HomeMy WebLinkAboutAPPROVED_Talbot Hills Ballfields_CCP_240709AZ 181° 43' 19.32"AZ 271° 43' 19.32"
A
Z
3
1
6
°
4
2
'
5
3
.
3
2
"
AZ 90° 01' 25.32"AZ 207° 01' 29.04"L=399.18'R=925.00'Δ=24°43'34"AZ 2° 17' 18.35"TALBOT ROAD SS 23RD STREET
TALBOT HILL
ELEMENTARY SCHOOL
1
2
3
4
TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
253.383.2572 FAX
TALBOT HILL
ELEMENTARY SCHOOL
2230870.10
PERMIT SET
JULY 9, 2024
JAD JAD DCN
05
TALBOT HILL ELEMENTARY SCHOOL
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWN. 23 N.,
RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON.
RENTON
SCHOOL DISTRICT
ANDREW HOLLENBACK
300 SOUTHWEST 7TH STREET
RENTON, WA 98057TED-40-4307C24002560R-4307
GRAPHIC SCALE
0 50 100
1" = 50 FEET
25
N
VICINITY MAP
NOT TO SCALE
N
SITE
TRENCH NOTE
UTILITY NOTE
TOPOGRAPHIC NOTE
FILL SPECIFICATION
IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION
FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE
OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT
SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE
SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL
ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY
SYSTEMS SHALL MEET THE REQUIREMENTS OF THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT,
CHAPTER 49.17 RCW.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE
APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY
VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF
ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND
AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL
DAMAGES THAT INCUR DUE TO THE CONTRACTOR'S FAILURE
TO LOCATE EXACTLY AND PRESERVE ANY AND ALL
UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR
THE LOCATION OF UNDERGROUND UTILITIES.
THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN
ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED
UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS
INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT
ENSURE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE
ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR
OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO
THESE DRAWINGS AS A RESULT.
FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS,
OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS,
TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL,
OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE,
ORDER, OR STANDARD.
AN AUTOCAD DRAWING FILE IS AVAILABLE TO ASSIST WITH
SITE LAYOUT. PLEASE NOTE THAT ELECTRONIC FILES ARE
PROVIDED FOR CONTRACTOR'S CONVENIENCE AND SHALL
NOT REPLACE NOR BE USED TO SUBSTITUTE THE CONTRACT
DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR
PROJECT LAYOUT ACCORDING TO CONTRACT DOCUMENTS
AND COST FOR ELECTRONIC AUTOCAD FILES.
PHONE: (253) 383-2422
FAX: (253) 383-2572
CONTACT: JAMES A. DALEY
AUTOCAD FILE
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30,
TWN. 23 N., RGE. 05 E. W.M. CITY OF RENTON, KING
COUNTY, WASHINGTON
LEGAL DESCRIPTION
2300 TALBOT ROAD S, RENTON, WA 98055
SITE ADDRESS
NAVD 1988 VERTICAL DATUM ON ORTHOMETRICALLY
CORRECTED GPS OBSERVATIONS USING WSRN AND
GEOID 2012A.
VERIFIED CITY OF RENTON 230
(CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE
CUL DE SAC)
ELEV: 230.75
VERTICAL DATUM
NAD 1983
WASHINGTON STATE PLANE NORTH PROJECTION,
BASED ON GPS OBSERVATIONS USING WSRN AND
GEOID 2012A. UNITS OF MEASUREMENT ARE US
SURVEY FEET.
VERIFIED CITY OF RENTON 230
(CASE MONUMENT AT S 23RD ST AND WILLIAMS AVE
CUL DE SAC)
BASIS OF BEARING
3023059073
PARCEL NUMBER
CONTRACTOR SHALL FURNISH AS-BUILT RIM ELEVATIONS,
PIPE INVERT ELEVATIONS, AND STRUCTURE LOCATIONS
(COORDINATES) TO THE NEAREST 0.01 FOOT FOR ALL STORM
DRAINAGE AND UTILITY STRUCTURES, AND AS-BUILT SLOPE
MEASUREMENTS TO THE NEAREST 0.01% FOR ALL CURB
RAMP AND LANDING PANEL JOINTS. CONTRACTOR SHALL
ENGAGE WITH A PROFESSIONAL LAND SURVEYOR LICENSED
IN THE STATE OF WASHINGTON TO FURNISH AS-BUILT
INFORMATION.
AS-BUILT NOTE
SHEET INDEX
Sheet No.Sheet Title
C0 COVER SHEET
C1 PLAY FIELD STORMWATER DRAINAGE PLAN
C2 STORMWATER DRAINAGE NOTES & DETAILS
C3 STORMWATER DRAINAGE DETAILS
C4 STORMWATER DRAINAGE DETAILS
C0
01
COVER SHEET
OWNER/APPLICANT CIVIL ENGINEER
AHBL INC.
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PHONE: 253-383-2422
CONTACT: DAVID NASON
EMAIL: DNASON@AHBL.COM
SURVEYOR ARCHITECT
HUTTEBALL + OREMUS ARCHITECTURE
4010 LAKE WASHINGTON BOULEVARD NE, SUITE 320
KIRKLAND, WA 98033
PHONE: 425-828-8948
CONTACT: KEVIN OREMUS
EMAIL: KOREMUS@HOARCH.COM
RENTON SCHOOL DISTRICT
300 SOUTHWEST 7TH STREET
RENTON, WA 98057
PHONE: 425-204-4437
CONTACT: ANDREW HOLLENBACK
EMAIL: ANDREW.HOLLENBACK@RENTONSCHOOLS.US
AHBL INC.
2215 NORTH 30TH STREET, SUITE 300
TACOMA, WA 98403
PHONE: 253-383-2422
CONTACT: DAVE FOLLANSBEE
EMAIL: DFOLLANSBEE@AHBL.COM
01
7/9/2024
DEVELOPMENT ENGINEERING
SAMorman 08/02/2024
Surface Water Enginering
JFarah 08/15/2024
CATCH BASIN TYPE 2, 60"
CONTROL STRUCTURE
RIM: 197.61
IE: 188.40 8" (E,W)
NYLOPLAST CATCH BASIN
IE: 188.40
NYLOPLAST INLET WITH
ISO PLUS ROW
IE:191.70
SDCO #1
RIM: 203.26
IE: 201.62
SDCO #2
RIM: 198.01
IE: 192.80
STORMWATER DETENTION FACILITY
75 STORMTECH MC-7200 CHAMBERS
14 STORMTECH MC-7200 END CAPS
FACILITY DIMENSIONS: 116.86' x 47.27' x 7
TOP STONE/ELEV: 194.32
TOP CHAMBER/ELEV: 193.32
BOT CHAMBER/ELEV: 188.32
BOT STONE/ELEV: 187.32
BOT/AREA: 5,459 SF
4" INSPECTION PORT
11 LF 8" N-12 @ 10.0%
PERFORATED
COLLECTOR DRAIN
41 LF 12" PVC SDR-35 @ 12.0%
315 LF 8" N-12 @ 2.8%
PERFORATED
COLLECTOR DRAIN
4" PVC SDR-35 PERFORATED
UNDERDRAIN (TYP)
15
'
(
T
Y
P
)
UNDERDRAIN / COLLECTOR
DRAIN CONNECTION (TYP)
4" UNDERDRAIN
PVC CAP (TYP)
5 LF 12" PVC SDR-35 @ 0.0%
CONNECT TO EXISTING
STORMWATER MANHOLE
IE:183.50
146 LF 4" UNDERDRAIN @ 1.0% MIN 186 LF 4" UNDERDRAIN @ 1.0% MIN 219 LF 4" UNDERDRAIN @ 1.0% MIN 215 LF 4" UNDERDRAIN @ 1.0
% MIN 210 LF 4" UNDERDRAIN @ 1.0
% MIN 205 LF 4" UNDERDRAIN @ 1.0% MIN 200 LF 4" UNDERDRAIN @ 1.0% MIN 196 LF 4" UNDERDRAIN @ 1.0
% MIN 191 LF 4" UNDERDRAIN @ 1.0
% MIN 186 LF 4" UNDERDRAIN @ 1.0% MIN 171 LF 4" UNDERDRAIN @ 1.0% MIN 166 LF 4" UNDERDRAIN @ 1.0% MIN 161 LF 4" UNDERDRAIN @ 1.0% MIN 156 LF 4" UNDERDRAIN @ 1.0% MIN 152 LF 4" UNDERDRAIN @ 1.0
% MIN 136 LF 4" UNDERDRAIN @ 1.0
% MIN 133 LF 4" UNDERDRAIN @ 1.0% MIN 129 LF 4" UNDERDRAIN @ 1.0% MIN 125 LF 4" UNDERDRAIN @ 1.0% MIN 121 LF 4" UNDERDRAIN @ 1.0
% MIN 117 LF 4" UNDERDRAIN @ 1.0
% MIN 113 LF 4" UNDERDRAIN @ 1.0% MIN
IP
IP
IP
TYP
TYP
TYP
SFTYP
REPLACE AND REPAIR FENCE
MANIFOLD
ISOLATOR
ROW
6" ADS N-12 PERFORATED
UNDERDRAIN
1
2
3
4
TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
253.383.2572 FAX
TALBOT HILL
ELEMENTARY SCHOOL
2230870.10
PERMIT SET
JULY 9, 2024
JAD JAD DCN
05
TALBOT HILL ELEMENTARY SCHOOL
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWN. 23 N.,
RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON.
RENTON
SCHOOL DISTRICT
ANDREW HOLLENBACK
300 SOUTHWEST 7TH STREET
RENTON, WA 98057TED-40-4307C24002560R-4307
GRAPHIC SCALE
0 20 40
1" = 20 FEET
10
N
C1
02
PLAY FIELD
STORMWATER
DRAINAGE PLAN
LEGEND
INLET PROTECTION
SILT FENCE
CATCH BASIN TYPE 2, 60"
CONTROL STRUCTURE
STORM DRAINAGE CLEANOUT
STORM DRAINAGE PIPE
PERFORATED UNDERDRAIN
PERFORATED UNDERDRAIN CAP
DETENTION TRENCH FACILITY
4
C3
4
C3
1
C3
2
C3
2
C3
5
C3
3
C3
1
C4
6
C2
3
C2
IP
SF 5
C2
4
C2
1
C4
1
C4
TYPICAL FIELD
RESTORATION SECTION
SCALE: 1" = 1'
GRASS SEE,
SEE SPECIFICATIONS
3 14" ROOT ZONE SAND MIX,
SEE SPECIFICATIONS
8" BASE SAND MIX,
SEE SPEFICICATIONS
SUBGRADE
TYPICAL DETENTION TRENCH &
FIELD RESTORATION SECTION
SCALE: 1" = 1'
GRASS SEE,
SEE SPECIFICATIONS
3 14" ROOT ZONE SAND MIX,
SEE SPECIFICATIONS
8" BASE SAND MIX,
SEE SPEFICICATIONS
COMMON
BORROW FILL
TOP OF DETENTION TRENCH
BEDDING STONE, ELEV: 194.32
FINISH
GRADE
FINISH
GRADE
02
6
C2
3
C2
2
C4
2
C4
6
C3
1
C4
6
C3
1
C4
6
C3
2
C4
1
C4
6
C3
7/9/2024
DEVELOPMENT ENGINEERING
SAMorman 08/02/2024
1
2
3
4
TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
253.383.2572 FAX
TALBOT HILL
ELEMENTARY SCHOOL
2230870.10
PERMIT SET
JULY 9, 2024
JAD JAD DCN
05
TALBOT HILL ELEMENTARY SCHOOL
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWN. 23 N.,
RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON.
RENTON
SCHOOL DISTRICT
ANDREW HOLLENBACK
300 SOUTHWEST 7TH STREET
RENTON, WA 98057TED-40-4307C24002560R-4307
C2
03
STORMWATER
DRAINAGE NOTES &
DETAILS
2 NOT TO SCALE
STORMWATER DRAINAGE NOTES 3 NOT TO SCALE
PIPE BEDDING
6 NOT TO SCALE
TRENCH SECTION5NOT TO SCALE
SILT FENCE4NOT TO SCALE
CATCH BASIN INSERT
03
1 NOT TO SCALE
TESC STANDARD NOTES
7/9/2024
DEVELOPMENT ENGINEERING
SAMorman 08/02/2024
1
2
3
4
TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
253.383.2572 FAX
TALBOT HILL
ELEMENTARY SCHOOL
2230870.10
PERMIT SET
JULY 9, 2024
JAD JAD DCN
05
TALBOT HILL ELEMENTARY SCHOOL
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWN. 23 N.,
RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON.
RENTON
SCHOOL DISTRICT
ANDREW HOLLENBACK
300 SOUTHWEST 7TH STREET
RENTON, WA 98057TED-40-4307C24002560R-4307
C3
04
STORMWATER
DRAINAGE DETAILS19 1/4" MIN.12"8"MINPEA GRAVEL UNDER PIPE
PEA GRAVEL BACKFILL
FIRM TRENCH SIDES WITH NO
LOOSE MATERIAL ON BOTTOM
OF TRENCH
GEOTEXTILE FABRIC
4" PVC UNDERDRAIN PIPE
GRASS SEED, SEE
SPECIFICATIONS
2"MIN8"MINSUBGRADE31/4"BASE SAND MIX, SEE
SPECIFICATIONS
ROOT ZONE SAND MIX,
SEE SPECIFICATIONS
TRENCH LIMITS
30% VOID RATIO OF
PEA GRAVEL
8" N-12 PERFORATED
COLLECTOR DRAIN AS
PER PLAN
FINISH GRADE
PER PLAN2" MINGEOTEXTILE
FABRIC
24" MIN VARIES2"5'-0"
90 DEG. REDUCING SNAP TEE OR
45 DEG. SNAP Y AND REDUCING
COUPLING AS REQUIRED (NO
SADDLE TEES).
2" DEPTH MIN. PEA GRAVEL
BENEATH PIPE (TYP)
PERFORATED COLLECTOR DRAIN
PIPE, ELEVATION PER FIELD
DRAINAGE PLAN
ALT. CONNECTION WHERE INVERT
ELEVATIONS ALLOWS. 90 DEG. ELL.
W/ 90 DEG. REDUCING SNAP TEE.
UNDERDRAIN PIPE
PEA GRAVEL BACKFILL
GEOTEXTILE FABRIC
FINISH GRADE
5 NOT TO SCALE
CONTROL STRUCTURE
1 NOT TO SCALE
4" PERFORATED UNDERDRAIN
2 NOT TO SCALE
8" COLLECTOR DRAIN
4 NOT TO SCALE
COLLECTOR DRAIN CLEAN OUT
3 NOT TO SCALE
COLLECTOR DRAIN CONNECTION
046NOT TO SCALE
ADS STORMTECH MC-7200 STORMWATER DRAINAGE DETENTION FACILITY DETAILS StormTech888-892-2694 | WWW.STORMTECH.COM®Chamber System4640 TRUEMAN BLVDHILLIARD, OH 430261-800-733-7473DATE: 05/27/2024DRAWN: JMCPROJECT #:S414199 CHECKED: BSWTHIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATERESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS.DATEDRWCHKDESCRIPTIONTALBOT HILL ELEMENTARYSCHOOLRENTON, WA, USASHEET
OF2 6
*INVERT ABOVE BASE OF CHAMBER
MAX FLOWINVERT*DESCRIPTIONITEM ON
LAYOUTPART TYPE
1.55"12" BOTTOM PARTIAL CUT END CAP, PART#: MC7200IEPP12B / TYP OF ALL 12" BOTTOM
CONNECTIONSAPREFABRICATED END CAP
35.69"12" TOP PARTIAL CUT END CAP, PART#: MC7200IEPP12T / TYP OF ALL 12" TOP CONNECTIONSBPREFABRICATED END CAP
2.26"24" BOTTOM PARTIAL CUT END CAP, PART#: MC7200IEPP24B / TYP OF ALL 24" BOTTOM
CONNECTIONS AND ISOLATOR PLUS ROWSCPREFABRICATED END CAP
INSTALL FLAMP ON 24" ACCESS PIPE / PART#: MCFLAMPDFLAMP
1.55"12" x 12" BOTTOM MANIFOLD, ADS N-12EMANIFOLD
35.69"12" x 12" TOP MANIFOLD, ADS N-12FMANIFOLD
7.5 CFS IN30" DIAMETER (24.00" SUMP MIN)GNYLOPLAST (INLET W/ ISO
PLUS ROW)
6.0 CFS OUT30" DIAMETER (DESIGN BY ENGINEER) PER PLANHCATCH BASIN (5/C3) NYLOPLAST
(OUTLET)
6" ADS N-12 DUAL WALL PERFORATED HDPE UNDERDRAINIUNDERDRAIN
4" SEE DETAILJINSPECTION PORT
ISOLATOR ROW PLUS
(SEE DETAIL)
PLACE MINIMUM 17.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDING
STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL
CHAMBER INLET ROWS
BED LIMITS 01020104.34'
51.61'52.00'
A
B
C
D
E
F
G
H
I
J
NOTES
·MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECHNICAL NOTE 6.32 FOR MANIFOLD SIZING GUIDANCE.
·DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE
TO STANDARD MANIFOLD COMPONENTS IN THE FIELD.
·THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS
RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE
INCREASED OR DECREASED ONCE THIS INFORMATION IS PROVIDED.
·THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.
PROPOSED LAYOUT
75 STORMTECH MC-7200 CHAMBERS
14 STORMTECH MC-7200 END CAPS
12 STONE ABOVE (in)
12 STONE BELOW (in)
40 % STONE VOID
5,461 SYSTEM AREA (ft²)
328 SYSTEM PERIMETER (ft)
20,665 MINIMUM INSTALLED STORAGE (cf)
PROPOSED ELEVATIONS
200.32 MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED)
195.82 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC)
195.32 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC)
195.32 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT)
195.32 MINIMUM ALLOWABLE GRADE (TOP OF RIGID PAVEMENT)
194.32 TOP OF STONE
193.32 TOP OF MC-7200 CHAMBER
191.29 12" TOP MANIFOLD INVERT
188.51 24" ISOLATOR ROW PLUS CONNECTION INVERT
188.45 12" BOTTOM MANIFOLD INVERT
188.32 BOTTOM OF MC-7200 CHAMBER
187.32 UNDERDRAIN INVERT
187.32 BOTTOM OF STONE
37.74'9.51'6.59'35.58'44.67'47.27'116.86
7/9/2024
DEVELOPMENT ENGINEERING
SAMorman 08/02/2024
1
2
3
4
TEL www.ahbl.comWEBTELwww.ahbl.comWEBTELwww.ahbl.comWEB
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422TEL www.ahbl.comWEB
TACOMA SEATTLE SPOKANE TRI-CITIES
Know what's below.
before you dig.Call
R
253.383.2572 FAX
TALBOT HILL
ELEMENTARY SCHOOL
2230870.10
PERMIT SET
JULY 9, 2024
JAD JAD DCN
05
TALBOT HILL ELEMENTARY SCHOOL
A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SEC. 30, TWN. 23 N.,
RGE. 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON.
RENTON
SCHOOL DISTRICT
ANDREW HOLLENBACK
300 SOUTHWEST 7TH STREET
RENTON, WA 98057TED-40-4307C24002560R-4307
C4
05
STORMWATER
DRAINAGE DETAILS
05
2 NOT TO SCALE
NYLOPLAT DRAIN BASIN
NYLOPLAST DRAIN BASIN
NTS
NOTES
1.8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536
GRADE 70-50-05
2.12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05
3.DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS
4.DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212
FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC
5.FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM
6.TO ORDER CALL: 800-821-6710
A PART #GRATE/SOLID COVER OPTIONS
8"
(200 mm)2808AG PEDESTRIAN LIGHT
DUTY
STANDARD LIGHT
DUTY SOLID LIGHT DUTY
10"
(250 mm)2810AG PEDESTRIAN LIGHT
DUTY
STANDARD LIGHT
DUTY SOLID LIGHT DUTY
12"
(300 mm)2812AG PEDESTRIAN
AASHTO H-10
STANDARD AASHTO
H-20
SOLID
AASHTO H-20
15"
(375 mm)2815AG PEDESTRIAN
AASHTO H-10
STANDARD AASHTO
H-20
SOLID
AASHTO H-20
18"
(450 mm)2818AG PEDESTRIAN
AASHTO H-10
STANDARD AASHTO
H-20
SOLID
AASHTO H-20
24"
(600 mm)2824AG PEDESTRIAN
AASHTO H-10
STANDARD AASHTO
H-20
SOLID
AASHTO H-20
30"
(750 mm)2830AG PEDESTRIAN
AASHTO H-20
STANDARD AASHTO
H-20
SOLID
AASHTO H-20
INTEGRATED DUCTILE IRON
FRAME & GRATE/SOLID TO
MATCH BASIN O.D.
VARIOUS TYPES OF INLET AND
OUTLET ADAPTERS AVAILABLE:
4-30" (100-750 mm) FOR
CORRUGATED HDPE
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
BACKFILL MATERIAL BELOW AND TO SIDES
OF STRUCTURE SHALL BE ASTM D2321
CLASS I OR II CRUSHED STONE OR GRAVEL
AND BE PLACED UNIFORMLY IN 12" (305 mm)
LIFTS AND COMPACTED TO MIN OF 90%
TRAFFIC LOADS: CONCRETE DIMENSIONS
ARE FOR GUIDELINE PUPOSES ONLY.
ACTUAL CONCRETE SLAB MUST BE
DESIGNED GIVING CONSIDERATION FOR
LOCAL SOIL CONDITIONS, TRAFFIC LOADING
& OTHER APPLICABLE DESIGN FACTORS
ADAPTER ANGLES VARIABLE 0°- 360°
ACCORDING TO PLANS
18" (457 mm)
MIN WIDTH
A
AASHTO H-20 CONCRETE SLAB
8" (203 mm) MIN THICKNESS
VARIABLE SUMP DEPTH
ACCORDING TO PLANS
[6" (152 mm) MIN ON 8-24" (200-600 mm),
10" (254 mm) MIN ON 30" (750 mm)]
4" (102 mm) MIN ON 8-24" (200-600 mm)
6" (152 mm) MIN ON 30" (750 mm)
12" (610 mm) MIN
(FOR AASHTO H-20)
INVERT ACCORDING TO
PLANS/TAKE OFF
1 NOT TO SCALE
ADS STORMTECH MC-7200 STORMWATER DRAINAGE DETENTION FACILITY NOTES & DETAILS
7/9/2024
DEVELOPMENT ENGINEERING
SAMorman 08/02/2024