Loading...
HomeMy WebLinkAboutPRE24-000162_Staff_Comments_240627_v1DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 |www.rentonwa.gov PREAPPLICATION MEETING FOR 3901 Park Ave N 3901 Park Ave N (APN 3342700405) PRE24-000162 June 27, 2024 Contact Information: Planner: Andrew Van Gordon, 425-430-7286, avangordon@rentonwa.gov Public Works Plan Reviewer: Michael Sippo, 425-430-7298, msippo@rentonwa.gov Fire Prevention Reviewer: Corey Thomas, 425.276.9582, cthomas@RentonRFA.org Building Department Reviewer: Rob Shuey, 206.550.8523, rshuey@rentonwa.gov Please retain this packet throughout the course of your project as a reference. Consider giving copies to engineers, architects, and contractors who will work on the project. You will need to submit an PDF copy of this packet when you apply for land use and/or environmental permits. When the project application is ready for submittal, you may email the project planner to start the prescreen process. Similarly, you may contact the assigned planner if there are any questions regarding submittal requirements. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services Director, Development Engineering Director, Department of Community & Economic Development Administrator, Public Works Administrator and City Council). M E M O R A N D U M DATE: June 11, 2024 TO: Andrew Van Gordon, Senior Planner FROM: Corey Thomas, Lead Plans Review Inspector SUBJECT: Lay Short Plat 1. The fire flow requirements for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. One existing fire hydrant will meet the minimum requirements. 2. The fire impact fees are currently applicable at the rate of $421.98 per single family unit. This fee is paid at building permit issuance. Credit will be granted for any existing homes that are removed or retained. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Dead end streets that exceed 150-feet in length require an approved turnaround. Dead ends up to 300-feet long are allowed to use hammerhead type turnarounds. Dead end streets that are over 300-feet long are required to have a full 90-foot diameter cul-de-sac. The proposed new dead-end street is over 300-feet long so that a full cul-de-sac turnaround applies in this case. A variance to use a hammerhead type turnaround may be applied for with the condition that all new homes shall be equipped with approved residential fire sprinkler systems. DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: June 25, 2024 TO: Andrew Van Gordan, Planning FROM: Michael Sippo, Development Engineering SUBJECT: Lay Short Plat 3901 Park Avenue N PRE24-000162 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non- binding and may be subject to modification and/or concurrence by official city decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel 3342700405. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. EXISTING SITE CONDITIONS Water Water service is provided by the City of Renton. It is in the Kennydale 308 Pressure Zone. There is an existing 12-inch water main in Park Ave N that can deliver 3,400 gallons per minute. The approximate static water pressure is 81 psi at a ground elevation of 122’. There is an existing 8-inch water main in Wells Ave N that can deliver approximately 1,200 gallons per minute. The approximate static water pressure is 95 psi at a ground elevation of 88’. There is an existing ¾-inch domestic water service and ¾-inch water meter to the existing single-family residence (3901 Park Ave N) on the subject property. Sewer Sewer service is provided by the City of Renton. There is existing 8-inch diameter sewer main on Park Avenue N and Wells Ave N. Storm This site contains steep slopes (regulated) and landslide hazard areas. The topography slopes moderately from southeast to northwest. There is a conveyance system on Park Avenue N and Wells Ave N. Streets The proposed development fronts Park Avenue N along the east property line. Park Avenue N is classified as a Collector Arterial. Existing right-of-way (ROW) width in Park Avenue NE is approximately 50 feet. Lay Short Plat - PRE24-000162 June 25, 2024 Page 2 of 5 CODE REQUIREMENTS WATER Based on the review of project information submitted for the pre-application meeting, Renton Regional Fire Authority has determined that the preliminary fire flow demand for the proposed development is 1,000 gpm. The following developer’s installed water main improvements will be required to provide domestic and fire protection service to the development including but not limited to: 1. Extension of approximately 140 linear feet of 8-inch water main from the existing 8-inch dead end water main in Wells Ave N at the north property line west to the existing 8-inch dead end main in 3836 Lake Washington Blvd N at the west property line. A conceptual utility plan is attached. 2. Extension of approximately 110 linear feet of 8-inch water main from the existing 8-inch dead end water main in Wells Ave N at the north property line south to the property extents and the terminus of new Wells Ave N. 3. A 15-foot utility easement will be required for the new water mains, hydrants, and water meters within private property. 4. Installation of additional fire hydrant as required by the Fire Authority, if the proposed residences on the new lots exceed 3,600 sf and if existing hydrants are located too far from proposed buildings. 5. Installation of a new 1-inch water service and meter for Lots 2-4. The existing 3/4" water service and meter for Lot 1 can remain if the home on Lot 1 remains. 6. A conceptual utility plan will be required as part of the land use application for the subject development. 7. Civil plans for the water main improvements will be required and must be prepared by a Professional Engineer registered in the State of Washington. Please refer to City of Renton General Design and Construction Standards for Water Main Extensions as shown in Appendix K of the City’s 2021 Water System Plan. 8. Adequate separation between utilities is required. Minimum separation between water and non-potable water utilities is 10-feet horizontal and 1.5-feet vertical. 9. The development is subject to applicable water system development charges (SDC’s) and meter installation fees based on the number and size of the meters for domestic uses and for fire sprinkler use. The development is also subject to fees for water connections, cut and caps, and purity tests. Current fees can be found in the 2024 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. a. The SDC fee for water is based on the size of the new domestic water to serve the project. The 2024 water fees are $4,850.00 per 1-inch meter. b. Water service installation charges for each proposed domestic water service is applicable. Water Service installation fee is $2,875.00* per 1-inch service line. Fee is payable at permit issuance. c. Drop-in meter fee is $460.00* per 1-inch meter, $750.00 per 1-1/2-inch meter, and $950.00 per 2-inch meter. Meters larger than 2-inches are set by the contractor and a processing fee of $220 is required. Fee is payable at permit issuance. d. A credit for the water system redevelopment fee will be issued for the existing water service to be cut can capped as part of the project. e. Final determination of applicable fees will be made after the water meter size has been determined. SDC fees are assessed and payable at permit issuance. Lay Short Plat - PRE24-000162 June 25, 2024 Page 3 of 5 SEWER 1. A sewer main extension will be required to serve the proposed project. 2. A 15-foot utility easement will be required for the new sewer mains and manholes within the property. 3. The developer will need to show how they propose to serve the new development with sanitary sewer service to each of the units. 4. A separate side sewer will be required for each new lot. All new side sewers shall be a minimum of 6”. All side sewers shall flow by gravity to the main at a minimum slope of 2%. 5. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. Current fees can be found in the 2024 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of construction permit issuance. a. The 2024 Wastewater fees are $3,650.00 per 1-inch meter. SURFACE WATER 1. A drainage report complying with the current 2022 Renton Surface Water Design Manual (RSWDM) will be required. Based on the City’s flow control map, the site falls within the City’s Peak Rate Flow Control Standard (Matching Existing Conditions). The site falls within the May Creek and East Lake Washington Drainage Basins. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. All stormwater improvements as per the drainage review along with stormwater improvements in the frontage are required to be provided by the developer. a. Note: Under the 2022 RSWDM stormwater requirements, on-site BMP sizing credits for modeling credits can no longer be used for privately maintained on-site BMPs, with the exception of full dispersion and full infiltration BMPs. 2. Storm drainage improvements along all public street frontages are required to conform to the City’s street and stormwater conveyance standards. Any new storm drain installed on or off-site shall be designed and sized in accordance with standards found in Chapter 4 of the 2022 RSWDM and shall account for the total upstream tributary area, assuming developed conditions for onsite tributary areas and existing conditions for any offsite tributary areas. 3. Maintenance access is required for any proposed stormwater tracts and shall be designed and installed in accordance with the City adopted SWDM. 4. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide basic water quality treatment. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 5. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2022 RSWDM. A preliminary drainage plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. Lay Short Plat - PRE24-000162 June 25, 2024 Page 4 of 5 6. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 7. Erosion control measures to meet the City requirements shall be provided. 8. The current City of Renton Surface Water Standard Plans that shall be used in all drainage submittals are available online at the City of Renton website. 9. The 2022 Surface water system development fee is $2,300 per new single-family lot. Fees that are current will be charged at the time of permit issuance. TRANSPORTATION 1. The proposed development fronts Park Avenue N along the east property line. Park Avenue N is classified as a Collector Arterial. Existing right-of-way (ROW) width in Park Avenue NE is approximately 50 feet. To meet the City’s complete street standards for collector arterial streets, minimum right of way width is 83 feet. a. The Transportation Division has no plans to widen Park Avenue N at this time. Development Engineering would support a modification request by the Applicant to provide the following modified street improvements on Park Avenue N: maintain a pavement width of 36 feet, install a 0.5-foot curb (match existing curb location directly north of project property), an 8-foot planting strip, a 5-foot sidewalk, 2 feet of clear space at back of walk, street trees and storm drainage improvements. Dedication to accommodate these improvements will be required, pending field survey. 2. The proposed development fronts Wells Ave N at a portion of the north property line. Wells Ave N is classified as a Limited Access Residential Street. Existing right-of-way (ROW) width in Wells Ave N is 47 feet as constructed as a portion of the Senza Lakeview subdivision project. a. In order to match the connection to Wells Ave N to the north the project will be required to construct a 47 foot right of way from the north property line to the south property line consisting of (2) 10’ travel lanes, (2) 6” curbs, (2) 8’ planters, and (2) 5’ sidewalks. The separate tract as shown on the preliminary plans prohibiting future connection to N 38th St will not be allowed. 3. Street grades shall not exceed 15 percent. 4. A hammer-head turnaround meeting Renton Regional Fire Authority requirements as shown on the preliminary plans is required. Since no future street connection to the west is feasible, the hammerhead will need to utilize a curb cut driveway across the proposed sidewalk versus the preliminary plans showing curb returns and a crosswalk. The hammerhead will be signed with “no parking” signs. 5. ADA access ramps shall be installed at all street crossings. Ramps shall be shown at each intersection. Ramps shall be oriented to provide direct pedestrian crossings. 6. Refer to City code 4-4-080 regarding driveway regulations: a. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage. Lay Short Plat - PRE24-000162 June 25, 2024 Page 5 of 5 b. The maximum width of a single loaded garage driveway is 9-feet and the maximum width of a double loaded garage driveway is 16-feet. If a garage is not present, the maximum driveway width is 16-feet. c. Driveways shall not be closer than 5-feet to any property line. 7. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 8. The transportation impact fee is based on the type of land use. For a single-family homes, the 2024 transportation impact fee is $11,485.67 per lot. Transportation impact fees are subject to change based on the year the building permit is applied for. GENERAL COMMENTS 1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property frontage or within the site must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 2. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements: a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 3. All civil construction permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 4. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on separate sheets. 5. Additional Building Permit Applications will be required for the following: a. Any retaining walls that exceed 4 feet in height, as defined by RMC 4-4-040. b. Detention vaults for storm water flow control. c. Demo of any existing structures on the project site(s). 6. Fees quoted in this document reflect the fees applicable in the year 2024 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. 106116.418SSMH115.917WVL116.129WFHMSN118116.936WVL121125.221SSMH128125.198SSMH129124.950SDCB148122.111PWP150121.175SDCB152118.863TRMP177122.149WMT179122.765GRGS187120.745MMB191106.236TRMP211105.461GRGS248104.552GRGS26189.373TRFR26292.183TRFR26785.171TRFR27387.984GRGS27488.486GRGS27589.459GRGS27692.936GRGS27792.289GRGS27988.672GRGS28091.420GRGS28194.851GRGS28296.124GRGS28397.167GRGS28498.736GRGS285100.446GRGS28699.675GRGS28796.121GRGS28894.693GRGS28992.608GRGS29083.657GRGS29184.118GRGS29286.186GRGS29390.118GRGS29489.950GRGS29590.138GRGS296103.846GRGSGRAPHIC SCALE01020401 INCH = 20 FT.1-INCH WATER METER FOREACH LOT IN RIGHT OF WAYOR EASEMENT. LOCATE INPLANTER STRIP ANDOUTSIDE OF DRIVEWAY (TYP)CONNECTTO EX. 8" WMNEW 8" DI WM15.0 ft WATER UTILITY EASEMENTCONNECT TOEX. 8" WMEX. 8" DI WMCOR PROJECT FILEWTR2702317EX. 8" DI WMCOR PROJECTFILE WTR2703934EX. 12" DI WMCOR PROJECTFILE WTR2702305EXISTING 3/4" METERCAN REMAIN IFEXISTING HOMEREMAINS.Ian Fitz-JamesWater Utility07/07/21 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: June 27, 2024 TO: Pre-Application File No. 24-000162 FROM: Andrew Van Gordon, Associate Planner SUBJECT: 3901 Park Ave N – 3901 Park Ave N (APN 3342700405) General: We have completed a preliminary review of the pre-application for the above- referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision- makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, Development Services Director, Development Engineering Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are available online at https://www.codepublishing.com/WA/Renton. Project Proposal: The applicant proposes to subdivide 3901 Park Ave N (APN 3342700405) into four (4) residential lots. The subdivision is for the benefit of detached dwellings. The property has street frontage along Park Ave N to the east and Wells Ave N to the north. The lot is located within the Residential-6 (R-6) zone. The site area is approximately 42,200 square feet (0.96 acres). Access to Lot 1 is proposed via the existing driveway from Park Ave N; individual driveway access from an extension of Wells Ave N is proposed for Lot 2 through 4. Current Use: The project area is currently improved with a detached dwelling and associated detached accessory structures. The applicant proposes to keep existing structures and place them on Lot 1. Per City of Renton (COR) Maps, the site is encumbered with a Moderate Landslide Hazard area and sensitive slopes. 1. Zoning /Land Use Designation, and Overlays: The subject property is located within the Residential-6 (R-6) zoning classification. The Residential Medium Density (RMD) Land Use designation is intended to implement the R-6 zone. The R-6 zone is established for single family dwellings and is intended to implement the Residential Medium Density Comprehensive Plan designation. The R-6 zone allows a range of three (3) to six (6) dwelling units per net acre. Development in the R-6 zone is intended to be single family residential at moderate density. Detached dwellings are permitted within the R-6 zone. 2. Development Standards: The project would be subject to RMC 4-2-110A, Development Standards for Residential Zoning Designations effective at the time of complete application 3901 Park Ave N Page 2 of 7 June 27, 2024 (noted as “R-6 standards” herein). ADUs would be subject to RMC 4-2-110C, Development Standards for Residential Development (Accessory Dwelling Units). Density – The area of public rights-of-way, legally recorded private access easements and critical areas (i.e. very high landslide hazard areas, protected slopes (except evaluate on a case-by-case basis those protected slopes created by previous development, wetlands, Class 1 to 4 streams and lakes or floodways) would be deducted from the gross site area to determine the “net” site area prior to calculating density. In order to calculate the proposed density of the project, any area of public road, private driveway/easement, and/or critical area dedication must be known. All fractions which result from net density calculations shall be truncated at two (2) numbers past the decimal (e.g., 4.5678 becomes 4.56). Calculations for minimum or maximum density that result in a fraction that is 0.50 or greater shall be rounded up to the nearest whole number. Those density calculations resulting in a fraction that is less than 0.50 shall be rounded down to the nearest whole number. The R-6 zone has a maximum net density of six (6) dwelling units per acre with a minimum of three (3) dwelling units per acre. Based on the approximate gross land area of 0.96 acres, the four (4) lot proposal arrives at a gross density of approximately 4.16 du/ac (4 lots / 0.96 gross acres = 4.16 du/ac). A density worksheet was not included with the pre-application submittal materials; therefore, staff was unable to verify compliance with the density requirements. The gross density would result in 4.16 du/ac. The applicant would be required to demonstrate compliance with the net density requirements of the zone at the time of formal application. A density worksheet would be required with the land use application. Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-6 zone is 7,000 square feet for parcels being subdivided. Minimum lot width is 60 feet (60’); minimum lot width for corner lots is 70 feet (80’); minimum lot depth is 90 feet (90’). In order to ensure compliance with Tier 1 requirements for Tree Preservation Priority, pursuant to RMC 4-4- 130H.2.a, lot size and lot dimensions of the zone may be decreased by a maximum of 10 percent (10%), provided the applicant can demonstrate to the Administrator’s satisfaction that the reduction is necessary to ensure the preservation of all significant trees, as defined in RMC 4-11-200, required for retention within dedicated tract(s), pursuant to RMC 4-4- 130H.1.a, Minimum Tree Retention Requirements. For short plats of parcels smaller than one (1) acre, one parcel may be allowed to be smaller than the required minimum lot size. If all other parcels meet the required minimum R-6 lot size standard, one (1) parcel may be allowed to reduce the minimum lot size to 6,250 square feet. The applicant’s narrative and the applicant’s drawings do not match in terms of lot size. The narrative indicates that the smallest lot will be Lot 2 at 9,513 square feet. The drawings indicate that the smallest lot will be Lot 2 at 5,842 square feet. Further, the narrative indicates the average lot size needs to be 7,000 square feet; the minimum lot size is required to be 7,000 square feet for each lot unless one of the specific allowances to reduce the lot size is permitted. As proposed, Lot 2 does not meet minimum lot size requirements. At 6,288 square feet Lot 3 would not meet minimum lot size requirements as all of the other lots are not at least 7,000 square feet. Minimum lot width for interior lots is 60 feet (60’). Lot 2 and Lot 3 both appear to be under this allowance. To deviate from width standards would require review and approval through a variance. Compliance with minimum lot size, width and depth standards would be verified at the time of land use application. 3901 Park Ave N Page 3 of 7 June 27, 2024 Building Standards – The R-6 standards allow a maximum building coverage of 40 percent (40%) of the lot area. The maximum impervious coverage in the R-6 zone is 55 percent (55%). The maximum wall plate height is restricted to 24 feet (24’), and the buildings shall be not more than two (2) stories. Roofs with a pitch equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum wall plate height; common rooftop features, such as chimneys, may project an additional four vertical feet (4’) from the roof surface. Non- exempt vertical projections (e.g., decks, railings, etc.) shall not extend above the maximum wall plate height unless the projection is stepped back one-and-a-half horizontal feet (1.5’) from each façade for each one vertical foot (1’) above the maximum wall plate height. The maximum wall plate height for detached accessory structures is 12 feet (12’) and the total floor area must be less than that of the primary structure. Accessory structures are also included in building lot coverage calculations. Existing development would need to demonstrate compliance with maximum building coverage and impervious surface requirements at the time of land use permit. New development would need to comply with the maximum building coverage, impervious surface requirements, and building height regulations of the zone at the time of building permit review. Setbacks – Setbacks are the minimum required distance between the building footprint and the property line. The required setbacks for the R-6 zone are: Front yard: 25 feet (25’); Secondary front yard (applies to corner lots): 25 feet (25’); Rear yard: 25 feet (25’); Side yard: combined 15 feet (15’) with not less than five feet (5’) on either side. Existing development would need to demonstrate compliance with setbacks at the time of land use permit review. Of note, it appears that the rear yard setback is shown as being 10 feet (10’) on the drawings which is incorrect. Compliance with required setbacks for new development would be verified at the time of building permit application. 3. Residential Design and Open Space Standards: Future single-family building permits would be subject to the RMC 4-2-115, Residential Design and Open Space Standards. Requirements related to garages, entries, modulation, windows/doors, scale, bulk, and character, roof forms, eaves, architectural detailing, and materials/color should be reviewed in their entity prior to submitting permit applications. Future ADU building permits would be subject to RMC 4-2-116, Accessory Dwelling Unit Residential Design Standards. Requirements related to application standards should be reviewed in their entirety prior to submitting permit applications. Compliance with building design requirements would be verified at the time of building permit review. 4. Landscaping: With the exception of critical areas, all portions of the development area not covered by structures, required parking, access, circulation or service areas, must be landscaped with native, drought-resistant vegetative cover. The minimum on-site landscape width required along street frontages is 10 feet and shall contain a mixture of trees, shrubs, and landscaping. Street trees in the ROW planter would also be required. Landscaping may include hardscape such as decorative paving, rock outcroppings, fountains, plant containers, etc. Minimum planting strip widths between the curb and sidewalk are established according to the street development standards of RMC 4-6-060, Street Standards. Street trees and, at a minimum, groundcover are to be located in this area when present. Street trees shall be 3901 Park Ave N Page 4 of 7 June 27, 2024 planted in the center of the planting strip between the curb and the sidewalk at the following intervals; provided, that, where right-of-way is constrained, irregular intervals and slight increases or decreases may be permitted or required. Additionally, trees shall be planted in locations that meet required spacing distances from facilities located in the right-of-way including, but not limited to, underground utilities, streetlights, utility poles, traffic signs, fire hydrants, and driveways; such spacing standards are identified in the City’s Approved Tree List. Generally, the following spacing is required: i. Small-sized maturing trees: thirty feet (30') on center; ii. Medium-sized maturing trees: forty feet (40') on center; and iii. Large-sized maturing trees: fifty feet (50') on center. A conceptual landscape plan shall be provided with the land use application as prepared by a licensed Landscape Architect, a certified nurseryman or other certified professional. Please be aware that frontage improvements will be required. Storm drainage facilities are required to comply with the minimum 15-foot perimeter landscaping strip on the outside of the fence unless otherwise determined through the site plan review or subdivision review process. Please refer to landscape regulations RMC 4-4-070 for further general and specific landscape requirements. 5. Significant Tree Retention: A review of COR Maps appears to show that there are mature trees on the site. When significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are proposed to be removed, a tree inventory and a tree retention plan along with an arborist report, tree retention plan and tree retention worksheet shall be provided with the formal land use application as defined in RMC 4-8-120. The tree retention plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130, Tree Retention and Land Clearing Regulations for further general and specific tree retention and land clearing requirements In addition to retaining a minimum of 30% of existing significant trees, each new lot would be required to provide a minimum tree density of 30 tree credits per net acre. Tree credits encourage retention of existing significant trees with larger trees being worth more tree credits. TREE SIZE TREE CREDITS New small species tree 0.25 New medium species tree 1 New large species tree 2 Preserved tree 6 – 9 caliper inches 4 Preserved tree 10 – 12 caliper inches 5 Preserved tree 12 – 15 caliper inches 6 Preserved tree 16 – 18 caliper inches 7 Preserved tree 19 – 21 caliper inches 8 3901 Park Ave N Page 5 of 7 June 27, 2024 TREE SIZE TREE CREDITS Preserved tree 22 – 24 caliper inches 9 Preserved tree 25 – 28 caliper inches 10 Preserved tree 29 – 32 caliper inches 11 Preserved tree 33 – 36 caliper inches 12 Preserved tree 37 caliper inches and greater 13 Protected trees within a subdivision shall be retained in the order of priority listed in RMC 4-4-130H.2. Protection of trees or groves by placement within a dedicated tract (Tier 1) is the highest priority. Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting properties from strong winds, which could otherwise allow such sheltered trees to be blown down if removed. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non-native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. The Administrator may require independent review of any land use application that involves tree removal and land clearing at the City's discretion. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4- 130H.1.e can be met. Tree retention standards shall be applied to the developable area, as defined in RMC 4-11- 040, Definitions D, of a property. A formal tree retention plan and tree retention worksheet prepared by an arborist or landscape architect would be reviewed at the time of the land use application. 6. Fences/Retaining Walls: If the applicant intends to install any fences or retaining walls as part of this project, the location must be designated on the landscape plan and grading plan with top of wall and bottom of wall elevations. A fence and/or wall detail should also be included on the plan. A retaining wall that is 4 feet or taller, as measured by the vertical distance from the bottom of the footing to the finish grade at the top of the wall requires a building permit. The maximum height of any fence or retaining wall is 72-inches subject to further height limitations in setbacks and clear vision areas noted in RMC 4-4-040D. A fence shall not be 3901 Park Ave N Page 6 of 7 June 27, 2024 constructed on top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the allowed height of a standalone fence. For more information about fences and retaining walls refer to RMC 4-4-040. 7. Access/Driveways/Parking: Access is proposed via individual driveways from Park Ave N and Wells Ave N. Each lot is required to accommodate off street parking for a minimum of two (2) vehicles for the detached dwelling. The maximum width of single loaded garage driveways shall not exceed nine feet (9’) and double loaded garage driveways shall not exceed 16 feet. Maximum driveway slopes shall not exceed 15 percent; provided, that driveways exceeding eight percent (8%) shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage/residence or crossing any public sidewalk. Driveways shall not be closer than five feet (5’) to any property line except as allowed per RMC 4-4-080I.9, Joint Use Driveways As shown the driveways would not be meeting requirements as they are greater than 16 feet (16’) in width within the right-of-way and are within five feet (5’) of the property lines. Of note, fire may support a hammerhead type turnaround with the condition that all new homes shall be equipped with approved residential fire sprinkler systems. Compliance with access and driveway requirements would be verified at the time of land use application. 8. Critical Areas: Per COR Maps, the site is encumbered with a Moderate Landslide Hazard area and sensitive slopes. Due to the presence of geological hazards, a geotechnical study may be required at the time of land use application. It is the applicant’s responsibility to ascertain whether environmental concerns are present on the site during site development or building construction. 9. Environmental Review: Short Plats are generally exempt from State Environmental Policy Act (SEPA) review. However, the project may be subject to Environmental Review, in accordance with RMC 4-9-070 H.3., if it is determined that critical areas are located on the property. 10. Permit Requirements: The proposal would require administrative short plat approval. The application would be reviewed within an estimated time frame of eight (8) weeks. The 2024 fees would total $6,384.00 ($6,080.00 Preliminary Short Plat + $304.00 Technology Fee (5%) = $6,384.00). Each modification request is $290.00. A 5% technology fee added to the total cost of the reviews would also be assessed at the time of land use application. All fees are subject to change. Detailed information regarding the land use permit application submittal requirements can be found on the Short Plat Submittal Requirements checklist. Other informational applications and handouts can be found on the City’s Digital Records Library. The City requires electronic plan submittal for all applications. Please refer to the City’s Electronic File Standards. A Final Short Plat application, and its associated fee, will be required following construction of the subdivision’s infrastructure. 11. Waivers of Submittal Requirements: The submittal checklist is not an exhaustive list of submittal requirements and may be modified in cases where additional information is required to complete the review of an application. In addition, non-applicable submittal requirements may be waived. The applicant should contact the assigned Project Manager if there are any questions regarding submittal requirements. 3901 Park Ave N Page 7 of 7 June 27, 2024 12. Public Information Sign: Public Information Signs are required for all Type II and Type III Land Use Permits as classified by RMC 4-8-080. Public Information Signs are intended to inform the public of potential land development, specific permits/actions being considered by the City, and to facilitate timely and effective public participation in the review process. The applicant must follow the specifications provided in the public information sign handout. The applicant is solely responsible for the construction, installation, maintenance, removal, and any costs associated with the sign. 13. Impact Fees: In addition to the applicable building and construction fees, impact fees would be required. Fees change periodically and the fees in effect at the time of building permit issuance would apply. For informational purposes, the 2024 impact fees are as follows: • A Fire impact fee assessed at $421.98 per each new detached dwelling unit. • A transportation impact fee assessed at $11,485.67 per each new detached dwelling unit. • A Renton School District Impact Fee assessed at $2,161.00 per each new detached dwelling unit (plus an additional 5% processing fee). • Parks Impact Fee currently assessed at $3,276.44 per each new detached dwelling unit. Most fees for new ADUs are waived as of the adoption date of Resolution 4422. A handout listing all of the City’s Development related fees is available for your review at https://edocs.rentonwa.gov/Documents/Browse.aspx?id=8217302&dbid=0&repo=CityofRe nton 14. Next Steps: When the formal application materials are complete, the applicant shall have the materials pre-screened prior to submitting the complete application package. Please contact Andrew Van Gordon, Associate Planner, at 425-430-7286 or avangordon@rentonwa.gov to submit prescreen materials and subsequent land use application. 15. Expiration: Upon approval, the Short Plat is valid for five years with a possible one-year extension (RMC 4-7-070M). It is the applicant’s responsibility to monitor the expiration dates. CA858687888990919293949596979899100101102 10310410 5 108100 1009210 8 10 9 110 113 114 11 5 116 117 118 119 120 121 122 123 12412 4 12 3 1 2 2 1211 1 3 1 1 2 11 410510 5 120 119 11 6 117 118 122 121 N88°45'47"W400.00'888786858483PARK AVENUE N.LOT 112,974.13 SFLOT 25842.82 SFLOT 36288.39 SFLOT 411421.22 SFTRACT A940.00 SFROW4184.73 SFFG 122.96GRAPHIC SCALETITLE SHEETBOUNDARY AND TOPODRAINAGE CONTROL PLAN (SWWP)GRADING AND DRAINAGE PLANROAD AND STORM PROFILESPARK AVENUE PLAN AND PROFILEUTILITY PLAN (WATER AND SEWER)C1.C2.C3.C4.C5.C6.C7.LEGENDSW 1/4, SEC 32, TWP 24N, RNG 5E, W.M.ENGINEER/SURVEYOR:O'BUNCO ENGINEERINGATTN: SAM OBUNIKE1042 WEST JAMES STREETSUITE 103, KENT WA 98032PO BOX 1307 97381PHONE:(206)228-0881Callbefore youD1-800-424-5555g.O'BUNCOENGINEERINGOFUSHU LWELBO.ATOMASTATESPRNEGIIOSAFESRSEEKININGTONEREREDLENGIN NOTE:AAANNNNNNNPROJECT_NAME CITY OFRENTONSHEET_NUMBER LUA:C:A-NNNNNNNIN COMPLIANCE WITH CITY OF RENTON STANDARDSPR:AMY LAY SHORT PLATPRELIMINARY 3 LOT SHORT PLATCOVER SHEETSTEVE WONG SHORT PLAT SHEET INDEXSURVEYOR:PROPERTY OWNER:TAX PARCEL NUMBER:PROJECT ADDRESS:ZONING:JURISDICTION:PARCEL ACREAGE:O'BUNCO ENGINEERING1042 West James StreetSuite 103Kent, WA 98032AMY LAY3901 PARK AVE NRENTON, WA 98056334270-04053901 PARK AVE NR-6CITY OF RENTON41,770 SF FTOWNER:AMY LAY3901 PARK AVE NRENTON, WA 98056THE EAST 400 FT OF TRACT 86, C.D.HILLMANS LAKE WASHINGTONGARDEN OF EDEN ADDITION TO SEATTLE NO. 2 ACCORDING TO THEPLAT THEREOF RECORDED IN VOLUME 11 OF PLATS, PAGE 64, IN KINGCOUNTYLEGALBASIS OF BEARING: BASED ON FOUND MONUMENTS ON THE CENTERLINE OF PARK AVE N.BASIS OF BEARINGNAVD 88 DATUM.PER CITY OF RENTON SURVEY CONTROL POINT ID:RENT-526ELEVATION=182.09 FEETVERTICAL DATUM1. FIRST AMERICAN TITLE INSURANCE COMPANY PROVIDED FOR LANDDESCRIPTION AND REVELATION OF EASEMENTS2. THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED BASEDON OBSERVABLE SURFACE EVIDENCE. THE SURVEYOR MAKES NOGUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISEALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.SURVEYOR'S NOTESPROJECT INFORMATION