HomeMy WebLinkAboutPRE_Pre-Application_Meeting_Summary_180308_v1PRE-APPLICATION MEETING COMMENTS FOR
CHO SHORT PLAT
PRE17000411
CITY OF RENTON
Department of Community & Economic Development
Planning Division
July 20, 2017
Contact Information:
Planner: Clark H. Close, 425-430-7289
Public Works Plan Reviewer: Ann Fowler, 425-430-7382
Fire Prevention Reviewer: Corey Thomas, 425-430-7024
Building Department Reviewer: Craig Burnell, 425-430-7290
Please retain this packet throughout the course of your project as a reference. Consider
giving copies of it to any engineers, architects, and contractors who work on the
project. You will need to submit a copy of this packet when you apply for land use
and/or environmental permits.
Pre-screening: When you have the project application ready for submittal, call and
schedule an appointment with the project manager to have it pre-screened before
making all of the required copies.
The pre-application meeting is informal and non-binding. The comments provided on
the proposal are based on the codes and policies in effect at the time of review. The
applicant is cautioned that the development regulations are regularly amended and the
proposal will be formally reviewed under the regulations in effect at the time of project
submittal. The information contained in this summary is subject to modification and/or
concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director,
Development Services Director, Department of Community & Economic Development
Administrator, Public Works Administrator and City Council).
FIRE & EMERGENCY
SERVICES DEPARTMENT
M E M O R A N D U M
DATE:July 20, 2017
TO:Clark Close, Senior Planner
FROM:Corey Thomas, Plans Review Inspector
SUBJECT:Cho Short Plat
1. The fire flow requirement for a single family home is 1,000 gpm minimum for
dwellings up to 3,600 square feet (including garage and basements). If the dwelling
exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A
minimum of one new fire hydrant is required within 300-feet of the proposed
buildings and two hydrants if the fire flow goes up to 1,500 gpm. A water
availability certificate is required from Soos Creek Water District. It appears that a
minimum of one new fire hydrant would be required to be added to meet
minimum code requirement. The supply main to a new fire hydrant would be at
least 6-inches, Soos Creek will have final design.
2. The fire impact fees are currently applicable at the rate of $718.56 per single family
unit. Credit will granted for the removal of the existing home. Fees paid at time of
building permit issuance.
3. Fire department apparatus access roadways are required to be a minimum of 20-
feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire
access roadways shall be constructed to support a 30-ton vehicle with 75-psi point
loading. Access is required within 150-feet of all points on the buildings. Proposed
access roadway shall be extended northward approximately 45-feet in order to
meet this requirement. Proposed hammerhead turnaround is acceptable and meets
minimum design standards.
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:July 20, 2017
TO:Clark Close, Planner
FROM:Ann Fowler, Civil Engineer II, Plan Review
SUBJECT:Cho Short Plat
11840 SE 192nd St
PRE17-000411
NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-
binding and may be subject to modification and/or concurrence by official City decision-makers. Review
comments may also need to be revised based on site planning and other design changes required by
City staff or made by the applicant.
I have completed a preliminary review for the above-referenced proposal located at parcel(s)
6198400341. The following comments are based on the pre-application submittal made to the City of
Renton by the applicant.
WATER
1. Water service is provided by Soos Creek Water and Sewer District A water availability certificate
from Soos Creek Water and Sewer District is required as part of the Land use Application.
2. The site is located within Zone 2 of an Aquifer Protection Area.
SEWER
1. Wastewater service is provided by Soos Creek Water and Sewer District A sewer availability
certificate from Soos Creek Water and Sewer District is required as a part of the Land use
Application
SURFACE WATER
1. There is no stormwater conveyance system immediately abutting the subject property. The
existing stormwater conveyance system ends on either side of the proposed development and is
within the current City of Kent right-of-way. Applicant will need to coordinate with City of Kent
for any proposed discharge to the City of Kent conveyance systems.
2. A drainage report complying with the current Renton Surface Water Manual (RSWM) will be
required. Based on the City’s flow control map, the site falls within the Flow Control Duration
Standard area matching Forested Site Conditions and is within the Soos Creek Drainage Basin.
Cho Short Plat– PRE17-000411
July 20, 2017
Page 2 of 3
Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the
RSWM.
3. Any proposed detention and/or water quality vault shall be designed in accordance with the
RSWM that is current at the time of civil construction permit application. Separate structural
plans will be required to be submitted for review and approval under a separate building permit
for the detention and/or water quality vault.
4. Appropriate on-site BMPs will be required to help mitigate the new runoff created by this
development. A preliminary drainage plan, including the application of on-site BMPs, shall be
included with the land use application, as applicable to the project. The final drainage plan and
drainage report must be submitted with the utility construction permit application.
5. A Construction Stormwater Permit from Department of Ecology is required if clearing and
grading of the site exceeds one acre.
6. A geotechnical soils report for the site is required per the 2017 Renton Surface Water Design
Manual Section C.1.3. Information on the water table and soil permeability (infiltration rates),
with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C
shall be included in the report. The report should also include information concerning the soils,
geology, drainage patterns and vegetation present shall be presented in order to evaluate the
drainage, erosion control and slope stability for site development of the proposed plat.
7. Surface water system development fee is $1,608.00 for each new lot. This is payable prior to
issuance of the construction permit.
TRANSPORTATION
1. The proposed development fronts SE 192
nd Street along the south property line(s) SE 192nd Street
is within the City of Kent Right-of-Way. Frontage improvements along the property frontage shall
be in accordance with City of Kent design and construction standards.
2. Shared driveways are allowed for access to up to 4 lots provided at least one of the four (4) lots
abuts a public right-of-way with at least fifty (50) linear feet of frontage and the subject lots are
not created by a subdivision of ten (10) or more lots. Refer to the shared driveway requirements
as outlined in RMC 4-6-060J.
3. Current City of Renton standards require a turnaround for dead-end streets greater than 150 feet.
Dead-end streets up to 300 feet may utilize a hammerhead turnaround provided it meets the
requirements for emergency services access, including a 25-ft inside and 45-ft outside turning
radius. Reference RMC 4-6-060H. The hammerhead turnaround shall have a design approved by
the Administrator and Fire and Emergency Services.
4. Frontage improvements along the new public road shall comply with the City’s complete street
standards, including an 8-foot planter strip, 5-foot sidewalk and 0.5-foot curb.
5. Refer to City code 4-4-080 regarding driveway regulations.
a. A minimum separation of 5 feet is required between driveway and the property line.
b. Maximum driveway slopes shall not exceed 15%. Driveways exceeding 8% shall provide
slotted drains.
c. The maximum width of single loaded garage driveway shall not exceed nine feet (9') and
double-loaded garage driveway shall not exceed sixteen feet (16').
6. Street lighting is required from a development that includes more than 4 residential units.
7. Payment of the transportation impact fee is applicable on the construction of the single family
houses at the time of application for the building permit. The current rate of transportation
Cho Short Plat– PRE17-000411
July 20, 2017
Page 3 of 3
impact fee is $5,430.85 per single family house. The transportation impact fee that is current at
the time of building permit application will be levied, payable at building permit issue.
GENERAL COMMENTS
1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property
frontage or within the site must be underground. The construction of these franchise utilities
must be inspected and approved by a City of Renton inspector.
2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the
right-of-way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls.
3. Adequate separation between utilities as well as other features shall be provided in accordance
with code requirements.
a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is
required with the exception of water lines which require 10-ft horizontal and 1.5-ft
vertical.
b. The stormwater line should be minimum 5 feet away from any other structure or wall or
building.
c. Trench of any utility should not be in the zone of influence of the retaining wall or of the
building.
4. All civil construction permits for utility and street improvements will require separate plan
submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil
Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for
the most up-to-date plan submittal requirements:
http://rentonwa.gov/business/default.aspx?id=42473
5. A landscaping plan shall be included with the civil plan submittal. Each plan shall be on separate
sheets.
6. Fees quoted in this document reflect the fees applicable in the year 2017 only and will be assessed
based on the fee that is current at the time of the permit application or issuance, as applicable to
the permit type. Please visit www.rentonwa.gov for the current development fee schedule.
7. A demo permit is required for the demolition of the existing building. The demo permit shall be
acquired through the building department.
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
M E M O R A N D U M
DATE:July 20, 2017
TO:Pre-application File No. 17-000411
FROM:Clark H. Close, Senior Planner
SUBJECT:Cho Short Plat (11840 SE 192nd St)
General: We have completed a preliminary review of the pre-application for the above-
referenced development proposal. The following comments on development and permitting
issues are based on the pre-application submittals made to the City of Renton by the applicant
and the codes in effect on the date of review. The applicant is cautioned that information
contained in this summary may be subject to modification and/or concurrence by official
decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator,
Public Works Administrator, Planning Director, Development Services Director, and City
Council). Review comments may also need to be revised based on site planning and other design
changes required by City staff or made by the applicant. The applicant is encouraged to review
all applicable sections of the Renton Municipal Code. The Development Regulations are
available for purchase for $50.00 plus tax from the Finance Division on the first floor of City Hall
or online at www.rentonwa.gov.
Project Proposal: The subject property is located on the north side of SE 192nd St at 11840 SE
192nd St. The project site totals 44,431 square feet (1.02 acres) in area and is zoned Residential-
4 (R-4). The proposal is to subdivide the project site into four (4) single family residential lots
and one tract located along the western edge of the property (Tract A). An existing residence
and detached sheds are proposed to be removed. Access to each lot would be from the
proposed 20-foot wide shared driveway tract. There is a Wellhead Protection Area zone 2
mapped on the project site. No other critical areas were identified in COR Maps.
Current Use: The property has an existing 1,500 sf single-family residence and associated
detached accessory structure. The existing residence and detached structures are proposed to
be demolished.
Zoning: The area, including this property, has a Comprehensive Plan land use designation of
Residential Low Density (RLD) and is zoned Residential 4 (R-4) dwelling units per acre. The
Residential-4 Zone (R-4) is established to promote urban single family residential neighborhoods
serviceable by urban utilities and containing open space amenities. The R-4 designation serves
as a transition between rural designation zones and higher density residential zones. It is
intended as an intermediate lower density residential zone.
Density Requirements: There is no minimum density requirement. The maximum density
permitted in the R-4 zone is 4.0 dwelling units per net acre (du/ac). Net density is calculated
after the deduction of areas required for public right-of-way dedication, private access
easements, and critical areas from the gross site area.
Cho Short Plat, PRE17-000411
Page 2 of 6
July 20, 2017
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
The area of public and private streets and critical areas would be deducted from the gross site
area to determine the “net” site area prior to calculating density. The pre-application packet
includes a draft survey plat map that indicates that the net acreage would be roughly 39,113
square feet (0.90 acres) with the deduction of the shared driveway tract. The net density was
calculated to be 4.45 du/ac (4 units / 0.90 acres = 4.45 du/ac). Calculations for minimum or
maximum density which result in a fraction that is one-half (0.50) or greater shall be rounded up
to the nearest whole number. Those density calculations resulting in a fraction that is less than
one-half (0.50) shall be rounded down to the nearest whole number. A Density Worksheet
would be required at the time of formal short plat application. The applicant would be
required to demonstrate compliance with the net density requirements of the zone at the time
of formal application. Based on the net density of 4.45 du/ac, the subject site would meet the
maximum net density requirements of the R-4 zone.
Development Standards: The project is subject to RMC 4-2-110A, “Development Standards for
Residential Zoning Designations” effective at the time of complete application (noted as “R-4
standards” herein).
Minimum Lot Size, Width and Depth – The minimum lot size permitted in the R-4 is 9,000 square
feet. The lot sizes proposed would meet this requirement. A minimum lot width of 70 feet is
required for interior lots and 80 feet for corner lots. A lot depth of 100 feet is required. Lots 1-4
appear to comply with the minimum lot width and depth requirements of the zone. It is the
applicant’s responsibility to demonstrate compliance with the minimum lot size, width and
depth criteria of the zone at the time of formal application.
Building Setbacks – Setbacks are the minimum required distance between the building footprint
and the property line and any private access easement. The required setbacks in the R-4 zone
are 30 feet for the front yard, 25 feet for the rear yards, secondary front yard for corner lots
would be required to have a 30 foot setback, and interior side yards are required to have a
combined 20-foot setback with not less than 7.5 feet on either side. The setbacks for the new
residences would be reviewed at the time of short plat decision and applied at the time of
single family building permit.
Building Height – The maximum wall plate height is 32 feet with 3 stories. Roofs with a pitch
equal to or greater than 4:12 may project an additional six (6) vertical feet from the maximum
wall plate height; common rooftop features, such as chimneys, may project an additional four
(4) vertical feet from the roof surface. Non-exempt vertical projections (e.g., decks, railings, etc.)
shall not extend above the maximum wall plate height unless the projection is stepped back
one-and-a-half (1.5) horizontal feet from each façade for each one (1) vertical foot above the
maximum wall plate height. Building height would be verified at the time of building permit
review.
Building Coverage – R-4 zone allows a maximum building coverage of 35% of the lot area.
Building coverage requirements would be verified at the time of building permit review.
Impervious Surface Area – The maximum impervious surface would be limited to 50%.
Impervious surface requirements would be verified at the time of building permit review.
Residential Design and Open Space Standards: All single family residences would be subject to
the Residential Design Standards outlined in RMC 4-2-115. Residential Design Review occurs as
part of the Building Permit Review.
Cho Short Plat, PRE17-000411
Page 3 of 6
July 20, 2017
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
Landscaping: The development standards require that all pervious areas within the property
boundaries be landscaped. Therefore, all areas of the site not covered by structures, required
parking, access, circulation or patios, must be landscaped with native, drought-resistant
vegetative cover. Ten feet (10') of on-site landscaping is required along all public street
frontages, with the exception of areas for required walkways and driveways. In addition, two
trees are required in the front yard setback area of each lot when there are no street trees
within the street right-of-way as referenced in the landscape regulations (RMC 4-4-070F).
Please refer to landscape regulations (RMC 4-4-070) for further general and specific landscape
requirements. A conceptual landscape plan would be required at the time of formal land use
application.
Storm drainage facilities are required to comply with the minimum 15-foot perimeter
landscaping strip on the outside of the fence unless otherwise determined through the site
plan review or subdivision review process. Please refer to landscape regulations RMC 4-4-070
for further general and specific landscape requirements.
Significant Tree Retention: If significant trees (greater than 6-inch caliper or 8-caliper inches for
alders and cottonwoods) are proposed to be removed, a tree inventory and a tree retention
plan along with an arborist report, tree retention plan and tree retention worksheet shall be
provided with the formal land use application as defined in RMC 4-8-120. The tree retention
plan must show preservation of at least 30% of significant trees, and indicate how proposed
building footprints would be sited to accommodate preservation of significant trees that would
be retained (RMC 4-4-130H1.a). When the required number of protected trees cannot be
retained, replacement trees, with at least a two-inch (2") caliper or an evergreen at least six feet
(6') tall, shall be planted at a rate of twelve (12) caliper inches of new trees to replace each
protected tree removed. The Administrator may authorize the planting of replacement trees
on the site if it can be demonstrated to the Administrator's satisfaction that an insufficient
number of trees can be retained.
In addition to retaining 30 percent of existing significant trees, each new lot would be required
to provide a minimum tree density of 2 trees per 5,000 square feet of lot area onsite. Protected
trees that do not contribute to a lot's required minimum tree density shall be held in
perpetuity within a tree protection tract.
Significant trees shall be retained in the following priority order:
Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees
on slopes greater than twenty percent (20%); Significant trees adjacent to critical areas and their
associated buffers; and Significant trees over sixty feet (60') in height or greater than eighteen
inches ( 18") caliper.
Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other
significant native evergreen or deciduous trees; and other significant non-native trees.
Priority Three: Alders and cottonwoods shall be retained when all other trees have been
evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods
are used as part of an approved enhancement project within a critical area or its buffer.
The Administrator may require independent review of any land use application that involves
tree removal and land clearing at the City's discretion. A formal tree retention plan would be
reviewed at the time of Short Plat application.
Cho Short Plat, PRE17-000411
Page 4 of 6
July 20, 2017
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
Fences/Retaining Walls: If the applicant intends to install any fences as part of this project, the
location must be designated on the landscape plan. A wall taller than four feet (4') requires a
building permit. Fences up to six feet (6’) in height are permitted in the rear yard or side yard;
fences up to four feet (4’) are allowed in the front yard. A fence taller than six feet (6') requires a
building permit. A fence shall not be constructed on top of a retaining wall unless the total
combined height of the retaining wall and the fence does not exceed the allowed height of a
standalone fence. New or existing fencing would need to comply with the fence requirements of
the code (RMC 4-4-040).
Retaining walls shall be composed of brick, rock, textured or patterned concrete, or other
masonry product that complements the proposed building and site development. There shall be
a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public
rights-of-way. Please refer to retaining wall standards (RMC 4-4-040) for additional information
about fences and retaining walls. No fences or retaining walls were shown on the submitted
materials.
Access: Access to Lots 1-4 are proposed via a 22-foot wide shared driveway tract (Tract A)
located along the west side of the property. The area of Tract A was identified within the draft
survey plat map as 5,183 square feet. Shared driveways may be allowed for access to four (4) or
fewer residential lots (Per RMC 4-6-060J.1), provided:
a. At least one of the four (4) lots abuts a public right-of-way with at least fifty (50) linear
feet of property; and
b. The subject lots are not created by a subdivision of ten (10) or more lots; and
c. A public street is not anticipated by the City of Renton to be necessary for existing or
future traffic and/or pedestrian circulation through the short subdivision or to serve
adjacent property; and
d. The shared driveway would not adversely affect future circulation to neighboring
properties; and
e. The shared driveway is no more than two hundred feet (200') in length; and
f. The shared driveway poses no safety risk and provides sufficient access for emergency
vehicles and personnel; and
g. Maintenance: The applicant shall ensure the shared driveway can be continually
maintained to minimum standards listed in this section by the owners of the lots served by
the driveway to the satisfaction of the City of Renton, prior to the recording of the short
plat.
h. Covenants, Conditions and Restrictions: Covenants, conditions and restrictions, which are
approved by the Administrator, shall be recorded with the King County Recorder's Office.
The applicant shall provide a copy of the recorded document. These covenants shall provide
for, at a minimum, the following:
i. Maintenance, repair, operation, and payment of taxes for the commonly owned tract
and facilities; and
ii. These covenants shall run with the land and be irrevocable and binding on all the
property owners, including their assigns, heirs, and successors.
Cho Short Plat, PRE17-000411
Page 5 of 6
July 20, 2017
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
Shared driveways shall be within a tract; the width of the tract and paved surface shall be a
minimum of sixteen feet (16') wide; the Renton Fire Authority may require the tract and paved
surface to be up to twenty feet (20') wide. The tract shall be the width of the paved surface plus
eight feet (8') for a landscape strip, when the tract abuts properties that are not part of the
subdivision. The eight-foot (8') landscaping shall include a mixture of trees, shrubs, and
groundcover as required in RMC 4-4-070 and shall serve as a buffer between the shared
driveway and abutting properties that are not part of the subdivision. The shared driveway
would be required to provide a turnaround for dead-end streets greater than 150 feet. A
modification request would need to be granted for any deviations from the street code
standards.
Pipestem lots are not permitted for new plats, unless used to achieve the minimum density
within the Zoning Code when there is no other feasible alternative to achieving minimum
density. The shared driveway tract must extend to the furthest lot of the plat or Lot 4, as shown
in the draft survey plat map.
No sidewalks are required for shared driveways; however, drainage improvements pursuant to
City Code are required (i.e., collection and treatment of stormwater), as well as an approved
pavement thickness (minimum of four inches (4") asphalt over six inches (6") crushed rock). The
maximum grade for the shared driveway shall not exceed fifteen percent (15%), except for
within approved hillside subdivisions. Compliance with driveway standards would be verified at
the time of building permit review.
Parking: Each lot is required to accommodate off street parking for a minimum of two vehicles.
Driveways: The maximum driveway slopes cannot exceed 15%. If the grade exceeds 15%, a
variance is required. The maximum width of single loaded garage driveways shall not exceed 9
feet and double loaded garage driveways shall not exceed 16 feet.
Critical Areas: A Wellhead Protection Area zone 2 is mapped on the project site. If any fill is
proposed, a fill source statement is required. It is the applicant’s responsibility to ascertain
whether any additional critical areas or environmental concerns are present on the site during
site development or building construction.
Additionally, geotechnical studies by licensed professionals, such as a geotechnical engineer
and/or engineering geologist, is required per the 2017 Renton Surface Water Design Manual
Section C.1.3.
Environmental Review: Short Plats of 9 or fewer lots are categorically exempt from
Environmental (SEPA) Review per WAC 197-11.
Permit Requirements: The proposed subdivision would require administrative short plat
approval. The preliminary short plat application would be processed within an estimated time
frame of 6-8 weeks. The short plat fee would be $5,150 ($5,000 Short Plat fee + $150 surcharge
technology fee = $5,150). Detailed information regarding the land use application submittal
items are available on the City’s website. Please note the technology fee is expected to increase
this year. The City has now implemented electronic plan review and no longer accepts paper
submittals. All submittals shall meet Electronic File Standards, which can be found on the
City’s website.
Public Information Sign: The applicant is required to install a proposed land use action sign on
the subject property per the specifications provided within the public information sign handout.
Cho Short Plat, PRE17-000411
Page 6 of 6
July 20, 2017
K:\Preapps\2017\PRE17000411_Cho Short Plat\02.Review Comments
The applicant is solely responsible for the construction, installation, maintenance, removal, and
any costs associated with the sign.
Once Preliminary Short Plat approval is obtained, the applicant must complete the required
improvements and dedications, as well as satisfy any conditions of the preliminary approval
before submitting for Final Short Plat review. Once final approval is received, the plat may be
recorded. The newly created lots may only be sold after the plat has been recorded.
Fees: In addition to the applicable building and construction fees, impact fees would be required
for new single family homes. Such fees would apply to all projects and would be calculated at
the time of building permit application and payable prior to building permit issuance. The 2017
application fees are as follows:
A Transportation Impact Fee based on $5,430.85 per each new single family residence;
A Parks Impact Fee based on $2,740.07 per each new single family residence;
A Fire Impact fee of $718.56 per each new single family residence; and
Renton School District Impact Fee is $6,432.00 per each new single family residence.
A handout listing Renton’s development-related fees is available on the City of Renton website
for your review.
Next Steps: When the formal application materials are complete, the applicant is strongly
encouraged to have the application materials pre-screened at the 6th floor front counter prior
to submitting the complete application package. Please call Clark Close, Senior Planner at 425-
430-7289 or cclose@rentonwa.gov to schedule an appointment.
Expiration: Upon approval, the short plat is valid for two (2) years with a possible one (1) year
extension (RMC 4-7-070M). It is the responsibility of the subdivider to monitor the expiration
date.
L
L
6
/
1
9
/
2
0
1
7
1,600
133
COR Maps
This map is a user generated static output from an Internet mapping site and
is for reference only. Data layers that appear on this map may or may not be
accurate, current, or otherwise reliable.
Cho Short Plat
7/19/2017
Legend
91045
THIS MAP IS NOT TO BE USED FOR NAVIGATION
Feet
Notes
91
WGS_1984_Web_Mercator_Auxiliary_Sphere
Information Technology - GIS
RentonMapSupport@Rentonwa.gov
City and County Boundary
Other
City of Renton
Addresses
Parcels
Human Services
Sites of Interest
Hospital / Medical Center
Light Rail Station
Park and Ride
Parking Lot
Bus Station / Dispatch Facility
Amusement / Water Park
Library
Museum
Fire Station / EMS Station
Urgent Care Facility
Post Office
Historic Site / Point of Interest; Cemetery
Park or Open Space
Golf Course
Sports Arena / Stadium
School
Shopping Mall / Complex
Airport Runway / Airfield
Licensed Businesses