LEGEND
(E) LANDSCAPE AREA
PROPERTY LINE
PROPERTY SET BACK
—H �— ACCESSIBLE PATH OF TRAVEL
k�� PAINTED ISTRIPING, IDT M10'I ON ENTER, AT 30 DEGREE NMUM, 6-0" WIDE AT AANGLE. WHITE
HIGH POWER POST MOUNTED WALL CONNECTOR, SEE DETAIL 1/A8.02 &
ELECTRICAL DRAWINGS.
C COMPACT STALL (8' x 16')
S STANDARD PARKING STALL (9' x 18')
EV ELECTRIC CAR CHARGING STALL (9' x 18')
A ACCESSIBLE PARKING STALL (9' x 18')
A-V ACCESSIBLE VAN PARKING STALL (9' x 18')
AREA LEGEND
TOTAL SITE SQUARE FOOTAGE: 10.05 ACRES (437,778 SF)
TOTAL BUILDING SQUARE FOOTAGE: 114,002 SF
(1 BUILDING ON SITE, 1 FLOOR)
PERCENTAGE OF LOT COVERAGE: 26%
LANDSCAPING SQUARE FOOTAGE: 51,002 SF
BUILDING HEIGHT (EXISTING): 36-2 1/2"
PARKING CALCULATIONS
RENTON, WA MUNICIPAL CODE; SECTION 4-4-080: 'PARKING, LOADING, DRIVEWAY REGULATIONS'
VEHICLE SERVICE AND REPAIR: 2.5 PARKING STALLS PER 1,000 NET S.F.
GENERAL OFFICE: 2 PARKING STALLS PER 1,000 NET S.F.
ACCESSIBLE: 1 PARKING STALL PER XX REQUIRED PARKING STALLS
VAN ACCESSIBLE: 1 PARKING STALL PER XX REQUIRED PARKING STALLS
REQUIRED
PROVIDED
SERVICE AND REPAIR
263
451
GENERAL OFFICE
14
84
ACCESSIBLE
11
10
VAN ACCESSIBLE
X
1
COMPACT PARKING
X
4
TOTAL
288
550
KEY NOTES
OPROPERTY LINE
OEGRESS DOOR, SEE 3/A0.02
ONOT USED
O(N) TRANSFORMER (UTILITY) AND CONCRETE TRANSFORMER PAD
( (E) GAS METER
O6 (E) ELECTRIC METER
OSURFACE MOUNTED KEY DROP BOX. NOTE: THRU WALL DROP BOX IS FOR HIGH
SECURITY AREAS.
OWALL -MOUNTED WALL CONNECTOR, SEE ELECTRICAL
DRAWINGS, INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
SEE DETAIL 1/A8.02
O9 (E) FIRE HYDRANT
10 (E) FIRE DEPARTMENT CONNECTION
11 POLE MOUNTED SITE LIGHTING
12 INTERNALLY ILLUMINATED 8'-0" HIGH MONUMENT SIGN, GC TO PROVIDE
POWER TO SIGN LOCATION. SIGN BY SIGNAGE VENDOR.
13 POST MOUNTED WAYFINDING SIGN BY SIGNAGE VENDOR
14 V3 CHARGING CABINET, SEE A8.02b/A8.02c FOR DETAILS.
15 CONCRETE PAD FOR CHARGING CABINET, SEE
STRUCTURAL DRAWING FOR DETAIL
16 SUPERCHARGER CHARGING POSTS, SEE A8.02b/A8.02c FOR DETAILS
17 (E) EASEMENT LOCATION
18 (E) CHAIN LINK FENCE
19 (N) CHAIN LINK GATE
20 (N) TRASH ENCLOSURE AND GATE, SEE STRUCTURAL DRAWINGS
21 (N) DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY.
SEE CIVIL DRAWINGS FOR MORE INFORMATION.
X X X
SITE PLAN ISCALE: 11
Q o
V
J O
0
O
004
g
c�a
c)
WO�
0u° cm
W�
v
Q � CL
TESLA SSD &
COLLISION CENTER
TRT I D #57600
600 SW 10TH ST.
RENTON, WA 98057
ISSUE / REVISION
10.25.23 60% SET ISSUE
01.19.24 90% SET ISSUE
02.26.24 BID SET
DRAWING TITLE
SITE PLAN
SCALE: AS NOTED
PROJECT NUMBER: 230552
SHEET NUMBER
Al 001
O