HomeMy WebLinkAboutR-429327A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SEC. 28, TWN. 23 N., RGE. 05 E., W.M. co N w IRRIGATIONLEGEND (SYMBOLS SHOWN AT 1"=20'-0") SYMBOL ITEM MANUFACTURER / CAT NO. DESCRIPTION -REMARKS © CONTROLLER RAINMASTER RME EAGLE INSTALL PER DETAIL '3', SHEET L3.03, SEE SPECIFICATIONS. NO SYMBOL IRRIGATION METER AND STUB —OUT EXISTING TO REMAI POINT OF CONNECTION SEE PLAN ENLARGEMENT ON DETAIL 'X', SHEET LX.X. GATE / SHUTOFF VALVE NIBCO T-113—K GATE VALVE (3"), OR APPROVED EQUAL. BACKFLOW PREVENTER FEBCO 850U (3") STRAINER WILKINS SXL CAST BRONZE 'Y' STRAINER (3") MANUAL DRAIN CHAMPION 30ORS-200 ANGLE VALVE (3") QUICK COUPLER RAINBIRD #5RC 55K-1 KEY SH-2 SWIVEL HOSE ELL 200 PSI THREADED ENDS, BRONZE, SCREW IN BONNET, NON —RISING STEM, SOLID WEDGE, INSTALL PER DETAIL '5', SHEET L3.04. DOUBLE CHECK VALVE. INSTALL PER DETAIL '5', SHEET L3.04. INSTALL AT POINT OF CONNECTION AS PER DETAIL '5', SHEET L3.04. INSTALL AT POINT OF CONNECTION AND ELSEWHERE AS SHOWN ON PLAN, AS PER DETAILS '1' SHEET L3.03 AND '5' SHEET L3.04. INSTALL AT P.O.C. AND ELSEWHERE AS SHOWN ON PLAN, PER DETAILS '2' SHEET L3.03 AND '5' SHEET L3.04. PROVIDE (2) KEYS AND (2) ELLS. N ISOLATION VALVE BALL VALVE (2"), NIBCO T-580—A, BRASS BALL VALVE, INSTALL PER DETAIL OR APPROVED EQUAL. '1', SHEET L3.04, SEE SPECIFICATIONS, SIZE TO MATCH MAINLINE SIZE. MAINLINE PVC —SCHEDULE 40 3" MINIMUM SIZE UNLESS NOTED OTHERWISE, SEE SPECIFICATIONS FOR MINIMUM BURIAL DEPTH. SEE DETAIL '4', SHEET 3.04. CONTROL VALVE WEATHERMATIC MAX—DW PLASTIC CONTROL VALVE WITH PRESSURE REGULATING 10— (1 "), 15— (1-1/2"), 20— (2") DIAL, INSTALL PER DETAIL '2', SHEET L3.04. LATERALS PVC —SCHEDULE 40 SIZE AS PER PLAN, 3/4" MINIMUM. UNLABELED PIPE SECTIONS TO MATCH THE LARGEST OF THE ADJACENT PIPES. UNLABELED PIPE AT THE END OF LATERAL RUNS TO BE 3/4". SEE SPECIFICATIONS FOR MINIMUM BURIAL DEPTH. SEE DETAIL '4', SHEET L3.04. SLEEVES PVC —SCHEDULE 40 UNDER PAVEMENT SLEEVING, 4" DIAMETER UNLESS OTHERWISE INDICATED ON PLAN. TO BE INSTALLED BY LANDSCAPE CONTRACTOR AT DEPTHS SPECIFIED. SEE DETAIL '4', SHEET L2.5. NO SYMBOL EXISTING CONTROL WIRES EXISTING TO REMAIN, PRESERVE AND PROTECT. UTILIZE EXISTING WIRES WHERE NEW CONTROL VALVES ARE SHOWN. EXISTING CONTROL VALVE EXISTING TO REMAIN EXCEPT WHERE NOTED ON PLANS. PRESERVE AND PROTECT UNLESS NEW NEW VALVES ARE SHOWN. NO SYMBOL EXISTING VALVE BOXES SALVAGE EXISTING VALVE BOXES AND REINSTALL AT NEW FINISH GRADE EXISTING ROTORS REMOVE ALL EXISTING ROTORS, TYP., REPLACE WITH NEW ROTORS AS SPECIFIED IN LOCATIONS SHOW ON PLANS. EXISTING LATERALS EXISTING LATERALS TO REMAIN UNLESS NOTED OTHERWISE ON PLAN. PRESERVE AND PROTECT IN ALL AREAS UNLESS NEW IRRIGATION IS SHOWN. EXISTING LATERALS TO ABANDON CAP AND DISCONNECT FROM EXISTING OR NEW LATERALS TO REMAIN, ABANDON IN PLACE, REFER TO PLAN FOR LOCATIONS. EXISTING MAINLINE EXISTING MAINLINE TO REMAIN UNLESS NOTED OTHERWISE ON PLAN. PRESERVE AND PROTECT IN ALL AREAS UNLESS NEW MAINLINE IS SHOWN. 07 07 �7 07 TURF ROTOR TORO T7PSS-02 40 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER 5" POP—UP, ADJ ARC 45-360 DETAIL '3', SHEET L3.04. (46'-54' RADIUS) �g Og Og �g TURF ROTOR TORO T7PSS-02 40 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER 5" POP—UP, ADJ ARC 45-360 DETAIL '3', SHEET L3.04. (47'-56' RADIUS) 12 12 12 12 TURF ROTOR TORO T7PSS-02 40 PSI, ADJUST RADIUS '3', AS REQUIRED, INSTALL PER 5" POP—UP, ADJ ARC 45-360 DETAIL SHEET L3.04. (50'-57' RADIUS) ® ® TURF ROTATOR TORO TF 570Z-6P—COM W/ PRN—TA NOZZLE 40 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER ARC 60 DETAIL '3', SHEET L3.04. ® ® TURF ROTATOR TORO TF 570Z-6P—COM W/ PRN—TA NOZZLE 40 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER ADJ ARC 45-360 DETAIL '3', SHEET L3.04. ® SHRUB SPRAY TORO 570Z-6P 40 PSI, ADJUST RADIUS AS REQUIRED, INSTALL PER DETAIL '3', SHEET L3.04. TWO (2) SPECIFIED RECTANGULAR VALVE BOXES WITH LOCKING LIDS. BOLT BOXES TOGETHER FINISH GRADE SPECIFIED DRAIN VALVE MAINLINE PVC WITH THREADED OUTLET NIPPLE AND ELL PIPE MIN. 18" OFFSET FROM PVC LINE 3" PVC PIPE, THREADED ONE END MIN. 3 C.F. (24" DEPTH) DRAIN ROCK SUMP ELEVATION VIEW NOTES: 1. ALL PIPE AND FITTINGS TO BE SAME DIA. AS I.P.S. FEMALE CONNECTION TO DRAIN VALVE. 2. INSTALL ONE MANUAL DRAIN VALVE AT LOWEST POINT OF MAINLINE ON SITE, SUBJECT TO REVIEW AND APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. MANUAL DRAIN VALVE 1 1/2" = 1'-0" JUNCTION CONDUIT FOR PC SOURCE, ELECTRICAL PI SWEEP P—CA-34 SPECIFIED 10" ROUND VALVE BOX AND LID 1/4" GALV. U—BOLT 1" X 16" SCH. 40 PVC PIPE w �~ om �w 0 J U Q wry C/)D m w w U) SUPPORT EACH VALVE BOX WITH (4) BRICKS, TYP. MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP ELEVATION VIEW SPECIFIED 10" ROUND VALVE BOX, INSTALL FLUSH WITH FINISH GRADE QUICK COUPLER VALVE FINISH GRADE 1" X 16" SCH. 40 PVC PIPE, SECURE TO QUICK COUPLER WITH 1/4" GALV. U—BOLT BUSHING AS REQUIRED SCH. 80 NIPPLE, VARIABLE LENGTH AS REQUIRED (2) SCH. 80 STREET ELL W/(1) SCH. 80 SHORT NIPPLE (NO MARLEX) PVC SCH. 80 NIPPLE, 8" MIN. LENGTH MAINLINE PVC TH X TH 90 DEG. ELL (NO STREET ELL) NOTES: 1. ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER. 2. QUICK COUPLER KEY MUST CLEAR VALVE BOX. QUICK COUPLER VALVE 1 1 /2" = 1'-0" P—CA-33 SPECIFIED RAIN/FREEZE SENSOR, CONNECT CABLE TO CONTROLLER PER MANUFACTURER'S RECOMMENDATION VALVE SCHEDULE NUMBER MODEL SIZE TYPE GPM SPECIFIED AUTOMATIC IRRIGATION 1 WEATHERMATIC MAX-DW 2" TURF ROTOR 60.7 CONTROLLER. WALL MOUNT PER 2 WEATHERMATIC MAX-DW 2" TURF ROTOR 47.5 MANUFACTURER'S RECOMMENDATION. 3 WEATHERMATIC MAX-DW 2" TURF ROTOR 47.5 SEE IRRIGATION PLAN FOR LOCATION. 4 WEATHERMATIC MAX-DW 1-1/2" SHRUB ROTARY 37.67 VERIFY WITH ARCHITECT PRIOR TO 5 WEATHERMATIC MAX-DW 2" TURF ROTOR 63.6 INSTALLATION. 6 WEATHERMATIC MAX-DW 2" TURF ROTOR 47.5 7 WEATHERMATIC MAX-DW 2" SHRUB SPRAY 45.5 8 WEATHERMATIC MAX-DW 2" TURF ROTOR 55.7 9 WEATHERMATIC MAX-DW 2" TURF ROTOR 60.7 PROVIDE ADDITIONAL 3/4" WIRE 10 WEATHERMATIC MAX-DW 2" TURF ROTOR 54.9 CONDUIT TO RAIN SENSOR UNLESS 11 WEATHERMATIC MAX-DW 2" TURF ROTOR 61.5 WIRELESS SENSOR SPECIFIED 12 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 13 WEATHERMATIC MAX-DW 2" TURF ROTOR 54.1 CONDUIT FOR CONTROL WIRES, 14 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 MINIMUM SIZE AS SPECIFIED ON 15 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 IRRIGATION PLANS 16 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 17 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 PROVIDE ADDITIONAL 3/4" WIRE 18 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 CONDUIT TO BOOSTER PUMP 19 WEATHERMATIC MAX-DW 2" TURF ROTOR 44.6 FOR PUMP START RELAY 20 WEATHERMATIC MAX-DW 1-1/2" SHRUB ROTARY 20.57 SWITCH IF BOOSTER PUMP IS 21 WEATHERMATIC MAX-DW 1-1/2" SHRUB ROTARY 36.76 SPECIFIED ON LEGEND 22 WEATHERMATIC MAX-DW 1-1/2" SHRUB ROTARY 17.92 FINISH FLOOR SWEEP ELL fora 1430 NE 65th Street Seattle, WA 98115 t:206-322-1732 fora.land IRRIGATION CONTROLLER (INTERIOR WALL MOUNT) 3/4" = 1'-0" RECORD DRAWINGS EB 2/28/25 SURVEYED: DESIGNED: DRAWN: EB/AM CHECKED: Ty N 0. REVISION BY DATE AP P R APPROVED: AR SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM P—CA-35 t.R C T Y OF RENTON Nui• Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASCADE ELEMENTARY SCHOOL FIELD IMPROVEMENTS IRRIGATION LEGEND & NOTES DATE: 04/19/24 FIELDBOOK: PAGE: DRAWING NO: L3.03 SHEET: 21 OF: 40 0 Nt O 0 Nt , u R-429327