Loading...
HomeMy WebLinkAboutP_ARCH_EXTERIOR_ELEVATIONS_240308_V1.pdfz 0 F- Q 0 z U) U) w z V) D m J Q F— z w 0 z 0 0 0 z Q Q w Of 0- 0 Of 0- in w Of w U) w Of U) c� Of J J Q U z vi Of 0 0 J U) w F- rn 0 of 2 0 0 14 13 12 11 10 1 O 8 O O O O O O so z A4.02 (N) WALL PACK - SEE ELECTRICAL, U TYP. I Q IR36'-2 1/2" A.F.F. co T.O. GUTTER in PT-5 OVERHEAD DOOR AUTOMATIC OPEN P -8 SENSOR I 14'-0" A.F.F. o 0 0 0 0 0 T.O. O.H. DOOR I a 12'-0" A.F.F. ® T.O. (N) O.H. DOOR °r° PT-8 o NEW WALL INFILL io PT-8 I 0'-0" T.O. FINISH FLOOR I POWER WASH ENTIRE EXTERIOR BUILDING PRIOR TO PAINTING, TYP. NORTH E L E VAT I O N 1 16" = V-0" 2A (32)S 31 S 29 28 27 26 25 24 23 22 21 20 19 18 17 16.2 16.1 16 15 14 Iz POWER WASH ENTIRE EXTERIOR (N) WALL PACK - SEE ELECTRICAL, BUILDING PRIOR TO PAINTING, TYP. TYP. Iv _ Q 36'-2 1/2" A.F.F. +/- ik T.O. GUTTER 16'-6" x8'-0" OUTSIDE AIR OVERHEAD DOOR PT-5 PT-5 INTAKE LOUVER IN GARAGE. AUTOMATIC OPEN SENSOR NEW WALL INFILL PT-8 0 PT-8 0 o I OVERHEAD DOOR I AUTOMATIC OPEN I SENSOR 14'-0" A.F.F. T.O. O.H. DOOR a:PT- o I 12'-0" A.F.F. T.O. (N) O.H. DOOR PT-8 i 0 I0'-0rr POST -MOUNTED WALL SUPER CHARGER NEW WALL INFILL T.O. FINISH FLOOR CONNECTOR, TYP. CHARGING POSTS, TYP. I NORTH ELEVATION 1/16"LE1'-0" 2 14 S(16)S SG7 18 19 20 21 22 23 24 25 26 27 28 29 S S 31.1 32 z I U I POWER WASH ENTIRE EXTERIOR (N) WALL PACK - SEE ELECTRICAL, TYP. BUILDING PRIOR TO PAINTING, TYP. T.O. GUTTER I � `�' OVERHEAD DOOR I NON -ILLUMINATED SERVICE � " SIGN BY SIGN VENDOR. PROVIDE PT-5 120'-0" PT-5 AUTOMATIC OPEN SENSOR BLOCKING AS REQUIRED. 17 0 OVERHEAD DOOR AUTOMATIC OPEN E 170 NEW WALL INFILL ~ 16'-6"x8'-0" OUTSIDE SENSOR a P AIR INTAKE LOUVER IN GARAGE. I ifl (E) F D.0 0 0 Is Ira 10 PT-5 ~ 60 NEW WALL INFILL 0 Or_On (E) GAS METER KEY DROP BOX (N) 12' X12' SINGLE VISION PANEL OVERHEAD DOOR (E) TRANSFORMER T.O. FINISH FLOOR (E) ELEC. METER (N) PAINTED LOGO I (N) 12' X12' SINGLE ISION PAN L OVERHEAD DOOR SOUTH ELEVATION 11/16LE ""1'-o" 1A es E)O 4 5 O O (8� E) A4.02 10 11 12 13 14 (N) WALL PACK - SEE ELECTRICAL, TYP. _ ILLUMINATED "TESLA" SIGN BY SIGN VENDOR. PROVIDE BLO KING zl = AS REQUIRED. PROVIDE POWER TO J BOX BEHIND SIGN, CONNECT U I TO TIMER. 2'-6" H, CHANTILLY LACE LETTERS Q g 36'-2 1/2" A.F.F. I T.O. GUTTER in OVERHEAD DOOR AUTOMATIC OPEN SENSOR PT-5 1 PT-5 15-3" NON -ILLUMINATED "COLLISION" -2" PT-8 PT-8 PT-5 SIGN BY SIGN VENDOR. PROVIDE C O L L I S 10 N BLOCKING AS REQUIRED. a NEW WALL INFILL & STUCCO CD ® TO MATCH.TYP. NEW VERTICAL METAL PANEL TO MATCH ADJ. MAT'L. GC TO ENSURE SMOOTH TRANSITION ❑ w PT-8 BETWEEN EXISTING AND NEW FINISHES. (N) 12' X12' SINGLE VISION PANEL (E) WINDOWS (N) DOOR &WINDOWS 8'-0" (E) WINDOWS I (E) WINDOWS T.O. FINISH FLOOR OVERHEAD DOOR POWER WASH ENTIRE EXTERIOR KEY DROP BOX S795 NON -ILLUMINATED ADDRESS (E) DOOR & WINDOWS TEMPERED GLASS, TYP. METAL TYPE/ COLOR TO MATCH BUILDING PRIOR TO PAINTING, TYP. STOREFRONT & ENTRY DOORS SOUTH ELEVATION 1 16" = V-0" 1 Q o V J O 0 O 0 04 c) Q U U.. DO N Uwu W� v LL Q � CL TESLA SSD & COLLISION CENTER TRT I D #57600 600 SW 10TH ST. RENTON, WA 98057 ISSUE / REVISION 10.25.23 60% SET ISSUE 01.19.24 90% SET ISSUE 02.26.24 BID SET DRAWING TITLE PROPOSED EXTERIOR ELEVATIONS SCALE: AS NOTED PROJECT NUMBER: 230552 SHEET NUMBER A4001 O z 0 F- Q ry 0 z U) U) w z V) D m J Q F- z w 0 z O U 0 z Q ry Q w ry 0- 0 ry 0- 0 w Of w U) w Of U) F- Of J J Q U z (/i Of 0 0 J U) w F- rn O N F- ry 0 U 16'-3 1/2" A.F.F. +/- T.O. ROOF 10'-10" A.F.F. +/- NEW VERTICAL METAL PANEL TO MATCH ADJ. MAT'L. GC TO ENSURE SMOOTH TRANSITION BETWEEN EXIWSTING AND NEW FINISHES. J' o'-o" T.O. FINISH FLOOR (E) WINDOWS D O O F.1 O G.1 O O O E)o 2,2A A4.02 POWER WASH ENTIRE EXTERIOR 39'-8 3/4" A.F.F. BUILDING PRIOR TO PAINTING, TYP. T.O. ROOF PEAK 14- ( 36'-2 1/2" A.F.F. +/- a T.O. GUTTER PT-5 16'-3 1/2" A.F.F. +/- PT-8 PT-5 T.O. ROOF ° 0 10'-10" A.F.F. ://4B.O. CANOPY o a } 9'-7" A.F.F. PT-8 M~ q pT_g T.O. WINDOW o bouuu 0,-01, I (E) WINDOWS @ BOH T.O. FINISH FLOOR (N) WALL PACK - SEE ELECTRICAL, TO BE FROSTED TYP. NEW VERTICAL METAL PANEL TO MATCH ADJ. MAT'L. GC TO ENSURE SMOOTH TRANSITION BETWEEN EXISTING AND NEW FINISHES. WEST ELEVATION 1/16"LE1'-o" 1 2 39'-8 3/4" A.F.F. +/- T.O. ROOF PEAK 36'-2 1/2" A.F.F. +/- T.O. GUTTER (N) WALL PACK - SEE ELECTRICAL, TYP. EAST ELEVATION ISCAL1/16" E1'_0 I 1 Q o J 0. O O O c)R 8 �a � wz� w so v La CL TESLA SSD & COLLISION CENTER TRT I D #57600 600 SW 10TH ST. RENTON, WA 98057 ISSUE / REVISION 10.25.23 60% SET ISSUE 01.19.24 90% SET ISSUE 02.26.24 BID SET DRAWING TITLE PROPOSED EXTERIOR ELEVATIONS SCALE: PROJECT NUMBER: SHEET NUMBER AS NOTED 230552 A4001A O