HomeMy WebLinkAboutR-429312rn
I
I
Lu
S
A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SEC. 28, TWN. 23 N., RGE. 05 E., W.M.
p
v p .
Q' v
----------------------------------
a v p p a a -----
COLUMN
p
v p
STCB 504 RIM=459.04
p v FLAGPOLE 4" PVC SW IE=457.14
v p 4" PVC W IE=456.92
4" PVC N IE=456.17 YARD DRAIN RIM=458.40
v Q o 8"_EVC�1WJE=455..38. — 4" PVC N IE=457.64
CPP S IE=455.38 \
v p v p aSOS
p as \
D BENCH'
a.it Q v
_ERA
ITS a HEDGE (TYP.) aS
FF=459.68 v p C
v
p v /
Mau /
\ \ / DRIPLINE
°�° (TYP.)
\ n
REMOVE EX ADA RAMP AND p \\ \
n a ADDITIONAL FULL CONCRETE \ \
v PANELS AS NEEDED TO \ \
L_ ° INSTALLJKE NEW ADA RAMP
.�9.D6� �459,0 �� p \ \
REMOVE EX CURB AS
NEEDED TO INSTALL THE
NEW ADA RAMP
8 58.39 v ga a \
v
458.74
v
p °
v
° p
-aS — — -
n
REMOVE EX
ASPHALT
REMOVE EX CURB
—d
-----------------d ��� d d-
— — — _ _ _ 10' WATER EASEMENT
00 ------ AFN9508031611 — ---___
_------ --- ___ --------------�--- HANDICAP RESERVED"— F
�� 't-----F- ------
-------------------DEDICATION PER AFN
_---------------- 2OM79MM27
° ----- — — — — — �-- —-----
v p
1
on
t
43667 9
`rsTEg�' �y1
NAL
STCB 514 RIM=465.42
TYPE 2; LADDER W
12" CPP N IE=461.70
12" CPP E IE=455.86
RECORD DRAWINGS
REVISION
I STA
P CITE
EE E
as
;B
)N
,IL
� as
�p STCB 508 RIM=457.58
/ 12" CPP N IE-454.43
12" CPP NW IE=454.$9
\ 12" CPP S IE=45437
REMOVE EX CURB
X— — — — — — — — — — — — — — — — — -
_READERBOARD — — —
aS
— — — -
—
— — — — — —
— — — — — — — — — — — — — — — — — — — — —
p
�
p
STCH 509 RIM-459.04
TYPE 2; NO LADDER
12" CPP NW IE=455.55
12" CPP SE IE=455.40
2660.60' _ _ 116 TH A VENUE SE _
N1° 47' 08 E — � —
SE /28/25 SURVEYED:
DESIGNED:
JAJ/SSE
DRAWN:
DJD/AJJ
CHECKED:
JAJ
BY DATE APPR APPROVED:
JAJ
SCALE:
1"=10,
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
CITY OF
RENTON
Nklspr
Planning/Building/Public Works Dept.
0
LO
0 5 10 20 O
N
SCALE 1 "=10' U
LEGEND
PROPERTY LINE
N 7933'06" E - 46.81'
SAWCUT LINE
— —
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
INLET PROTECTION
IP
CONSTRUCTION RECORD DRAWING
THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE
PREPARED BY JACOBSON CONSULTING ENGINEERS, AND HAS BEEN
EDITED TO REFLECT THE AS -BUILT CONDITIONS OF THE PROJECT.
FIELD DIMENSIONS AND INFORMATION WAS PROVIDED BY PACIFIC
EARTH WORKS, AND PROVIDED TO JACOBSON CONSULTING
ENGINEERS IN FEBRUARY 2025. JACOBSON CONSULTING ENGINEERS
DOES NOT PROVIDE ANY WARRANTY AS TO THE ACCURACY OR
COMPLETENESS OF SUCH INFORMATION PROVIDED BY OTHERS.
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CASCADE ELEMENTARY SCHOOL
PAVING AND FIELD IMPROVEMENTS
ADA DEMO & T.E.S.C. PLAN
DATE:
02/28/2
PAGE:
C301
SHEET: OF:
12 OF 4C
R-429312