HomeMy WebLinkAboutPACCAR Kenworth - Permit Submittal_Approved 7.16.2024RENTON, WASHINGTON PACCAR KENWORTH R&D CIVIL SHEET LIST C-1.00 COVER SHEET & SHEET INDEX C-2.00 SITE PLAN C-3.00 TESC & DEMOLITION PLAN C-4.00 UTILITY PLAN C-4.10 UTILITY PROFILE C-4.20 DETAILS APPROX APPROXIMATELY EX EXISTING CIVIL ABBREVIATIONSEXISTING LEGEND (PER PROJECT SURVEY) WASHINGTON STATE PLANE COORDINATE SYSTEM, NAD 83/91, NORTH ZONE 4601, PER CITY OF RENTON CONTROL POINT NUMBERS 0452 (WSDOT IS17165) AND 1847. BASIS OF MERIDIAN NAVD 88 - CONSTRAINED TO CITY OF RENTON BENCHMARK 0452 AND 1847. NOTE: LOCAL CONTROL POINTS SHOWN HEREON WERE DERIVED FROM THE ABOVE MENTIONED CONTROL. CONTRACTOR TO VERIFY VERTICAL DATUM TO ON SITE TOPOGRAPHY AND CONTROL POINTS PROVIDED PRIOR TO CONSTRUCTION. VERTICAL DATUM UTILITIES SHOWN HEREON ARE PER KPFF AS-BUILT OF SITE SURFACE FEATURES IN CONJUNCTION WITH UNDERGROUND UTILITY LOCATES PERFORMED BY OTHERS, AND RECORD INFORMATION PROVIDED BY THE CITY OF RENTON, ALL UNDERGROUND UTILITIES SHOULD BE CONSIDERED APPROXIMATE ONLY AND VERIFIED PRIOR TO EXCAVATION. UTILITY NOTE R-428101 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428101 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DCOVER SHEET & SHEET INDEX R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42811601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 1.THIS IS A SUPERFUND SITE AND THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT MUST BE FOLLOWED. DURING ALL SUBSURFACE WORK, ENVIRONMENTAL CONSULTANTS MUST OBSERVE CONSTRUCTION. 2.ALL ON-SITE CONSTRUCTION PERSONNEL MUST BE 24 HOUR HAZWOPER TRAINED. 3.CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL WET AND DRY UTILITIES THAT ARE CAPPED. CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES TO ENSURE THIS OCCURS. 4.ALL UTILITY TRENCHES SHALL USE FILTER FABRIC ON THE BOTTOM AND SIDES OF TRENCH TO SEPARATE NATIVE SOILS AND FILL. 5.ALL TRENCHING AND EXCAVATION WORK IN AREAS BELOW THE CLEAN CAP (IE WITHIN CONTAMINATED SOILS) SHALL BE IN STRICT CONFORMANCE WITH THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT. 6.ALL BACKFILL WORK AND MATERIALS ASSOCIATED WITH ALL TRENCHING AND EXCAVATION WORK SHALL BE IN STRICT CONFORMANCE WITH THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT. ALL BACK FILLED TRENCHING AND LARGE EXCAVATION AREAS WILL BE LINED WITH A PERVIOUS GEOTEXTILE FABRIC (ORANGE) TO DELINEATE CLEAN BACK FILL MATERIAL FROM EXISTING CONTAMINATED SOILS. SPECIAL NOTES DEVELOPMENT ENGINEERING yqi 07/01/2024 REGIONAL FIRE AUTHORITY cthomas 07/01/2024 APPROVEDWATER UTILITY ABDOUL GAFOUR 07/16/2024 41SAWCUT (TYP)ASPHALT PAVEMENT PROPOSED STAIRS. REFER TO ARCHITECTURAL. EXISTING BUILDING TO REMAIN PROPOSED BUILDING OVERHANG MATCH EXISTING GRADES (TYP) 348 LF 10" DIP 21 LF 10" DIP 28 LF 10" DIP EXISTING 15.0' WATER EASEMENT EXISTING 15.0' WATER EASEMENT EXISTING TEE WITH GATE VALVE (TYP)5.00' (TYP)5.00' (TYP)5.00'15.00' WATER EASEMENT10.00'15.00'EXISTING GATE VALVE (TYP)5.00'IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428102 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DSITE PLAN DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42810 1 inch = 20 feet 10'20'40' PROPOSED BUILDING OVERHANG REFER TO ARCHITECTURAL. WATER MAIN SAWCUT PROPOSED 15FT WATER MAIN EASEMENT ASPHALT PAVEMENT LEGEND R-428102 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 DEVELOPMENT ENGINEERING yqi 07/01/2024 WATER UTILITY ABDOUL GAFOUR 07/16/2024 CUT AND CAP EXISTING 10" DIP WATER MAIN REMOVE EXISTING TEE AND VALVE REMOVE EXISTING CONCRETE BLOCKING ABANDON EXISTING 10" DIP WATER MAIN IN PLACE. FILL ABANDONED PIPE WITH CDF CUT AND CAP EXISTING 10" DIP WATER MAIN REMOVE EXISTING CONCRETE BLOCKING APPROX. LIMIT OF WORK CATCH BASIN PROTECTION (TYP) SAWCUT (TYP) CUT AND INSTALL TEMPORARY 10" CAP WITH CONCRETE BLOCKING SEE SHEET C-4.00 FOR CONNECTION CUT AND INSTALL TEMPORARY 10" CAP WITH CONCRETE BLOCKING SEE SHEET C-4.00 FOR CONNECTION DETAIL CUT AND INSTALL TEMPORARY 8" CAP WITH CONCRETE BLOCKING. SEE SHEET C-4.00 FOR CONNECTION SILT FENCE (TYP) SAWCUT (TYP) APPROX. LIMIT OF WORK CUT AND INSTALL TEMPORARY 10" CAP WITH CONCRETE BLOCKING SEE SHEET C-4.00 FOR CONNECTION DETAIL IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428103 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DDWG TITLE BOT TESC & DEMOLITION PLAN DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42810 1 inch = 20 feet 10'20'40' NOTES 1.PROTECT ALL EXISTING UTILITIES IN PLACE UNLESS OTHERWISE NOTED. 2.CONSTRUCTION SEQUENCING WILL BE DETERMINED BY THE CONTRACTOR. EXPECTED SEQUENCING WILL BE: - TESC INSTALLATION - SAWCUTTING PAVEMENT - CAPPING EXISTING WATER MAIN TO REMAIN - ABANDONING EXISTING WATER MAIN - CONTRUCT PROPOSED WATER MAIN - PAVEMENT REPAIR LEGEND DEMOLISH EXISTING UTILITY APPROXIMATE LIMIT OF WORK SAWCUT SILT FENCE PER COS STD PLAN 214.00 CAP UTILITY CATCH BASIN PROTECTION PER STD PLAN 216.30 DEMOLISH EXISTING ASPHALT PAVEMENT R-428103 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 DEVELOPMENT ENGINEERING yqi 07/01/2024 WATER UTILITY ABDOUL GAFOUR 07/16/2024 41WATER MAIN PROFILE 1 C-4.10 2 C-4.20 UTILITY TRENCH 7 C-4.21 6 C-4.21 EXISTING WATER MAIN TO BE ABANDONED 2 C-4.20 EXISTING 10" GATE VALVE EXISTING 1.5" IRRIGATION AND 2" DOMESTIC WATER SERVICE LINES 7.5'MIN10.0'MIN5.0'5.0'10" SLEEVES (MJ) N=182081.65 E=1303679.65 10" SLEEVES (MJ) N=182081.72 E=1303675.16 10"X10" SLEEVE (MJ) N=182084.27 E=1303521.94 1-10"X10"X10" TEE (MJXFL) 1-10" GATE VALVE (FLXMJ) CONCRETE BLOCKING 1-10"X8" REDUCER (MJXMJ) 1-8" SLEEVE (MJXMJ) N=182085.38 E=1303495.24 45° VERTICAL BEND (MJ) WITH CONCRETE BLOCKING N=182288.53 E=1303497.77 45° VERTICAL BEND (MJ) WITH CONCRETE BLOCKING N=182291.53 E=1303497.82 6 C-4.21 45° VERTICAL BEND (MJ) WITH CONCRETE BLOCKING N=182307.53 E=1303498.01 45° VERTICAL BEND (MJ) WITH CONCRETE BLOCKING N=182310.53 E=1303498.06 6 C-4.21 10"X10" SLEEVE (MJ) N=182433.10 E=1303519.51 1-10" X 45 DEGREE BEND (MJ) WITH CONCRETE BLOCKING N=182433.26 E=1303506.65 NEW 10" GATE VALVE (MJXMJ) N=182081.71 E=1303677.40 10" GATE VALVE (MJXMJ) N=182433.15 E=1303515.40 1-10" X 45 DEGREE BEND (MJ) WITH CONCRETE BLOCKING N=182426.29 E=1303499.50 6 C-4.21 4 C-4.21 4 LF 10" DIP 3 C-4.20 9 LF 10" DIP 10 LF 10" DIP 115 LF 10" DIP 2 LF 10" DIP 16 LF 10" DIP 2 LF 10" DIP 204 LF 10" DIP 27 LF 10" DIP 3 C-4.20 EX 8" DI WEX 10" DI WEX 10" DI W1.CONNECTION TO EXISTING WATER MAIN PER CITY OF RENTON STD DETAIL 300.4 2.ALL MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED WITH MEGALUG SERIES 1100 OR APPROVED EQUAL IN ADDITION TO CONCRETE BLOCKING. 3.ALL CONNECTION TO EXISTING WATER MAIN SHALL BE CONDUCTED BY CITY FORCES. 4.CITY STAFF SHALL OPERATE ALL WATER SYSTEM VALVES. CONTRACTOR NOT ALLOWED TO OPERATE VALVES. NOTES 3 C-4.20 APPROXIMATE LIMIT OF WORK WATER MAIN COUPLING. CONNECTION TO EXISTING WATER MAIN PER CITY OF RENTON STD DETAIL 300.4 TAPPING TEE. CONNECTION TO EXISTING WATER MAIN PER CITY OF RENTON STD DETAIL 300.5 LEGEND 4 C-4.20 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428104 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DDWG TITLE BOT UTILITY PLAN DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42810 1 inch = 20 feet 10'20'40' 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 R-428104 DEVELOPMENT ENGINEERING yqi 07/01/2024 WATER UTILITY ABDOUL GAFOUR 07/16/2024 20 25 30 35 40 45 50 55 60 20 25 30 35 40 45 50 55 60 1 C-4.00 WATER MAIN PROFILE SCALE: 1" = 20 H, 1" = 5' V EX 15" SD IE=33.13 EX POWER EX POWER 10"X10"X8" TEE 10"X10' SLEEVE 45° HORZ BEND EX 10" WATER EX 10" WATER SEE CONNECTION DETAILS PER COR STD PLAN 300.5 ON SHEETC-4.20 10"X10" SLEEVE EX 10" GV 10" GV 3.40'EX GRADE/ FINISH GRADE S N 45° VERT BENDS WITH CONCRETE THRUST BLOCK (TYP) 27 LF 10" DIP2.7'2.4'2.4'204 LF 10" DIP 10" GV 45° HORZ BEND 10 LF 10" DIP 9 LF 10" DIP 4 LF 10" DIP 115 LF 10" DIP 2.6'3.00'MIN 2 LF 10" DIP 16 LF 10" DIP 2 LF 10" DIP 2.5'EX 6" SD IE=36.50 ETHAFOAM PAD1.0'0 1 inch = 20 ft. HORZ 10'20'40' 0 1 inch = 5 ft. VERT 2.5'5'10' IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428105 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DDWG TITLE BOT UTILITY PROFILE DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42811601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 06/26/2024 R-428105 1.ALL MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED WITH MEGALUG SERIES 1100 OR APPROVED EQUAL IN ADDITION TO CONCRETE BLOCKING. NOTES DEVELOPMENT ENGINEERING yqi 07/01/2024 6" THICK (2'x2') WATER UTILITY ABDOUL GAFOUR 07/16/2024 1WATER PLAN GENERAL NOTES COR STD PLAN 300.0 3 C-4.00 CONNECTION TO WATER MAIN EXISTING TEE OR END LINE CAP COR STD PLAN 300.4 2 C-4.00 CONCRETE BLOCKING FOR HORIZONTAL FITTINGS COR STD PLAN 330.1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428106 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DDWG TITLE BOT DETAILS DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-4281R-428106 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 DEVELOPMENT ENGINEERING yqi 07/01/2024 WATER UTILITY ABDOUL GAFOUR 07/16/2024 FINISH GRADESAWCUT PAVEMENT 2' OUTSIDE OF TRENCH EDGES SAWCUT PAVEMENT 2' OUTSIDE OF TRENCH EDGES 2.0'2.0' 3.0'6"3.0' MIN COVEROVER PIPE6"10"TRENCH BACKFILL PER SECTION 9-03.19 OF WSDOT STD SPECS BACKFILL IN 8" LOOSE LIFTS (95% MAX DENSITY) PIPE BEDDING PER SECTION 9-03.12(3) OF WSDOT STD SPECS. COMPACT IN 4" LAYERS (95% MAX DENSITY) PATCH SURFACING TO MATCH EXISTING. MINIMUM 4" ASPHALT OVER 6" CRUSHED ROCK BASE ORANGE PERVIOUS GEOTEXTILE FABRIC ON SIDES AND BOTTOM. 2" MINIMUM LAP AT JOINTS 4 C-4.00 CONNECTION TO WATER MAIN TAPPING TEE AND VALVE COR STD PLAN 300.5 6 C-4.00 CONCRETE BLOCKING FOR VERTICAL FITTINGS WITH RESTRAINED JOINTS COR STD PLAN 330.1 5 C-4.00 CONCRETE BLOCKING FOR VERTICAL FITTINGS COR STD PLAN 330.1 IN COMPLIANCE WITH CITY OF RENTON STANDARDS Call 811 two business days before you dig R PRW-428107 PACCAR KENWORTH R&DC23005010LUA23-000230TED-40-4281PACCAR KENWORTH R&DDWG TITLE BOT DETAILS DRAWING CODE R&D BUILDING OFFICE REMODEL PACCAR-KENWORTH R&DWTR-27-42817 C-4.00 UTILITY TRENCH SCALE: 1" = 2' 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 05/24/2024 R-428107 1.EXCAVATED SOIL TO BE STOCKPILED AND TESTED FOR CONTAMINATION PER THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT. 2.ALL TRENCHING AND EXCAVATION WORK IN AREAS BELOW THE CLEAN CAP (IE WITHIN CONTAMINATED SOILS) SHALL BE IN STRICT CONFORMANCE WITH THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT. 3.ALL BACKFILL WORK AND MATERIALS ASSOCIATED WITH ALL TRENCHING AND EXCAVATION WORK SHALL BE IN STRICT CONFORMANCE WITH THE ENVIRONMENTAL REQUIREMENTS FOR THE RENTON SUPERFUND SITE PROVIDED BY THE PACCAR CORPORATE ENVIRONMENTAL DEPARTMENT. ALL BACK FILLED TRENCHING AND LARGE EXCAVATION AREAS WILL BE LINED WITH A PERVIOUS GEOTEXTILE FABRIC (ORANGE) TO DELINEATE CLEAN BACK FILL MATERIAL FROM EXISTING CONTAMINATED SOILS. NOTES DEVELOPMENT ENGINEERING yqi 07/01/2024 NOT APPLICABLE FOR THIS PROJECT WATER UTILITY ABDOUL GAFOUR 07/16/2024