HomeMy WebLinkAboutR-424805w
U
Z
w
0
CIO
W
rr
rr
H
cn
LEGEND
SIGN
SS
(�) MANHOLE
SD
0D FIRE HYDRANT
W
❑ WM WATER METER
G
N GV GAS VALVE
OHP
L-� INLET
OHT
CB (TYPE-1)
OWV WATER VALVE
❑ COL COLUMN
O GUY ANCHOR X
X
DF DOUGLAS FIR
❑ EM ELECTRIC METER
O EPP ELECTRIC POWER POLE
O RESIDENTIAL MAILBOX
SANITARY SEWER LINE
STORM DRAINAGE LINE
WATER LINE
GAS LINE
OVERHEAD POWER
OVERHEAD TELEPHONE
WOOD FENCE
VINYL FENCE
HOGWIRE FENCE
CHAIN LINK FENCE
BUILDING LINE
WALL
SDMH
RIM=297.55'
IE(S)=294.47' 8"CONC
(NUMEROUS OTHER PIPES)
EPP
Off,
0
ff
�- SE 1 /4, SW 1 /4, SEC. 9, T. 23 N., R. 5 E., W.M.
LEGAL DESCRIPTION
LOT 2, CITY OF RENTON SHORT PLAT NO. LUA18-000445, RECORDING NO.
20181113900001, RECORDS OF KING COUNTY, WASHINGTON
0
0
I
0% I PO Soot Q ONST4CTION ENTRANCE 50'x15'
PER COF 215.10 DTL
BASIS OF BEARINGS
NAD 83(2011) - WASHINGTON NORTH ZONE - PER CITY OF RENTON CONTROL
POINT NOS. 612 & 398 PER SHORT PLAT, BASED ON MONUMENTS FOUND IN
CASE, PER PLAT.
VERTICAL DATUM 8s CONTOUR INTERVAL
NAVD88 PER GNSS OBSERVATIONS, DERIVED FROM WASHINGTON STATE
REFERENCE NETWORK
2.0' CONTOUR INTERVAL ARE DERIVED FROM DIRECT FIELD OBSERVATIONS -
THE EXPECTED VERTICAL ACCURACY IS EQUAL TO 1/2 CONTOUR INTERVAL OR ±
1.0' FOR THIS PROJECT
PROJECT INFORMATION
TAX PARCEL NUMBER:
PROJECT ADDRESS:
ZONING:
JURISDICTION:
PARCEL ACREAGE
FOUND SECTION CORNER WM
PER PAINTMARKSTX. OYP � �
►O-0 FOUND 1 /4 SECTION CORNER ( ) HOUSE
° N �
O•
FOUND MONUMENT IN CASE
O►7.4 APPROX. LOC. GAS LINE, ET REBAR W/CAP,
® SET/FOUND BOUNDARY MARKER, U LS 46876
PER PAINT MARKS TYP I �22
AS DESCRIBED ( ) O FOUND REBAR W/CAP, LS
�•� SET /FOUND NAIL AS DESCRIBED 5 SET REBAR W/CAP, B&H,
i FENCE E LS 46876 130"DF FENCE END 0.15'W
'S I 1.3'N I OF PROP COR
ASPHALT SURFACE
1.5' FENCE P
FOUND REBAR/CAP a- 0 DE ATED OW 1I 0.6'S ROCKERY
CONCRETE SURFACE "PLOD", zo 1 N 88° 1 1 49 E 143.51 o.7'E
0.09'W X 0.06'N 0
ROCKERY OF PROP COR 78`9= 64.60 ______
----,
S.Y.S. FENCE END it i z ROOKE17RY
ERY
— 2.1'N O
- ��� STAGING z FENCE END
GRAVEL SURFACE W O OO OO II AREA C� 0 1.6'N G C�
O ooC ooC O I W - - - - —U-1
�
PAVER SURFACE Z Ii� �- -
00
ROCKERY
RE ROOF ELEVATION O� �O
SET REBAR W�/GAP - 18.6' ::E1.6,W
�- LS 46876 i Qp0�0
FF FINISH FLOOR ELEVATION O a ° J L2
FOUND REBAR W/CAP, WALL ° WV L� L _ _ a a a a �� ° i
CLEARING LIMIT LS 11332, X VIROP ED �I I
0.05'N X 0.02'E W o ` RESID CE ° p� LOT ROCKERY
SILT FENCE (AS PER COR 214 DTL) OF PROP COR a o a L J �? ° I
1\° � 11 �� �Co PARCEL NO. 0.8E SET REBAR W/CAP,
CONSTRUCTION ENTRANCE EPP z �` O 1 ° PARCEL N0. j �� 7227800630 LS 46876
S \ _ 720800631 7685± S.R.
® CATCH BASIN (INLET) INLET 1 / 5. EBA
PROTECTION TYP L (0.1764± ACRES)
( ) ^\ ^^RIM=295^42'�_ i V �I I 5682± S.jF. I 876 FENCE LINE
E,.
Effective Eng*meer*mgPEEC
CIVIL ENGINEERS
8627 NE 180th Street, Bothell, WA 98011
Phone: (206) 303-7639
Email: admin@effectiveenaineerinaDllc.com
SURVEYED: SCALE:
SURVEYED VERTICAL: NAVD 1988
SCALE HORIZONTAL: NAD 1983/1991
DESIGNED:
DESIGNED
DRAWN:
DRAWN i ONE INCH DATUM
CHECKED: AT FULL SCALE
CHECKED IF NOT ONE INCH
NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
APPROVED
7227800631
2900 NE 5TH PL
RENTON, WA 98056
R- 8
RENTON
5,682± S.F. (0.13± ACRES)
AS SURVEYED
10/01/2023
'D C TY OF
RENTON
Planning/Building/Public Works Dept.
A
LJ
V C N TY MAP N TS
LOT 2
PARCEL# — 7227800631
TOTAL AREA— 5,682 S.F. (0.130 AC)
DEDICATED ROW — 101 SE
TARGET LOT AREA — 5,581 S.F. (0.128 AC)
EXISTING DRIVE— 756 SF (0,017 AC)
PRO. ROOF —
PRO. DRIVE/WALK
CONIC, —
1, 591 SE (0.037 AC)
788 SE (0.018 AC)
TOTAL- TARGET NEW/REPLACED
IMPERVIOUS— 2,379 SE (0.055 AC)
42.6%
PRO. WALK WAY (CONC.) IN ROW
1,002 SE (0.023 AC)
CUT 270 CU YD
LAND DISTURBED 6500 SE
CONSTRUCTION SEQUENCE
1. SCHEDULE A PRE -CONSTRUCTION CONFERENCE.
2. INSTALL SILT FENCE AND CONSTRUCTION ENTRANCE ON SITE
3. FLAG CLEARING LIMITS.
4. CLEAR AND GRADE SITE WITHIN CLEARING LIMITS. INSTALL ROCKERIES PER PLAN AND
DETAIL.
5. INSTALL UTILITIES AND STORM DRAINAGE FACILITIES. PROVIDE CATCH BASIN INLET
PROTECTION.
6. BEGIN BUILDING CONSTRUCTION.
7. FINISH GRADE & PAVE PER PLANS.
8. STABILIZE ALL DISTURBED AREAS.
9. FLUSH & CLEAN STORM DRAINAGE FACILITIES.
10. INSTALL LANDSCAPING.
11. UPON FINAL SITE STABILIZATION, CLEAN SITE AND REMOVE REMAINING EROSION AND
SEDIMENTATION CONTROL MEASURES UPON SITE STABILIZATION.
R-424805
0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS 010
Z
DEVELOPMENT ENGINEERING Q
yqi 11 /27/2023 jai
W
U
Z
W
0
DATE:
DON_BORA_SFR_RESIDENCE 09-26-2022 0
EXISTING —CONDITIONS FIELDBOOK:- Lu
AND PAGE: - Ir
DRAWING NO:
TESC C 5 oC
LL
PLAN
SHEET: OF:
5 OR-7 (n