Loading...
HomeMy WebLinkAboutP_Site Plan_230706_South Seattle Gate Station_V1Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO. Ennis, TX 75119 3309 S. Interstate 45 972-878-7000 Fax: 214-887-4552 Toll: 888-650-4766 www.Guardiar.com PUGET SOUND ENERGY SOUTH GATE STATION #2724 SUBMITTAL DATE: 01 SEPTEMBER, 2023 RENTON, WA PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED1.00TITLE SHEET-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL FS7339 GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.SOUTH GATE STN8'H, GUARDIAN 1000, SECURIFOR 4DR31.00 MINIMUM SOIL BEARING CAPACITY: 2,500 PSF ULTIMATE WIND SPEED: 98MPH, CAT. II, EXP. C.PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED1.01INDEX SHEET-MINIMUM CONCRETE STRENGTH: 3,000 PSI WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY. DESIGN CRITERIA Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR31.01ROUND STEEL POSTS: SQUARE / RECT. STEEL POSTS & BEAMS: BRACKET / PLATE / ANGLE STEEL: STANDARD MATERIAL SPECIFICATIONS MATERIALS ARE SUPPLIED ACCORDING TO THE FOLLOWING SPECIFICATIONS UNLESS NOTED OTHERWISE SQUARE RAILS (STEEL): PREGALVANIZED MATERIAL TO CONFORM TO ASTM A653 w/ MINIMUM ZINC COATING WEIGHT 0.60 OZ/FT² HOT DIP GALVANIZED MATERIAL TO CONFORM TO ASTM A123 FINISH SPECIFICATIONS UNIONS (ALUMINUM): ALUMINUM GATE FRAME MEMBERS: POWDERCOAT MINIMUM THICKNESS: 2mm ASTM A500 GRADE B ASTM A53 GRADE B ASTM A36 ASTM A513 AL6063-T5 AL6061-T6 ROUND RAILS (SS30/SS40): ASTM F1043 SHEET INDEX SHEET DESCRIPTION 1.00 TITLE SHEET01-SEP-23R3 DATEREV. 1.01 INDEX SHEET 2.00 SITE LAYOUT 3.00 8'H SECURIFOR 4D TYPICAL ELEVATION 4.00 GUARDIAN 1000 TYPICAL DETAILS 5.00 5.20 20'W X 8'H DBL SWING GATE TYPICAL 6.00 NOT USED 9.00 HARDWARE 8.00 UNIONS & JIG 7.00 TYPICAL POST DETAIL 3.01 TYPICAL ELEVATION FOLLOWING SLOPE 4'W X 8'H MAN GATE TYPICAL ASCE 7-16 5.10 12'W X 8'H DBL SWING GATE TYPICAL 3.01 TYPICAL ELEVATION TRANSITION TO WALL R3 R3 07-JUL-23R2 07-JUL-23R2 07-JUL-23R2 01-SEP-23 01-SEP-23 G G G G G G G G PF P P P PPPPPP P P P P P P P PP PPPPPP P P P P P PP P P PPPFOCULVERT 4" CPP W IE=199.3 G G G G G G G G G G G G G G GG GG G G G G G G G G G G G EXPOSED FUEL PIPES ELECTRICAL CABINET P G G FO FOFOEXPOSED FUEL PIPE CUSTOMER TO VERIFY ALL DIMENSIONS GATE#WIDTH/HEIGHT REMARKS GATE SCHEDULE 20'W X 8'H DOUBLE SWING GATE (INSWING)1 NOTES: 1)MAX OC POST SPACINGS HAVE A TOLERANCE OF + 2.0" 2)ALL UNDERGROUND CONFLICTS TO BE FIELD LOCATED PRIOR TO FENCE INSTALLATION. 3)INSTALLER TO TAKE SPECIAL CARE WHEN INSTALLING FENCE POSTS AROUND UNDERGROUND CONFLICTS. 4)UNLESS OTHERWISE INDICATED. USE MAX OC POST SPACING (SPAN) AT UNDERGROUND CONFLICTS, CENTER SPAN ABOVE CONFLICT TO PROVIDE MAXIMUM CLEARANCE ON EITHER SIDE. 5)ALL FENCE TO BE HOT DIP GALVANIZED. 6)GATE OPENINGS ARE MEASURED AS THE DISTANCE BETWEEN THE INSIDE FACES OF THE GATE POSTS. 7)FENCE RUN DIMENSIONS ROUNDED TO NEAREST INCH. 2 3 4'W X 8'H MAN GATE (HINGE RIGHT, SWING OUT) 12'W X 8'H DOUBLE SWING GATE (INSWING) 3 2 1 EE EEEEEE 57'-6" 155'-11 3/4"154'-8"18'-4"68'-4"129'-9 3/4"45'-7" ON WALL23'-11" ON WALL 104'-8 3/4" 41'-6 1/4" 20'-10 3/4"12'-1"94° 94° 126°144°164° 107° 9 1 ° BASEPLATED POSTS ON EXISTING WALL 80'-9 3/4"15'-11"10'-0"10'-0"USE MAX SPAN CENTERED OVER CONFLICTS10'-0"10'-0"SOUTH 21ST STREET 30 MPH SR-51540 MPHCLEAR VISION AREA SECURIFOR 4D 65% OPEN AREA25'-7 1/2"ON WALL PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED2.00SITE LAYOUT-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR32.00 8"80"96"8"96"42"Ø18" PIER 6"138" LINE POST138" TERMINAL / CORNER POST8'H X 8'W (NOMINAL) SECURIFOR 4D 1-1 X 8.5GA WELDED WIRE MESH 35% SCREENING / 65% OPEN AREA ~121.6 LB / PANEL ~EQUAL~EQUAL~EQUALMESH TO RAIL BRACKET 6" UNION RETENTION STRAP (FRONT AND BACK OF UNION) 3" SQ X 11GA POST TYP PRESS-ON POST CAP SECURE w/ TEK SCREW OR RAM SET Ø1-5/8" OD SS30 RAIL TYP TERMINAL UNION RETENTION STRAP SCALE: NTS TYPICAL ELEVATION1 SCALE: NTS PLAN2 SCALE: NTS SECTION3 8'H SECURIFOR 4D 1-1 GUARDIAN 1000 MED UNION 36" MAX CANTILEVER DENTAL STRIP FIELD BOLTED THROUGH TOP OF MESH 4 DETAIL @ DENTAL STRIP SCALE: NTS BOLT THROUGH WASHERS, MESH & DENTAL STRIP USING Ø5/16"-18 X 1.5" CARRIAGE BOLT w/ BREAKAWAY NUT Ø.5" ID X Ø1.5" OD FENDER WASHERS ON EITHER SIDE OF MESH 4316"1" FROM EXTERIOR FACE OF MESH DENTAL STRIP AFFIXED TO TOP OF MESH 120" POSTS OC TYP 3"3" ~EQUAL 100" UNIONS OC MAX TYP ~EQUAL 3 3.00 4 3.00 EXTERIOR INTERIOR 3" SQ X 11GA POST TYP GUARDIAN 1000 MED UNION 6063-T5 ALUMINUM EXTRUSION PROFILE 0.750 1.75 0.500 0.090 0.250 R0.125 0.342 0.875 0.500"[30MM]3.000" [54mm] Ø0.155" [3.94mm] 8.5GA WIRE TYP 0.155" [3.94mm] 8.5GA WIRE TYP ALTERNATING FRONT & BACK WIRES SECURIFOR 4D 1-1 WELDED WIRE MESH DETAIL ~35% SCREENING ~65% OPEN PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED3.008'H SECURIFOR 4DTYPICAL ELEVATION-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR33.00R2 RAILS, PANELS, UNIONS, & DENTAL STRIP FOLLOW SLOPE CONTOUR TOP OF PIER TO MATCH SLOPE PIER & POST ON LOWEST SIDE OF SLOPE TO MEET MINIMUM PIER DEPTH & EMBEDMENT 120" MAX POSTS O.C. FIELD CUT MESH TO FIT. WIDEST PART CANNOT EXCEED STANDARD PANEL WIDTH FIELD BEND RAILS TO ANGLE OF GRADE 9° / ~16% SLOPE SHOWN FOR REFERENCE. FIELD CUT MESH TO FIT. WIDEST PART CANNOT EXCEED STANDARD PANEL WIDTH USE ADDITIONAL UNION RETENTION STRAPS AT JOINS OF FIELD CUT UNIONS (~20" OC) SCALE: NTS TYPICAL ELEVATION1 Ø1-5/8" OD SS30 RAIL TYP GUARDIAN 1000 MED UNION 6" UNION RETENTION STRAP (FRONT AND BACK OF UNION) MESH TO RAIL BRACKET PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED3.01TYPICAL ELEVATIONFOLLOWING SLOPE-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR33.01 SCALE: NTS TYPICAL ELEVATION1 TRANSITION TO WALL SCALE: NTS PLAN2 SCALE: NTS SECTION3 8'H SECURIFOR 4D 1-1 DENTAL STRIP FIELD BOLTED THROUGH TOP OF MESH DENTAL STRIP AFFIXED TO TOP OF MESH 120" POSTS OC TYP 3"3" ~EQUAL 100" UNIONS OC MAX TYP ~EQUAL NOTE: STRENGTH AND CAPACITY OF EXISTING CONCRETE BY OTHERS.168" MIN180" MAXEXTENDED POST @STEP TO WALL3" SQ X 11GA POST TYP 120" POSTS OC TYP 3 3.02 Ø12" PIER 6"5"112"112"5" 11 2"11 2"8"8" Ø3 4" TYP 3"SQ X 11GA POST 1/2" THK A36 STEEL PLATE EXISTING WALL EXISTING WALL SCALE: NTS BASEPLATE DETAIL4 DENTAL STRIP AFFIXED VERTICALLY TO UNION TERMINAL TRIM APPLIED OVER RAIL ENDS 60"EXTENDED POST TO SHIP AT 240"; CUT ANY EXCESS FROM TOP AFTER INSTALL 96" BASEPLATED POSTEXISTING WALL (~72")INTERIOR GRADE (VARIES) EXTERIOR GRADE ANCHORS DESIGNED & PROVIDED BY OTHERS8"3" SQ X 12GA POST TYP 80"8"EXTERIOR INTERIOR FENCE ON WALL USES SAME CONSTRUCTION AS FENCE WITH EMBEDDED POSTS; SEE SHEET 3.00 FOR TYPICAL DETAILS (~72") WALL4 3.02 PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED3.02TYPICAL ELEVATIONTRANSITION TO WALL-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR33.02 NOTE: BREAKAWAY NUTS ARE SHOWN WITH THE NUT STILL INTACT FOR REFERENCE ONLY. ALL BREAKAWAY NUTS ARE TO BE SPUN OFF PRIOR TO INSTALLL COMPLETION BEFORE BREAK OFF AFTER BREAK OFF 3 GUARDIAN 1000 MESH TO RAIL ATTACHMENT SCALE: NTS INTERIOR EXTERIOR Ø5/16"-18 CARRIAGE BOLT THRU RETENTION STRAP, MESH, & MESH TO RAIL BRACKET 6-3/8" RETENTION STRAP MESH PANEL Ø1-5/8" SS30 RAIL MESH TO RAIL BRACKET; FOR TENSIONING PURPOSES, BRACKET IS NOT DESIGNED TO SEAT FLUSH AGAINST MESH. SOME GAP IS INTENTIONAL AND MAY BE UNEVEN. SOME DEFORMATION OF BRACKET IS ACCEPTABLE. Ø5/16"-18 BREAKAWAY NUT 4 90° OUTSIDE CORNER DETAIL SCALE: NTS INTERIOR EXTERIOR Ø5/16"-18 BREAKAWAY NUTØ5/16"-18 CARRIAGE BOLT THRU TERMINAL RETENTION STRAP & MESH POST TO RAIL BRACKET; FLIP BRACKETS ON ONE SIDE OF POST TO NEST TOGETHER. MESH PANEL G1000 MED UNION TERMINAL UNION RETENTION STRAP; SOME DEFORMATION OF BRACKET IS ACCEPTABLE. 90° OUTSIDE CORNER TRIM (16GA) CAPTURED BETWEEN UNION AND RING OF PTR BRACKET. SECURED WITH TEK SCREW Ø1/4"-20 X 2" TEK SCREWS THROUGH UNION & TRIM INTO RAIL NOTE: CORNER TRIM ONLY USED ON CORNERS 80° TO 110° INTERIOR EXTERIOR 2 GUARDIAN 1000 UNION RETENTION STRAP DETAIL SCALE: NTS Ø5/16"-18 CARRIAGE BOLT THRU RETENTION STRAPS & MESH Ø5/16"-18 BREAKAWAY NUT Ø1-5/8" SS30 RAIL 6-3/8" RETENTION STRAP; SOME DEFORMATION OF STRAP IS ACCEPTABLE. MESH TO RAIL BRACKET (SEE DETAIL 3) BRACKET MATERIAL (REF) 1 POST TO RAIL BRACKET DETAIL SCALE: NTS Ø1-5/8" SS30 RAIL POST TO RAIL BRACKET INTERIOR EXTERIOR ROUND RAIL FITS LOOSELY INSIDE RAIL BRACKET UNTIL ALL BRACKETS ARE INSTALLED Ø5/16"-18 BREAKAWAY NUT Ø5/16"-18 CARRIAGE BOLT THRU TABS OF BRACKET. MESH NOT SHOWN FOR CLARITY POST POST POST TO RAIL BRACKET Ø1-5/8" SS30 RAIL FED THROUGH RING OF PTR BRACKET SIDE VIEW PLAN VIEW G1000 MED UNION MESH TO RAIL BRACKET (SEE DETAIL 3) POST POST TO RAIL BRACKET POST OFFSET FROM CORNER; POST SHOULD BE LOCATED AS CLOSE TO CORNER AS POSSIBLE (~5" TO 6") POST ℄POST ℄UNIONS & MESH CAPTURED BETWEEN 'L' INSIDE CORNER BRACKETS (PAIRED SET) MESH PANEL Ø1-5/8" SS30 RAIL Ø1-1/4" CORNER SPLICE SLEEVED INTO BOTH RAILS EXTERIOR INTERIOR G1000 MED UNIONS Ø5/16"-18 BREAKAWAY NUT Ø5/16"-18 CARRIAGE BOLT THRU RETENTION STRAPS & MESH 5 90° INSIDE CORNER DETAIL SCALE: NTS INTERIOR EXTERIOR MESH PANEL G1000 MED UNION 2.5" X 2" TERMINAL TRIM (16GA) CAPTURED BETWEEN UNION AND RING OF PTR BRACKET. SECURED WITH TEK SCREW Ø1/4"-20 X 2" TEK SCREWS THROUGH UNION & TRIM INTO RAIL PUSH PLUG INSERTED INTO OPEN END OF RAIL PRIOR TO INSTALLING TERMINAL TRIM SCALE: NTS TERMINATION DETAIL6 MESH TO RAIL BRACKET (SEE DETAIL 3) TERMINAL UNION RETENTION STRAP; SOME DEFORMATION OF BRACKET IS ACCEPTABLE. 7 OUTSIDE ANGLED SPLICED CORNER DETAIL SCALE: NTS INTERIOR EXTERIOR Ø5/16"-18 BREAKAWAY NUT Ø5/16"-18 CARRIAGE BOLT THRU RETENTION STRAPS & MESH MESH PANEL Ø1/4"-20 X 2" TEK SCREW THROUGH UNION INTO RAIL G1000 MED UNIONS BUTTED TOGETHER Ø1-1/4" CORNER SPLICE SLEEVED INTO BOTH RAILS POST POST TO RAIL BRACKET UNIONS & MESH CAPTURED BETWEEN BRACKETS; HAND FORMED IN FIELD TO MATCH ANGLE NOTE: 0° TO 45° - USE 8" RETENTION STRAPS 45° TO 80° - USE "L" BRACKET 8 INSIDE ANGLED SPLICED CORNER DETAIL SCALE: NTS INTERIOR EXTERIOR Ø5/16"-18 BREAKAWAY NUT Ø5/16"-18 CARRIAGE BOLT THRU RETENTION STRAPS & MESH POST POST TO RAIL BRACKET MESH PANEL Ø1/4"-20 X 2" TEK SCREW THROUGH UNION INTO RAIL G1000 MED UNIONS BUTTED TOGETHER Ø1-1/4" CORNER SPLICE SLEEVED INTO BOTH RAILS UNIONS & MESH CAPTURED BETWEEN BRACKETS; HAND FORMED IN FIELD TO MATCH ANGLE NOTE: 0° TO 45° - USE 8" RETENTION STRAPS 45° TO 80° - USE "L" BRACKET PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED4.00GUARDIAN 1000TYPICAL DETAILS-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR34.00 FIELD INSTALL FULCRUM LATCH 2" GAP41"41"12"358"51" POST OC 48" 441 8" FRAME 7 8" HINGE GAP3" LATCH GAP SCALE: NTS PLAN2 SWING DIRECTION EXTERIOR INTERIOR FIELD ATTACH 90° DENTAL STRIP TO TOP OF GATE AFTER GATE IS ASSEMBLED & HUNG USING TEK SCREWS @ 10" MAX OC 441 8" FRAME 94" FRAME2" SQ X 11GA HINGE SIDE UPRIGHT 2" SQ X 11GA TOP FRAME 2" SQ X 11GA BTM FRAME 2" X 1" X 14GA MIDRAIL 3/4" X 3/4" X 1/8" ANGLE ALL AROUND MESH 415 8" (∠ 3/4" X 3/4" X 1/8") 3" X 2" X 11GA LATCH SIDE UPRIGHT 94" FRAME441 8" FRAME 47"93" (∠ 3/4" X 3/4" X 1/8")6"6"4" X 3" X 1/4" CLOSURE ANGLES SCALE: NTS TYPICAL ELEVATION1 SCALE: NTS GATE DETAIL4 STANDARD LINE POST 1/8 1/8 TERMINATE RAILS AND FIELD WELD TO GATE POST FIELD WELD HINGES TO GATE POST SCALE: NTS DETAIL @ HINGE POST3 PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED5.004'W X 8'H SEC4D MAN GATETYPICAL-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR35.00 Ø30" PIER 63" MIN60"6"SQ X 1/4" GATE POST47"94" FRAME246" POST OC 21 8" HINGE GAP 1163 8" FRAME 57 9 16"5813 16" 21 8" HINGE GAP 1163 8"FRAME 57 9 16"5813 16" 3" LATCH GAP 2" GAPFIELD INSTALL FULCRUM LATCHFIELD INSTALL DROP RODS 2" X 1" X 14GA MIDRAIL TYP MESH TO RAIL BRACKET 2" X 1/4" FLAT OVER MESH; 2"SQ X 11GA UPRIGHT BEHIND MESH 2"SQ X 11GA TOP MEMBER 2"SQ X 11GA BTM MEMBER 3" X 2" X 11GA LATCH UPRIGHT 3/4" X 3/4" X 1/8" ANGLE ALL AROUND MESH 2"SQ X 11GA HINGE UPRIGHT 1/4" TRUSS CABLE w/ GUSSETS & 1/2" X 6" JAW & EYE TURNBUCKLES w/ A 800LBS WORKING LOAD 1/8 TERMINATE RAILS AND FIELD WELD TO GATE POST 1/8 GATE POST FIELD WELD HINGES TO GATE POST 4 5.10 SCALE: NTS PLAN2 SCALE: NTS SECTION3 SCALE: NTS TYPICAL ELEVATION1 GATE WEIGHT: ~320 LBS PER LEAF SCALE: NTS DETAIL4 SECURIFOR® 4D INFILL 7" BBB HINGE TYP SWING DIRECTION EXTERIOR INTERIOR 1135 8" (3/4" X 3/4" X 1/8" ANGLE)9212" (3/4" X 3/4" X 1/8" ANGLE)36"12"4" X 3" X 1/4" CLOSURE ANGLE FIELD ATTACH 90° DENTAL STRIP TO TOP OF GATE AFTER GATE IS ASSEMBLED & HUNG USING TEK SCREWS @ 12" MAX OC 93"153" GATE POST3 5.10 46"240" OPENING GATES SWING IN AS SHOWN. FOR OPPOSITE SWING, MOUNT GATE LEAFS TOWARD FRONT CORNER OF GATE POST PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED5.1020'W X 8'H DBL SWINGGATE TYPICAL-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR35.10R2 Ø30" PIER 48" MIN42"6"SQ X 1/4" GATE POST47"94" FRAME150" POST OC 21 8" HINGE GAP 21 8" HINGE GAP 2" GAPFIELD INSTALL FULCRUM LATCH FIELD INSTALL DROP RODS 2" X 1" X 14GA MIDRAIL TYP MESH TO RAIL BRACKET 2"SQ X 11GA TOP MEMBER 2"SQ X 11GA BTM MEMBER 3" X 2" X 11GA LATCH UPRIGHT 3/4" X 3/4" X 1/8" ANGLE ALL AROUND MESH 2"SQ X 11GA HINGE UPRIGHT 1/4" TRUSS CABLE w/ GUSSETS & 1/2" X 6" JAW & EYE TURNBUCKLES w/ A 800LBS WORKING LOAD 1/8 TERMINATE RAILS AND FIELD WELD TO GATE POST 1/8 GATE POST FIELD WELD HINGES TO GATE POST 4 5.10 SCALE: NTS PLAN2 SCALE: NTS SECTION3 SCALE: NTS TYPICAL ELEVATION1 GATE WEIGHT: ~210 LBS PER LEAF SCALE: NTS DETAIL4 SECURIFOR® 4D INFILL 7" BBB HINGE TYP SWING DIRECTION EXTERIOR INTERIOR 655 8" (3/4" X 3/4" X 1/8" ANGLE)9212" (3/4" X 3/4" X 1/8" ANGLE)4" X 3" X 1/4" CLOSURE ANGLE FIELD ATTACH 90° DENTAL STRIP TO TOP OF GATE AFTER GATE IS ASSEMBLED & HUNG USING TEK SCREWS @ 12" MAX OC 96"138" GATE POST3 5.10 144" OPENING GATES SWING IN AS SHOWN. FOR OPPOSITE SWING, MOUNT GATE LEAFS TOWARD FRONT CORNER OF GATE POST 36"12"46"683 8" FRAME 683 8"FRAME 3" LATCH GAP PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED5.2012'W X 8'H DBL SWINGGATE TYPICAL-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR35.20R2 138" 132"BTMBTM36" TO GRADE (REF) 36" TO GRADE (REF)3"3" 6"6"11GA 1 4" SCALE: NTS 3" SQ X 11GA LINE POST1 SCALE: NTS 6" SQ X 1/4" DBL SWING GATE POST4 240"BTM60" TO GRADE (REF)3"3" 11GA SCALE: NTS 3" SQ X 11GA EXTENDED POST2 BTM1 2" 96" SCALE: NTS 3" SQ X 11GA BASEPLATED POST35"112"112"5"11 2"11 2"8"Ø3 4" TYP 8" 3"3"11GA ℄ ℄ A 7.00 SCALE: NTS SECTIONA 1/2" THK A36 STEEL PLATE 3/16 PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED7.00TYPICAL POST DETAIL-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR37.00 96"SCALE: NTS SET PTR BRACKETS2 USING JIG TO 718"8718"2"x2"x1/8"x4" ANGLE 1" TS x 16ga GALVANIZED PICKET BOTTOM OF JIG RESTS ON PIER8"88"SET RING OF PTR BRACKET ON ANGLE AND SECURE PTR BRACKET (DO NOT BREAK OFF NUT YET) SCALE: NTS 8'H JIG1SCALE: NTS 8'H UNION3 MEDIUM G100096"A 8.00 PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED8.00UNIONS & JIG-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR38.00 4 TERMINAL RETENTION STRAP SCALE: NTS 6 UNION RETENTION STRAP SCALE: NTS 5 1-5/8" RND MESH TO RAIL BRACKET (W/RET STRAP) SCALE: NTS 1 3" HIGH SECURITY POST TO RAIL HANGER SCALE: NTS 3 2" TENSION BAND SCALE: NTS 834"83 4" 15 8" V A R I E S 10 SPLICE SCALE: NTS 11 TEK SCREW SCALE: NTS 8 CARRIAGE BOLT W/BREAKAWAY NUT SCALE: NTS LENGTH MAY VARY 2 4" SQ TENSION BAND SCALE: NTS 7 "L" INSIDE CORNER RETENTION STRAP SCALE: NTS USE 6 LOBE SECURITY SELF TAPPING SCREWS 9 HEAVY DUTY HS DROP RODS SCALE: NTS PROJECTCUSTOMERHS#QUOTE#DATEDRAFTERREVIEWERSYSTEM FINISHSOUTH GATE STNPUGET SOUND ENERGYFS7339----TJR06-JUN-23HOT DIP GALVANIZED9.00HARDWARE-WARNING: THIS DOCUMENT CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED UNDER THE PROVISIONS OF 49 CFR PART 1520. NO PART OF THIS DOCUMENT MAY BE RELEASED WITHOUT THE WRITTEN PERMISSION OF THE UNDER SECRETARY OF TRANSPORTATION FOR SECURITY, WASHINGTON, DC, 20590. UNAUTHORIZED RELEASE MAY RESULT IN CIVIL PENALTY OR OTHER ACTION, FOR US GOVERNMENT AGENCIES, PUBLIC AVAILABILITY IS GOVERNED BY 5 U.S.C.552. - DO NOT REPRODUCE SECURITY SENSITIVE NOT FOR PUBLIC DISSEMINATION NERC CONFIDENTIAL GUARDIAR RESERVES THE RIGHT TO CHANGE DRAWINGS AT ANY TIME WITHOUT NOTICE. CONTACT YOUR SALES SUPPORT FOR THE MOST UP TO DATE COPY.Main: 972-878-7000 Fax: 214-887-45523309 S. I-45 ENNIS, TX 75119www.Guardiar.comSHEET NO.SOUTH GATE STNR39.00