HomeMy WebLinkAboutR-429328A PORTION OF THE NW 1/4 OF THE NW 1/4 OF SEC. 28, TWN. 23 N., RGE. 05 E., W.M. co rn N 0 LLI EXISTING PVC MAINLINE, SEE PLANS FOR LOCATIONS SUPPORT EACH VALVE BOX WITH (4) BRICKS, TYP. EXISTING PVC MAINLINE a FLOW ELEVATION VIEW PLAN VIEW SPECIFIED RECTANGULAR VALVE BOX, INSTALL FLUSH WITH FINISH GRADE NEW PVC MAINLINE, DEPTH PER SPECS. PVC MALE ADAPTER GALV. UNION NIPPLE MINIMUM 1 C.F. (6" DEPTH) DRAIN ROCK SUMP NEW PVC MAINLINE VALVE BOX SPECIFIED BALL VALVE NOTES: 1. BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF BALL VALVE. INSTALL AT RIGHT ANGLE TO HARDSCAPE EDGE, INSTALL VALVE OFF -CENTER IN BOX. 2. INSTALL VALVE BOX EXTENSIONS AS REQUIRED FOR PROPER VALVE INSTALLATION AT MAINLINE DEPTH. ISOLATION / SHUT-OFF VALVE 1 1/2" = 1'-0" SEE IRRIGATION SPECS FOR BACKFILL AND COMPACTION REQUIREMENTS FINISH GRADE :...:IIIUf "w Ld LLJ can':.: ;..:0 ...:. I— - 6" MIN. SECTION VIEW PVC NON -PRESSURE LATERAL LINE PIPE PVC PRESSURE MAINLINE PIPE CONTROL WIRE BUNDLE, TAPED TO MAINLINE 2" CLEAN BACKFILL UNDER ALL PIPING, SEE SPECS FOR REQUIREMENTS PVC SLEEVE, ONE PIPE ONLY PER SLEEVE, DEPTH AS SPECIFIED NOTES: 1. NO OTHER TRADES (ELECT. LIGHTING) ALLOWED TO USE SAME TRENCH AS IRRIGATION PIPE. 2. PROVIDE 24" COVER FOR DIRECT BURIAL CABLE. 3. PROVIDE PVC SCH. 40 SLEEVES FOR ALL WIRING AND PIPING UNDER PAVING. 4. NO STACKING (VERTICALLY) OF PIPES IN SAME TRENCH. PIPE TRENCHING AND BACKFILL 1 1/2" = 1'-0" P-CA-09 SPECIFIED RECTANGULAR VALVE BOX, INSTALL TOP OF LID FLUSH WITH FINISH GRADE SPECIFIED AUTOMATIC CONTROL VALVE, INSTALL PRESSURE REGULATING DIAL IF SHOWN ON LEGEND 11 PVC UNION 24" SPARE WIRE COIL, SEE SPECS FOR QUANTITY PVC BALL VALVE, COMMERCIAL GRADE I 3" 111 P I f CLR. I SET HEADS PLUMB ES FINISH GRADE EXCEPT DOERE NOTGALOW SPECIFIED SPLICE KITS USE BOTTOM INLET ONLY 24" CONTROL WIRE zo z = NEW PVC RISER, - _ COIL IN BOX F J SAME SIZE AS v Q w INLET 0 1" MIN. CLEARANCE v w J NEW OR EXISTNIG PVC LATERAL, _ BETWEEN VALVE BOX w a Q REFER TO PLANS FOR ry AND PIPE can J D NEW/EXISTING LOCATIONS, P P FLU w p 0° BURIAL DEPTH IIN. N Li_ PER SPECIFICATIONS 11- _. PVC UNION J PROVIDE CORRECT SIZE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF THE BOX WITHOUT USING 90 DEG. ELLS OR 45 DEG. ELL. MAINLINE, SIZE PER PLAN CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. NEW OR EXISTING PVC LATERAL PIPE, REFER TO PLANS FOR LOCATIONS OF EXISTING/NEW SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. REMOTE CONTROL VALVE - WITH SHUT-OFF 1 1/2" = 1'-0" GATE VALVE r STRAINER METERED STUB SPECIFIED JUMBO -SIZED VALVE BOX, INSTALL FLUSH WITH FINISH GRADE DOUBLE CHECK BACKFLOW PREVENTER P-CA-29 �45° NOTES: 1. TEMPORARILY CAP RISERS FOR PRESSURE TESTING. 2. SEAL ALL JOINTS W/ TEFLON TAPE ON MALE THREADS ELEVATION VIEW ONLY. 3. DO NOT OVERTIGHTEN GALV. TO PVC JOINTS. 4. ALL THREADED PVC PIPE SHALL BE SCH. 80, ALL PVC FITTINGS SHALL BE SCH. 40. 5. NO CLOSE NIPPLES PERMITTED. 6. ALL FITTINGS AND PIPE SAME DIA. AS IPS FEMALE CONNECTION OF SPRINKLER HEAD OR Q.C. 7. INSTALL SO PIPING WILL NOT CONTACT LATERAL. 8. ADJUST SPRAY RADIUS AS REQUIRED. PLAN VIEW IRRIGATION HEAD 3" = 1 ' -0" TWO (2) SPECIFIED RECTANGULAR VALVE BOXES, INSTALL FLUSH WITH FINISH GRADE r MANUAL I DRAIN VALVE UNION II II I/ = III 6" MIN. _ CLR. - MINIMUM 6 C.F. (12" ELEVATION VIEW DEPTH) DRAIN ROCK SUMP SUPPORT EACH VALVE BOX—// WITH (4) BRICKS, TYP. NOTES: 1. PROVIDE ONE QUICK COUPLER AT P.O.C. AND ELSEWHERE AS SHOWN ON PLAN. 2. INSURE POSITIVE DRAINAGE FROM P.O.C. COMPONENTS. PROVIDE DAYLIGHT DRAIN AS NECESSARY. 3. PROVIDE SIZE & QUANTITY OF VALVE BOXES AS NECESSARY TO ACCOMMODATE ALL COMPONENTS. POINT OF CONNECTION - WITH DOUBLE CHECK VALVE P-CA-10 \vj 1 1/2" = 1'-0" RECORD DRAWINGS EB 2/28/25 SURVEYED: DESIGNED: DRAWN: EB/AM CHECKED: N N0. REVISION BY DATE APPR APPROVED: AR SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY P-CA-30 VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM SPECIFIED 10" ROUND VALVE BOX, INSTALL FLUSH WITH FINISH GRADE QUICK COUPLER VALVE C TY OF WO RENTON Planning/Building/Public Works Dept. SHRUB OR LAWN HEAD, TOP FLUSH W/ FINISH GRADE. ADJUST TO ACCOUNT FOR SETTLING OF TOPSOIL OR MULCH 91010ywe] :L1112 NEW (2) TH x TH SCH. 40 ELLS W/ 2" x 3/4" SCH. 80 NIPPLE OR (2) MARLEX STREET ELLS W/O NIPPLE NEW 12" x 3/4" SCH. 80 NIPPLE NEW OR EXISTING SCH. 40 TH x TH ELL, OR MARLEX STREET ELL NEW OR EXISTING PVC TEE OR ELL, BUSHING AS REQUIRED, REFER TO PLANS FOR LOCATIONS OF EXISTING/NEW ACCEPTABLE 3/4" PRE -FABRICATED SWING JOINTS: HUNTER SJ, RAIN BIRD SA, OR APPROVED EQUAL NEW OR EXISTING PVC TEE OR ELL, WITH BUSHING AS REQUIRED NEW PVC TH SCH. 80 NIPPLE, 3" LONG NEW PVC THx TH 90° ELL NEW PVC TH SCH. 80 NIPPLE, 8" LONG P-CA-08 OF W AS for `N���ff1777J RA MsM 1 G coP Q 1430 NE 65th Street 11 Seattle, WA 98115 92� 93s 2r. S EXP.61 t: 206-322-1732 cq P E A RG fora.land IN COMPLIANCE WITH CITY OF RENTON STANDARDS CASCADE ELEMENTARY SCHOOL FIELD IMPROVEMENTS IRRIGATION DETAILS DATE: 04/19/24 FIELDBOOK: PAGE: DRAWING NO: L3.04 SHEET: r1 2 OF: 40 0 Ill Nt O O N , u R-429328