HomeMy WebLinkAboutP_Mechanical_Plan_vin deli 8_20171220_V1SITE / ROOF PLAN
SCALE: 14" = 1'
NORTH ADJACENT TENANT(UNDER SAME PARCEL) JOBSITE
EF MUA
TYPE 1 HOOD
(18 GA. STAINLESS STEEL)
<4'(W) x 8'(L)> ADJACENT PROPERTY (UNDER DIFFERENT PARCEL) MIN. 10' ADJACENT TENANT(UNDER SAME PARCEL) VINCINITY MAP
SCALE: NTS
NORTH
EXHAUSTFANEXHAUST HINDGE KIT
INSTALLATION
HINDGE
BRACKET
THREADED
CABLE
GREASE
DUCT
ROOF
CURB
ROOF LINE
1'-6"
EXHAUST
FAN
1'-4"
MAKE UP
AIR
MIN. 10'
24 GA. GALVANIZE
MAKE UP DUCT
20 GA.
FLASHING
4" x 4" P.T.
SLEEPERS
1'-2"
1'-2"
20 GA.
FLASH
3M #615+
FIREWRAP
FRONT VIEW
SCALE: 12 = 1'
SUSPENDED "T" BAR CEILING
16" x 16" ALL AROUND
CONTINUOUS TIGHT
WELDED GREASE
DUCT (16 GA.
GALVANIZE STEEL)
3/8" THREADED
STEEL ROD
(FRONT SUPPORT)
8"
12 GA. UNISTRUT
10'
3'-4"
SEE1.2
FAN EQUIPMENT SCHEDULE
UNIT BRAND
NAME MODEL #CFM
(REQUIRED)
HORSE
POWER S.P.ELECTRICAL
(VOLTAGE)/(PHASE)
WEIGHT
(LBS)d.B.A.
EXHAUST
FAN DAYTON 5PV07 2,400 1 0.75"(115/208-230)/(1PH)145 65 d.B.A.
MAKE UP
AIR ESSIK 7AC30 2,160 13 0.3"(115-230)/(1 PH)137 63 d.B.A
8'
1
1'-6"
16'-734"
1'-6"
GK-M THERMAFLEX AIR DUCT
3
2
4
EQUIPMENT
1. TYPE 1 HOOD SYSTEM <4'(W) x 8'(L)>
2. DEEP FRYER <16"(W) x 43"(H)>
3. 4 BURNER RANGE <24"(W) x 56"(H)>
4. RADIANT BROILER <24"(W) x 14"(H)>
5. STOCK POT RANGE <18"(W) x 20"(H)>
MIN. 6"MIN. 6"
5
SCOPE OF WORK:
INSTALL ONE 8' COMMERICAL KITCHEN (TYPE 1) GREASE HOOD,
ONE EXHAUST FAN, ONE MAKE UP AIR UNIT, & RELATED DUCT
WORK FOR BOTH FANS
PROJECT INFORMATION:
TENANT: VIN DELI
241 SUNSET BLVD N
RENTON, WA 98057
PARCEL # 172305-9090
PROPERTY OWNER: WINDSOR PARK ESTATES RENTON
LEGAL DESCRIPTION: BEG INTSN NLY MGN BRONSON WAY N WITH
WLY MGN STATE HWY # 2 TH N 22-44-31 E ALG HWY 541.93 FT TO
TRUE BEG TH CONTG N 22-44-31 E 137.98 FT TH N 67-15-29 W TO
ELY MGN P C R/W TH SLY ALG SD R/W TO PT N 67-15-29 W FR TRUE
BEG TH S 67-15-29 E TO TRUE BEG
NOTES:
1. THE EXHAUST FAN & MAKE UP AIR SYSTEM WILL BE
CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH
FOR SAME TIME OPERATION.
2. ALL EQUIPMENT SHOWN ON THIS DRAWING SHALL
BE AS SPECIFIED OR EQUAL.
3. THE PROPOSED WALL TO BE CONSTRUCTED TO MEET THE FIRE
CODES FOR TYPE 1 HOOD (1 HR. FIRE RESISTIVE SHIELD).
4. STAINLESS STEEL SHEET SHALL COVER THE ENTIRE
COOKING AREA.
5. ALL HOOD, DUCT JOINS, & SEAMS SHALL BE EXTERNAL
GREASE TIGHT WELD.
6. EXHAUST FAN SHALL BE 40" (MIN.) DISCHARGE ABOVE ROOF.
7. MIN. DISTANCE BETWEEN EXHAUST FAN & MAKE UP AIR
SHALL BE NO LESS THAN 10'.
8. FIRE SUPPRESSION SYSTEM WILL BE UNDER SEPERATE PERMIT.
SECTION ELEVATION VIEW
SCALE: NTS
18 GA. STAINLESS
STEEL TYPE I
GREASE HOODGREASE
GUTTER
FILTER
3" STAINLESS STEEL
(20 GA.) STAND OFF
STAINLESS STEEL
WALL w/ ROXUL
AFB 1" FIRE PAD
FLOOR
4'
ALL AROUND
CONTINUOUS LIQUID
TIGHT WELD
BETWEEN DUCT AND
HOOD SYSTEM
2" METAL
WALL FRAME
LIGHT
24 GA. GALVANIZE
MAKE UP AIR DUCT
58" TYPE "X"
FIRE RATED
SHEET ROCK
ALL AROUND
CONTINUOUS TIGHT
WELDED 16 GA.
GALVANIZE DUCT
FIREWRAP
6'-6"
COOKING
EQUIPMENT
3'-9"
3" AIR SPACE
12" THREADED
STEEL ROD
(FRONT SUPPORT)
20 GA. FLASHING
SEE 1.1
MAKE UP
AIR VENTS
EXISTING WOOD
FRAME
4
5
32 61
7
1 2 LAYER FIREMASTER DUCT WRAP
2 FILAMENT TAPE
3 BANDING
4 3" PERIMETER OVERLAP
5 3" LONGITUDINAL OVERLAP
6 1/2" DIAMETER HANGER ROD
7 1 1/2" x 1 1/2" x 1/8" ANGLE
1 OR 2 HOUR SHAFT ALTERNATIVE & ZERO
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
FIREMASTER GREASE DUCT SYSTEM:
212" Lo Root Lubricized
Round Washer Recex Screw
I NTERTEK
LIST E D
16 GA. GALVANIZE
HOOD BRACKET
112" Hex. Washer Self Drill Screw
Part #: 50943 No. 14 (Non-Combustible)
20 GA. STAINLESS
STEEL TYPE 1
GREASE HOOD
EXHAUST
SECTION
MAKE UP AIR
SECTION
BRACKET
WELDED
ONTO HOOD
3/8" THREADED
STEEL ROD
12 GA. "U" CHANNEL
BAR SUPPORT
3" STAND OFF
S/S FLASHING
(B) 1.5" METAL FASTENERS
BETWEEN HOOD &
SUPPORT BRACKET
TYPICAL UNISTRUT HOOD SUPPORT DETAILS
(C) 16 GA. GALVANIZE
SUPPORT BRACKET
3" No. 10 METAL FASTENERS
BETWEEN WALL STUD &
SUPPORT BRACKET
(ON CENTER OFF FRAMING STUDS)
(A) 2.5" METAL FASTENERS
BETWEEN S/S WALL &
WALL FRAME
NON-
COMBUSTIBLE
WALL FRAME
VIN DELI 241 SUNSET BLVD N. RENTON, WA 98057GREAT SUN CORP.Restaurant Equipment, Supplies, & Metal Fabrication State License # GREATSC951D1505 S. Lander St.Seattle, WA 98134www.greatsuncorp.comGSGSGSGSGREAT SU N
C O R PORATIONSHEET NUMBERCONTRACTOR:PROJECT PROPOSED FOR:1.1
B
C
A
1.2
JOBSITE PARKING AREAPR17000635
M17006003
RECEIVED
12/20/2017 lwalker
BUILDING DIVISION
PROVIDE MFR. INSTALLATION INFORMATION
TO THE FIELD DURING INSPECTION.
TEMPERED
TEMPERED UNIT
APPROVED
BUILDING DIVISION
THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL
TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE
OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON
BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF
OCCUPANCY.
APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO
VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES,
OR OTHER REGULATIONS ENFORCED BY THIS CITY.
DATE: 01/08/2018