HomeMy WebLinkAboutStamped - C4.08 - UTILITY PLANLegendPROPERTY LINESANITARY SEWERSANITARY MH/CO8" SS @ xx%STORM DRAINAGE PIPEYD/CO/CB/CB 2/MH8" SD @ xx%FH/FDC/PIV/VALVEWATER VAULT/METERFHFDCPIVWVWATER MAIN12" DI WDo not use BlockEdit, Use LEGEND to editSITE/ STREET LIGHTING23 LF 6" DI CL5280 LF 4" DI CL528'175 LF 12" DI CL52SDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSD
x
SD
x
SDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSDxSD
x
SD
x
SDxSDx(1) 12"x6" TEE (FL)(1) 12" GATE VALVE (FLxMJ)(1) 12" FLxMJ ADAPTER(1) 6" GATE VALVE (FLxMJ)FIRE HYDRANT PER CORSTD. PLAN 310.1STA 10+16SS#05 SSMH - 48"RIM=20.56IE=14.77 8"(IN)NWIE=14.97 6"(IN)WIE=14.67 8"(OUT)EPER COR STD. PLAN400.1 AND 401.2(PRIVATE)231 LF 8" PVC @ 0.8%(1) 12"x6" TEE (FL)(1) 12" GATE VALVE (FLxMJ)(1) 12" FLxMJ ADAPTER(1) 6" GATE VALVE (FLxMJ)FIRE HYDRANT PER CORSTD. PLAN 310.1STA 11+17101 LF 12" DI CL523" WATER METER, PERCOR STD DTL 320.411 LF 12" DI CL525 LF 12" DI CL5229 LF 4" DI CL52(2) 3/4" WATER METER,PER COR STD DTL 320.17 LF 4"DI CL5210 LF 4" DI CL529 LF 6" DI CL52(1) 12" POLY PIG STATION ATEND OF WATER MAIN PERCOR STD. PLAN 300.7STA 10+00(1) 4" 90° BEND (MJ)FFE=21.75(1) 12"x4" TEE (FL)(1) 4" GATE VALVE (FLxMJ)THRUST BLOCK PER CORSTD. PLAN 330.1STA 10+1115' WATEREASEMENT, TYP10+0011+0012+0010+5011+50PROVIDE (2) 3/4" RPBA,PER COR STD DTL 360.1(PRIVATE)(PRIVATE)SS#05A SSCORIM=21.50IE=18.14 8"(IN)WIE=18.14 8"(OUT)SECLEANOUT(PRIVATE)88 LF 8" PVC @ 3.9%25 LF 8" PVC @ 1.0%(PRIVATE)31 LF 4" DI CL52(1) 4" 45° BEND (MJ)8 LF 4" DI CL52(1) 4" 45° BEND (MJ)SUMP PUMP TO BE LIBERTY 287 1/2 HP SUMP PUMP(OR APPROVED EQUAL) INSTALLED IN VAULT20.6214.5714.5721.641213102174149 LF 1" POLY53 LF 6" PVC @ 4.2%5 LF 6" PVC @ 1.0%SS# 05D SSCORIM=21.50IE=17.22 6"(OUT)ECLEANOUT (PRIVATE)5 LF 8" PVC @ 3.5%(PRIVATE)(PRIVATE)(PRIVATE)SS#05C SSCORIM=21.50IE=18.58 8"(IN)WIE=18.58 8"(OUT)ECLEANOUT(PRIVATE)(PRIVATE)(PRIVATE)SS# 05E SSCORIM=21.63IE=17.55 6"(IN)SIE=17.55 6"(OUT)NCLEANOUT (PRIVATE)18 LF 1" POLY31 LF 6" PVC @ 1.0%12 LF 8" PVC @ 1.5%SS WYE CONNECTIONIE=17.22 6"(IN)SIE=17.22 6"(OUT)E01020401"=20'CONTINUED - SEE SHEET C4.11CONTINUED - SEE SHEET C4.07
CONTINUED - SEE SHEET C4.05CONTINUED - SEE SHEET C4.09801 SECOND AVENUE, SUITE 900 (206) 343-0460 SEATTLE, WA 98104 www.cplinc.com COUGHLIN LUNDEEN PORTER E N G I N E E R I N G S E I S M I C C I V I L S T R U C T U R A L 33708STATE OF WASHINGTONREGISTEREDPROFESSIONALENGINEER CORB.BYHTOMITYAWK
A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M.Call Before You Dig. 8-1-1 or 1-800-424-5555 Underground Service (USA)SEATTLE SOUNDERS FC HEADQUARTERS& TRAINING CENTERRENTON, WASHINGTONSEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER
LUA22-000357 C22005747SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER PR22-000301CITY OFRENTONTHIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CADFI
L
E
P
R
E
P
A
R
E
D
B
Y
C
O
U
G
H
L
I
N
P
O
R
T
E
R
L
U
N
D
E
E
N
A
N
D
H
A
S
BE
E
N
E
D
I
T
E
D
T
O
R
E
F
L
E
C
T
F
I
E
L
D
V
E
R
I
F
I
E
D
I
N
V
E
R
T
A
N
D
R
I
M
EL
E
V
A
T
I
O
N
S
O
F
T
H
E
S
T
O
R
M
,
S
A
N
I
T
A
R
Y
S
EW
E
R
A
N
D
W
A
T
E
RMAIN SYSTEMS. FIELD VERIFIED INVERT AND RIM ELEVATIONS
W
E
R
E
O
B
T
A
I
N
E
D
B
Y
A
P
E
X
E
N
G
I
N
E
E
R
I
N
G
L
L
C
I
N
M
A
R
C
H
2
0
2
4CONSTRUCTION RECORD DRAWINGUTILITY PLANS-423806 W-423806WTRP-27-4238WWP-27-4238
INFRASTRUCTURE ENCLOSUREASI-004JAS8/25/23WCAPRIVATE WATER AND SEWER PIPE REVISIONS6JAS11/8/23WCASUMP PUMP IN WATER METER VAULT7JAS12/14/23WCAMAINTENANCE PAD REVISIONS8JAS5/13/24WCACrossingStorm Top of Pipe=15.14Sewer Bottom of Pipe=16.871.73ft Clearance40 LF 6" PVC @1.0% (PRIVATE)3
4
.
9
9
f
t SS WYE ConnectionIE=16.82 6" (IN)SWIE=16.82 6" (OUT)ESS WYE ConnectionIE=15.96 6" (IN)WIE=15.79 8" (OUT)SE7 LF 6" PVC @12.3% (PRIVATE)CO Rim to GradeIE=16.82DEVELOPMENT ENGINEERINGnjanders 06/27/2024profile views shall be updated per planrevision at time of as-build.