HomeMy WebLinkAboutConcrete Compressive Strength Test.Southport Park Avenue Extension (T).2021-12-07.M7211711.0004ARev1Report Number: Service Date: Report Date: Task: Client Renton, WA 1095 Lake Washington Blvd. North Southport Park Avenue Extension (T)SECO Development Attn: Accounts Payable 1133 Lake Washington Blvd N Ste 90 Renton, WA 98056-6489 425-742-9360 Lynnwood, WA 98036-6365 20225 Cedar Valley Rd Ste 110 M7211711.0004A 12/07/21 12/14/21 Revision 1 - 7-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: M7211711 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 0442A Miles Material Information 0654 1137 Plant: Ticket No.: 202 267649 Field Test Data Test Air Content (%): Result Specification 5 4.6 60 42 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:12/07/21 0800 Marco Martinez Cloudy 10.25 of 37 10.25 0 0 Sample Location: Placement Method:truck chute Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Final half of the west driveway ramp and 3 locations of sidewalk sections on the South and on the West for the Southport Park Ave Extension Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Max Strength Comp Frac No.ID Spec Received Tested (days)Type(in)(sq in)(lbs)(psi) Tested ByCond. 1 1 3.99 12.5 12/08/21 12/14/21 7 49,400 3 3,950 APIGood 1 2 12/08/21 01/04/22 28 1 3 12/08/21 01/04/22 28 1 4 12/08/21 01/04/22 28 Initial Cure:Final Cure:Outside Plastic Lids Moist Room Sample Description:4-inch diameter cylinders Comments:Not tested for plastic unit weight. Samples Made By: Mayes/Terracon Special Inspections / Materials TestingServices: Reported To: Contractor: Report Distribution: (1) City of Renton WA, Michael Sippo (1) Mayes Testing Engineers, Inc, Belinda Rix (1) Mayes Testing Engineers, Inc, Mark Gordon (1) SECO Development, Derek Janke Mark Gordon Department Manager III SECO Development Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Mayes/Terracon Rep.: Marco Martinez The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6