No preview available
HomeMy WebLinkAboutP_Plan Set_171121_v1BURL N ORILLIA IND PK RENTON #1 PARCEL B OF CITY OF RENTON SHORT PLAT NO 094-85 RECORDING NO 8602269002 SD SHORT PLAT DAF - LOT 1 BLK 1 OF BURLINGTON NORTHERN ORILLIA INDUSTRIAL PARK OF RENTON DIV NO 1 PLAT BLOCK: 1 PLAT LOT: 1 LEGAL DESCRIPTION APPROVED BY CONSTRUCTION MANAGER DATE SIGNATURE PROJECT MANAGER SITE ACQUISITION ZONING APPROVAL / SIGN OFF PROJECT CONTACT LIST PROJECT INFORMATION UTILITY COMPANIES RF LDC, INC. CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 EMAIL: rhall@ldccorp.com PROJECT ARCHITECT: APPLICANT:PROPERTY OWNER: REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED FROM VERIZON WIRELESS OFFICE: x HEAD SOUTH ON 160TH AVE SE x TURN LEFT ONTO SE EASTGATE WAY x TURN RIGHT ONTO THE SEATTLE W/SEATTLE RAMP x KEEP LEFT TO CONTINUE TOWARD I-90 W x MERGE ONTO I-90 W/SEATTLE x USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON x MERGE ONTO I-405 S x TAKE EXIT 2A TO MERGE ONTO WA-167 S TOWARD KENT/AUBURN x PARTS OF THIS ROAD MAY BE CLOSED AT CERTAIN TIMES OR DAYS x TAKE THE E VALLEY RD EXIT TOWARD SOUTHWEST 43RD STREET x TURN RIGHT ONTO E RAINIER AVE S/E VALLEY RD x DESTINATION WILL BE ON THE LEFT x SITE IS LOCATED AT SW CORNER OF PROPERTY BEHIND BUILDING WITH ACCESS FROM THE SOUTH DRIVING DIRECTIONS PROJECT CONSULTANT: VERIZON WIRELESS 3245 158TH AVENUE SE BELLEVUE, WA 98008 VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF A CELL ON WHEELS (COW) WITH (3) PANEL ANTENNAS, (1) MICROWAVE W/ (2) ODU'S, AND (16) CABLES, AND MOBILE GENERATOR WITHIN A TEMPORARY FENCED COMPOUND BEHIND AN EXISTING BUILDING. MICROWAVE (ON SITE) FIBER:POWER: TBD ZONING CLASSIFICATION: CODE INFORMATION: IM (INDUSTRIAL-MEDIUM) BUILDING CODE:IBC 2015 CONSTRUCTION TYPE:IIB OCCUPANCY:U, S-2 JURISDICTION:CITY OF RENTON PROPOSED BUILDING USE: UNMANNED TELECOM LATITUDE: SITE LOCATION (NAD83): 47° 27' 16.54" N LONGITUDE:122° 13' 10.00" W TOP OF STRUCTURE:43.00'± AMSL BASE OF STRUCTURE:15.00'± AMSL TBD PROJECT LEASE AREA: 125380-0015 PARCEL NUMBER: 2.26 ACRES AREA OF PARCEL: N/A NEW IMPERVIOUS AREA: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS UNAFFECTED. GENERAL INFORMATION: PROJECT DESCRIPTION: 28.0'± AGL 0.0' AGL (47.454595° N) (122.219444° W) VICINITY MAP NOT TO SCALE GENERAL LOCATION MAP NOT TO SCALE PROJECT PROJECT FLASHERS LLC 2701 EAST VALLEY RD RENTON, WA 98055 TITLE SHEET T-1.0 LANDLORD 2701 EAST VALLEY RD RENTON, WA 98055 RENTON INDUSTRIAL COW DRAWING INDEX DWG NO.DESCRIPTION T-1.0 TITLE SHEET A-1.0 SITE PLAN A-2.0 ENLARGED SITE PLAN A-3.0 ELEVATIONS SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV RENTON INDUSTRIAL COW 2701 EAST VALLEY RD RENTON, WA 98055 10-31-17 JDM RBH 1 10-31-17 PRELIMINARY ZONING JDM 2 11-3-17 RPZD: ADD RF DESIGN JDM 3 11-8-17 RPZD: NEW TIP HEIGHTS JDM 4 11-14-17 RPZD: MOVE SITE NORTH RJG 5 11-29-17 FINAL ZONING KTL Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 LDC, INC. CONTACT: RICK CARDOZA PHONE: (253) 218-9017 EMAIL: rcardoza@ldccorp.com PROPRIETARY INFORMATION DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING. CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL RESPONSIBILITY FOR MOUNTING PRODUCTS USED & THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. DISCLAIMERS THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. RECEIVED 12/29/2017 amorganroth PLANNING DIVISION 1 1 ZONING: IM (INDUSTRIAL-MEDIUM) ZONING MAP NOT TO SCALE SITE PLAN 22"x34" SCALE: 1" = 30'11"x17" SCALE: 1" = 60' PROJECT EXISTING SITE ACCESS SITE PLAN A-1.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV RENTON INDUSTRIAL COW 2701 EAST VALLEY RD RENTON, WA 98055 10-31-17 JDM RBH 1 10-31-17 PRELIMINARY ZONING JDM 2 11-3-17 RPZD: ADD RF DESIGN JDM 3 11-8-17 RPZD: NEW TIP HEIGHTS JDM 4 11-14-17 RPZD: MOVE SITE NORTH RJG 5 11-29-17 FINAL ZONING KTL Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 PROPOSED VERIZON WIRELESS ANTENNAS & MICROWAVE MOUNTED ON A CELL ON WHEELS (COW) WITH MOBILE GENERATOR WITHIN A TEMPORARY FENCED COMPOUND ADJACENT ZONING: CA (COMMERCIAL ARTERIAL) ADJACENT ZONING: IL (INDUSTRIAL-LIGHT) IM CA IL PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. LDC HAS NOT COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIM AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. ADJACENT ZONING: IM (INDUSTRIAL-MEDIUM) ADJACENT ZONING: IM (INDUSTRIAL-MEDIUM) 10'± TOWER SETBACK 59'± TOWER SETBACK 272'±TOWER SETBACK 2 9 2 '± T O W E R S E T B A C K PROPOSED VERIZON WIRELESS METERBASE AND SERVICE DISCONNECT WITHIN AN EXISTING BUILDING PROPOSED VERIZON WIRELESS POWER SERVICE ORIGINATING FROM AN EXISTING DISTRIBUTION PANEL WITHIN AN EXISTING BUILDING TO PROPOSED METER BASE W/ SERVICE DISCONNECT BEFORE EXITING AND CONTINUING UNDERGROUND TO PROPOSED CELL ON WHEELS EXISTING BUILDING ACCESS EXISTING SITE ACCESS FROM PARKING LOT EXISTING BUILDING ACCESS 10'-0" 1 1 ENLARGED SITE PLAN 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" EXISTING SITE ACCESS B .N . R A I L R O A D ENLARGED SITE PLAN A-2.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV RENTON INDUSTRIAL COW 2701 EAST VALLEY RD RENTON, WA 98055 10-31-17 JDM RBH 1 10-31-17 PRELIMINARY ZONING JDM 2 11-3-17 RPZD: ADD RF DESIGN JDM 3 11-8-17 RPZD: NEW TIP HEIGHTS JDM 4 11-14-17 RPZD: MOVE SITE NORTH RJG 5 11-29-17 FINAL ZONING KTL Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 CONSTRUCTION PLAN KEYED NOTES 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. SITE NOTES PROPOSED UNDERGROUND POWER ROUTING. PROPOSED TEMPORARY 6'-0" TALL CHAIN LINK FENCE. PROPOSED TEMPORARY CHAIN LINK ACCESS GATE W/ LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE. PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14'). PROPOSED VERIZON WIRELESS ANTENNA MAST MOUNT. PROPOSED VERIZON WIRELESS PANEL ANTENNA (3 TOTAL). PROPOSED VERIZON WIRELESS 2'Ø MICROWAVE W/ (2) ODU'S & (4) CAT5E CABLES (1 TOTAL). PROPOSED VERIZON WIRELESS EQUIPMENT CABINET. EXISTING BUILDING. PROPOSED VERIZON WIRELESS MOBILE DIESEL GENERATOR. PROPOSED VERIZON WIRELESS RRUS UNIT WITH PROPOSED EQUIPMENT CABINET (TYP 2 PER SECTOR, 6 TOTAL). 2 4 5 6 9 10 11 12 21 24 31 P R O P O S E D V E R I Z O N W I R E L E S S 1 4 '-0 " C E L L O N W H E E L S PROPOSED VERIZON WIRELESS 6'-0"CELL ON WHEELS 2 2 5 TOOL BOX AC PANEL (BELOW) COW OUTRIGGERS, TYP SECTOR1 :100° 21 EXISTING BUILDING ACCESS DOOR 7'-0"7'-0" EXISTING RAILROAD TRACKS 31 6 11 12 GRASS 1 6 0 '-0 "± T O P R O P O S E D S E R V I C E D I S C O N N E C T PROPOSED 20'-0"TEMPORARY FENCED COMPOUND MW :272.19° 4 '-7 " 4 '-6 " 4 '-0 " 7 '-1 1 " 5'-0"5'-0" S E C T O R 2 :2 0 5 ° 2 4 P R O P O S E D 3 5 '-0 "T E M P O R A R Y F E N C E D C O M P O U N D S E C T O R 3 : 3 1 5° 9 9 10 4 7'-0" 6'-5"6'-6" 24 1 4 '-0 " 7 '-1 0 " 1PROPOSED WEST ELEVATION (LOOKING EAST) 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" TOP OF EXISTING BUILDING 28.0' AGL TIP HEIGHT OF PROPOSED VERIZON WIRELESS ANTENNAS ELEVATIONS A-3.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV RENTON INDUSTRIAL COW 2701 EAST VALLEY RD RENTON, WA 98055 10-31-17 JDM RBH 1 10-31-17 PRELIMINARY ZONING JDM 2 11-3-17 RPZD: ADD RF DESIGN JDM 3 11-8-17 RPZD: NEW TIP HEIGHTS JDM 4 11-14-17 RPZD: MOVE SITE NORTH RJG 5 11-29-17 FINAL ZONING KTL Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 CONSTRUCTION PLAN KEYED NOTES 1. VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. SITE NOTES PROPOSED TEMPORARY 6'-0" TALL CHAIN LINK FENCE. PROPOSED VERIZON WIRELESS COAX CABLE TO ANTENNAS, TYP (12 TOTAL). PROPOSED VERIZON WIRELESS CELL ON WHEELS (6'x14'). PROPOSED VERIZON WIRELESS ANTENNA MAST MOUNT. PROPOSED VERIZON WIRELESS PANEL ANTENNA (3 TOTAL). PROPOSED VERIZON WIRELESS 2'Ø MICROWAVE W/ (2) ODU'S & (4) CAT5E CABLES (1 TOTAL). EXISTING BUILDING. PROPOSED VERIZON WIRELESS MOBILE DIESEL GENERATOR. PROPOSED VERIZON WIRELESS RRUS UNIT WITH PROPOSED EQUIPMENT CABINET (TYP 2 PER SECTOR, 6 TOTAL). 2 4 6 9 11 12 14 24 31 645.0' AGL 4 31 FINISH GRADE 0.0' AGL EXISTING ACCESS DOOR EXISTING LIGHT, TYP EXISTING SCUPPER & DRAIN, TYP PROPOSED VERIZON WIRELESS 35'-0" TEMPORARY FENCED COMPOUND 242 9 11 6 RAD CENTER OF PROPOSED VERIZON WIRELESS MICROWAVE 35.0' AGL 14 12