Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RS_Geotechnical Report_170926
© 2017 HERE © 2017 Microsoft Corporation SITE Environmental Earth Sciences Terra Associates, Inc. Consultants in Geotechnical Engineering Geology and Figure 1 VICINITY MAP 0 1000 2000 APPROXIMATE SCALE IN FEET REFERENCE: https://www.bing.com/maps ACCESSED 9/22/17 Proj.No. T-7716 Date:SEPT 2017 RENTON, WASHINGTON 605 MONSTER RD SW © 2017 DigitalGlobe ©CNES (2017) Distribution Airbus DS © 2017 Microsoft Corporation B-1 B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 REFERENCE: REFERENCE ONLY AND SHOULD NOT BE USED FOR DESIGN OR CONSTRUCTION PURPOSES. DIMENSIONS ARE APPROXIMATE. IT IS INTENDED FOR NOTE: THIS SITE PLAN IS SCHEMATIC. ALL LOCATIONS AND LEGEND: 0 100 200 APPROXIMATE SCALE IN FEET APPROXIMATE BORING LOCATION SITE PLAN PROVIDED BY https://www.bing.com/maps. Environmental Earth Sciences Terra Associates, Inc. Consultants in Geotechnical Engineering Geology and EXPLORATION LOCATION PLAN Figure 2Proj.No. T-7716 Date:SEPT 2017 RENTON, WASHINGTON 605 MONSTER RD SW NOT TO SCALE 1. NOTES: 2. 4. 3. 5. 7. 6. 8. 9. PLASTIC COUPLINGS. PLASTIC PROTECTIVE SLEEVE SHOULD EXTEND AT LEAST 1" ABOVE TOP OF FILL SURFACE. STEEL MARKER ROD SHOULD EXTEND AT LEAST 6" ABOVE TOP OF PLASTIC PROTECTIVE SLEEVE. ADDITIONAL SECTIONS OF PLASTIC PROTECTIVE SLEEVE CAN BE CONNECTED WITH PRESS-FIT ADDITIONAL SECTIONS OF STEEL ROD CAN BE CONNECTED WITH THREADED COUPLINGS. PLASTIC TUBING. SLEEVE IS NOT ATTACHED TO ROD OR BASE. PROTECTIVE SLEEVE SURROUNDING MARKER ROD SHOULD CONSIST OF 2" DIAMETER MARKER ROD IS ATTACHED TO BASE BY NUT AND WASHER ON EACH SIDE OF BASE. MARKER ROD IS 1/2" DIAMETER STEEL ROD THREADED AT BOTH ENDS. BEDDING MATERIAL, IF REQUIRED, SHOULD CONSIST OF CLEAN COARSE SAND. BASE CONSISTS OF 3/4" THICK, 2'x2' PLYWOOD WITH CENTER DRILLED 5/8" DIAMETER HOLE. SURCHARGE OR FILLOR FILL SURCHARGE PROTECTIVE SLEEVE STEEL ROD HEIGHT VARIES (SEE NOTES) Environmental Earth Sciences Terra Associates, Inc. Consultants in Geotechnical Engineering Geology and SETTLEMENT MARKER DETAIL Figure 3Proj.No. T-7716 Date:SEPT 2017 RENTON, WASHINGTON 605 MONSTER RD SW 12" COMPACTED STRUCTURAL FILL EXCAVATED SLOPE (SEE REPORT TEXT FOR APPROPRIATE INCLINATIONS) SLOPE TO DRAIN 12" MINIMUM 3/4" MINUS WASHED GRAVEL 3" BELOW PIPE 12" OVER PIPE 4" DIAMETER PERFORATED PVC PIPE SEE NOTE 6"(MIN.) NOT TO SCALE NOTE: MIRADRAIN G100N PREFABRICATED DRAINAGE PANELS OR SIMILAR PRODUCT CAN BE SUBSTITUTED FOR THE 12-INCH WIDE GRAVEL DRAIN BEHIND WALL. DRAINAGE PANELS SHOULD EXTEND A MINIMUM OF SIX INCHES INTO 12-INCH THICK DRAINAGE GRAVEL LAYER OVER PERFORATED DRAIN PIPE. Environmental Earth Sciences Terra Associates, Inc. Consultants in Geotechnical Engineering Geology and TYPICAL WALL DRAINAGE DETAIL Figure 4Proj.No. T-7716 Date:SEPT 2017 RENTON, WASHINGTON 605 MONSTER RD SW Environmental Earth Sciences Terra Associates, Inc. Consultants in Geotechnical Engineering Geology and MAJOR DIVISIONS LETTER SYMBOL TYPICAL DESCRIPTION GRAVELS More than 50% of coarse fraction is larger than No. 4 sieve Clean Gravels (less than 5% fines) GW Well-graded gravels, gravel-sand mixtures, little or no fines. GP Poorly-graded gravels, gravel-sand mixtures, little or no fines. Gravels with fines GM Silty gravels, gravel-sand-silt mixtures, non-plastic fines. GC Clayey gravels, gravel-sand-clay mixtures, plastic fines. SANDS More than 50% of coarse fraction is smaller than No. 4 sieve Clean Sands (less than 5% fines) SW Well-graded sands, sands with gravel, little or no fines. SP Poorly-graded sands, sands with gravel, little or no fines. Sands with fines SM Silty sands, sand-silt mixtures, non-plastic fines. SC Clayey sands, sand-clay mixtures, plastic fines. SILTS AND CLAYS Liquid Limit is less than 50% ML Inorganic silts, rock flour, clayey silts with slight plasticity. CL Inorganic clays of low to medium plasticity. (Lean clay) OL Organic silts and organic clays of low plasticity. SILTS AND CLAYS Liquid Limit is greater than 50% MH Inorganic silts, elastic. CH Inorganic clays of high plasticity. (Fat clay) OH Organic clays of high plasticity. HIGHLY ORGANIC SOILS PT Peat.COARSE GRAINED SOILSMore than 50% material largerthan No. 200 sieve sizeFINE GRAINED SOILSMore than 50% material smallerthan No. 200 sieve sizeDEFINITION OF TERMS AND SYMBOLS COHESIONLESSCOHESIVE Standard Penetration Density Resistance in Blows/Foot Very Loose 0-4 Loose 4-10 Medium Dense 10-30 Dense 30-50 Very Dense >50 Standard Penetration Consistancy Resistance in Blows/Foot Very Soft 0-2 Soft 2-4 Medium Stiff 4-8 Stiff 8-16 Very Stiff 16-32 Hard >32 2" OUTSIDE DIAMETER SPILT SPOON SAMPLER 2.4" INSIDE DIAMETER RING SAMPLER OR SHELBY TUBE SAMPLER WATER LEVEL (Date) Tr TORVANE READINGS, tsf Pp PENETROMETER READING, tsf DD DRY DENSITY, pounds per cubic foot LL LIQUID LIMIT, percent PI PLASTIC INDEX N STANDARD PENETRATION, blows per foot UNIFIED SOIL CLASSIFICATION SYSTEM Figure A-1Proj.No. T-7716 Date:SEPT 2017 RENTON, WASHINGTON 605 MONSTER RD SW