HomeMy WebLinkAboutF_Final_Zoning_Drawings_LDC_180222_v1PROPERTY OWNER:
BOEING LAKESHORE LANDING - BSP LOT 1 OF RENTON
SHORT PLAT #LUA-06-069-SHPL REC #20061024900005 SD SP
BEING LOT 3A OF RENTON LLA LUA-06-004 REC
#20060510900003 TGW TR N BOEING BSP 20041223000856
LEGAL DESCRIPTION
APPROVED BY
CONSTRUCTION MANAGER
DATE SIGNATURE
PROJECT MANAGER
SITE ACQUISITION
ZONING
APPROVAL / SIGN OFF
PROJECT CONTACT LIST
PROJECT INFORMATION
RF
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
FROM VERIZON WIRELESS OFFICE:
x GET ON I-90 W FROM SE EASTGATE WAY
x HEAD EAST TOWARD 158TH AVE SE
x TURN RIGHT ONTO 158TH AVE SE
x TURN RIGHT ONTO SE EASTGATE WAY
x TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE
x KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE
ONTO I-90 W
x TAKE I-405 S TO NE PARK DR IN RENTON. TAKE EXIT 5 FROM I-405
S
x MERGE ONTO I-90 W
x TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON
x MERGE ONTO I-405 S
x TAKE EXIT 5 TOWARD WA-900 E/PARK AVENUE NORTH/SUNSET
BLVD N.E
x DRIVE TO GARDEN AVE N
x TURN RIGHT ONTO NE PARK DR (SIGNS FOR PARK AVENUE N)
x TURN LEFT ONTO GARDEN AVE N
x TURN RIGHT ONTO N 10 ST
x TURN LEFT ONTO PARK AVE N
x DESTINATION WILL BE ON THE LEFT
x
DRIVING DIRECTIONS
VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNED
TELECOMMUNICATIONS FACILITY CONSISTING OF (6) PANEL ANTENNAS,
(6) RRUS UNITS, AND (2) OVP DISTRUBUTION BOXES CONCEALED
WITHIN (2) SHROUDED ANTENNA MOUNTS; ALSO, THE ADDITION OF (2)
MICROWAVE ANTENNAS WITHIN AN FRP CANISTER ASSEMBLY
MOUNTED ON A 38.0'BUILDING.
MICROWAVE
(NEW)
TELEPHONE:POWER:
PUGET SOUND ENERGY
PHONE: (888) 225-5773ZONING CLASSIFICATION:
CODE INFORMATION:
UC (URBAN CENTER)
BUILDING CODE:IBC 2015
CONSTRUCTION TYPE:IIIA
OCCUPANCY:B, M, S-2
JURISDICTION:CITY OF RENTON
PROPOSED BUILDING USE: UNMANNED TELECOM
LATITUDE:
SITE LOCATION (NAD83):
47° 29' 50.14" N
LONGITUDE:122° 12' 06.76" W
TOP OF STRUCTURE:68.00'± AMSL
BASE OF STRUCTURE:30.00'± AMSL
TBD
PROJECT LEASE AREA:
0886600029
PARCEL NUMBER:
4.77 ACRES
AREA OF PARCEL:
N/A
NEW IMPERVIOUS AREA:
1. PARKING REQUIREMENTS ARE UNCHANGED.
2. TRAFFIC IS UNAFFECTED.
3. SIGNAGE IS UNAFFECTED.
GENERAL INFORMATION:
PROJECT DESCRIPTION:
38.0'± AGL
0.0' AGL
(47.4972619° N)
(122.2018766° W)
VICINITY MAP
NOT TO SCALE
GENERAL LOCATION MAP
NOT TO SCALE
PROJECTPROJECT
TITLE SHEET
T-1.0
LANDLORD
960 PARK AVE N
RENTON, WA 98057
SEA RETAIL RENTON
DRAWING INDEX
DWG NO.DESCRIPTION
T-1.0 TITLE SHEET
A-1.0 SITE PLAN
A-2.0 ENLARGED SITE PLAN
A-3.0 ELEVATIONS
CPR THE LANDING LLC
APPLICANT:
VERIZON WIRELESS
3245 158TH AVENUE SE
BELLEVUE, WA 98008
PROJECT ARCHITECT:
LDC, INC.
CONTACT: RICHARD B. HALL, AIA
PHONE: (425) 806-1869
EMAIL: rhall@ldccorp.com
PROJECT CONSULTANT:
LDC, INC.
CONTACT: RICK CARDOZA
PHONE: (253) 218-9017
EMAIL: rcardoza@ldccorp.com
UTILITY COMPANIES
THE INFORMATION CONTAINED IN THIS SET OF
CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.
ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY
PROHIBITED.
PROPRIETARY INFORMATION
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION.
LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF
TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING.
CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL
RESPONSIBILITY FOR MOUNTING PRODUCTS USED &
THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE
FOR ILLUSTRATIVE PURPOSES ONLY.
DISCLAIMERS
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA RETAIL RENTON
960 PARK AVE N
RENTON, WA 98057
8-29-17
RJG
RBH
1 8-29-17 PRELIMINARY ZONING RJG
2 9-13-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
RECEIVED
02/27/2018
amorganroth
PLANNING DIVISION
1
1
ZONING:
ADJACENT ZONING:
ZONING MAP
NOT TO SCALE
SITE PLAN
22"x34" SCALE: 1" = 50'11"x17" SCALE: 1" = 100'
PROJECT
EXISTING SITE ACCESS
SITE PLAN
A-1.0
UC (URBAN CENTER)
UC (URBAN CENTER)
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA RETAIL RENTON
960 PARK AVE N
RENTON, WA 98057
8-29-17
RJG
RBH
1 8-29-17 PRELIMINARY ZONING RJG
2 9-13-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM
PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. LDC HAS NOT
COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIM AS
TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET.
PROPOSED VERIZON WIRELESS
ANTENNAS MOUNTED WITHIN A FRP
SHROUD ON A 38.0' BUILDING
ADJACENT ZONING:
UC (URBAN CENTER)
ADJACENT ZONING:
IH (INDUSTRIAL HEAVY)
ADJACENT ZONING:
UC (URBAN CENTER)
UC
UC
UC IH
16'± ANTENNASETBACK
1 0 9 '±A N T E N N A
S E T B A C K
5 5 3 '±
A N T E N N A
S E T B A C K
1
8
7
'
±
A
N
T
E
N
N
A
S
E
T
B
A
C
K
1
1
ENLARGED SITE PLAN
22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0"
MW:288°
M
W
:
1
4
5
°
ENLARGED SITE PLAN
A-2.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA RETAIL RENTON
960 PARK AVE N
RENTON, WA 98057
8-29-17
RJG
RBH
1 8-29-17 PRELIMINARY ZONING RJG
2 9-13-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2. ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS HYBRID FIBER CABLE TO ANTENNAS
(2 TOTAL).
PROPOSED VERIZON WIRELESS SHROUDED ANTENNA MOUNT
(2 TOTAL). STRUCTURAL PENDING.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 3 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS GPS ANTENNA.
PROPOSED VERIZON WIRELESS 1'Ø MICROWAVE (2 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP BOX
(2 TOTAL).
EXISTING 38.0' BUILDING.
PROPOSED VERIZON WIRELESS WALL MOUNTED STEEL ANGLE.
PROPOSED VERIZON WIRELESS RRUS 32 UNIT
(TYP 3 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS CABLE SUPPORT BLOCKS.
PROPOSED VERIZON WIRELESS 3'Ø x 6' TALL FRP CANISTER ASSEMBLY.
STRUCTURAL PENDING.
3
4
6
7
11
12
14
17
20
26
29
2
4
EXISTING PARKING LINE,
TYP (TO REMAIN)
ROOF DECK
EXISTING BUILDING
CANOPY OVERHANG
11
21 7
2 2 '-0 "
19'-0"
EXISTING BUILDING
CANOPY OVERHANG
12
P R O P O S E D
V E R I Z O N
W I R E L E S S
1 0 '-0 "
A N T E N N A
S H R O U D
PROPOSED
VERIZON
WIRELESS
10'-0" ANTENNA
SHROUD
P R O P O S E D
V E R I Z O N
W I R E L E S S
8 '-0 "
A N T E N N A
S H R O U D
PROPOSED
VERIZON
WIRELESS
8'-0"
ANTENNA
SHROUD
5 '-0 "
5'-0"5'-0"
5 '-0 "
29 3
17
14
6
6
6
6
S E C T O R 1 :6 0 °
S E C T O R 3 :2 4 0 °
S
E
C
T
O
R
2
:
1
5
0
°
14
17
2
1PROPOSED SOUTH ELEVATION (LOOKING NORTH)
22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0"
PROPOSED WEST ELEVATION (LOOKING EAST)
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/16" = 1'-0"
0.0' AGL
28.0' AGL
TOP OF PARAPET
25.0' AGL
FINISH GRADE
0.0' AGL
ELEVATIONS
A-3.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
SEA RETAIL RENTON
960 PARK AVE N
RENTON, WA 98057
8-29-17
RJG
RBH
1 8-29-17 PRELIMINARY ZONING RJG
2 9-13-17 FINAL ZONING ENS
APPROVAL STAMP
Structural
Engineering
Architectural
www.LDCcorp.com
20210 142nd Ave NE
Woodinville, WA 98072
THE CIVIL ENGINEERING GROUP
Fx. 425.482.2893
Ph. 425.806.1869
Survey
8828
CONSTRUCTION PLAN KEYED NOTES
1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2. ANALYSIS OF BUILDING SHALL BE PERFORMED BY LDC & STAMPED BY
A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS SHROUDED ANTENNA MOUNT
(2 TOTAL). STRUCTURAL PENDING.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 3 PER SECTOR, 6 TOTAL).
PROPOSED VERIZON WIRELESS 1'Ø MICROWAVE (2 TOTAL).
EXISTING 38.0' BUILDING.
PROPOSED VERIZON WIRELESS 3'Ø x 6' TALL FRP CANISTER ASSEMBLY.
STRUCTURAL PENDING.
4
6
7
11
12
FINISH GRADE
27.5' AGL
TOP OF LOWER PARAPET
22.0' AGL
TOP HEIGHT OF PROPOSED
VERIZON WIRELESS CANISTER
28.0' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS MICROWAVES
27.5' AGL
TOP OF PARAPET
25.0' AGL
4
4
11
7
7
11
TOP OF BUILDING
38.0' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS MICROWAVES
TOP HEIGHT OF PROPOSED
VERIZON WIRELESS CANISTER
TOP OF LOWER PARAPET
22.0' AGL
TOP OF BUILDING
38.0' AGL
12
6
6
12
33.0' AGL
32.5' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
TOP HEIGHT OF PROPOSED
VERIZON WIRELESS SHROUD
33.0' AGL
32.5' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
TOP HEIGHT OF PROPOSED
VERIZON WIRELESS SHROUD
TOP OF ROOF DECK
19.0' AGL
30.0' AGL
29.5' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
TOP HEIGHT OF PROPOSED
VERIZON WIRELESS SHROUD
TOP OF ROOF DECK
19.0' AGL