Loading...
HomeMy WebLinkAboutR-429314N 0 W I- G A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SEC. 28, TWN. 23 N., RGE. 05 E., W.M. D a ° o ---------------- ° D D D v o d Q D � v D D STCB 504 RIM=459.04 v FLAGPOLE 4" PVC SW IE-457.14 4" PVC W IE=456.92 Q 4" PVC N IE=456.17 YARD DRAIN RIM=458.40 �7 8" MY' IN IF 455 38. A" DUr ni it -Are Fn D BENCH - a v v D D D v v CPP S IE=455.38 \ osas ---- as cp as - - \ HEDGE (TYP.) / as \ � C v \ / DRIPLINE 00 2" CONDUIT s LANDING L - - - - - - 459.15(EX) % 459.10(EX) 1.2 00 o o 00 459.07(EX) cv 1.0% 4 i -77 D' \ o p. 4 ° D . . . \ . 459.03(EX) 00 \ 000 oo TC 458.79 .` BC 458.29 �° V. p / / p 45$.@T(EX) 458.38 458.34 - � C 458.93 R CN BC 458.43 4 a - �4 (IS ------- a �� 458.73(EX) 32.5' % \ 1.0% 458.30 458.18 18.7' 457.99(EX) as as - as aS 1.0% / �p STCB 508 RIM=457.58 / % ¢S8 12" CPP N IE=454.43 / 0 12" CPP NW IE=454.$9 / M 12" CPP S IE=45<37 a - N \ / A 3 459.71 459.d < 459.36: _ 45 89(EX) ---------------d ��� 459.12 _ 10' WATER EASEMENT 00 -- AFN9508031611 ------___ Q :�- ------ - ' a - _ -------------------DEDICATION PER AFN �- ----------------- 20M79mm2T- 43667 9 `lSTEg�� NAL STCB 514 RIM=465.42 TYPE 2; LADDER W 12" CPP N IE=461.70 12" CPP E IE=455.86 RECORD DRAWINGS ITQ lvim mil x- - - - - - - - - - - - - - - - - - - - - - - _READERBOARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Q ° D° STCH 509 RIM-459.04 TYPE 2; NO LADDER 12" CPP NW IE=455.55 12" CPP SE IE=455.40 2660.60'„ _ _ _ 116 TH A VENUE SE _ _ N1° 4T OS E - - - SE /28/25 SURVEYED: DESIGNED: JAJ/SSE DRAWN: DJD/AJJ CHECKED: JAJ BY DATE APPR APPROVED: JAJ SCALE: 1"=10' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 AE DATUM 46R CITY OF C.' I RENTON Planning/Building/Public Works Dept. 0 LO O O 0 5 10 20 O N SCALE 1 "=10' U LEGEND PROPERTY LINE N 7933'06" E - 46.81' CONTOUR (INDEX) CONTOUR -10g- SPOT SPOT ELEVATION TC 109.86 109.36 BC 109.36 GRADE BREAK - -RIDGE- - - - - - VALLEY ASPHALT PAVEMENT CONCRETE PAVEMENT ► • : ro-: •' CONCRETE CURB CONSTRUCTION RECORD DRAWING THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED BY JACOBSON CONSULTING ENGINEERS, AND HAS BEEN EDITED TO REFLECT THE AS -BUILT CONDITIONS OF THE PROJECT. FIELD DIMENSIONS AND INFORMATION WAS PROVIDED BY PACIFIC EARTH WORKS, AND PROVIDED TO JACOBSON CONSULTING ENGINEERS IN FEBRUARY 2025. JACOBSON CONSULTING ENGINEERS DOES NOT PROVIDE ANY WARRANTY AS TO THE ACCURACY OR COMPLETENESS OF SUCH INFORMATION PROVIDED BY OTHERS. IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASCADE ELEMENTARY SCHOOL PAVING AND FIELD IMPROVEMENTS ADA GRADING PLAN DATE: 02/28/2025 FIELDBOOK: PAGE: DRAWING NO: C303 SHEET: OF, 14 OF 4C R-429314