Loading...
HomeMy WebLinkAboutP_ARCH_CONSTRUCTION_FINISH_PLAN_240308_V1.pdfLEGEND (E) CONSTRUCTION TO REMAIN. G.C. TO PATCH AND REPAIR AS REQUIRED TO "LIKE -NEW" CONDITION. NEW PARTITION EXISTING DOOR & FRAME I NEW DOOR & FRAME ® DOOR NUMBER, SEE SHEET A9.02 FOR DOOR SCHEDULE PT-# FINISH, SEE SHEET A9.01 FOR FINISH SCHEDULE PARTITION TYPE, SEE SHEET A8.03 14/50 RECEPTACLE, SEE DETAIL 12/A8.02a & ELECTRICAL DRAWINGS WALL CONNECTOR, V.I.F. EXACT LOCATIONS WITH TESLA. SEE DETAIL 8/A8.02a & ELECTRICAL DRAWINGS. H.B. HOSE BIBB - FLOOR TRANSITION, SEE SHEET A8.04 FOR FLOOR - TRANSITION DETAILS KEY NOTES 1O ELECTRICAL PANEL, AND TRANSFORMER SEE ELECTRICAL DRAWINGS O3' HIGH COLUMN WRAP IN RED IF COLUMN IS 12" OR LESS IN CROSS SECTION SIZE. SEE A2.02 FOR WRAP SPEC. O3 EXTERIOR WALL CONNECTORS, SEE ELECTRICAL DRAWINGS. ONEW WALL MOUNTED INSTANTANEOUS GAS WATER HEATER, SEE PLUMBING DRAWINGS. OBOLLARD, SEE DETAIL 7/A8.02 OHOT AND COLD HOSE BIB, SEE PLUMBING DRAWINGS OMAINTAIN CLEAR WALL AREA ADJACENT TO AND ABOVE OVERHEAD DOOR FOR PUSH BUTTON AND MOTOR. SEE ELECTRICAL DRAWINGS FOR J-BOX LOCATION(S) AND MANUFACTURER DWGS FOR MOTOR INSTALLATION. O8 NEW PAD FOR LIFTS. SEE STRUCTURAL DRAWINGS O9 EXTERIOR BOLLARD, SEE DETAIL 7/A8.02 10 WALL IN FILL @ EXISTING OVERHEAD DOOR OPENINGS, TO ACCOMMODATE NEW OVERHEAD DOORS. 11 VEHICLE CIRCULATION: PROPERTY DRIVE AISLES, DRIVEWAYS AND RAMPS ETC., WILL NOT EXCEED SLOPE 1:8 12.5% 7.3° MAX. SLAB: LEVEL TO WITHIN 1/4" OVER 10' (0.2%) TYP. U.N.O. LEVET TO WITHIN 1/8" OVER 10' (0.1% UNDER 2 POST, DRIVE OVER LIFT, ALIGNMENT RACK TYP. z 0 F- a 0 L.L Z r� Ld Z_ D m J a F— z w 0 LL z O U z Q ry a w F— ry O ry w w m w F- C� J J Q U Z ui 0 0 a J w F- 0 N H 2 0 U PARTS AND STOR. 115 WALLS: PT-2 FLOOR: SC-1 BASE: VB-1 * AT GYP BD ONLY ,2A 4.0 I I - _ - 1 1.11 13 O7 2 I 3II 3_ - 4II _5II 6I 7 I III 8I 9I I 1I 1 12 13 14 - 15 I 1III 16.2 17 H04 10 H04 H04 TYP)TYP El: Li 3 _ W Cl I Zo - I O I I I 1 5 J =� — I — — I— — I — — I — — I C I I II I r G --- 1 _j-I--1 I I —I --- 1 I I I I I I---�--- I I I I I I I 1 1 1 I I 13 TYP 2 I I I I I I I I I I I I TYP -- — — —-- --- i��_ ------- ----- — e --------�----0--9--a-- -- --------------+1 — — — _ _I — — -4 I I 2 I i TYP. 8 i A06 I I 4.01 I I L T-11 �______� L _______li i I I I II I I I I I I I I I I I I I I I I I L--------- I------------- ------------ ------------ SERVIC--------------------------------------------------------- �J r_ I I --- ----------- -- E AREA 11 WALLS: FRP-1 * PT-2 FLOOR: SC-2 BASE: VB-1 *AT GYP. BD. ONLY I I I I I 1IT-1" EQ lo EQ I — — I — — I — — I — — I — I I I I I I I I I I WALLS: PT-2 17'-1" FLOOR: SC-1 EQ EQ BASE: B *GYP. BDD . ONL - - I _ _ I _ _ i _ _ I _ 6.01 I I I I r--- I I-------1 25'-01' I I I EO Ll EQ I ILu I I 0 I I I I i WASH BAY A 114 Lu I e � I _cl) I ci I 7+1 cn ----------- N1 e � o 0 I � I 1 A06 � I N I 3 1%MIN-2%MAX lyl r n 1 1 10 x� V w I 6.01 SLOPE, TYP. 39 -9 7 -9 10 j I i w --------5 1 I 1- x 5 r , I----- I -- I -- r--� I — F—_� I 5— I 4-- 6 114 r fV _J —+ — r=� — —+— —I— — — — o _ L I ° I L f 1 I L_1J I + O I I L--J -J i I I TYP 10 10 TYP I TYP 9 1 iT 0 F- 4, 1 1A is I I I -��-- CD I 1 I I — I I —J 1 I I I I I 1 I 1 II Ir FI I I I I I4===4I I I I I I I I I I I I I I I ! I I I I N CONSTRUCTION FLOOR PLAN ISCAL1/16"E1'_0 I 1 I Q o J 0 O U� y g .Ni th Q v Q Wz� Q U W� Q v CL TESLA SSD & COLLISION CENTER TRT ID #57600 600 SW 10TH ST. RENTON, WA 98057 ISSUE / REVISION 10.25.23 60% SET ISSUE 01.19.24 90% SET ISSUE 02.26.24 BID SET DRAWING TITLE CONSTRUCTION & FINISH PLAN SCALE: AS NOTED PROJECT NUMBER: 230552 SHEET NUMBER A2 0 01 z 0 F- a O w z w z D m J Q H z w C LL z 0 U z Q ry a w F— ry 0 ry LJ w m w F- J J a U Z ui 0 F- O a J w F- 0 N H 2 0 U LEGEND (E) CONSTRUCTION TO REMAIN. G.C. TO PATCH AND REPAIR AS REQUIRED TO "LIKE -NEW" CONDITION. NEW PARTITION EXISTING DOOR & FRAME NEW DOOR & FRAME ® DOOR NUMBER, SEE SHEET A9.02 FOR DOOR SCHEDULE PT-# FINISH, SEE SHEET A9.01 FOR FINISH SCHEDULE PARTITION TYPE, SEE SHEET A8.03 14/50 RECEPTACLE, SEE DETAIL 12/A8.02a & ELECTRICAL DRAWINGS WALL CONNECTOR, V.I.F. EXACT LOCATIONS WITH TESLA. SEE DETAIL 8/A8.02a & ELECTRICAL DRAWINGS. H.B. HOSE BIBB - FLOOR TRANSITION, SEE SHEET A8.04 FOR FLOOR - TRANSITION DETAILS KEY NOTES OELECTRICAL PANEL AND TRANSFORMER SEE ELECTRICAL DRAWINGS O3' HIGH COLUMN WRAP IN RED IF COLUMN IS 12" OR LESS IN CROSS SECTION SIZE. SEE A2.02 FOR WRAP SPEC. OEXTERIOR SUPERCHARGER, CHARGING POST INSTALLED ON PRECAST 3 FOOTING, PROVIDED BY TESLA, INSTALLED BY GC. ONEW WALL MOUNTED INSTANTANEOUS GAS WATER HEATER, SEE PLUMBING DRAWINGS. O5 INTERIOR BOLLARD, SEE DETAIL 10/A8.02 OHOT AND COLD HOSE BIB, SEE PLUMBING DRAWINGS OMAINTAIN CLEAR WALL AREA ADJACENT TO AND ABOVE OVERHEAD DOOR FOR PUSH BUTTON AND MOTOR. SEE ELECTRICAL DRAWINGS FOR J-BOX LOCATION(S) AND MANUFACTURER DWGS FOR MOTOR INSTALLATION. OEXTERIOR POST MOUNTED WALL CONNECTORS, SEE ELECTRICAL DRAWINGS. OWALL CONNECTOR, SEE ELECTRICAL DRAWINGS. 10 WALL IN FILL @ EXISTING OVERHEAD DOOR OPENINGS, TO ACCOMMODATE NEW OVERHEAD DOORS. 11 EXISTING MSB TO REMAIN. SEE ELECTYRICAL DRAWINGS. 12 INTERIOR ROOF ACCESS LADDER. 13 EXTERIOR BOLLARD, SEE DETAIL 7/A8.02 VEHICLE CIRCULATION: 14 PROPERTY DRIVE AISLES, DRIVEWAYS AND RAMPS ETC., WILL NOT EXCEED SLOPE 1:8 12.5% 7.3° MAX. SLAB: LEVEL TO WITHIN 1/4" OVER 10' (0.2%) TYP. U.N.O. LEVET TO WITHIN 1/8" OVER 10' (0.1% UNDER 2 POST, DRIVE OVER LIFT, ALIGNMENT RACK TYP. 15 NEW PAD FOR LIFTS. SEE STRUCTURAL DRAWINGS PARTS AND STOR. 116 WALLS: PT-2 FLOOR: SC-1 BASE: VB-1 * AT GYP BD ONLY II 2 t I I 13 4.0 1 15 16 16.1 116.2 17 18 19 20 21 22 i i 23 24 25 26 7 28 29 30 31 31.1 D32 I 1j 1 04 1 H�D " 1 1 113 H0 TYP 10 H04 A 0 0 0 0 0 0 0 0 I I o 1 ❑ 1 1 I I o I - - - - - - - ------------ 7 16 3 8 8 o I I p I I I I I I I I I I 11 L 6.1 z TYP 5 .:i I ; I o 14 i I� 14 I �� C1 1 �r--- ----- G j+--- I I I I I I I I I I I I �L----------- ---- I� I I I I 1 1 1 1 1 1 1 1 1 1 1 WASH BAY B 127lo I I SERVICE AREA 113 I I I I I WALLS: FRP-1 * PT-2 " 17'-11IT-1" FLOOR: SC-2 EQ EQ 1 EQ EQ BASE: VB-1- E *AT GYP. BD. ONLY Lu I I I I I I I I I I I I I I I I II r------------------------------------------------------- ---------------------------- ------ 601 6 — — — — — — — -------------I--------- ——--- ------------- --------------—--- —--- -- I — I I I I I II I I I I I I I III I I I 1 Z0. — I Z0. L------------------------------ 1 � I 1 � 4.01 I I I I I I I TYP 15 I 2 ,—IIiI 2- F.1 5 TYP 5 TYP o 0I —- G 14 G.1 - ----------r--------—----- ----------------r--------—T--------------ii I I I I I 9 II iL---------------------------------------- —------------------------- I-----------------Ji I --__--t------------------------------- -------------------------------------------- ------ I I 01 1 I I I I I I I I I I I I I I I I 1IT-1" I+ EQ EQ II — I — — I — — I — — I — — I — - — I — — I — — I — — I — — I — — I — — I — — I — — I — — — 1 I I 1 I I I -� I I I I I r------I-------------r------------rt—-----------I-------------r----, I I I I I I 9 Lu + 1 j 14x— I:I I I I �r----------------- ---------------------------------- - - - o o I - - - - - - iL----------------- ---- -- -t-- ------------------------__—Ji- — - - - - -- - - - - - - - I - 2-- 5 I I I I I LEI_ w5 11 1-------------1----------- 1------------ 1-------------0 1 1 TYP25 10I— I — — H H — — — — — — — — — — — -- — — — — ❑ — 1 —� 1 I o 10 o I I 1 I I I I I I i it I I 113 HO I L I TYP I 113 i i I TYP. 13 WALLS: PT-2 1 FLOOR: SC-1 BASE: VB-1 *AT GYP. BD. ONL =I UI I Qi1A N (I CONSTRUCTION FLOOR PLAN ISCAL1/16"E1'_p 1 1 Q O V J 0 O U� y g N Q A v 0 LL Wz� Lu Q $2 v CL TESLA SSD & COLLISION CENTER TRT ID #57600 600 SW 10TH ST. RENTON, WA 98057 ISSUE / REVISION 10.25.23 60% SET ISSUE 01.19.24 90% SET ISSUE 02.26.24 BID SET DRAWING TITLE CONSTRUCTION & FINISH PLAN SCALE: AS NOTED PROJECT NUMBER: 230552 SHEET NUMBER A2001A LEGEND (E) CONSTRUCTION TO REMAIN. G.C. TO PATCH AND REPAIR AS REQUIRED TO "LIKE -NEW" CONDITION. NEW PARTITION EXISTING DOOR & FRAME I\\\i �\\\ I NEW DOOR & FRAME ® DOOR NUMBER, SEE SHEET A9.02 FOR DOOR SCHEDULE PT-# FINISH, SEE SHEET A9.01 FOR FINISH SCHEDULE PARTITION TYPE, SEE SHEET A8.03 14/50 RECEPTACLE, SEE DETAIL 12/A8.02a & ELECTRICAL DRAWINGS 90 WALL CONNECTOR, V.I.F. EXACT LOCATIONS WITH TESLA. SEE DETAIL 8/A8.02a & ELECTRICAL DRAWINGS. H.B. HOSE BIBB - FLOOR TRANSITION, SEE SHEET A8.04 FOR FLOOR - TRANSITION DETAILS z O F- a O LL. z U) U) Ld z U) D m J Q F- z Ld io LL. z O U 0 z Q ry Q Ld 0- 0 ry a_ o Ld Of Ld U) Ld Of U) Of J J Q U Z ui O O a J U) Ld F- 0 N F ry O U KEY NOTES 1O ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS OTHIGH COLUMN WRAP IN RED IF COLUMN IS 12" OR LESS IN CROSS SECTION SIZE. SEE A2.02 FOR WRAP SPEC. O O CLEAN AND REFURBISH (E) STOREFRONT OR (E) DOOR TO LIKE "NEW -CONDITION", TYP. AIR CONDITIONING MINI SPLIT SYSTEM. RUN 24 HOURS / 7 DAYS A WEEK, 70OF MAXIMUM TEMP.SEE MECHANICAL DRAWINGS. OPROVIDE 1/2" WATER LINE WITH SHUT OFF FOR COFFEE MACHINE BY GC. SEE PLUMBING DRAWINGS AND INTERIOR ELEVATION(S). O6 INTERIOR ROOF LADDER. ONEW WALL MOUNTED INSTANTANEOUS GAS WATER HEATER, SEE PLUMBING DRAWINGS. Og BOLLARD, SEE DETAIL 7/A8.02 O9 1ST FLOOR TILE TO BE CENTERED ON DOOR OPENING 10 CORNER GUARD, SEE DETAIL 3/A8.01 11 DRAWING TUBE, SEE DETAIL 3/A8.04 12 FIRE EXTINGUISHER CABINET (SEMI -RECESSED), SEE DETAIL 11/A8.01 13 40 GALLON WATER HEATER WITH RECIRCULATING PUMP. SEE PLUMBING DRAWINGS. 14 NEW STOREFRONT WINDOW SYSTEM. SEE WINDOW SCHEDULE, SHEET A9.02a. 15 NEW TRENCHING FOR POWER AT SHOWROOM DESK. WOMEN'S TOILET 107 11KIIICCV -r^11 r!!!T 4AA CONF. ROOM 117 N ENLARGED CONSTRUCTION FLOOR PLAN I18 =l'- I 1 Q O V J 0 O U� y g .Ni th Q A v Ua � Wz� Q U A LLa$2CL v TESLA SSD & COLLISION CENTER TRT ID #57600 600 SW 10TH ST. RENTON, WA 98057 ISSUE / REVISION 10.25.23 60% SET ISSUE 01.19.24 90% SET ISSUE 02.26.24 BID SET DRAWING TITLE ENLARGED CONSTRUCTION & FINISH PLAN SCALE: AS NOTED PROJECT NUMBER: 230552 SHEET NUMBER A2001 B O