HomeMy WebLinkAboutP_FairylandDrawings_v1RESPONSIBILITY OF THE GENERAL CONTRACTOR SHALL INCLUDE VERIFICATION EXISTING CONDITIONS IN THE FIELD, AND COORDINATION OF ALL DEFERRED SUBMITTALS. THIS INCLUDES COORDINATING THE WORK OF ALL SUBCONTRACTORS, PREPARATION OF SHOP DRAWINGS, VERIFYING CURRENT LICENSES, INSURANCES AND BONDS. THE SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PREPARING SOLUTIONS AND SHOP DRAWINGS, VERIFYING COMPLIANCE WITH LOCAL AUTHORITIES AND JURISDICTION, COMPLIANCE WITH CURRENT CODES, REGULATIONS AND REQUIREMENTS. ALL DEFERRED SUBMITTALS (MECHANICAL, ELECTRICAL AND PLUMBING, FIRE SPRINKLERS AND SUCH) SHALL BE INSTALLED AFTER ALL REQUIRED PERMITS HAVE BEEN APPROVED BY AUTHORITIES HAVING JURISDICTION. ELECTRICAL: 1.ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED COMMERCIAL ELECTRICIAN. THE WORK SHALL BE PERFORMED AS DESIGN-BUILD, WITH THE GC SUBMITTING THE BID AND OBTAINING ELECTRICAL DRAWINGS THAT COORDINATES WITH THE ARCHITECTURAL SET, AND COMPLIES WITH ALL CODES AND REGULATIONS. 2.THE GC'S ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING APPLICATION AND SECURING ALL REQUIRED ELECTRICAL PERMITS. MECHANICAL AND PLUMBING: 1. MECHANICAL AND PLUMBING WORK SHALL BE PERFORMED AS DESIGN-BUILD, WITH THE GC SUBMITTING THE BID AND DRAWINGS THAT COORDINATE WITH THE ARCHITECTURAL SET, AND COMPLIES WITH ALL CODES, REGULATIONS AND REQUIREMENTS. 2. THE GC'S MECHANICAL AND PLUMBING SUBCONTRACTORS SHALL BE RESPONSIBLE FOR SUBMITTING APPLICATION AND SECURING ALL REQUIRED MECHANICAL AND PLUMBING PERMITS. FIRE PROTECTION AND ALARM: 1. THE FIRE PROTECTION AND ALARM WORK SHALL BE PERFORMED BY A LICENSED SUBCONTRACTOR, AS A DESIGN-BUILD. DRAWINGS SHALL BE PREPARED BY THE SUBCONTRACTOR, COORDINATED WITH THE ARCHITECTURAL SET AND SUBMITTED WITH APPLICATIONS FOR FIRE PREVENTION/PROTECTION PERMITS DEFERRED SUBMITTALS COVER SHEET AND SITE PLAN A0.1 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A0.1 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: GENERAL NOTES REFERENCE SITE PLAN SHEET INDEX PROJECT TEAM SCOPE AND CODE A0.1 COVER SHEET, VICINITY MAP, AREAL VIEW SITE PLAN PROJECT DATA AND INFORMATION, PROJECT TEAM, CODES A0.2 GENERAL NOTES AND CODE INFORMATION, ADA REQUIREMENTS ACCESSIBILITY DIAGRAMS A0.3 OCCUPANCY PLAN, EGRESS PLAN, PLUMBING FIXTURES SUMMARY A1.0 SITE PLAN & EXISTING PARKING REQUIREMENTS COUNT A2.0 DEMOLITION PLAN, AND DEMOLITION NOTES A2.1 PROPOSED FLOOR PLAN AND NOTES A2.2 REFLECTED CEILING PLAN AND NOTES A2.3 BATHROOM ELEVATIONS, GENERAL MOUNTING SGHEME A2.4 LARGER KITCHEN PLAN, KITCHEN ELEVATIONS A3.1 DOORS AND WINDOWS SCHEDULE ARCHITECTURAL: 17630 108 AVE SE RENTON WA 98055 17630 108 AVE SE RENTON WA 98055 17630 108 AVE SE RENTON WA 98055 PROJECT LOCATION N PROJECT DATAVICINITY MAPSYMBOLS LEGENDARCHITECTURAL ABBREVIATIONS CLIENT:ARCHITECT: EXISTING BUILDING FAIRYLAND LEARNING CENTER TENANT IMPROVEMENT 17630 108TH AVE SE RENTON WA 98055 FAIRYLAND LEARNING CENTER HEGER ARCHITECTS, INC MARYNA MYSKO MILAN HEGER 17630 108TH AVE SE 11223 109TH AVE NE RENTON WA 98055 KIRKLAND WA 98033 (425)736-9526 (206) 898-6609 SCOPE OF WORK SUMMARY TENANT IMPROVEMENT WITHIN EXISTING SHELL, INTERIOR ONLY. 4,500 SQ.FT. REMODEL FOR A NEW DAYCARE FACILITY: BUILDING PERMIT AND CHANGE OF OCCUPANCY: LIMITED TO: SOME NEW WALLS, NEW RESTROOMS, FLOORS, INTERIOR DOORS, CABINETRY, THIS PROJECT REPRESENTS A CHANGE OF USE FROM “A-2” (RESTAURANT) TO OCCUPANCY GROUP “E” (CHILDREN OLDER THAN 2 1/2 YEARS) AND OCCUPANCY GROUP “I” (CHILDREN YOUNGER THAN 2 1/2 YEARS) APPLICABLE DESIGN CODES: 2018 INTERNATIONAL EXISTING BUILDING CODE 2018 INTERNATIONAL BUILDING CODE WITH WA STATE AMMENDMENTS 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 WASHINGTON STATE ENERGY CODE 2020 NATIONAL ELECTRICAL CODE 2018 UNIFORM PLUMBING CODE 2009 ANSI A117.1 - 2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES EGAL DESCROPTION: S 132 FT OF N 567.29 FT OF W 1/2 OF W 1/2 OF NW 1/4 OF NE 1/4 LESS 108TH AVE SE LESS C/M RGTS LESS POR PER DEED REC #20220426000979 PARCEL NUMBER:3223059119 JURISDICTION:CITY OF RENTON PROPERTY NAME:17630 108TH AVE SE ZONING:COMMERCIAL ARTERIAL (CA) IN URBAN DESIGN DISTRICT D OCCUPANCY:CURRENT - “A-2” PROPOSED CHANGE OF OCCUPANCY:FROM “A-2” TO “E” (CHILDREN OLDER THAN 2 1/2 Y) AND “I” (CHILDREN YOUNGER THAN 2 1/2 Y) CONSTRUCTION CLASS:WOOD FRAME EXISTING AREAS CALCULATION: LOT AREA: 36,554 SQ.FT. BUILDING NET AREA:7,475 SQ.FT. TENANT IMPROVEMENT AREA 4,500 SQ.FT. BUILDING CODE, TESTING & MANUFACTURE ABBREVIATIONS IRC INTERNATIONAL RESIDENTAL CODE IBC INTERNATIONAL BULDING CODE WSEC WACHINGTON STATE ENERGY CODE WSCA WASHINGTON STATE CODE AMENDMENTS-STATE AMENDMENTS TO A NATIONAL CODE NFPA NATIONAL FIRE PROTECTION ASSOСIATION - NATIONAL OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION - FEDERAL KCSWDM KING COUNTRY SURFACE WATER DESIGN MANUAL TESC TEMPORARY EROSION PROTECTION MEASURES ASTM AMERICAN SICIETY FOR TESTING & MATERIALS CERTIFIED UL UNDERWRITER'S LABORATORY TESTED AND CERTIFIED APA AMERICAN PLYWOOD ASSOCIATION TESTED AND CERTIFIED BMP BEST MANAGEMENT PRACTICES PER PLAN REFER TO MERRILL DESIGN PLAN VIEWS PER STRUCTURAL REFER TO STRUCTURAL ENGINEER OR ENGINEERING FOR SPECIFICATIONS AND INSTALLATION PER GEOTECH REFER TO GEOTECHNICAL ENGINEER OR GEOTECHNICAL REPORT AND RECOMMENDATIONS MANUF MANUFACTURERED PRODUCT WHICH HAS BEEN ENGINEERED, WARRANTEED, OR CERTIFIED SIMPSON STRUCTURAL HARDWARE & FASTENING MANUFACTURER REFER TO CURRENT SIMPSON CATALOG HARDIE JAMES HARDIE COMPANY - MANUFACTURER OF CEMENT BASED EXTERIOR SIDING &TRIM PRODUCTS TYVEK A DUPONT COMPANY HOUSE WRAP-MAY SUBSTITURE EQUIVALENT PRODUCT WHITE WOOD PRE-FINISHED TYPE OF EXTERIOR TRIM MATERIAL -DO NOT USE IN THIS PROJECT GENERAL ABBREVIATIONS OC ON CENTER CL CENTER LINE DIA DIAMETER HT HEIGHT W WIDTH L LENGTH D DEPTH HORIZ HORIZONTAL VERT VERTICAL MIN MINUMUM MAX MAXIMUM EQUIV EQUIVALENT EX EXISTING TO REMAIN EXT EXTERIOR INT INTERIOR GRADE GRADE IS THE FINISHED HEIGHT OF THE EARTH SURROUNDING THE BUILDUING EAVE THE FLAT EDGE OF A ROOF OVERHANG GABLE THE SLOPED EDGE OF A ROOF OVERHANG MATERIAL / FIXTURE ABBREVIATIONS HF HEM-FIR OSB ORIENTED STRAND BOARD SHEATING & SUB-FLOOR TJI ENGINEERED AND PRE-MANUFACTURED I-JOIST OR I-RAFTER TRUSS T ENGINEERED AND PRE-MANUFACTURED ROOF OR FLOOR TRUSS GL BM GLUE LAMINATED BEAM GLU-LAM GLUE LAMINATED BEAM PSL PARALAM BEAM -STRUCTURAL BEAM OF LAMINATED FIBERS LSL LAMINATED STRAND LUMBER - USED FOR STUDS, RIM JOISTS & BLOCKING LVL STRUCTURAL RIM JOIST USED IN CONJUNCTION WITH TJI'S STURDI-TREAD 1” X 11 ¼” BULLNOSED STRAND BOARD STAIR TREAD MATERIAL PT PRESSURE TREATED WOOD TK TIGHT KNOT T-1-11 EXTERIOR RATED PLYWOOD WITH ROUGH SAWN FACE -NO GROOVES VG VERTICAL GRAIN GWB GYPSUM WALL BOARD OF DRYWALL 16D LENGTH AND DIAMETER OF A NAIL GALV GALVANIZED STEEL WWM WELDED WIRE MESH REBAR STEEL REINFORCING ROD USED IN CONCRETE CONSTRUCTION #4 REBAR REFERS TO DIAMETER OF REBAR AB ANCHOR BOLT - BOLT EMBEDDED OR POURED INTO CONCRETE PVC PVC PLASTIC -TYPICAL IN WHITE DRAINAGE PIPE ABS ABS PLASTIC PIPE -BLACK WASTE PIPE USED IN PLUMBING PEX PEX PLASTIC FLEXIBLE PIPE -USED AS SUPPLY LINES FOR PLUMBING SCHED 40 THICKNESS AND PROPERTIES OF A PARTICULAR PLASTIC PIPE GAS APPLIANCE USES NATURAL GAS OR PROPANE FOR HEATING DW DISHWASHER DISP DISPOSER WITH DECK MOUNTED AIR SWITCH RANGE SINGLE APPLIANCE WITH STOVE TOP BURNERS AND OVEN BELOW MIRCO MICROWAVE OVEN HW HOT WATER HEATER FURN AIR HEATING AND MOVING FURNACE BBQ PROVIDE NATURAL GAS FOE AN OUTDOOR BARBEQUE BIBB FROST FREE HOSE BIBB LOCATION A.REFER TO BASIC BUILDING SPECIFICATIONS, REQUIREMENTS AND STANDARDS FOR REFER TO BASIC BUILDING SPECIFICATIONS, REQUIREMENTS AND STANDARDS FOR EXISTING SHELL AND CORE CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. B. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL GOVERNING ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL GOVERNING BUILDING CODES AND REGULATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK THAT HAS BEEN PERFORMED WHICH DOES NOT MEET THESE CODES AND REGULATIONS. C. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE TO THE ARCHITECT'S ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE TO THE ARCHITECT'S CONSTRUCTION DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR REPORTING IMMEDIATELY TO THE ARCHITECT ANY DISCREPANCIES OR DETAILS WHICH DO NOT MEET BUILDING D.THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS ON SITE PRIOR TO THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS ON SITE PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS, OR BETWEEN THE PLANS AND SPECIFICATIONS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. E. THE CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES AND PIPING BEFORE THE CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES AND PIPING BEFORE BEGINNING WORK. F. THE GC SHALL COORDINATE ALL OPERATIONS WITH THE OWNER, INCLUDING AREA FOR THE GC SHALL COORDINATE ALL OPERATIONS WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, AND ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, NOISY OR DISRUPTIVE WORK SHALL BE SCHEDULED AT LEAST ONE (1) WEEK IN ADVANCE OF THE TIME WORK IS TO COMMENCE. G.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. H. GC SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY GC SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGES AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. GC SHALL PROVIDE SHOP DWGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION (SHALL INCLUDE RATED FIRE DOORS AND HARDWARE). I.ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, SHAPE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. J. THE FLOORS MAY BE OCCUPIED DURING CONSTRUCTION. THE GC SHALL PROTECT ALL THE FLOORS MAY BE OCCUPIED DURING CONSTRUCTION. THE GC SHALL PROTECT ALL PERSONNEL, PASSERSBY OR VISITORS TO THE SITE FROM HARM AND INJURY. BARRIERS SHALL BE INSTALLED AS REQUIRED TO PROTECT EQUIPMENT INSTALLED DURING CONSTRUCTION, CAREFULLY MAINTAIN AND PROTECT MONUMENTS, BENCH MARKS AND THEIR REFERENCE POINT FROM BEING DESTROYED OR DISTURBED; REPLACE AS REQUIRED. K. EXISTING WORK DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL EXISTING WORK DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AND AT NO ADDITIONAL COST TO THE OWNER. ALL REPLACEMENT MATERIALS REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. L. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS, OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARDS OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT REQUIRED SUBMITTALS, PROVIDING COMPLETE BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. M. INSTALLATION OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE INSTALLATION OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS OR FLOOR CAVITIES. THE GC SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE, FILL ALL HOLES AND VOIDS IN FLOORS WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. N.OPENINGS REQUIRED FOR NEW WORK THAT PENETRATES EXISTING STRUCTURE SHALL BE OPENINGS REQUIRED FOR NEW WORK THAT PENETRATES EXISTING STRUCTURE SHALL BE COORDINATED WITH OWNER PRIOR TO COMMENCING THE WORK. ANY OPENING OVER 2" IN DIAMETER SHALL BE REVIEWED AND APPROVED BY OWNER. THROUGH CONCRETE SLABS OR WALLS, OR MASONRY WALLS, ALL ROUND HOLES SHALL BE CORE DRILLED WITH A DIAMOND DRILL AND ALL RECTANGULAR OPENINGS SHALL BE CUT WITH A DIAMOND SAW. IN NO CASE SHALL ANY STRUCTURAL MEMBER BE CUT. USE CARBIDE-TIPPED DRILLS FOR GYPSUM WALLBOARD PARTITIONS. KEEP OVER CUTTING TO A MIN.. MAINTAIN CONTINUITY AND INTEGRITY OF FIRE SEPARATION AT ALL TIMES. GROUT AROUND CONDUITS PASSING THROUGH CONCRETE WALLS AND FLOORS AND MASONRY WALLS. MAKE PATCHES WITH NEAT, TRIMMED EDGES: MATCH ADJACENT EXISTING WORK, AREA OF WORK N FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609 4'-0"2'-6"2'-6"4'-0"10" 3'-0" MIN 2'-8" MIN 2'-0" MAX.DEPH FOR MIN. CLEARANCE2'-6"10"4'-0"15" MIN.SIDE REACH RANGE60" MAX. A.F.F.B.O.HIGHEST TACTILE TEXT ADA COMPLIANT SIGN PER PLAN, SCHEDULE & DETAIL 1'-6" CLEAR WHEN SING ON PULL SIDE OF DOOR 9" TYP. 4" MAX 2'-3" OR GREATERLobby 6'-8" MIN.2'-3" OR BELOWANY DISTANCE CLR WIDTH PROTRUDING OBJECTS SCALE: 3/8'' = 1'-0"ICC/ANSI SEC. 304, 305 & 306 11 REACH RANGES SCALE: 3/8'' = 1'-0"ICC/ANSI SEC. 308 8 ACCESSIBLE SIGNALE LOCATION SCALE: 3/8'' = 1'-0"ICC/ANSI CHAP.7 4 COVER SHEET AND SITE PLAN A0.2 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A0.2 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609FLOOR OR GROUND SURFACES (ICC/ANSI SEC. 302 & 303): GENERAL: FLOOR OR GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. CHANGES IN LEVEL OF 1/4 INCH HIGH MAX. SHALL BE PERMITTED TO BE VERTICAL. CHANGES IN LEVEL BETWEEN 1/4 INCH HIGH MIN. AND 1-1/2 INCH HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE RAMPED AND SHALL COMPLY WITH ICC/ANSI SECTION 405 OR 406. WHEELCHAIR TURNING SPACE AND CLEAR SPACE (ICC/SEC.304 &305): CLEAR FLOOR OR GROUND SURFACE: FLOOR OR GROUND SURFACES OF A WHEELCHAIR TURNING SPACE SHALL HAVE A SLOPE NOT STEEPER THAN 1:48. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES MIN. BY 48 INCHES MIN. AND SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT. ONE FULL, UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOR OR GROUND SPACE. CIRCULAR SPACE: THE WHEELCHAIR TURNING SPACE SHALL BE NOT LESS THAN 60 INCHES DIAMETER MIN. WHEELCHAIR TURNING SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES. T-SHAPED SPACE: THE WHEELCHAIR TURNING SPACE MAY BE A T-SHAPED SPACE WITHIN A 60 INCH MIN. SQUARE WITH ARMS AND BASE 36 INCHES WIDE MIN. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MIN. IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MIN. T-SHAPED WHEELCHAIR TURNING SPACES SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES ONLY AT THE END OF EITHER THE BASE OR ONE ARM DOORS: UNLESS OTHERWISE SPECIFIED, DOORS SHALL BE PERMITTED TO SWING INTO WHEELCHAIR TURNING SPACE. ALCOVE CLEAR FLOOR SPACE: FORWARD APPROACH - THE WIDTH OF AN ALCOVE SHALL BE 36 INCHES MIN. WHERE THE DEPTH EXCEEDS 24 INCHES. PARALLEL APPROACH - THE WIDTH OF AN ALCOVE SHALL BE 60 INCHES MIN. WHERE THE DEPTH EXCEEDS 15 INCHES. KNEE AND TOE CLEARANCE (ICC/ANSI SEC.306): TOE CLEARANCE: SPACE UNDER AN ELEMENT BETWEEN THE FLOOR OR GROUND AND 9 INCHES ABOVE THE FLOOR OR GROUND SHALL BE TOE CLEARANCE. MAX. DEPTH IS PERMITTED TO EXTEND 25 INCHES MAX. UNDER AN ELEMENT AND 17 INCHES MIN. BENEATH THE ELEMENT. TOE CLEARANCE SHALL BE 30 INCHES WIDE MIN. KNEE CLEARANCE: SPACE UNDER AN ELEMENT BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FLOOR OR GROUND SHALL BE KNEE CLEARANCE. KNEE CLEARANCE SHALL BE PERMITTED TO EXTEND 25 INCHES MAX. UNDER AN ELEMENT AT 9 INCHES ABOVE THE FLOOR OR GROUND. WHERE KNEE CLEARANCE IS REQUIRED BENEATH AN ELEMENT AS PART OF A CLEAR FLOOR OR GROUND SPACE, THE KNEE CLEARANCE SHALL BE 11 INCHES DEEP MIN. AT 9 INCHES ABOVE THE FLOOR OR GROUND, AND 8 INCHES DEEP MIN. AT 27 INCHES ABOVE THE FLOOR OR GROUND. KNEE CLEARANCE SHALL BE 30 INCHES WIDE MIN. PROTRUDING OBJECTS (ICC/ANSI SEC. 307) PROTRUSION LIMITS: OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR OR GROUND SHALL PROTRUDE 4 INCHES MAX. HORIZONTALLY INTO THE CIRCULATION PATH. HANDRAILS SERVING STAIRS AND RAMPS SHALL BE PERMITTED TO PROTRUDE 4-1/2 INCHES MAX. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE 27 INCHES MAX. ABOVE THE FLOOR OR GROUND. PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. POST-MOUNTED OBJECTS: OBJECTS ON A SINGLE POST OR PYLON SHALL BE PERMITTED TO OVERHANG 12 INCHES MAX. WHERE MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR OR GROUND. REACH RANGES (ICC/ANSI SEC. 308) UNOBSTRUCTED REACH: WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. AND THE LOW SIDE REACH SHALL BE 15 INCHES MIN. ABOVE THE FLOOR OR GROUND. EXISTING PERMITTED AT 54 INCHES MAX. ABOVE THE FLOOR OR GROUND. OBSTRUCTED HIGH FORWARD REACH: WHERE A HIGH FORWARD REACH IS OVER AN OBSTRUCTION, THE CLEAR FLOOR OR GROUND SPACE SHALL EXTEND BENEATH THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH DEPTH OVER THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48 INCHES MAX. WHERE THE REACH DEPTH IS 20 INCHES MAX. WHERE THE REACH DEPTH EXCEEDS 20 INCHES, THE HIGH FORWARD REACH SHALL BE 44 INCHES MAX. AND THE REACH DEPTH SHALL BE 25 INCHES MAX. OBSTRUCTED HIGH SIDE REACH: WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN OBJECT AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES MAX., AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 INCHES MAX. THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. FOR A REACH DEPTH OF 10 INCHES MAX. WHERE THE REACH DEPTH EXCEEDS 10 INCHES, THE HIGH SIDE REACH SHALL BE 46 INCHES MAX. FOR A REACH DEPTH OF 24 INCHES MAX. OPERABLE PARTS (ICC/ANSI SEC. 309): HEIGHT: OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES. EXCEPT WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE, OR WHERE ELECTRICAL AND COMMUNICATIONS SYSTEMS RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. OPERATION: OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX. ACCESSIBLE ROUTES (ICC/ANSI SEC 402): ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A SLOPE NOT STEEPER THAN 1:20, DOORS AND DOORWAYS, RAMPS, CURB RAMPS, ELEVATORS, AND WHEELCHAIR (PLATFORM) LIFTS. ALL COMPONENTS OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE PORTIONS OF THIS STANDARD. WALKING SURFACES (ICC/ANSI SEC.403): SLOPE: THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE SURFACE SHALL NOT BE STEEPER THAN 1:48. CLEAR WIDTH: CLEAR WIDTH OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH ICC/ANSI 403.5 CLEAR WIDTH AT TURN: WHERE AN ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN OBJECT WHICH IS LESS THAN 48 INCHES WIDE, CLEAR WIDTHS SHALL BE 42 INCHES MIN. APPROACHING THE TURN, 48 INCHES MIN. DURING THE TURN, AND 42 INCHES MIN. LEAVING THE TURN. PASSING SPACE: AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200 FEET MAX. THESE PASSING SPACES SHALL BE EITHER A 60 INCH BY 60 INCH MIN. SPACE, OR AN INTERSECTION OF TWO WALKING SURFACES WHICH PROVIDE A T-SHAPED TURNING SPACE COMPLYING WITH ICC/ANSI SECTION 304. MANUAL DOORS AND DOORWAYS (ICC/ANSI SEC. 404): CLEAR WIDTH: DOORWAYS SHALL HAVE A CLEAR OPENING OF 32 INCHES MIN. CLEAR OPENING OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FLOOR OR GROUND. PROJECTIONS INTO THE MIN. CLEAR OPENING WIDTH MORE THAN 34 INCHES AND UP TO 80 INCHES ABOVE THE FLOOR OR GROUND ARE PERMITTED BUT SHALL NOT EXCEED 4 INCHES. MANEUVERING CLEARANCES: REQUIRED DOOR MANEUVERING CLEARANCES SHALL NOT INCLUDE KNEE AND TOE CLEARANCE. RECESSED DOORS: WHERE THE PLANE OF THE DOORWAY IS RECESSED MORE THAN 8 INCHES FROM THE PLANE OF THE WALL. CLEARANCES FOR FRONT APPROACH SHALL BE PROVIDED. TWO DOORS IN SERIES: DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES SHALL BE 48 INCHES MIN. PLUS THE WIDTH OF ANY DOOR SWINGING INTO THE SPACE. THE SPACE BETWEEN THE DOORS SHALL PROVIDE A TURNING SPACE COMPLYING WITH SECTION 304. DOOR HARDWARE: HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. SUCH HARDWARE SHALL BE 34 INCHES MIN. AND 48 INCHES MAX. ABOVE THE FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. DOOR CLOSERS: DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MIN. SPRING HINGES: DOOR SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MIN., DOOR-OPENING FORCE: FIRE DOORS SHALL HAVE THE MIN. OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAX. FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR: 5.0 POUNDS SLIDING OR FOLDING DOOR: 5.0 POUNDS THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. DOOR SURFACE: DOOR SURFACES WITHIN 10 INCHES OF THE FLOOR OR GROUND MEASURED VERTICALLY SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN SUCH SURFACE SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. EXCEPT FOR SLIDING DOORS, TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT NO LESS THAN 60 DEGREES FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH BOTTOM RAIL HEIGHT REQUIREMENT, AND DOORS WHICH DO NOT EXTEND TO WITHIN 10 INCHES OF THE FLOOR OR GROUND. VISION LITES: DOORS AND SIDELITES ADJACENT TO DOORS CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE PANEL 43 INCHES MAX. ABOVE THE FLOOR OR GROUND. RAMPS (ICC/ANSI SEC. 405): WALKING SURFACES ON ACCESSIBLE ROUTES WITH A RUNNING SLOPE STEEPER THAN 1:20 ARE RAMPS. SLOPE: RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. CLEAR WIDTH: THE CLEAR WIDTH OF A RAMP RUN SHALL BE 36 INCHES MIN.. HANDRAILS AND HANDRAIL SUPPORTS THAT ARE PROVIDED ON THE RAMP RUN SHALL NOT PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP RUN. THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAX. OUTDOOR RAMPS AND APPROACHES TO RAMPS SHALL BE DESIGNED SO THAT WATER WILL NOT ACCUMULATE ON WITHIN THE ROOM. WALKING SURFACES. LANDINGS: RAMPS SHALL HAVE LANDINGS AT BOTTOM AND TOP OF EACH RUN. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND THE CLEAR WIDTH OF LANDINGS SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. LANDING LENGTH SHALL BE 60 INCHES MIN. CLEAR. RAMPS THAT CHANGE DIRECTION AT LANDINGS SHALL HAVE A 60 INCH MIN. BY 60 INCH MIN. LANDING. DOORWAYS: WHERE DOORWAYS ARE ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY ICC/ANSI SECTIONS 404.2.3 AND 404.3.2 SHALL BE PERMITTED TO OVERLAP THE LANDING AREA. WHERE A DOOR THAT IS SUBJECT TO LOCKING IS LOCATED ADJACENT TO A RAMP LANDING, THE LANDING SHALL BE SIZED TO PROVIDE A TURNING SPACE COMPLYING WITH SECTION 304.3. HANDRAILS: RAMPS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE HANDRAILS COMPLYING WITH ICC/ANSI SECTION 505. HANDRAILS SHALL NOT REDUCE THE REQUIRED CLEARANCES OF A RAMP RUN OR LANDING. EDGE PROTECTION SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. THE FLOOR OR GROUND SURFACE OF THE RAMP RUN OR LANDING SHALL EXTEND 12 INCHES MIN. BEYOND THE INSIDE FACE OF A RAILING COMPLYING WITH ICC/ANSI SECTION 505. CURB OR BARRIER: A CURB OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4-INCH DIAMETER SPHERE BELOW A HEIGHT OF 4 INCHES. CURB RAMPS (ICC/ANSI SEC. 406): CURB RAMPS SHALL BE 36 INCHES WIDE MIN., EXCLUSIVE OF FLARED SIDES. CURB RAMPS AND THEIR SIDE FLARES SHALL NOT PROTRUDE INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR INTO PARKING SPACE ACCESS AISLES. THEY SHALL BE LOCATED OR PROTECTED TO PREVENT THEIR OBSTRUCTION BY PARKED VEHICLES. HANDRAILS ARE NOT REQUIRED. SIDES OF CURB RAMPS: WHERE PEDESTRIANS MUST WALK ACROSS A CURB RAMP, THE RAMP SHALL HAVE FLARED SIDES. SLOPE OF FLARES SHALL NOT BE STEEPER THAN 1:10. WHERE THE WIDTH OF THE WALKING SURFACE AT THE TOP OF THE RAMP AND PARALLEL TO THE RUN OF THE RAMP IS LESS THAN 48 INCHES WIDE, THE FLARED SIDES SHALL HAVE A SLOPE NOT STEEPER THAN 1:12. CURB RAMPS WITH RETURNED CURBS SHALL BE PERMITTED WHERE PEDESTRIANS WOULD NOT NORMALLY WALK ACROSS THE RAMP. COUNTER SLOPE: COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP OR ACCESSIBLE ROUTE SHALL NOT BE STEEPER THAN 1:20. TRANSITIONS FROM RAMPS TO WALKS, GUTTERS OR STREETS SHALL BE AT THE SAME LEVEL. LOCATION AT MARKED CROSSINGS: CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. LANDINGS: THE CLEAR LENGTH OF THE LANDING SHALL BE 36 INCHES MIN., WITH A CLEAR WIDTH AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES LEADING TO THE LANDING. DIAGONAL CURB RAMPS: DIAGONAL OR CORNER TYPE CURB RAMPS WITH RETURNED CURBS OR OTHER WELL-DEFINED EDGES SHALL HAVE THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. BOTTOMS OF DIAGONAL CURB RAMPS SHALL HAVE 48 INCHES MIN. CLEAR SPACE, MEASURED PARALLEL TO THE RUNNING SLOPE. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL PROVIDE THE 48 INCHES MIN. CLEAR SPACE WITHIN THE MARKINGS. DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A SEGMENT OF STRAIGHT CURB 24 INCHES LONG MIN. ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING. ISLANDS: RAISED ISLANDS IN CROSSINGS SHALL BE A CUT-THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH SIDES, AND A LEVEL AREA 48 INCHES LONG MIN. BY 36 INCHES WIDE MIN., IN THE PART OF THE ISLAND INTERSECTED BY THE CROSSING. PARKING SPASE (ICC/ANSI SEC. 502): VEHICLE SPACE SIZE: ACCESSIBLE CAR AND VAN PARKING SPACES SHALL HAVE AN ADJACENT ACCESS AISLE. CAR AND VAN PARKING SPACES SHALL BE 96 INCHES MIN. WIDTH. ACCESS AISLE: TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. PARKED VEHICLE OVERHANGS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE. ACCESS AISLES SERVING CAR PARKING SPACES SHALL BE 60 INCHES WIDE MIN. ACCESS AISLES SERVING VAN PARKING SPACES SHALL BE 96 INCHES WIDE MIN. ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE PARKING SPACES THEY SERVE AND THEY SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. FLOOR OR GROUND SURFACES: PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE SLOPES NOT STEEPER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE VERTICAL CLEARANCE: PARKING SPACES FOR VANS SHALL HAVE A VERTICAL CLEARANCE OF 98 INCHES MIN. AT THE SPACE AND ALONG THE VEHICULAR ROUTE THERETO. IDENTIFICATION: WHERE ACCESSIBLE PARKING SPACES ARE REQUIRED TO BE IDENTIFIED BY SIGNS, THE SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH ICC/ANSI SECTION 703.6. SUCH SIGNS SHALL BE 60 INCHES MIN. ABOVE THE FLOOR OR GROUND SURFACE OF THE PARKING SPACE, MEASURED TO THE BOTTOM OF THE SIGN. PASSENGER LOADING ZONES (ICC/ANSI SEC. 503): VEHICLE PULL-UP SPACE: PASSENGER LOADING ZONES SHALL PROVIDE AN ACCESS AISLE ADJACENT AND PARALLEL TO A VEHICLE PULL-UP SPACE 96 INCHES MIN. WIDTH AND 20 FEET MIN. LENGTH. ACCESS AISLES; ACCESS AISLES SHALL BE PART OF THE ACCESSIBLE ROUTE TO THE BUILDING OR FACILITY ENTRANCE. ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE 60 INCHES WIDE MIN. AND 20 FEET LONG MIN. ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE PARKING IN THEM. FLOOR OR GROUNG SURFACES: VEHICLE PULL-UP SPACES IN PASSENGER LOADING ZONES AND ACCESS AISLES SHALL HAVE SURFACE SLOPES NOT STEEPER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS VEHICLE PULL-UP SPACE THEY SERVE. VERTICAL CLEARANCE: VERTICAL CLEARANCE OF 114 INCHES MIN. SHALL BE PROVIDED AT PASSENGER LOADING ZONES AND ALONG VEHICLE ACCESS ROUTES TO SUCH AREAS FROM SITE ENTRANCES. STAIRWAYS (ICC/ANSI SEC. 504): TREADS AND RISERS: ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTH. RISERS SHALL BE 4 INCHES HIGH MIN. AND 7 INCHES MAX. TREADS SHALL BE 11 INCHES DEEP MIN., MEASURED FROM RISER TO OPEN RISERS SHALL NOT BE PERMITTED. STAIR TREAD SURFACE SHALL COMPLY WITH ICC/ANSI SECTION 302. NOSINGS: THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2 INCH MAX. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAX. FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL BE 1-1/2 INCHES MAX. BEYOND THE TREAD BELOW. OUTDOOR CONDITIONS: OUTDOOR STAIRS AND OUTDOOR APPROACHES 0 STAIRS SHALL BE DESIGNED SO THAT WATER WILL NOT ACCUMULATE ON WALKING SURFACES. HANDRAILS (ICC/ANSI SEC. 505): LOCATION: HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. IN ASSEMBLY SEATING AREAS, HANDRAILS SHALL NOT BE REQUIRED ON BOTH SIDES ALONG AISLE STAIRS, PROVIDED WITH A HANDRAIL EITHER AT THE SIDE OR WITHIN THE HANDRAILS SHALL NOT BE REQUIRED ON THE SIDES OF RAMPED AISLES SERVING SEATS, CONTINUITY: HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN, INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. HEIGHT: TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MIN. AND 38 INCHES MAX. VERTICALLY ABOVE STAIR NOSINGS, RAMP SURFACES, AND WALKING SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE STAIR NOSINGS AND RAMP SURFACES. CLEARANCE: CLEAR SPACE BETWEEN HANDRAIL AND WALL SHALL BE 1-1/2 INCHES MIN. GRIPPING SURFACE: GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL POSTS, OTHER CONSTRUCTION ELEMENTS, OR OBSTRUCTIONS. HANDRAIL BRACKETS OR BALUSTERS ATTACHED 10 THE BOTTOM SURFACE OF THE HANDRAIL ARE ALLOWED IF NOT MORE THAN 20 PERCENT OF THE HANDRAIL LENGTH IS OBSTRUCTED. SEE SECTION 505.6 FOR ADDITIONAL HORIZONTAL PROJECTION EXCEPTIONS. HANDRAILS, AND ANY WALL OR OTHER SURFACES ADJACENT TO THEM, SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS AND THEY SHALL HAVE A CIRCULAR CROSS SECTION WITH AN OUTSIDE DIAMETER OF 1-1/4 INCH MIN, AND 2 INCHES MAX. NON-CIRCULAR CROSS SECTIONS: HANDRAILS WITH OTHER SHAPES SHALL BE PERMITTED PROVIDED THEY HAVE A PERIMETER DIMENSION OF 4 INCHES MIN. AND 6-1/4 INCHES MAX. AND PROVIDED THEIR LARGEST CROSS-SECTION DIMENSION IS 2-1/4 INCHES MAX, TOP EXTENSION AT STAIRS: AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MIN. BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. SUCH EXTENSION SHALL RETURN 10 A WALL, GUARD, OR THE WALKING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. BOTTOM EXTENSION AT STAIRS: AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. IF PROVIDED AT THE BOTTOM OF A STAIR FLIGHT, A HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MIN. AND A HEIGHT EQUAL TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. SUCH EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. DRINKING FOUNTAINS (ICC/ANSI SEC. 602): CLEAR FLOOR OR GROUND SPACE: A 30° X 48° CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED. WHERE A FORWARD APPROACH IS PROVIDED, THE CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE UNIT AND SHALL INCLUDE KNEE AND TOE CLEARANCE. WHERE A PARALLEL APPROACH IS PROVIDED, THE CLEAR FLOOR OR GROUND SPACE SHALL BE CENTERED ON THE UNIT. SPOUT HEIGHT AND LOCATION: SPOUT QUTLETS FOR WHEELCHAIR ACCESSIBILITY SHALL BE 36 INCHES MAX. ABOVE THE FLOOR OR SPOUT OUTLETS FOR STANDING PERSONS SHALL BE 38 INCHES MIN. AND 43 INCHES MAX. ABOVE FLOOR OR GROUND. UNITS WITH A PARALLEL APPROACH SHALL HAVE THE SPOUT 3-1/2 INCHES MAX. FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. UNITS WITH A FORWARD APPROACH SHALL HAVE THE SPOUT 15 INCHES MIN. FROM THE VERTICAL SUPPORT AND 5 INCHES MAX. FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. OPERABLE PARTS SHALL COMPLY WITH ICC/ANSI SECTION 309 AND PROTRUDING UNITS SHALL COMPLY WITH ICC/ANSI SECTION 307. TOILET AND BATHING ROOMS (ICC/ANSI SEC. 603 AND 604): WHEELCHAIR TURNING SPACE: A CIRCULAR 60° DIAMETER WHEELCHAIR TURNING SPACE OR A "T’ SHAPED TURNING SPACE COMPLYING WITH ICC/ANSI SECTION 304 SHALL BE PROVIDED. DOORS:DOORS SHALL NOT SWING INTO THE CLEAR FLOOR OR GROUND SPACE OR CLEARANCE FOR ANY FIXTURE EXCEPT WHERE THE ROOM IS FOR INDIVIDUAL USE AND A 30” X 48” CLEAR FLOOR OR GROUND SPACE IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING. LOCATION: THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE, THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES MIN. TO 18 INCHES MAX. FROM THE SIDE WALL OR PARTITION. WATER CLOSET CLEAR SPACE: CLEARANCE AROUND THE WATER CLOSET SHALL BE 60 INCHES MIN. MEASURED PERPENDICULAR FROM THE SIDE WALL, AND 56 INCHES MIN. MEASURED PERPENDICULAR FROM THE REAR WALL. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE WITHIN THE WATER CLOSET CLEARANCE, OVERLAP: THE CLEARANCE AROUND THE WATER CLOSET SHALL BE PERMITTED 10 OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, TISSUE DISPENSERS, ACCESSIBLE ROUTES AND CLEAR FLOOR OR GROUND SPACE OR CLEARANCES AT OTHER FIXTURES AND THE WHEELCHAIR TURNING SPACE. WATER CLOSET HEIGHT AND CONTROLS: THE TOP OF WATER CLOSET SEATS SHALL BE 17 INCHES MIN. AND 19 INCHES MAX. ABOVE THE FLOOR OR GROUND. SEATS SHALL NOT RETURN AUTOMATICALLY 70 A LIFTED POSITION. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC, HAND—OPERATED FLUSH CONTROLS SHALL COMPLY WITH ICC/ANSI SECTION 309. GRAB BARS: GRAB BARS SHALL BE PROVIDED ON THE REAR WALL AND ON THE SIDE WALL CLOSEST TO THE WATER CLOSET. SIDE WALL GRAB BAR SHALL BE 42 INCHES LONG MIN., 12 INCHES MAX. FROM THE REAR WALL AND EXTENDING 54 INCHES MIN. FROM THE REAR WALL. IN ADDITION, A VERTICAL GRAB BAR 18 INCHES MIN. IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES ABOVE THE FLOOR WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39 INCHES AND 41 INCHES FROM THE REAR WALL. THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MIN. AND EXTEND FROM THE CENTER LINE OF THE WATER CLOSET A MIN. OF 12 INCHES ON THE SIDE CLOSEST TO THE WALL AND 24 INCHES MIN. ON THE TRANSFER SIDE. DISPENSERS: DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND 609.3. WHERE THE DISPENSER IS LOCATED ABOVE THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES MIN. AND 36 INCHES MAX. FROM THE REAR WALL WHERE A DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET OF A DISPENSER SHALL BE LOCATED WITHIN AN AREA 24 INCHES MIN. AND 42 INCHES MAX. FROM THE REAR WALL. THE OUTLET OF THE DISPENSER SHALL BE LOCATED 18 INCHES MIN. AND 48 INCHES WAX. AB0VE THE FLOOR. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR THAT 00 NOT ALLOW CONTINUOUS PAPER FLOM, MIRRORS: VIRRORS SHALL BE MOUNTED WTH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAX. ABOVE THE FLOOR OR GROUND. COAT HOOKS AND SHELVES: COAT HOOKS PROVIDED WITHIN TOILET ROOMS SHALL ACCOMMODATE A FORWARD REACH OR SIDE REACH COMPLYING WITH ICC/ANSI SECON 308 WHERE PROVIDED, A FOLD-DOWN SHELF SHALL BE 40 INCHES MIN. AND 48 INCHES WAX ABOVE THE FLOOR OR GROUND. URINALS (ICC/ANSI SEC. 605) HEIGHT AND CONTROLS: URINALS SHELL BE OF THE STALL TYPE OF SHALL SE OF THE WALL-HUNG TYPE WITH THE RW AT 17 INCHES MAX. ABOVE THE FLOOR OR GROUND. WALL HUNG URINALS SHALL BE 13-1/2 INCHES MIN. IN DEPTH MEASURED FROM THE OUTER FACE OF THE URINAL RM TO THE WALL FLUSH CONTRCLS SHALL GE HAND OPERATED OR AUTOMATIC CLEAR FLOOR 0R GROUND SPACE: A 30" X 48" CLEAR FLOOR OR GROUND SPACE POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. TOILET COMPARTMENTS FOR MULTI-TOILET ROOMS (ICC/ANSI SEC. 604): WHEELCHAIR ACCESSIBLE COMPARTMENTS: WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES WIDE MIN. MEASURED PERPENDICULAR TO THE SIDE WALL, AND 56 INCHES DEEP MIN. FOR WALL HUNG WATER CLOSETS AND 59 INCHES DEEP MIN. FOR FLOOR MOUNTED WATER CLOSETS, MEASURED PERPENDICULAR 70 THE REAR WALL, AMBULATORY ACCESSIBLE COMPARTMENTS: AMBULATORY ACCESSIBLE COMPARTMENTS SHALL BE 60 INCHES DEEP MIN. AND 36 INCHES WIDE. WATER CLOSETS LOCATED IN AMBULATORY ACCESSIBLE COMPARTMENTS SHALL HAVE THE CENTERLINE OF THE WATER CLOSET 17 INCHES MIN. AND 19 INCHES MAX. FROM THE SIDE WALL OR PARTITION. THE WATER CLOSET SHALL BE CENTERED IN THE COMPARTMENT. COMPARTMENT DOORS SHALL NOT SWING INTO THE MIN. REQUIRED COMPARTMENT AREA. GRAB BARS FOR AMBULATORY ACCESSIBLE COMPARTMENTS: A 42" SIDE WALL GRAB BAR SHALL BE PROVIDED ON BOTH SIDES OF THE COMPARTMENT. DOORS:COMPARTMENT DOORS SHALL NOT SWING INTO THE MIN. REQUIRED COMPARTMENT AREA. TOILET COMPARTMENT DOORS: SHALL COMPLY WITH ICC/ANSI SECTION 404, EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, THE CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 INCHES MIN. THE DOOR SHALL BE HINGED 4 INCHES MAX. FROM THE ADJACENT WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. COMPARTMENT ARRANGEMENTS SHALL BE PERMITTED FOR LEFT-HAND OR RIGHT—HAND APPROACH TO THE WATER CLOSET. TOE CLEARANCE: IN WHEELCHAIR ACCESSIBLE COMPARTMENTS, THE FRONT PARTITION AND AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9 INCHES MIN. ABOVE THE FLOOR AND EXTENDING 6 INCHES DEEP BEYOND THE COMPARTMENT-SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. TOE CLEARANCE AT THE FRONT OF THE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 62 INCHES DEEP WITH A WALL—HUNG WATER CLOSET OR 65 INCHES DEEP WITH A FLOOR-MOUNTED WATER CLOSET. TOE CLEARANCE AT THE SIDE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66 INCHES WIDE. LAVATORIES AND SINKS (ICC/ANSI SEC. 606): CLEAR FLOOR OR GROUND SPACE: A 30” X 48” CLEAR FLOOR OR GROUND SPACE POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE SHALL BE PROVIDED. HEIGHT AND CLEARANCES: THE FRONT OF LAVATORIES AND SINKS SHALL BE 34 INCHES MAX. ABOVE THE FLOOR OR GROUND, MEASURED TO THE HIGHER OF THE FIXTURE RIM OR COUNTER SURFACE. FAUCETS SHALL COMPLY WITH ICC/ANSI SECTION 309. HAND-OPERATED, SELF-CLOSING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MIN EXPOSED PIPES AND SURFACES: WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. GRAB BARS (ICC/ANSI SEC. 609): SIZE.GRAB BARS SHALL HAVE A CIRCULAR CROSS SECTION WITH A DIAMETER OF 1-1/4 INCH MIN. AND 2 INCHES MAX. NON-CIRCULAR CROSS-SECTIONS: GRAB BARS WITH OTHER SHAPES SHALL BE PERMITTED PROVIDED THEY HAVE A CROSS SECTION DIMENSION OF 2 INCHES MAX., AND A PERIMETER DIMENSION OF 4 INCHES MIN. AND 4.8 INCHES MAX. AND WITH EDGES HAVING 1/8 INCH MIN. RADIUS. SPACING: THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1-1/2 INCHES. THE SPACE BETWEEN THE GRAB BAR AND OBJECTS BELOW AND AT THE ENDS SHALL BE 1-1/2 INCHES MIN. THE SPACE BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES MIN. POSITION OF GRAB BARS: GRAB BARS SHALL BE MOUNTED IN A HORIZONTAL POSITION, 33 INCHES MIN, AND 36 INCHES MAX. ABOVE THE FLOOR, SURFACE HAZARDS: GRAB BARS AND ANY WALL OR OTHER SURFACES ADJACENT TO GRAB BARS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A RADIUS OF 1/8 INCH MIN. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS, INSTALLATION: GRAB BARS SHALL BE INSTALLED IN ANY MANNER THAT PROVIDES A GRIPPING SURFACE AT THE LOCATIONS SPECIFIED IN THIS STANDARD AND THAT DOES NOT OBSTRUCT THE CLEAR FLOOR SPACE. STRUCTURAL STRENGTH: ALLOWABLE STRESSES IN BENDING, SHEAR, AND TENSION SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE OR SUPPORTING STRUCTURE. SIGNAGE (ALL SIGNAGE TO COMPLY WITH ICC/ANSI CHAP. 7): ACCESSIBLE ENTRANCES: ACCESSIBLE BUILDING ENTRANCES SHALL BE IDENTIFIED WITH STANDARD SIGNS AND DIRECTIONAL SIGNS THAT COMPLY WITH ICC/ANSI SECTION 703 AND ARE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS REQUIRED TO IDENTIFY FACILITIES THAT ARE ACCESSIBLE. THE SYMBOL IS TO BE A WHITE FIGURE ON BLUE BACKGROUND (COLOR NO. 15090) IN FEDERAL STANDARD 595A. EXCEPTION: A SPECIAL SIGN OR IDENTIFICATION WHICH COMPLEMENTS DECOR OR A UNIQUE DESIGN MAY BE APPROVED WHEN IT IS DETERMINED BY AN ENFORCING AGENCY THAT SUCH SIGNS AND IDENTIFICATION PROVIDE ADEQUATE DIRECTION. CHARACTERS: LETTERS AND NUMBERS ON SIGNS ARE TO HAVE A WIDTH TO HEIGHT RATIO OF BETWEEN 3:5 AND 1:1, AND A STROKE WIDTH TO HEIGHT RATIO BETWEEN 1:5 AND 1:10. WHEN RAISED OR RECESSED CHARACTERS OR SYMBOLS ARE USED, THEY ARE TO BE RAISED OR RECESSED A MIN. 1/32 INCH AND ARE TO BE SANS SERIF TYPE FONT. RAISED CHARACTERS ARE TO BE AT LEAST 5/8 INCH HIGH AND RECESSED CHARACTERS AND SYMBOLS ARE TO HAVE A 1/4 INCH MIN. STROKE WIDTH, BRAILLE: CONTRACTED GRADE 2 BRAILLE SHALL COMPLY WITH SECTION 703.4, AND IS T0 BE USED WHEREVER BRAILLE IS REQUIRED. WHEELCHAIR ACCESSIBLE PUBLIC TELEPHONES (ICC/ANSI SEC. 704): CLEAR FLOOR OR GROUND SPACE: A 30” X 48” CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED. THE CLEAR FLOOR OR GROUND SPACE SHALL NOT BE RESTRICTED BY BASES, ENCLOSURES, OR FIXED SEATS. WHERE A PARALLEL APPROACH IS PROVIDED, THE DISTANCE FROM THE EDGE OF THE TELEPHONE ENCLOSURE 70 THE FACE OF THE TELEPHONE UNIT SHALL BE 10 INCHES MAX. WHERE A FORWARD APPROACH IS PROVIDED, THE DISTANCE FROM THE FRONT EDGE OF A COUNTER WITHIN THE ENCLOSURE TO THE FACE OF THE TELEPHONE UNIT SHALL BE 20 INCHES MAX. OPERABLE PARTS: THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE WITHIN THE REACH RANGES SPECIFIED IN SECTION 309. TELEPHONES SHALL HAVE PUSH BUTTON CONTROLS WHERE SERVICE FOR SUCH EQUIPMENT IS AVAILABLE. TELEPHONE DIRECTORIES: WHERE PROVIDED, TELEPHONE DIRECTORIES SHALL COMPLY WITH ICC/ANSI SECTION 309. CORD LENGTH: WHEELCHAIR ACCESSIBLE TELEPHONES SHALL BE EQUIPPED WITH A HANDSET CORD LENGTH OF 29 INCHES MIN. VOLUME-CONTROL TELEPHONES: TELEPHONES WITH VOLUME CONTROL SHALL BE EQUIPPED WITH A RECEIVER VOLUME CONTROL WITH A RANGE THAT PROVIDES 12 DB OF GAIN MIN. AND 20 DB OF GAIN MAX. AN AUTOMATIC RESET SHALL BE PROVIDED. TELEPHONES SHALL BE HEARING AID COMPATIBLE. TTY:WHERE USED WITH A PAY TELEPHONE, TEXT TELEPHONES SHALL BE PERMANENTLY AFFIXED WITHIN, OR ADJACENT 10, THE TELEPHONE ENCLOSURE. IF AN ACOUSTIC COUPLER IS USED, THE TELEPHONE CORD SHALL BE SUFFICIENTLY LONG TO ALLOW CONNECTION OF THE TTY AND THE TELEPHONE RECEIVER. WHERE PAY TELEPHONES DESIGNED TO ACCOMMODATE A PORTABLE TTY ARE PROVIDED, THEY SHALL BE EQUIPPED WITH A SHELF AND AN ELECTRICAL OUTLET WITHIN OR ADJACENT TO THE TELEPHONE ENCLOSURE. THE TELEPHONE HANDSET SHALL BE CAPABLE OF BEING PLACED FLUSH ON THE SURFACE OF THE SHELF. THE SHELF SHALL BE CAPABLE OF ACCOMMODATING A TTY AND SHALL HAVE A 6 INCHES HIGH MIN. VERTICAL CLEARANCE ABOVE THE AREA WHERE THE TTY IS PLACED.4'-0"15" MIN.FORWARD REACH RANG OCCUPANCY PLAN Scale: 1/8" = 1'-0" N EGRESS PLAN Scale: 1/8" = 1'-0" N COVER SHEET AND SITE PLAN A0.3 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A0.3 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609IEBC NOTE BUILDING CODE SUMMARY PLUMBING FIXTURE CALCS CHANGE OF USE NOTES FIRE PROTECTION NOTES PARKING CALCULATIONS EGRESS DATA & OCC LOAD EGRESS NOTES EGRESS LEGEND хх' THE COMPLIANCE PATH IS IEBC, CHANGE OF OCCUPANCY, CHAPT. 1012 CHANGE OF USE CLASSIFICATION. SECTION 1011 - CHANGE OF OCCUPANCY GROUPS 1011.1.1 - COMPLIANCE WITH CHAPTER 9 1 HOUR SEPARATION REQUIRED BETWEEN OCCUPANCY E AND I, FROM THE NEIGHBORING TENANT, BECAUSE THE BUILDING HAS FIRE SUPPRESSION SPRINKLERS. 1011.2 - FIRE PROTECTION SYSTEMS SPRINKLERS ARE PROVIDED IN THIS BUILDING 1011.3 - INTERIOR FINISHES - ALL NEW FINISHES ARE TO COMPLY WITH IBC 2018 CODE 1011.4 - MEANS OF EGRESS ALL NEW OCCUPANCY GROUPS (E and I) ARE SAME HAZARD LEVEL. ALL OTHER SPACES ARE INCIDENTAL USE. ALL MEANS OF EGRESS SIGNS AND LIGHTING ARE TO COMPLY WITH 2018 IBC CODE 1011.5 - THE ENTIRE NEW OCCUPANCY IS ON GROUND FLOOR. BUILDING IS EQUIPPED WITH FIRE SPRINKLERS. THEREFORE, 4,500 SQ.FT. IS IN COMPLIANCE 1011.6 - THERE IS NO WORK PROPOSED TO THE EXTERIOR OF THIS BUILDING. THE BUILDING EXITS COMPLY WITH THE CODES. THE PROPOSED USE - OCCUPANCY E AND I - AS A TENANT SPACE OF 4,500 SQ.FT. REQUIRES AN APPROVED FIRE SPRINKLER SYSTEM AND AN APPROVED AUTOMATIC FIRE ALARM SYSTEM. THE BUILDING IS CURRENTLY EQUIPPED WITH FIRE SPRINKLERS, THEREFORE AN UPDATED FIRE PREVENTION PLAN SHALL BE REQUIRED. THESE PLANS SHALL BE SUBMITTED TO THE FIRE DEPARTMENT. NEW FULL HEIGHT WALLS WILL REQUIRE ADJUSTMENT IN SPRINKLER LOCATIONS AND THE NUMBER OF SPRINKLERS TO COMPLY WITH THE FIRE CODE. THE EXISTING OCCUPANCY GROUP WAS “A” AND IT IS PROPOSED TO CHANGE TO “E” AND “I” BOTH E AND I ARE PERMITTED USES IN THIS ZONING COMMERCIAL ARTERIAL, URBAN DESIGN DISTRICT D. 1.SEE PARKING CALCULATIONS FOR COMPLIANCE 2.NO STRUCTURAL UPGRADES ARE REQUIRED FOR THIS BUILDING 3.BUILDING IS V-B TYPE OF CONSTRUCTION, AND OCCUPANCY E AND I ARE ALLOWED. 4.THE TENANT SPACE IS SPRINKLERED AND HVAC IS PROVIDED BY THE LANDLORD, ALREADY EXISTING HVAC SYSTEM. OCCUPANCY GROUP:“E” AND “I” BUILDING CONSTRUCTION TYPE V - B SPRINKLERED:YES FIRE ALARM SYSTEM:REQUIRED OCCUPANCY SEPARATION:1 HOUR BETWEEN THIS TENANT AND NEIGHBOR PLUMBING FIXTURES COUNT: PER IBC, CHAPTER 29, WA STATE AMENDMENTS, TABLE 2902.1 REQUIRES: OCCUPANCY “E” GROUP TOILETS LAVS 1/35 BOYS 1/85 BOYS 1.25 GIRLS 1/50 GIRLS OCCUPANCY “I” GROUP 1/15 CHILDREN 1/15 CHILDREN STAFF RESTROOM 1 1 ------------------------------------------------------------------------------- TOTAL TOILETS REQUIRED PROVIDED OCCUPANCY “E” 50 CHILDREN TOILETS 2 4 TOTAL LAVATORIES 1 4 OCCUPANCY “I” 5 CHILDREN TOILETS 0 0 TOTAL LAVATORIES 1 2 STAFF TOILETS 1 1 STAFF LAVATORIES 1 1 JANITOR MOP SINK 1 1 -------------------------------------------------------------------------- TOTAL OVERALL: TOILETS:3 5 LAVATORIES:3 7 MOP SINK:1 1 EGRESS TRAVEL DISTANCE = < 250' PER IBC TABLE 1017.2 COMMON PATH OF TRAVEL = < 75' PER IBC 1006.2.1 MINIMUM DISTANCE BETWEEN EXITS ARE GREATER THAN 1/2 DIAGONAL DISTANCE OF AREA SERVED TOTAL OCCUPANT LOAD SUMMARY: NUMBER OF EXITS REQUIRED:3 NUMBER OF EXITS PROVIDED:6 1/ PROVIDE EGRESS LIGHTS (ELECTRIC LED LIGHTING) PER IBC 1008. ELECTRICAL CONTRACTOR RESPONSIBLE FOR THIS SYSTEM AS A DEFERRED PERMIT, SHALL PROVIDE FULL COMPLIANCE TO THE TENANT SPACE. 2/ THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 11 LUX (1 FOOT CANDLE) AT THE WALKING SURFACE. DCYF LICENSING OCCUPANT LOAD NUMBER OF CHILDREN AGE > 2 1/2 53 NUMBER OF CHILDREN AGE < 2 1/2 5 STAFF 7 ---------------------------------------------------------- TOTAL OCCUPANT LOAD 65 DAYCARE AREA (SQ. FT.):4,500 SQ.FT. ENTIRE BUILDING TOTAL: 7,475 SQ.FT. TOTAL PARKING STALLS ON LOT: 38 PARKING DESIGNATION NUMBER OF PARKING CHILDREN TOTAL 58 6 STAFF 7 7 REQUIRED PARKING 13 REQUIRED DISABLED PARKING 1 TOTAL PROVIDED: 15 DISABLED PROVIDED SHARED 2 VETERINARIAN ANIMAL CARE 1/200 S.F.15 TOTAL PROVIDED 15 PARKING REQUIRED TOTAL 30 DISABLED PARKING TOTAL 2 EXISTING PARKING ON LOT 38 PLUMBING CODE EXCERPT WAC 170-295-5100 ONE (1) FLUSH-TYPE TOILET AND ONE (1) ADJACENT SINK FOR HAND WASHING WITHIN HEARING RANGE OF THE CLASSROOM PER /15 CHILDREN ONE (1) TOILET AND SINK FOR STAFF CHILDREN YOUNGER THAN 18 MONTHS ARE NOT INCLUDED IN THIS CALCULATION. THESE CHILDREN REQUIRE A (1) SINK AS WELL AS ONE (1) TABLE AND SINK. LICENSING CRITERIA FROM DCYF CONDITIONS: 1/ ALL CHILDREN RESTROOMS DO NOT REQUIRE SEPARATION BY SEX DESIGNATIONS PER DEPARTMENT OF EARLY LEARNING. THESE AGE GROUPS REQUIRE ASSISTANCE WHEN USING THE RESTROOMS, UP TO THE AGE OF 5. 2/ CHILDREN YOUNGER THAN 18 MONTHS DO NOT REQUIR RESTROOMS. INSTEAD, DIAPER CHANGE TABLE WITH SINK SHALL BE PROVIDED. 3/ SEPARATE RESTROOM IS PROVIDED FOR THE STAFF. THIS RESTROOM SHALL BE ADA COMPLIANT. OCCUPANCY NOTES ALL CHILDREN OVER 2 1/2 YEARS OLD SHALL BE CLASSIFIED AS OCCUPANCY “E” ALL CHILDREN UNDER 2 1/2 YEARS OLD SHALL BE CLASSIFIED AS OCCUPANCY “I” 39 sq ft 85 sq ft 350 sq ft 446 sq ft classroom 5 244 sq ft classroom 4 560 sq ft classroom 3 677 sq ft classroom 2 294 sq ft reception 7A6A5A4A3A3214'-9"20'-0"D C B A 23'-0"101 EXIT 67 sq ft office 102 338 sq ft classroom 1 103 104 105 106 43 sq ft43 sq ft 5'6'-5"5' 5'5'18'-9" 6'-4" 11'-6"12'-4"8'-10"18'-6"6'5'-8" 515 sq ft 8'-5"8'10'-8" 7'-6" 5"3'-0"5"6'-4"10"3'-0" 5"5" 1'-6" 5" 3'26'-5"20"20"2'1'5"20"20"2'1'2'-10"5"12'-9"10"11'-2"7'-1"6'-6"20'-4"6'-6"7'-1"5"5" 5" 12'-5"5'7"3'-3" 5"5"11'-8"5"9'-4"7'-6" 20"20"2'1'5"5"3'-0"7'-1"9'-4"5'-10"7"10"5"3'6'3'9'15'-5"15'-5"15'-5"3'-1"3'-1"3"6"9'-7"8'-0"7"107 108 5'5' 5' 5'9'-10"12'-0"27'-9" 221 sq ft staff room 74 sq ft 5" 7"6'7"20"20"2'7'-3"5"6'10"22'-4"5' 2'-6"7"13'-6"12'-9"6'-5"4'-6"20'-4"6'-7"5"3'5'-0"5" 3'-6"20'-10" 5" 5'7"109 110 5" 43 sq ft 111 112 5'10'-10"1'-5"7'-10" 5"2'3'2'5"4'-5" washing machine and dryer 113 EXIT EXIT EXIT 114 5" 115 116 81 126'-3" 3 4 5 6 7 5"1'-5"4'-0"5"5" 1'-3"5'-0"1'-3"5'-0"1'-3"5'-0" 1'-3"5'-0"1'-0"3'-0"5'-0"2'-0"5'-0"8'-0" 3'-0"3'-5"2'-10"3'-5"2'-10"3'-5"3'-0"3'-0"3'-0" 3'-0"2'-10"2'-9"2'-10" W1 D3 D1 D2 D4 D5 5'-8" D6 D7 D8 D9 D10 D11 D12 D13 2'-3"5'-8"2'-2''D14 3'-0" D15D16 4'-0"6'-0"D17 3'-0" D18 D19 D20 D21 W2 W3 W4 W5 W6 W7 W8 W9 W10 OCCUPANCY E OCCUPANCY E OCCUPANCY E OCCUPANCY E OCCUPANCY I 1 HOUR RATED SEPARATION (FROM ANIMAL HOSPITAL) 39 sq ft 85 sq ft 350 sq ft 446 sq ft classroom 5 244 sq ft classroom 4 560 sq ft classroom 3 677 sq ft classroom 2 294 sq ft reception 7A6A5A4A3A3214'-9"20'-0"D C B A 23'-0"101 EXIT 67 sq ft office 102 338 sq ft classroom 1 103 104 105 106 43 sq ft43 sq ft 5'6'-5"5' 6'-4" 11'-6"12'-4"8'-10"18'-6"515 sq ft 8'-5"8'10'-8" 5"3'-0"10"3'-0"3'26'-5"5"20'-4"3'-0"3'6'3'9'15'-5"15'-5"15'-5"3'-1"3'-1"3"6"9'-7"8'-0"107 108 5'5' 5' 5'9'-10"12'-0"27'-9" 74 sq ft 7"6'7"7'-3"5"6'22'-4"5' 4'-6"20'-4"6'-7"5"5'-0"5" 3'-6"20'-10"7"109 110 43 sq ft 111 112 5'10'-10"1'-5"7'-10" 5"2'3'2'5"4'-5" washing machine and dryer 113 EXIT EXIT EXIT 114 5" 115 116 81 126'-3" 3 4 5 6 7 5"1'-0"3'-0"5'-0"5'-0"3'-0"3'-0" 3'-0" 3'-0"2'-10"W1 D3 D1 D2 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 5'-8"D14 3'-0" D15D16 4'-0"6'-0"D17 3'-0" D18 D19 D20 D21 W2 W3 W4 W5 W6 W7 W8 W9 W10 1 HOUR RATED SEPARATION (FROM ANIMAL HOSPITAL) 37' 75' EXIST. EXIT 35'45' 33' 29' 53' 33' 74' 221 sq ft staff room 9'-0 18'-0"2'-0"24'-0"5'-0"24'-0"9'-0"23'-0"21'-0"9'-018'-0"24'-0"5'-0"5'-0"8'-0"20'-0"8'-0"9'-0"8'-0"9'-0"8'-6"c c c c 16'-0"24'-0"15'-0"276.8' 276.8' DRIVEWAY127.7'108th Ave. SE9'5'5' 5' c c 127.7'SITE PLAN Scale: 1" = 10'-0" N WALK SIDEWALK FAIRYLAND PROPOSED T.I. 4,500 SQ.FT 17630 108 th Ave SE RENTON WA 98055 1 2 3 4 5 6 7 8 9 10 11 PICK-UP & DROP-OFF PARKING 12 13 14 15 PARKING CALCULATIONS DAYCARE AREA (SQ.FT.): 4.500 SQ.FT. ENTIRE BUILDING TOTAL: 7.475 SQ.FT. TOTAL PARKING STALLS ON LOT: 38 PARKING DESIGNATION NUMBER OF PARKING CHILDREN TOTAL 58 6 STAFF 7 7 REQUIRED PARKING 13 REQUIRED DISABLED PARKING 1 TOTAL PROVIDED: 15 DISABLED PROVIDED SHARED 2 VETERINARIAN ANIMAL CARE 1 /200 S.F. 15 TOTAL PROVIDED 15 PARKING REQUIRED TOTAL 30 DISABLED PARKING TOTAL 2 EXISTING PARKING ON LOT 38 NUMBER PARKING FOR DAYCARE 9' x18' TYP. BICYCLE PARKING 0'10'20'30'40'50' COVER SHEET AND SITE PLAN A1.0 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A0.1 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609 87A6A5A4A3A3214'-9"20'-0"D C B A 23'-0"12'-4"10"3'-6"9'15'-5"15'-5"15'-5"3'-1"3'-1"3"6"9'-7"8'-0"22'-8"27'-9" 7'-10" 3'-6" 117'-9" 81 126'-3" 3 4 5 6 7 EXIST. EXIT EXIST. EXIT EXIST. EXIT EXIST. EXIT EXIST. EXIT 5'-0"2'-0"5'-0"3'-3"5'-0"7'-7"15'-0"16'-3"5" DEMOLITION PLAN Scale: 3/16" = 1'-0" N DEMOLITION NOTES A.OBTAIN DEMOLITION PERMITS AND COSSTS OF SAME IN CONTRACT PRICE. B.FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ITEMS AS IDICATED. C.GC SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. D.IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. E.AT COMPLETIONS OF DEMOLITION WORK, THE CONSTRUCTION AREAS SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE RRMOVED. F.ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. G.AS DIRECTED BY BUILDING MANAGEMENT, ALL DOORES, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWNSPOUTS AND FLUORESCENTS), AND SPECIAL EQUIPMENT SHOWN TO BE REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND REUSED AS DIRECTED HEREIN, OR RETURNED TO BUILDING STOCK. H.IN PARTITIONS TO BE REMOVED, REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THESMOSTATS, ECT., TO THEIR SOURCE. I.GC SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE CAUSED BY HIM OR HIS SUBGCS TO EXISTING CONSTRUCTION PUBLIC CORRIDORS, RESTROOMS OR TENANT SPACES. REFINISH TO MARCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. J.NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS, NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN ITS INTENDED PURPOSE. K.REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES AND TANANT. L.REMOVE ALL EXISTING MATERIALS, WICH WOULD CAUSE RISES OR DEPRESSIONS IN NEW FLOORING SURFASE, SUCH AS FASTENERS, OUTLET CORES. COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. M.DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DWGC. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DWGC. N.RATED WALLS SHALL NOT BE PENETRATED UNLESS THE RATING IS MAINTAINED. O.ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1 /4" IN 10'-0". THE GC SHALL NOTIFY ARCHITECT OF ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 7'-4"7'-4"7'-4"7'-4" COVER SHEET AND SITE PLAN A2.0 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A2.0 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609 39 sq ft 85 sq ft 350 sq ft 221 sq ft kitchen 446 sq ft classroom 5 244 sq ft classroom 4 560 sq ft classroom 3 677 sq ft classroom 2 294 sq ft reception W1 W1 W2 W3 W3 W3W4 W5 W4 W6 87A6A5A4A3A32 W5 W6 14'-9"20'-0"17'-2"5'-0"F E D C B A 23'-0"101B 101 EXIT 101C 101A 67 sq ft office 102 102 338 sq ft classroom 1 103 104 103 104 105101D 105A 106 43 sq ft43 sq ft 5'6'-5"5' 5'5'18'-9" 6'-4" 11'-6"12'-4"8'-10"18'-6"6'6' 515 sq ft 8'-5"8'10'-8" 2'-9" 5' 7'-6" 5"3'-6"5"5'-10"10"3'-6" 5" 3'-6" 5" 1' 5" 3'26'-5"2' 20"20"2'1'3'-6"5"20"20"2'1'3'-6"5"12'-9"10"2'-9"11'-2"7'-1"6'-6"20'-4"6'-6"7'-1"5"5" 5" 3'-6" 12'-5"5'7"3'-3" 5"5"11'-8"5"9'-4"7'-6" 20"20"2'1'3'-6"5"5"3'-6"7'-1"9'-4"5'-10"7"10"3'-6"5"3'6'3'9'15'-5"15'-5"15'-5"3'-1"3'-1"3"6"9'-7"8'-0"7"106 107 108 108 107A 5'5'5'5' 5'9'-8"12'-2"27'-9" 221 sq ft kitchen 74 sq ft 5" 7" 3'-6"6'7"20"20"2'7'-3"5"6'10"2'-4"22'-4"5' 2'7"13'-6"12'-9"6'-5"4'-6"20'-4"6'-7"5"3'5'-2"5" 3'-6"20'-10" 5" 3'-6"5'7"107B 109 109 110 110A 110B 5" 3'-6" 43 sq ft 111 3'-6"111 112 5'10'-10"1'-5"7'-10" 1'-0"2'-9"2'3'2'5"4'-1" washing machine and dryer 113 113A 113B EXIT EXIT EXIT 114 114 112 3'-6" 5" 115 116 115 117'-9" 81 126'-3" 3 4 5 6 7 1 MAIN FLOOR PLAN Scale: 3/16" = 1'-0" N 5"1'-2"4'-3"5"5" W7 W8 W9 W8 W10 80'-2"1'-3"5'-0" W11 1'-3"5'-0"1'-3"5'-0" W11W11 1'-3"5'-0" W11 1'-0"105B3'-6"5'-0"2'-0"5'-0"W10 7'-0" COVER SHEET AND SITE PLAN A2.1 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A0.1 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609 39 sq ft 85 sq ft 350 sq ft 446 sq ft classroom 5 244 sq ft classroom 4 560 sq ft classroom 3 677 sq ft classroom 2 294 sq ft reception 7A6A5A4A3A32 D C B A 101 EXIT 67 sq ft office 102 338 sq ft classroom 1 103 104 105 106 43 sq ft43 sq ft 515 sq ft 15'-5"15'-5"15'-5"3'-1"3'-1"3"6" 107 108 27'-9" 74 sq ft 109 110 43 sq ft 111 112 113 EXIT EXIT EXIT 114 115 116 81 126'-3" 3 4 5 6 7 1 Scale: 3/16" = 1'-0" NLIGHTING & SWITCHING 4'-0"3'-7"TEMPERTURE DETECTOR SMOKE DETECTOR FIRE SPRINKLERS SWITCH 3 -WAY SWITCH EL. OUTLET EXHAUST FAN∞CEILING LIGHT WALL LIGHT-VANITY CEILING LIGHT 2' X 2' LINEAR LIGHT T SD S3S33'-7"3'-7"T SD S3SS 221 sq ft staff room3'-4"3'-2"3'-4"3'-2"3'-6"5'-11"9'-4"5'-11"4'-6"5'-8"S33'-10"3'-10"6'-8"6'-8" S3 3'-6"3'-0"3'-7" S3 T SD GFC 8'-0"8'-0"3'-6"3'-7"3'-7"9'-6" S3 6'-0"6'-0" S3 2'-5"2'-5"6'-2"SD TSS 5'-4"4'-2"8'-2"5'-8"3'-6"7'-8"7'-8"GFC GFC SSSSS3'-2"3'-2"6'-6"S3S3 TSD S3 2'-6"3'-4"∞200 CFM Greenheck SP-A200 EXHAUST FAN S SD GFC 6807 3'-0"6'-6" S3 S3 SD 6'-6"5-0"5'-6"5'-6" S3S3 SD CEILING NOTES A.COORONATE TH WORK OF ALL TRADES INVOLED IN THE CELING WORK TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PPNG, CELING SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTS DWG. B.PERIMETER CELING ANGEL, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITES AND PAINED TO MATCH CELING FINISH. C.FURNISH AND INSTALL ALL ASSOCIATED TRM AND SEISMIC BRACING AS REQUIRED. D.LIGHT FIXTURES, NEW SPRINKLERS AND OTHER CEILING ELEMANTS SHALL BE CENTERED IN THE 2'X2' SECTION OF INDIVIDUAL CELING TILES U.O.N. (EXIST.SPRINKLERS TO REMAIN UNLESS CONFLICT WITH NEW ELEMENTS). E.PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.O.N. F.ALL SWITCHES AND DIMMERS SHALL BE LOCATED 46" ABOVE FINISHED FLOOR TO CENTER OF SWITCH U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANCED TOGETHER AND FINISHED WITH ONE COVER PLATE U.O.N. G.ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. H.THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING HEIGHTS, LIGHT TYPES, LIGHT FIXTURES, AND ASSOCIATED ITEMS. I.IN THE EVENT OF DISCREPANCIES BETWEEN THE ARCHITECTS REFLECTED CEILING PLAN AND LIGHTING PLAN, IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING BEFORE ORDERING MATERIALS OF PROCEEDING WITH WORK. J.ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS ABOVE-CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION BY OTHERS (PERMITTED SEPARATELY). K.NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR (E) CONDUIT, PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEN ARCHITECTS CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. L.SUBMIT GRILLE, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO INSTALLATION. M.VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ALL OTHER RELATED ITEMS. INSTALL NEW PLUMBING, MECHANICAL. FANS, DUCTS, CONDITIONS INCLUDING LUMNARES. N.INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SMILAR COVER OVER LOUVER, LENS BAFFLE, ETC. TO AVOID FIXTURE SOLING OF DAMACE, FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW, ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION - RELAMP EXISTING FIXTURES. O.GC TO VERIFY CODE COMPLIANCE OF EXISTING ACOUSTICAL CEILING GRID SYSTEM AND ASSOCIATED SEISMIC BRACNG RESTRAINTS. SYSTEMS FOUND NOT IN COMPLIANCE SHALL BE MODIFIED AND/OR NEW PROVIDED AS REQUIRED BY CURRENT BUILDING CODES (INCLUDING, BUT NOT UMIRED TO; CURRENT IBC WALL MOLDING (2" ANGLE) AND SEISMIC SEPARATION JOINTS). P.GC TO VERIFY CODE COMPLIANCE OF ALL EXISTING LIGHTING FIXTURES AND ASSOCIATED SEISMIC BRACING RESTRAINTS. FIXTURES FOUND NOT IN COMPLIANCE SHALL BE MODIFIED AND/OR NEW PROVIDED AS REQUIRED BY CURRENT BUILDING AND/OR ENERGY COMPLIANCE CODE. Q.ALL EXITING LIGHTS AND EGRESS LIGHTING LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. R.ALL SMOKE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH IMC/IBC OR SUPERSEDING CODE. ALL FIRE DAMPERS SHALL BE INSTALLED IN ACCORDANCE WITH INE/IBC OR SUPERSEDING CODE. S.PROVIDE EGRESS ILLUMINATION FOR IBC 1006, CONTRACTOR IS RESPONSIBLE FOR DESIGNE OF THIS SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE. T.THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE (11 LUX) AT THE WALKING SURFACE. U.PROVIDE PLAN NOTES TO ADDRESS COMPLIANCE WITH WSEC SECTION C503.6 AND C405.2 V.WSEC SECTION C504.6 REQUIRES LIGHTING CONTROLS FOR ALTERNATIONS TO COMPLY WITH C405.2 OCCUPANCY SENSOR CONTROLS SHALL BE INSTALLED AS REQUIRED PER C405.2.1. W.DAYLIGHT ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE DAY LIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF GENERAL LIGHTING IN ACCORDANCE WITH WSEC SECTION 405.2.4.1 REFERENCE WSEC SECTION C103.2 X.COMPLIANCE WITH THE 2015 WSEC FOR LIGHTING REQUIREMENTS WILL BE REVIEWED UNDER THE ELECTRICAL PERMIT (AREA >2,500 SF) COVER SHEET AND SITE PLAN A2.2 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A2.2 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609decor light 2'-0"A ADULT RESTROOM # 115 SCALE: 1/2" = 1'-0"3'-0"3'-5"18"MIN36" MIN 2'-0" 12" MIN 4'-6" WET WALL3'-6"2'-10"4'-0"3'-8"10'-10"27"3'-0" 34" folding changing table 3'-0"1'-6"24" MIN1'-0"2'-3"4'-5"3'-0"5" 36" MIN B 5"4'-5"3'-0" C2'-10"27"2'-8"3'-4"A CHILDREN'S RESTROOM # 104 SCALE: 1/2" = 1'-0"3'-0"1'-6"24" MIN 6'-8"2'-0"3'-0"3'-5"1'-8"4'-6" WET WALL2'-6"3'-4"4"18"MIN5"1'-10"6'-4" 2'-0" 2'-0"2'-3"B C 6'-8" 5" 1'-2" 4'-2"2'-6"2'-0" 6'-8" 5"3'-0"3'-3"1'-10"A CHILDREN'S RESTROOM # 108 #106 SCALE: 1/2" = 1'-0" B 1'-4"1'-8"1'-10"6'-4" 2'-0"2'-3"1'-2" 1'-20"27"36" MIN 3"2'-6"2'-0" 6'-8" 5"3'-0"3'-3"1'-10"1'-4"1'-8"1'-10"6'-4" 2'-0"2'-3"1'-2" 1'-20"27"36" MIN C 7'-3" 1'-5"5'-0"3'-0"3'-0"1'-6"24" MIN4'-6" WET WALL3'-4"4"5"4'-2" A CHILDREN'S RESTROOM # 111 SCALE: 1/2" = 1'-0"2'-0"3'-0"3'-5"1'-8"18"MIN1'-10"6'-0" 1'-8"2'-3"B 1'-0"2'-6"2'-10" 7'-3"1'-10"C TAG QTY RESTROOM EQUIPMENT SCHEDULE DESCRIPTION MFR, STYLE, PRODUCT NO NOTES AC-1 AC-2 AMERICAN STANDARD, BABY DEVORO FLOWISE 10" HIGH ROUND FRONT TOILET TOILET SEAT: AMERICAN STANDARD, COMMERCIAL TOILET SEAT FOR BABY DEVORO BOWL TOILET - CHILD CADET RIGHT HEIGHT ELONGATED PRESSURE-ASSISTED TOILET 1.6 GPF/6.0 LPF TOILET TOILET SEAT: COMMERCIAL HEAVY DUTY PLASTIC TOILET SEAT, 19555CT/1955SSCT TOILET -ADULT AC-3 WALL-MOUNTED SINK AC-4 FAUCET AC-5 FEMININE NAPKIN WASTE RECEPTABLE AC-6 WALL-MOUNTED WATER FOUNTAIN AC-7 TOILET SEAT COVER DISPENSER AC-8 COUNTER MOUNTED SOAP DISPENSER AC-9 MOTORIZED PAPER TOWEL DISPENSER AC-10 RECESSED PAPER TOWEL WASTE RECEPTACLE AC-11 MIRROR AC-12 ADA GRAB BARS W/VERTICAL BAR-ADULT AC-13 TOILET PAPER DISPENSER AC-14 HAND -WASHING TROUGH SINK-CHILD KOHLER, K-3202-0 BROCKWAY 48"X17.5" WALL MOUNTED SERVICE SINK BOBRICK, #B-2840 BOBRICK, 1 1/4" S.STL.VERTICAL GRAB BAR B-5806 SERIES BOBRICK, #B-3644 TBD 24" X 36" GEORGIA PACIFIC, #59466 CHROME GOJO CXI, #8520-01 BOBRICK, #B-301 ELKAY VERSATILE COOLER WALL MOUNT BI-LEVEL ADA NON- FILETERED 8GPH LIGHT GRAY GRANITE, MODEL: EZSTL8LC BOBRICK, #B-254 DELTA, LAVATORY FAUCET 520-MPU-DST, CHROME AMERICAN STANDARD, LUCERNE WALL-HUNG LAVATORY4'-6" WET WALL4'-6" WET WALLCOVER SHEET AND SITE PLAN A2.3 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A2.3 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609AC-12 AC-12 AC-12 AC-12 AC-12 AC-2 AC-1 AC-1 AC-1 AC-1 AC-11 AC-13 AC-13 AC-3 AC-3 AC-3 AC-3 AC-3 AC-9 3'-0"3'-9" AC-9 AC-9 AC-9 AC-9 AC-10 AC-13 AC-4 AC-4 AC-4 AC-4 RESTROOMS NOTES: GENERAL ADA PLUMBING NOTES: A.WATER CLOSET CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. B. CONTROLS FOR FLUSHING WATER CLOSETS AND URINALS SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS, NO MORE THAN 43 -1/2” A.F.F. C.THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS FORCE. D. IF SELF-CLOSING VALVES ARE USED, THEY SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS E. FAUCETS CONTROLS AND OPERATING MECHANISM SHALL NOT BE OF THE TYPE REQUIRING TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST (OPERABLE WITH ONE HAND SUCH AS LEVER-OPERATED) AND AN OPERATING FORCE NOT EXCEEDING 5 POUNDS. F. LAV. - INSULATE ALL EXPOSED PLUMBING LINES AND DRAINS. STAFF WORK AREA 1 SCALE: 1/2" = 1'-0"2'-6"2'-0"2'-10"1'-6"1'-6" 2'-8" HAND SINK CHANGE OF WALL PLANE CLOSED PLASTIC LAMINATE LOWER CABINET WITH DRAWER AND ONE ADJUSTABLE SHELF 2'-10"1'-6"3'-0" HAND SINK CLOSED PLASTIC LAMINATE LOWER CABINET WITH DRAWER AND ONE ADJUSTABLE SHELF CHANGE OF WALL PLANE 4'-6" WET WALL # 103 #105 #109 #110 SCALE: 1/2" = 1'-0"2'-10"1'-6"3'-0" HAND SINK CLOSED PLASTIC LAMINATE LOWER CABINET WITH DRAWER AND ONE ADJUSTABLE SHELF CHANGE OF WALL PLANE 4'-6" WET WALL # 107 MINI CITCHEN IN THE CLASS ROOM MINI CITCHEN IN THE CLASS ROOM SCALE: 1/2" = 1'-0" COVER SHEET AND SITE PLAN A2.4 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A2.4 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-66092'-8" 3/4" STAFF WORK AREA 2 SCALE: 1/2" = 1'-0"27"CLOSED PLASTIC LAMINATE UPPER CABINETS WITH ONE ADJUSTABLE SHELF DISHWASHER 1'-6"1'-6"2'-10"2'-0" 10" 6'-0" 11'-0" 2'-2" ADA COMPLIANT FAUCET ADA COMPLIANT FAUCET ADA COMPLIANT PLASTIC LAMINATE LOWER CABINET WITH INTEGRAL TOEKICK 2'-5"2'-11"2'-2"8'-0"1'-10"4'-10" REFRIGERATOR 2'-11"2'-6"2'-0"2'-10"2'-8"1'-0"1'-0" 3" CLOSED PLASTIC LAMINATE UPPER CABINETS WITH ONE ADJUSTABLE SHELF 3/4" 4'-10" 1'-6"1'-6"1'-6" RESTROOM / KITCHEN NOTES: A.GRAB BAR: BOBRICK 250 LB. MINIMUM. 33” MIN. 36” MAX. HEIGHT TO THE TOP OF THE GRIPPING SURFACE. PROVIDE THE REQUIRED QUANTITY AND LENGTH AS INDICATED ON THE DRAWINGS OR AS REQUIRED BY THE CODE. THE GRAB BAR SHALL BE 1-1/2” IN DIAMETER AND MOUNTED WITH 1-1/2” CLEARANCE FROM THE WALL. B.WALL MOUNTED SOAP DISPENSER AND HAND SANITIZER DISPENSER (36” MAX. HT.) SUPPLIED BY “ECOLAB” AND INSTALLED BY THE G.C. NOTE:SOAP AND HAND SANITIZER DISPENSERS TO BE PROVIDED AT EACH KITCHEN HAND SINK. C.MIRROR: (BOTTOM OF REFLECTED SURFACE AT 40” MAXIMUM HT.) MODEL B-165-1836 (18” X 36”) STAINLESS STEEL CHANNEL FRAME MIRROR OR SIMILAR D.TOILET PAPER HOLDERS: MANUFACTURED BY AMERICAN STANDARD OR SIMMILAR E.PAPER WASTE RECEPTACLE: (REQUIRED) MODEL B-3644 AS MANUFACTURED BY BOBRICK OR EQUIVALENT. F.PAPER TOWEL DISPENSER: “SAN JAMAR” OR SIMILAR G.TOILET SEAT COVER DISPENSER BY ROCHESTER MIDLAND CORP. PRODUCT CODE 25132000 (STAINLESS STEEL) H.UNISEX IDENTIFICATION SIGNAGE: PER ADA DETAILS J.COAT HOOK: BOBRICK, MOUNTED ON INSIDE OF EACH RESTROOM DOOR. MOUNT AT 38” - 40” A.F.F. FOR ADA ACCESSIBLE LOCATIONS, AND AT 48” A.F.F. MAXIMUM FOR NON-ADA ACCESSIBLE LOCATIONS. GENERAL NOTES: 1. PROVIDE 6” TILE BASE WHERE FLOOR TILE IS INSTALLED, OR 6” VINYL BASE 2.PROVIDE WASHABLE FLOOR SURFACE IN KITCHEN AND RESTROOMS: EITHER TILE OR VINYL. PROVIDE VINYL BASE AROUND WASHABLE FLOOR SURFACES 3.PROVIDE WASHABLE BACKSPLASH 18” ABOVE COUNTERTOP IN KITCHEN 4.PROVIDE 3” WOOD BASE AROUND CARPETED AREAS 5.EPOXY GROUT TO BE USED AT ALL TILE FLOORS. 6.CABINETS INSTALLED IN KITCHEN TO BE FABRICATED FROM WASHABLE LAMINATE. 7.COUNTERTOPS TO BE LAMINATE OR QUARTZ. WINDOW SCHEDULE WIN NO. WIDTH HEIGHT DESCRIPTION TEMPERED FRAME W1 4'-0" 3'-0" W2 5'-0" 3'-0" W3 3'-0" W4 5'-0" W5 W6 DOOR SCHEDULE DR NO. WIDTH HEIGHT. TEMPERED D 1 HARDWARE DISCRIPTION 3'-0" 3'-0" 6'-8" 5'-8" 6'-8" 6'-0" 6'-8" 3'-0"VERIFY 3'-0" 6'-8" W7 W8 W9 W10 W1 3'-6"3'-0"3'-0"5'-0"3'-0"5'-0" YES PICTURE VINYL 3'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" W 6W 5W 4 W10W 9W 8W 7W 3W 23'-6"3'-0"5'-0"3'-6"3'-0"4'-0" YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL YES PICTURE VINYL NOTE TYPE SLAB GLAZED D 2 D 3 D 4 D 5 D 6 D 7 D 8 D 9 D 10 D 11 D 12 D 13 D 14 D 15 D 16 D 17 D 18 D 19 D 20 3'-0" 6'-8" GLAZED GLAZED SWING SWING YES YES MATERIAL WOOD FRAME LEVER WOOD FRAME LEVER 3'-0" 6'-8" 4'-0" 6'-8" 6'-8" 2'-10" 6'-8" 3'-0" 6'-8" 3'-0" 6'-8" 2'-10" 6'-8" 2'-10" 6'-8" 3'-0" 6'-8" 2'-10" 6'-8" 3'-0" 6'-8" 3'-0" 6'-8" 5'-8" 6'-8" 2'-10" 6'-8" GLAZED GLAZED SLAB SLAB SLAB SLAB SLAB SLAB SLAB SLAB SLAB GLAZED GLAZED GLAZED GLAZED GLAZED SWING DOUBLE SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING SWING DOUBLE SWING SWING SWING DOUBLE SWING DOUBLE SWING YES - - - YES - - - YES YES YES - - - YES YES YES - WOOD FRAME WOOD FRAME WOOD FRAME WOOD FRAME WOOD WOOD WOOD WOOD WOOD WOOD WOOD WOOD FRAME WOOD FRAME WOOD FRAME WOOD WOOD WOOD ALUM.PANIC HARDWARE (EXIT DOOR) LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER LEVER GLAZED D 21 5'-8" 6'-8"DOUBLE SWING YES WOOD FRAME LEVER 6'-8"2'-10"6'-8"5'-8" D 1 D 2 6'-8"3'-0" D 3 D 4D 5 D 7 D 8 D 11 D 6 D 9 D 10 D 12 VERIFY3'-0" D 18D 13 D 15D 14 D 21 D 19 6'-8"D 16 4'-0"6'-8"D 17 6'-0" D 20 1 Scale: NTS DOOR & WINDOW SCHEDULE COVER SHEET AND SITE PLAN A3.1 24" X 36" SCALE AS NOTED PLOT DATE:2024 - CAD FILE:_A3.1 JOB NUNBER: CHECKED: DRAWN: STATUS:PERMIT SET REVISIONS NO. DATE BY 1 CLIENT / CITY 2 CITY 3 CITY 4 5 6 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: PERMIT RECEIVED: BID DOCS: CONSTR. DOCS:FAIRYLAND LEARNING CENTER MARYNA MYSKO17630 108TH AVE SE RENTON WA 98055 (425)736-9526ARCHITECT:HEGER ARCHITECTS, INCMILAN HEGER11223 109TH AVE NE KIRKLAND WA 98033 (206)898-6609