VARMA SFR FRONTAGE IMPROVEMENTS
NW 1/4 OF NE 1/4 OF SECTION 14, T. 23 N., R. 05 E., W.M.
CITY OF RENTON, KING COUNTY WASHINGTON
n
ITj0
Ex unurr POLE (TOP)
I �
3
8
8
TAX PARCEL 142305-9116
15514 SE 132ND ST, RENTON 98059
RENTON ZONING R-4
AS -BUILT RECORD NOTES
A GROUND SURVEY WAS PERFORMED BY ENCOMPASS
ENGINEERING AND SURVEYING (EES) IN SUPPORT OF THE
PREPARATION OF THIS RECORDED DRAWING. THE
AS -BUILT INFORMATION AS SHOWN WAS DEVELOPED
BASED ON A REDLINE PLAN PROVIDED BY EES AS
RECEIVED ON 41812024
THIS RECORD DRAWING HAS BEEN PREPARED BY G2
CIVIL. THE INFORMATION PRESENTED HEREON IS
BASED UPON A COMBINATION OF APPROVED DESIGN
PLAN INFORMATION, CONTRACTOR FIELD DRAWINGS
PREPARED DURING THE COURSE OF CONSTRUCTION,
AS -BUILT FIELD SURVEY INFORMATION GATHERED BY
THE PROJECT LICENSED SURVEYOR OVER THE
all
al
REVISION
IMULCH IF NOT
BEING
BEING WORKED
LIMITS OF
CLEARING
& GRADING
r�-
PROPOSED
TREES
Y
1�
ORT
0 5 10 20
I�
SCALE 1" = 20'
ROADSIDE 32' 24"MIN
TYPICAL
FINAL GRADE POWER, W,ANDOMMUNIUnONS
24"MIN — BACKFILL (NO ROCKS OVEN TO -DIAMETER)
36"MIN SEPARATION 3
48„ COVEN
% 12'MIN 12"MIN
SEPARATION SEPARATION 6"OR 12"MIN SAND SHADING AFTER COMPACTION'
0' BAND BETIDING
GAS 'PRIMARY POWER
COMMUNICATIONS CABLES OR CONDUIT
JOINT UTILITY TRENCH
=zD' R"' CITY OF
IMAM.EDM RENTON
RK DATUM
TAT 5116 2 EDM EDM Planning/Building/Public Works Dept.
BY DATE APPR Inn u `"• RDI'""
A. CONDUCT PRE -CONSTRUCTION MEERNG.
B. RAG OR FENCE CLEARING LIMITS,
C. POST SIGN WITH NAME AND PHONE NUMBER OF TESL
SUPERVISOR.
D. INSTALL CATCH BASIN PROTECTION IF REWIRED.
E GRADE AND INSTALL CONSTRUCRON ENTRANCE(S).
F. INSTALL PERIMETER PROTECTION (SILT FENCE BRUSH
BARRIER, ETC.).
G CONSTRUCT SEDIMENT PONDS AND MAPS (IF NEEDED)
NOT ANTICIPATED.
H. GRADE AND STABILIZE CONSTRUCTION ROADS
I. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTER
DIKES PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY MM
CLEARING AND IMAGING FOR PRO.HCT D OPMENT.
J. MAINTAIN EROSION CONTROL MEASURE IN ACCORDANCE
WITH CITY OF RENTON STANDARDS AND MANUFACTURER'S
RECOMMENOAnONS.
K. RELOCATE ERMON CONTROL MEASURES OR INSTALL NEW
MEASURES SO MAT AS SITE CONDITIONS CHANGE ME
EROSION AND SEDIMENT CONTROL IS ALWAYS IN
ACCORDANCE WITH THE CITY TESC MINIMUM
REQUIREMENTS.
I. COVER ALL AREAS WITHIN ME SPECIFIED TIME FRAME
ISM STRAW, Now FIBER MULCH, COMPOST, PLASTIC
SHEETING CRUSHED ROCK OR EQUIVALENT.
M. STABILIZE ALL AREAS MAT REACT FINAL GRADE MMIN
Z DAYS.
N. SEED OR SOD ANY AREAS TO REMAIN UNREFINED FOR
MORE MAN 30 DAYS
0. UPON COMPLETION OF ME PROJECR ALL DISTURBED
AREAS MUST BE STABILIZED AND BEST MANAGEMENT
PRACTICES REMOVED IF APPROPRIATE.
ALL EXPOSED SOIL TO BE COVERED MM MULCH, STRAW,
AND/OR PLASTIC SHEETING PER FIG. C.3.4.A AND/02 TABLE
C.3.2.A KCSNOM. UNDER NO ORCUMSTANCES SHALL SOIL
STOCKPILES SE LEFT UNCOVERED.
SOIL AMENDMENT NOTE
TO THE MAXIMUM EXTENT POSSIBLE TOPSOIL/r UTURE
LANDSCAPE AREAS OUTSIDE IMPERVIOUS AREAS SHALL BE
LEFT UNDISTURBED AND FROTECTED FROM COMPACTION
DURING CONSTRUCTION. MIS AFPLIES SOIL AMENDMENT
OPTION I PER KING COUNTY POST CONSTRUCTION STANDARD
REQUIREMENTS SEE APPROVED COMPOST AND TOPSOIL
CALCUL4nO4 NORKSHEEi.
A LEAVE NATIVE S&L UNDISTURBED (965,263 SF)
B. STOCKPILE NATIVE SOILS AND REAPPLY AFTER GRADING
AND CONSTRUTION (28.314 SF)
SILT FENCE MAINTENANCE PER 2016 KCSWDM
1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY.
2. IF CONCENTRATED FLONS ARE EWDENT UPHILL OF ME
FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO
A SEDIMENT TRAP DR POND.
J. IT IS IMPORTANT TO CHECK ME UPHILL SIDE OF ME
FENCE FOR SIGNS OF ME FENCE CLOGGING AND ACTING
AS A BARRIER TO FLOW AND MEN CAUSING
CIIANNRIZAnON OF FLOWS PARALLEL TOT HE FENCE IF
MIS OCCURS, REPLACE ME FENCE GM REMOVE ME
TRAPPED SEDIMENT.
4. SEDIMENT MUST BE REMOVED MEN THE SEDIMENT IS 6
INCHES HIGH.
5. IF ME FILTER FABRIC (GEOTEXRLE) HAS DETERIORATED
DUE TO ULMAWG ET 86EAKDOWIN, IT SHALL BE
REPLACEO.
EXISTING UTILITY NOTE
ALL UTILITIES MUST BE UNDERGROUND TO ME PROPERTY.
AND ME ONNER OR CONTRACTOR WILL NEED TO CONTACT
ALL UTILITY COMPANIES PRIOR TO NEEDING ANY OF THESE
SERNCES. EACH COMPANY WILL NEED TO DESIGN THEIR
CONNECTION AND APPLY TO THE CITY FOR A PERMIT
PUGET SOUND ENERGY
CARLI BUNIMMAN 425-429-0227
CARLI.BUNKELMANGIRSECOM
LUMEN/CENTURY ❑NK
AMY ALLSTON 25J-797-4545
AMY.ALUSTCN6LUMEN.COW
LUMEN/CENTURY LINK
EDD SAGGVS 720-931
ESACCUS®1RUENETCOMMUNICAnO/SCOM
ORLY
JAY SCHWAB 425-263-4019
JAY.SCHWABADPLY.EOM
R-425302
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
VARMA SFR FRONTAGE IMPROVEMENTS
TESC/TREE RETENTION PLAN
AS -BUILT DRAWING