments_240516_v1DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
|www.rentonwa.gov
PREAPPLICATION MEETING FOR
Ken Ng Residence New Lot
12047 SE 184th St
PRE24-000123
May 16, 2024
Contact Information:
Planner: Andrew Van Gordon, 425-430-7286, avangordon@rentonwa.gov
Public Works Plan Reviewer: Huy Huynh, 425-430-7384, hhuynh@rentonwa.gov
Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org
Building Department Reviewer: Rob Shuey, 206.550.8523, rshuey@rentonwa.gov
Please retain this packet throughout the course of your project as a reference. Consider
giving copies to engineers, architects, and contractors who will work on the project. You will
need to submit an PDF copy of this packet when you apply for land use and/or
environmental permits.
When the project application is ready for submittal, you may email the project planner to
start the prescreen process. Similarly, you may contact the assigned planner if there are any
questions regarding submittal requirements.
The pre-application meeting is informal and non-binding. The comments provided on the
proposal are based on the codes and policies in effect at the time of review. The applicant is
cautioned that the development regulations are regularly amended and the proposal will be
formally reviewed under the regulations in effect at the time of project submittal. The
information contained in this summary is subject to modification and/or concurrence by
official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services
Director, Development Engineering Director, Department of Community & Economic
Development Administrator, Public Works Administrator and City Council).
M E M O R A N D U M
DATE: April 30th, 2024
TO: Andrew Van Gordon, Senior Planner
FROM: Corey Thomas, Lead Plans Review Inspector
SUBJECT: Ng Short Plat
1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings
up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square
feet, a minimum of 1,500 gpm fire flow would be required. A minimum of on e fire hydrant is
required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to
1,500 gpm. Water is supplied from Soos Creek Water District. A water availability certificate is
required to be provided.
2. The fire impact fees are currently applicable at the rate of $421.98 per single family unit.
This fee is paid at building permit issuance. No charge/fee for the existing home that may be
retained or removed.
3. Fire department apparatus access roadways are required to be a minimum of 20-feet
wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways
shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required
within 150 feet of all points on all the buildings. Dead end access roadways require an
approved fire apparatus turnaround. Dead end access exceeding 300 feet requires a full 90 -
foot diameter cul-de-sac. Dead end access roadway is measured beginning at 120th Avenue
Southeast. Access as proposed does not meet minimum fire department requirements. Dead
end access roadways that exceed 500 feet require all new homes be equipped with an
approved fire sprinkler system per local city ordinance.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: May 14th, 2024
June 20, 2011
TO: Andrew Van Gordon, Planning
FROM: Huy Huynh, Development Engineering
SUBJECT: 12047 SE 184th St
PRE24-000123
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official city decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel 6199600060.
The following comments are based on the pre-application submittal made to the City of Renton by the
applicant.
WATER
1. The subject development is within the water service area of Soos Creek Water and Sewer District.
A water availability certificate from Soos Creek Water and Sewer District is required as part of the
Land use Application.
2. A copy of the water main improvements plans shall be submitted to the City of Renton as a part
of the City’s Civil Construction permit.
3. The number and locations of fire hydrants shall be determined by the City of Renton Fire
Department as part of the review of the project plans.
SEWER
1. The subject development is within the water service area of Soos Creek Water and Sewer District.
A sewer availability certificate from Soos Creek Water and Sewer District is required as a part of
the Land use Application.
2. A copy of the sewer main improvement plans shall be submitted to the City of Renton as a part of
the City’s Civil Construction permit.
Page 2 of 4
3. If the existing homes on the sites are served by private on-site septic systems, the septic systems
shall be abandoned in accordance with King County Department of Health regulations and Renton
Municipal Code.
Surface Water
1. There is an existing 12in polyethylene storm pipe fronting the property (facility ID #162722). There
is an existing stormwater catch basin fronting the property (facility ID 163878 – record drawing R-
355201)
2. Critical areas on site that may impact surface water: non-fish bearing creek.
3. Drainage plans and a drainage report complying with the adopted 2022 Renton Surface Water
Design Manual will be required. Refer to Figure 1.1.2.A – Flow Chart of the 2022 Renton Surface
Water Design Manual (RSWDM) to determine what type of drainage review is required for this
site. The site falls within the City’s Flow Control Duration Standard Area matching Forested
Conditions. The site falls within the Soos Creek drainage basin and Soos Creek Main subbasin. The
site does not fall within the City’s Aquifer Protection Area (APA).
4. The current Surface Water Standard Plans shall be used in all drainage plan submittals. The
current City of Renton Standard Details are available online in the City of Renton website
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton
5. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant
will be required to provide basic water quality treatment. Any proposed detention and/or water
quality vault shall be designed in accordance with the RSWDM that is current at the time of civil
construction permit application. Separate structural plans will be required to be submitted for
review and approval under a separate building permit for the detention and/or water quality
vault.
6. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the
new runoff created by this development to the maximum extent feasible. On-site BMPs shall be
evaluated as described in Section C.1.3 of the 2022 RSWDM. A preliminary drainage plan,
including the application of on-site BMPs, shall be included with the land use application, as
applicable to the project. The final drainage plan and drainage report must be submitted with the
utility construction permit application.
7. Any new storm conveyance installed on or off-site shall be designed and sized in accordance with
standards found in Chapter 4 of the 2022 RSWDM and shall account for the total upstream
tributary area, assuming developed conditions for onsite tributary areas and existing conditions
for any offsite tributary areas.
8. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design
Manual Section C.1.3.
9. Erosion control measures to meet the City requirements shall be provided.
10. The development is subject to a surface water system development charge (SDC) fees. Fees will
be charged based on the rate at the time of construction permit issuance.
• The current SDC fee is charged of new impervious surface is $2,300 per dwelling.
• The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=Cityof
Renton
TRANSPORTATION
1. Per City code 4-6-060 frontage improvements are required for new construction in excess of
$175,000.
Page 3 of 4
a. SE 184th St is classified as Residential Access, with an existing right-of-way (ROW) width
of approximately 60 feet. To meet the City’s complete street standards for Residential
Access streets, a minimum ROW width of 53 ft is required. Per RMC 4-6-060 half of
street improvements as taken from the ROW centerline shall be required and include a
26 foot paved road (13 feet each side), a 0.5 foot curb, an 8 foot planting strip, and a 5
foot sidewalk. No dedication will be required.
2. Refer to City code 4-4-080 regarding driveway regulations.
a. A minimum separation of 5 feet is required between driveway and the property line.
b. Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide
slotted drains.
c. The width of any driveway shall not exceed thirty feet (30') exclusive of the radii of the
returns or the taper section.
3. Undergrounding of all existing and proposed utilities is required on all frontages per RMC 4-6-090.
4. Joint use driveways are allowed for access up to 2 lots provided that each lot abuts a public
right-of-way. Refer to the shared driveway requirements as outlined in RMC 4-4-080I. Joint use
access to the driveway shall be assured by easement or other legal form acceptable to the City.
5. A shared driveway is allowed for access up to 4 lots provided at least one of the four lots abuts a
public right-of-way with at least fifty linear feet of frontage and the subject lots are not created
by a subdivision of ten or more lots. Refer to the shared driveway requirements as outlined in
RMC 4-6-060.J. Shared driveways shall be within a tract; the width of the tract and paved
surface shall be a minimum of sixteen feet; the Fire Authority may require the tract and paved
surface to be up to twenty feet wide. If a shared driveway abuts properties that are not part of
the subdivision an eight foot wide landscaped strip shall be provided between the shared
driveway and neighboring properties.
6. Per RMC 4-6-060 street lighting is not required for a project that consists of four (4) or less
residential units.
7. Paving and trench restoration within the City of Renton right of way shall comply with the City’s
Trench Restoration and Street Overlay Requirements.
8. The development is subject to transportation impact fees. Fees will be charged based on the rate
at the time of building permit issuance.
a. The 2024 transportation impact fee for SFR is $12,208.54.
b. The full fee schedule can be found at:
https://edocs.rentonwa.gov/Documents/DocView.aspx?id=10067864&dbid=1&repo=
CityofRenton.
GENERAL COMMENTS
1. A frontage improvements are required, all existing and proposed utility lines (i.e. electrical, phone,
and cable services, etc.) along property frontage or within the site must be underground as outlined
in RMC 4-6-090 – UTILITY LINES - UNDERGROUND INSTALLATION. The construction of these franchise
utilities must be inspected and approved by a City of Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the right-
of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in accordance with
code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical.
Page 4 of 4
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
4. All construction utility permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer
shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-
to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
5. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate
sheets.
6. Fees quoted in this document reflect the fees applicable in the year 2024 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to the
permit type. Please visit www.rentonwa.gov for the current development fee schedule.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE: May 16, 2024
TO: Pre-Application File No. 24-000123
FROM: Andrew Van Gordon, Associate Planner
SUBJECT: Ken Ng Residence New Lot – 12047 SE 184th St (APN 6199600060)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official decision-
makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public
Works Administrator, Planning Director, Development Services Director, Development
Engineering Director, and City Council). Review comments may also need to be revised based on
site planning and other design changes required by City staff or made by the applicant. The
applicant is encouraged to review all applicable sections of the Renton Municipal Code. The
Development Regulations are available online at https://www.codepublishing.com/WA/Renton.
Project Proposal: The applicant proposes to subdivide 12047 SE 184th St (APN 6199600060) into
four (4) lots for the benefit of detached dwellings. It is unclear how access is proposed to all the
individual lots.
Current Use: Per the provided documents a detached dwelling, barn and a vacant mobile home
are located on the property. The barn and mobile home are proposed for removal with the
existing detached dwelling to remain on Lot 4. Existing access appears to be through a joint use
driveway with 12045 SE 184th St. The project site has a gross acreage of 123,274 square feet (2.82
acres) and is located within the Residential – 4 (R-4) zoning classification. Per City of Renton (COR)
Maps, a High Erosion Hazard area and an unnamed stream are located near the southwest corner
of the property.
1. Zoning /Land Use Designation, and Overlays: The subject property is located within the R-4
zoning classification. The Residential Low Density (RLD) Comprehensive Plan Designation is
intended to implement the R-4 zone. The R-4 zone is established to promote urban single
family residential neighborhoods serviceable by urban utilities and containing open space
amenities. The R-4 allows a maximum density of four (4) dwelling units per net acre with no
minimum. The R-4 designation serves as a transition between rural designation zones and
higher density residential zones. It is intended as an intermediate lower density residential
zone.
Detached dwellings are permitted within the R-4 zone.
Ken Ng Residence New Lot
Page 2 of 8
May 16, 2024
2. Development Standards: The project would be subject to RMC 4-1-110A, Development
Standards for Residential Zoning Designations effective at the time of complete application
(noted as “R-4 standards” herein).
Density – The area of public rights-of-way, legal recorded private access easements and
critical areas (i.e. very high landslide hazard areas, protected slopes (except evaluate on a
case-by-case basis those protected slopes created by previous development, wetlands, Class
1 to 4 streams and lakes or floodways) would be dedicated from the gross site area to
determine the “net” site area prior to calculating density. In order to calculate the proposed
density of the project, any area of public road, private driveway/easement, and/or critical
area dedication must be known. All fractions which result from net density calculations shall
be truncated at two (2) numbers past the decimal (e.g. 4.5678 becomes 4.56). Calculations
for minimum or maximum density which result in a fraction that is 0.50 or greater shall be
rounded up to the nearest whole number. Those density calculations resulting in a fraction
that is less than 0.50 shall be rounded down to the nearest whole number. The R-4 zone has
a maximum density of four (4) dwelling units per acre with no minimum. Based on the
approximate gross land area of 2.82 acres, the four (4) lot proposal arrives at a gross density
of approximately 1.41 du/ac (4 lots / 2.82 gross acres = 1.41 du/ac).
A density worksheet was not included with the pre-application submittal materials;
therefore, staff was unable to verify compliance with the density requirements. A completed
density worksheet would be required with the land use application. The applicant would be
required to demonstrate compliance with the net density requirements of the zone at the
time of formal application.
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-4 zone is 9,000
square feet. In order to ensure compliance with Tier 1 requirements for Tree Preservation,
pursuant to RMC 4-4-130H.2.a, lot size and lot dimensions of the zone may be decreased by
a maximum of 10 percent (10%), provided the applicant can demonstrate to the
Administrator’s satisfaction that the reduction is necessary to ensure the preservation of all
significant trees, as defined in RMC 4-11-200, required for retention within dedicated tract(s),
pursuant to RMC 4-4-130H.1.a, Minimum Tree Retention Requirements. Minimum lot width
is 70 feet (70’) with a minimum lot depth of 100 feet (100’). The minimum lot width for corner
lots is 80 feet (80’) with a minimum lot depth of 100 feet (100’).
It is unclear why Lot 3 is below 9,000 square feet as it doesn’t appear that an exception is
applicable. Lots will not be permitted to access from SE 184th St. As such, Lot 1 and Lot 2 as
designed would not meet the minimum depth requirement. It also appears that Lot 4 is a
flag lots. Flag lots may be permitted for new plats to achieve the minimum density within
the zoning code when there is no other feasible alternative to achieving the minimum
density (RMC 4-7-170G, Flag Lots, When Allowed). As the R-4 zone has no minimum density
a flag lot would not be permitted. Submitted plans would need to show compliance with the
required lot size and dimensional standard with the land use application.
Building Standards – The R-4 standards allow a maximum building coverage of 35 percent
(35%) of the lot area. The maximum impervious surface permitted is 50 percent (50%). The
maximum wall plate height is 32 feet (32’), and the building shall not be more than three (3)
stories. Roofs with a pitch equal to or greater than 4:12 may project an additional six vertical
feet (6’) from the maximum wall plate height; common rooftop features, such as chimneys,
may project an additional four vertical feet (4’) from the roof surface. Non-exempt vertical
Ken Ng Residence New Lot
Page 3 of 8
May 16, 2024
projections (e.g., decks, railings etc.) shall not extend above the maximum wall plate height
unless the projection is stepped back one-and-a-half horizontal feet (1.5’) from each façade
for each one vertical foot (1’) above the maximum wall plate height. The maximum wall plate
height for detached accessory structures is 12 feet (12’) and the total floor area must be less
than that of the primary structure. Accessory structures are also included in building lot
coverage calculations.
New development would need to comply with the maximum building coverage, impervious
surface requirements, and building height regulations of the zone at the time of building
permit review. Existing development proposed for retention would also be required to
comply with building and coverage limitations and would be reviewed for compliance at the
time of land use application.
Setbacks – Setbacks are the minimum required distance between the building footprint and
the property line. The required setbacks for the R-4 zone are: Front yard and secondary front
yard: 30 feet (30’); Side yard: combined 20 feet (20’) with not less than seven and a half feet
(7’6”) on either side; Rear yard: 25 feet (25’). The minimum front yard setback may be reduced
to 20 feet (20’) if parking is provided in the rear yard of the lot with access from a public right-
of-way or alley. Within subdivisions, the minimum front yard and secondary front yard
setback may be reduced to no less than 20 feet (20’) provided the applicant can demonstrate
to the Administrator’s satisfaction that the setback reduction is necessary to preserve and
maintain a landmark tree within a tree protection tract, as each term is defined in RMC 4-11-
200, Definitions T. An arborist report, pursuant to RMC 4-8-120D.1, shall be prepared and
provided to the City for review and concurrence, demonstrating that the setback reduction
and project proposal serve to preserve the critical root zone of the tree within a tree
protection tract.
Compliance with required setbacks for new development would be verified at the time of
building permit application. Existing development proposed for retention would be
reviewed for compliance at the time of land use application.
3. Residential Design and Open Space Standards: Future single-family building permits would
be subject to the RMC 4-2-115, Residential Design and Open Space Standards. Requirements
should be reviewed in their entirety prior to submitting permit applications.
Compliance with building design requirements would be verified at the time of building
permit review.
4. Landscaping: With the exception of critical areas, all portions of the development area not
covered by structures, required parking, access, circulation or service areas, must be
landscaped with native, drought-resistant vegetative cover. The minimum on-site landscape
width required along street frontages is 10 feet and shall contain trees, shrubs, and
landscaping. Street trees in the ROW planter will also be required. Landscaping may include
hardscape such as decorative paving, rock outcroppings, fountains, plant containers, etc.
Minimum planting strip widths between the curb and sidewalk are established according to
the street development standards of RMC 4-6-060, Street Standards. Street trees and, at a
minimum, groundcover are to be located in this area when present. Street trees shall be
planted in the center of the planting strip between the curb and the sidewalk at the following
intervals; provided, that, where right-of-way is constrained, irregular intervals and slight
increases or decreases may be permitted or required. Additionally, trees shall be planted in
Ken Ng Residence New Lot
Page 4 of 8
May 16, 2024
locations that meet required spacing distances from facilities located in the right-of-way
including, but not limited to, underground utilities, streetlights, utility poles, traffic signs, fire
hydrants, and driveways; such spacing standards are identified in the City’s Approved Tree
List. Generally, the following spacing is required: i. Small-sized maturing trees: thirty feet (30')
on center; ii. Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized
maturing trees: fifty feet (50') on center.
A 10-foot (10’) on-sight landscaping strip would be required along SE 184th St. A conceptual
landscape plan shall be provided with the land use application as prepared by a licensed
Landscape Architect, a certified nurseryman or other certified professional. Please be aware
that frontage improvements will be required which would include street trees.
5. Significant Tree Retention: A review of COR Maps appears to show that there are mature
trees on the site. When significant trees (greater than 6-inch caliper or 8-caliper inches for
alders and cottonwoods) are proposed to be removed, a tree inventory and a tree retention
plan along with an arborist report, tree retention plan and tree retention worksheet shall be
provided with the formal land use application as defined in RMC 4-8-120. The tree retention
plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130,
Tree Retention and Land Clearing Regulations for further general and specific tree retention
and land clearing requirements.
In addition to retaining a minimum of 30% of existing significant trees, each new lot would be
required to provide a minimum tree density of 30 tree credits per net acre. Tree credits
encourage retention of existing significant trees with larger trees being worth more tree
credits.
TREE SIZE TREE CREDITS
New small species tree 0.25
New medium species tree 1
New large species tree 2
Preserved tree 6 – 9 caliper inches 4
Preserved tree 10 – 12 caliper inches 5
Preserved tree 12 – 15 caliper inches 6
Preserved tree 16 – 18 caliper inches 7
Preserved tree 19 – 21 caliper inches 8
Ken Ng Residence New Lot
Page 5 of 8
May 16, 2024
TREE SIZE TREE CREDITS
Preserved tree 22 – 24 caliper inches 9
Preserved tree 25 – 28 caliper inches 10
Preserved tree 29 – 32 caliper inches 11
Preserved tree 33 – 36 caliper inches 12
Preserved tree 37 caliper inches and greater 13
Protected trees within a subdivision shall be retained in the order of priority listed in RMC
4-4-130H.2. Protection of trees or groves by placement within a dedicated tract (Tier 1) is
the highest priority.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant
trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas
and their associated buffers; significant trees over sixty feet (60') in height or greater than
eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting
properties from strong winds, which could otherwise allow such sheltered trees to be blown
down if removed.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or
cottonwoods are used as part of an approved enhancement project within a critical area or
its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City's discretion.
The Administrator may authorize the planting of replacement trees on the site if it can be
demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4-
130H.1.e can be met.
Tree retention standards shall be applied to the developable areas, as defined in RMC 4-11-
040, Definition D, of a property. A formal tree retention plan and tree retention worksheet
prepared by an arborist or landscape architect would be reviewed at the time of the land
use application.
6. Fences/Retaining Walls: If the applicant intends to install any fences or retaining walls as part
of this project, the location must be designated on the landscape plan and grading plan with
top of wall and bottom of wall elevations. A fence and/or wall detail should also be included
Ken Ng Residence New Lot
Page 6 of 8
May 16, 2024
on the plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from
the bottom of the footing to the finish grade at the top of the wall requires a building permit.
The maximum height of any fence or retaining wall is 72-inches subject to further height
limitations in setbacks and clear vision areas noted in RMC 4-4-040D. A fence shall not be
constructed on top of a retaining wall unless the total combined height of the retaining wall
and the fence does not exceed the allowed height of a standalone fence. For more
information about fences and retaining walls refer to RMC 4-4-040.
7. Parking: Each lot is required to accommodate off street parking for a minimum of two (2)
vehicles.
8. Access/Driveways: Based on the lot dimensions on the site plan it appears that Lot 1 and Lot
2 would access from SE 184th St with Lot 4 accessing from SE 184th St via a pipestem. It is
unclear how Lot 3 would be accessed, as it appears to be landlocked.
The maximum width of single loaded garage driveways shall not exceed nine feet (9’) and
double loaded garage driveways shall not exceed 16 feet. Maximum driveway slopes shall not
exceed 15 percent; provided, that driveways exceeding eight percent (8%) shall provide
slotted drains at the lower end with positive drainage discharge to restrict runoff from
entering the garage/residence or crossing any public sidewalk. Driveways shall not be closer
than five feet (5’) to any property line except as allowed per RMC 4-4-080I.9, Joint Use
Driveways. Shared driveways may be allowed for access to four (4) or fewer residential lots
provided:
a. At least one (1) of the four (4) lots abuts a public right-of-way and the street frontage of
the lot is equal to or greater than the lot width requirement of the zone;
b. The subject lots are not created by a subdivision of 10 or more lots;
c. A public street is not anticipated by the City of Renton to be necessary for existing or
future traffic and/or pedestrian circulation through the short subdivision or to serve
adjacent property.
d. The shared driveway would not adversely affect future circulation to neighboring
properties;
e. The shared driveway is no more than 300 feet (300’) in length; and
f. The shared driveway poses no safety risk and provides sufficient access for emergency
vehicles and personnel.
Shared driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of 16 feet (16’) in width; the Fire Department may require the tract and paved
surface to be up to 20 feet (20’) wide. If a shared driveway abuts properties that are not part
of the subdivision, an eight-foot (8’) wide landscaped strip shall be provided between the
shared driveway and neighboring properties. The landscape strip shall be within a separate
tract and planted with a mixture of trees, shrubs and groundcover, as required in RMC 4-4-
070, Landscaping. The shared driveway may be required to include a turnaround per
subsection H of RMC 4-6-060, Street Standards. No sidewalks are required for shared
driveways; however, drainage improvements pursuant to City Code are required as well as an
approved pavement thickness. The maximum grade for the shared driveway shall not exceed
15 percent (15%), except for within approved hillside subdivisions.
Ken Ng Residence New Lot
Page 7 of 8
May 16, 2024
Individual lot access to SE 184th St would not be permitted. A shared driveway a minimum
of 16 feet (16’) in width would be required; the Fire Department may require the access and
paved surface to be at least 20 feet (20’) wide. If the shared driveway abuts a property not
included in the subdivision, an eight-foot (8’) wide landscaping strip would be required
along the shared property line. All lots shall access off the shared driveway. Setbacks from
the shared driveway would be classified as front yard setbacks. Of note, it appears that
current access is through a joint use driveway with 12045 SE 184th St. It would need to be
shown that access to 12045 SE 184th St is maintained to applicable standards. Compliance
with applicable requirements would be determined at the time of land use permit review.
9. Critical Areas: Per COR Maps, a High Erosion Hazard area and an unnamed stream are located
near the southwest corner of the property.
Due to the presence of geological hazards, a geotechnical study would be required at the
time of land use permit application. The study shall specifically address if the proposal will
increase the threat of the geological hazard to adjacent or abutting properties beyond pre-
development conditions; and the proposal will not adversely impact other critical areas; and
the development can be safely accommodated on the site. Additionally, because of the
unnamed stream a stream study pursuant to RMC 4-8-120, Submittal Requirements -
Specific to Application Type would be required. It is the applicant’s responsibility to
determine whether any other critical areas are present on the site prior to formal land use
application.
10. Environmental Review: Short plats are generally exempt from State Environmental Policy Act
(SEPA) review. However, the proposal would require environmental review pursuant to RMC
4-9-070, Environmental Review Procedures. A stream is located on the project site; WAC 197-
11-800 (3) does not apply. An Environmental Checklist must be submitted with the proposal
and the City’s Environmental Review Committee is required to issue a Threshold
Determination prior to any issuance for permits on the site.
11. Permit Requirements: The proposal would require administrative short plat approval and
Environmental Review. The application would be reviewed within an estimated time frame of
eight (8) weeks. The 2024 fees would total $8,274.00 ($6,080.00 Preliminary Short Plat +
$1,800.00 Environmental Review + $394.00 Technology Fee (5%) = $8,274.00). Each
modification request is $290.00. A 5% technology fee added to the total cost of the reviews
would also be assessed at the time of land use application. All fees are subject to change.
Detailed information regarding the land use permit application submittal requirements can
be found on the Short Plat Submittal Requirements checklist. Other informational
applications and handouts can be found on the City’s Digital Records Library. The City requires
electronic plan submittal for all applications. Please refer to the City’s Electronic File
Standards. A Final Short Plat application, and its associated fee, will be required following
construction of the subdivision’s infrastructure.
12. Waivers of Submittal Requirements: The submittal checklist is not an exhaustive list of
submittal requirements and may be modified in cases where additional information is
required to complete the review of an application. In addition, non-applicable submittal
requirements may be waived. The applicant should contact the assigned Project Manager if
there are any questions regarding submittal requirements.
Ken Ng Residence New Lot
Page 8 of 8
May 16, 2024
13. Public Information Sign: Public Information Signs are required for all Type II and Type III Land
Use Permits as classified by RMC 4-8-080. Public Information Signs are intended to inform the
public of potential land development, specific permits/actions being considered by the City,
and to facilitate timely and effective public participation in the review process. The applicant
must follow the specifications provided in the public information sign handout. The applicant
is solely responsible for the construction, installation, maintenance, removal, and any costs
associated with the sign.
14. Impact Fees: In addition to the applicable building and construction fees, impact fees would
be required. Fees change periodically and the fees in effect at the time of building permit
issuance would apply. For informational purposes, the 2022 impact fees are as follows:
• A Fire impact fee of $421.98 per each new detached dwelling.
• A transportation impact fee of $11,485.67 per each new detached dwelling.
• Renton School District Impact Fee of $2,161.00 (+5% administrative fee) unless an
exemption can be made under RMC 4-1-190.I.1.a per each new detached dwelling.
• Parks Impact Fee currently assessed at $3,276.44 per each new detached dwelling.
A handout listing all of the City’s Development related fees is available for your review at
https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=0&repo=CityofRe
nton
15. Next Steps: When the formal application materials are complete, the applicant shall have the
materials pre-screened prior to submitting the complete application package. Please contact
Andrew Van Gordon, Associate Planner at 425-430-7286 or avangordon@rentonwa.gov to
submit prescreen materials and subsequent land use application.
16. Expiration: Upon approval, the Short Plat is valid for five (5) years with a possible one (1) year
extension (RMC 4-7-070M, Expiration Period). It is the applicant’s responsibility to monitor
the expiration dates.