HomeMy WebLinkAboutMFP24004242.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP24004242
IVR Number: 24004242
Permit Information
Permit Name: Puget Sound Energy - Electric
Address/Location:08/21/2024Application Date:6196600062Parcel Number: 17620 116TH AVE SE
Permit Type:09/04/2024Issue Date:Franchise
Permit Work Class:09/04/2025Expiration Date:Minor Utility
Job Number: 101160929Franchise Type:Electric
Description: Puget Sound Energy Electric CREW TO REPLACE 7 B/O POLES. P01 (316485 166591) P02 (316238 166586) P03
(316209 166506) P04 (315988 166231) P05 (316056 166684) P06 (316071 166684) AND P07 (316131 166686).
RESTORATION PER CITY OF RENTON STANDARDS.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031ApplicantX
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
PLEASE SEE ATTACHED
POTELCO, INC
6905 S 228TH ST KENT, WA 98032
101160929
17620 116TH AVE SE
ECHO GOOD 253-325-1522
MFP24004242
Monday Friday 8:00am 3:00pm
Scott Warlick CED 9/4/2024
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
CORRIE RYDBERG
11111111116TH AVE SE SE 186TH ST114TH AVE SE
11111111111113131010SE 186TH ST1111STO
PSTOP
W20-1ROAD
WORK
AHEAD W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7A
1010SE 186TH PLFROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGP03RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSURENSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com1 OF 517620 116TH AVE SE, RENTON, WA 980580 11921199 07/29/2024Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316MFP24004242
P04SE 192ND ST108TH AVE SE11111010107TH AVE SE
1212111212121211121217 11 14
BUS
STOP
BUSSTOP
VAR.1112
SE 192ND STSE 192ND ST106TH AVE SE106TH AVE SE1212 10101111
STOP
STOP
STOP
108TH AVE SE W20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROAD
AHEAD
X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com2 OF 517620 116TH AVE SE, RENTON, WA 980580 11921199 07/29/2024Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040
P05
P06
SE 189TH PL
SE 191ST ST 10101313
13131515120TH AVE SE120TH AVE SE1313
1111
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
STOP
STOP
W20-1ROAD
WORK
AHEAD W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ASTOPW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AN
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Project Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
3 OF 517620 116TH AVE SE, RENTON, WA 98058
0
11921199
07/29/2024
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRONARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound Energy
Traffic Control Supervisor:
Jason Bisenius
Card No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316
MFP24004242
P05
P06
SE 189TH PL
SE 191ST ST 10101313
13131515120TH AVE SE120TH AVE SE1313
1111
RESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
STOP
W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥
STOPW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROAD
WORK
AHEAD W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7ASTOP
W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AProject Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
4 OF 517620 116TH AVE SE, RENTON, WA 98058
0
11921199
07/29/2024
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRONARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound Energy
Traffic Control Supervisor:
Jason Bisenius
Card No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP24004242
SE 188TH ST120TH AVE SEP07
101010101111
1111
120TH AVE SESE 188TH ST
STOP
STOP
STOP
STOPW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4
ONE LANEROADAHEADX'≥X'≥X'≥
W20-7A
W20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEAD
W20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AProject Address:
Page
PSE PUGETSOUNDENERGY
Designer:
Job #
REV
Jason Bisenius
425-424-7316
jason.bisenius@pse.com
5 OF 517620 116TH AVE SE, RENTON, WA 98058
0
11921199
07/29/2024
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRONARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
Puget Sound Energy
Traffic Control Supervisor:
Jason Bisenius
Card No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316
N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
MFP24004242
CØEHJ088
17721
(PVT DRIVEWAY)336 ACSRABCN
25kVA 120/240V
Owner / Developer Contact Info
officeATTN:
PSE
-
-
KELLY ULICNY 425-429-0949
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
PHONE
CABLE TV
11921199 101160929
N/A 593251561
N/A 594155088
N/A 583073105
N/A N/A
N/A 108146906
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
OH Misc Expense
UG Misc Expense
OH Xfmr Expense
UG Xfmr Expense
Removal
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
E. GOOD 253-325-1522 7/5/24
A. VANDERS 425-547-6789 7/5/24
...
H. MORENO 703-623-8662 7/5/24
N/A RENTON
PAN-15 REPL 7 POLES
DISTRIBUTION POLE REPLACEMENT
17620 116TH AVE SE, RENTON, WA 98058
ASPLUNDH CONSTRUCTION
N/A N/A
N/A 101160929
AS NOTED 1 OF 3
KING N/A N/A QCSOKE
SEE LIST N/A N/A
SEE LIST SEE LIST SEE LIST PAN-15 & NOP-26
COMCAST
.
.
CENTURYLINK
.
.
.
.
.
.
.
.
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:ECHO GOOD
253-325-1522
ECHO.GOOD@PSE.COM
...
...
...101160929PAN-15 REPL 7 POLES
DISTRIBUTION POLE REPLACEMENT
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION
STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)
EROSION & SEDIMENT CONTROL REQUIREMENTS
NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES
(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING
0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL
EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE
& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.
OVERHEAD CIRCUIT MAP
SCALE: 6" = 1 MILE
POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID # HEIGHT CLASS YEAR TOPPED RMVD
P01 316485-166591 30 2 1968
P02 316238-166586 40 4 1960
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P01 316485-166591 35 3
P02 316238-166586 45 3
LEGEND
CONDUIT RISER
OVERHEAD TRANSFORMER
JUNCTION VAULT/JUNCTION BOX
NEW CONDUCTOR AND OR TRENCH LINE
DISCONNECT - FUSED
PULL VAULT OR SPLICE VAULT
EXISTING POLE
DOWN GUY
DISCONNECT - UNFUSED
NEW POLE
PADMOUNT TRANSFORMER
SECONDARY HANDHOLE
EXISTING CONDUCTOR TO BE REMOVED
OR ABANDONED
STREET LIGHT
TOTAL UNDERGROUND TRANSFORMER
ENERGY CUSTOMER DEMAND POINT
OR
OR
OR
OVERHEAD JUMPER CONNECTION
Vicinity Map
General
- Return removed materials to the local storeroom or PSE storeroom.
OVERHEAD CONSTRUCTION
Poles & Structures
- All new poles set shall be the class indicated on the sketch, or better. Do not set a lower class pole than
specified.
- Install ground plate assembly on all new poles. Install Switch Ground Assembly per standard specification
6014.1000 at new gang operated switch locations.
- Install grid numbers on all new and existing poles as shown on sketch.
- Straighten existing poles as indicated or as necessary.
- Treat all field-drilled poles with copper napthenate wood preservative.
- Remove old poles after communication companies have transferred off and return to PSE storeroom. Fill
and crown pole holes and restore area similar to adjacent landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors and guys to new poles
set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all transformers. Install at all sites
being worked within the scope of the project where they are currently missing.
- For 12kV construction, always install avian protection with 4/0 Cu covered jumpers and #4 SD
aluminum-covered tie-wire (MID 8454500), For 34 kV construction, use bare wire primary jumpers with
preformed helical grip ties.
- Apply avian protection devices when required per Standard 6015.2000.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise shown on the drawing.
- All neutral connections to be made with solid compression connectors. Connect all pole grounds to
common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and underground taps with fused
protection above 40T.
- Install Wildlife Protectors on all transformers.
UNDERGROUND CONSTRUCTION
Excavation
-Trenching outside of the Right-of-way shall be of sufficient depth to provide a minimum of 36” of cover for
primary conductors and 24” of cover for secondary conductors.
-Road crossings and all trenches within the Right-of-way shall be of sufficient depth to provide a minimum
of 36” of cover for all conductors or as required by the permitting Agency.
-All conductors/conduits shall have a minimum of 3” of bed and 3” of clean sand cover.
-No rocks larger than 6” shall be included in backfill.
-Backfill in road crossings and within the Right-of-way shall be compacted to 95% density or as required
by the permitting Agency.
-Restore all excavated areas to original condition.
UTILITY POLE EROSION CONTROL DETAIL
TOP VIEW
DRY DRAINAGE DITCH or DRY VEGETATED SITE
SLOPE
Place gravel bags for
Sediment Trap
Place straw mulch
on disturbed areaExcavated or
Augered Hole
Pole
SLOPE
Not to scale Drainage ditches or Dry vegetated sites
N.T.S.
SITE PLAN 1
1" = 50'
P01: 316485-166591
BRUSH REMOVAL REQ'D
TREE TRIMMING REQ'D
GRID # MISSING IN FIELD
-EX 30' CL 2, 1968 POLE TO BE REPLACED
-INST 35' CL 3 (PS353) 6010.1100 2-81
-TRANSFER OH TPX SEC (SW)
-TRANSFER (2) OH TPX SVC'S
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
SITE 1
108TH AVE SE
SE 192ND ST
SITE PLAN 2
1" = 50'
P02: 316238-166586
TREE TRIMMING REQ'D
GRID # MISSING IN FIELD
-EX 40' CL 4, 1960 POLE TO BE REPLACED
-INST 45' CL 3 (PD453) 6010.1000 2-81
-DEEP SET +2' DUE TO SLOPE
-INST 1Ø DE #4ACSR (DE2115) 6031.1040
-ROLL NEUT TO COMMON POSITION
-TRANSFER 1Ø #4ACSR PRI & NEUT (N)
-RM EX 10kVA XFMR 120/240V & C/O
-INST 25kVA 120/240V XFMR & L/B C/O (TRFNXF) 6025.1000
-TRANSFER (2) OH TPX SVC'S
-RM EX DG (S)
-INST 3/8" PRI & NEUT DG'S (GYD3SA)(GYD3SAN) 6013.0100 TO EX ANC
-INST AUX EYE (8845300)
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P02
316238-166586
10kVA
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P02
316238-166586
25kVA
6211250
SITE 2
SITE 3
SITE 4
SITE 5
SITE 6
SE PETROVISTKY RD
SE 186TH ST120TH AVE SE
118TH AVE SE
Standoff Bracket
15" Min Length
Conduit Clamp
Conduit Field Face
Quadrant
Climbing
SpaceRoad Face
Quadrant
Climbing
Space
5" Min
CL LCDirection of Vehicular Traffic
CONDUIT RISER PLACEMENT DETAIL
TOP VIEW
NOT TO SCALE
1/4 SECTIONS
NW33-T23N-R05E
SW33-T23N-R05E
SE32-T23N-R05E
NW05-T23N-R05E
SE33-T23N-R05E
OH CKT MAPS
2305E136
2205E036
UG CKT MAPS
2305E130
2305E131
2305E128
2205E018
2305E132
U-MAPS
2305E130
2305E131
2305E128
2205E018
2305E132
N/A 108155228UG SVC Removal
CREW NOTE (P01):
ILLEGALLY ATTACHED CUSTOMER LIGHT
714-713-3033 7/23/24
MFP24004242
RESTORATION PER CITY OF RENTON STANDARDS
11257
106TH AVE SE107TH AVE SE10614 10710
10617
NOP
26
PAN
15
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
E. GOOD 253-325-1522 7/5/24
A. VANDERS 425-547-6789 7/5/24
...
H. MORENO 703-623-8662 7/5/24
N/A RENTON
PAN-15 REPL 7 POLES
DISTRIBUTION POLE REPLACEMENT
17620 116TH AVE SE, RENTON, WA 98058
ASPLUNDH CONSTRUCTION
N/A N/A
N/A 101160929
AS NOTED 2 OF 3
KING N/A N/A QCSOKE
SEE LIST N/A N/A
SEE LIST SEE LIST SEE LIST PAN-15 & NOP-26
COMCAST
.
.
CENTURYLINK
.
.
.
.
.
.
.
.
...
...
...
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)101160929 POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID # HEIGHT CLASS YEAR TOPPED RMVD
P03 316209-166506 45 1 1959
P04 315988-166231 45 3 1961
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P03 316209-166506 45 2
P04 315988-166231 45 H2
SITE PLAN 3
1" = 50'
P03: 316209-166506 (Avg. Span = 181', Angle = 0°)
-EX 45' CL 1, 1959 POLE TO BE REPLACED
-INST 45' CL 2 (PD452) 6010.1000 2-81
-INST 1Ø PTP #4ACSR (TAN112) 6031.1010
-TRANSFER 1Ø #4ACSR PRI & NEUT (W/E)
-TRANSFER 37.5kVA 120/240V XFMR
-TRANSFER OH TPX SEC
-TRANSFER (3) TPX SVC'S
-RM EX RISER
-INST 3" RISER (RIS3CSS) 6042.1000 2-24XX
-TRANSFER 1/0 UG TPX SVC (SE); EXTEND AS REQ'D
-ACTUAL 1/0 UG TPX SVC ADDED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-TRANSFER STREET LIGHT (SLAK4720)2-302
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
SITE PLAN 4
1" = 50'
P04: 315988-166231 (Avg. Span = 184', Angle = 4°)
TREE TRIMMING REQ'D
GRID # MISSING IN FIELD
POLE CLASS & EMBEDMENT METHOD FOR UNGUYED POLE CONFIRMED WITH O-CALC PRO
-EX 45' CL 3, 1961 POLE TO BE REPLACED
-INST 45' CL H2 (PD45H2) 6010.1000 2-81
-INST 10'X36" STEEL CASING (9997493)2-800
-INST GROUND STEEL CASING (GRDCASE) 6014.1000
-INST 3Ø TAN PTP 336 ACSR (TAN313) 6033.1012
-ROLL NEUT TO COMMON POSITION
-TRANSFER 3Ø 336 ACSR PRI & 4/0ACSR NEUT (W/E)
-RM EX GANG-OP SWITCH
-INST 3Ø GANG-OP SWITCH (DLSG15) 6022.2000 (SW#X593)2-24N x 2
-OPERATE AS NORMAL OPEN
-RM EX RISER
-INST 3" RISER (RIS3CSS) 6042.1000 2-24XX
-TRANSFER 350 UG TPX SEC (S); EXTEND AS REQ'D
-ACTUAL 350 UG TPX SEC ADDED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-TRANSFER OH TPX SEC
-TRANSFER OH TPX BRIDLE SVC
-RM EX DG (S)
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
New pole at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER TRANSFER
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
316209-166506
37.5kVA
714-713-3033 7/23/24
MFP24004242
CØEGX823
CØAGA334
CØAEH731
SE 191ST ST
SE 189TH PL
25kVA 120/240V
SE 188TH ST 120TH AVE SE65T
X90438
C
CNCN
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
E. GOOD 253-325-1522 7/5/24
A. VANDERS 425-547-6789 7/5/24
...
H. MORENO 703-623-8662 7/5/24
N/A RENTON
PAN-15 REPL 7 POLES
DISTRIBUTION POLE REPLACEMENT
17620 116TH AVE SE, RENTON, WA 98058
ASPLUNDH CONSTRUCTION
N/A N/A
N/A 101160929
AS NOTED 3 OF 3
KING N/A N/A QCSOKE
SEE LIST N/A N/A
SEE LIST SEE LIST SEE LIST PAN-15 & NOP-26
COMCAST
.
.
CENTURYLINK
.
.
.
.
.
.
.
.
...
...
...
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)101160929 POLE RETIREMENT TABLE TEMP TRANSFERS ST. LIGHT TRANSFERS
SITE
#
POLE DATA POLE
TEL TV FIBER TRAN RMVD ID NUMBER
GRID # HEIGHT CLASS YEAR TOPPED RMVD
P05 316056-166684 40 UNK 1976
P06 316071-166684 40 H1 1975
P07 316131-166686 45 2 1973
POLE TABLE (NEW)
Site
#
Pole Data
Grid #Height Class Year Remarks / Location Ref.
P05 316056-166684 45 3
P06 316071-166684 45 3
P07 316131-166686 45 2
P05: 316056-166684 (Avg. Span = 147', Angle = 0°)
BRUSH REMOVAL REQ'D
-EX 40' CL UNK, 1976 POLE TO BE REPLACED
-INST 45' CL 3 (PD453) 6010.1000 2-81
-INST 1Ø PTP #6CU (TAN115) 6031.1010
-TRANSFER 1Ø #6CU PRI & NEUT (N/S)
-RM EX DBL BUSHING 15kVA 120/240V XFMR & C/O
-INST 25kVA 120/240V XFMR & L/B C/O (TRFNXF) 6025.1000
-TRANSFER OH TPX SVC
-RM EX RISER
-INST 3" RISER (RIS3CSS) 6042.1000 2-24XX
-TRANSFER 350 UG TPX SVC (E); EXTEND AS REQ'D
-ACTUAL 350 UG TPX SVC ADDED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P05
316056-166684
15kVA
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P05
316056-166684
25kVA
6211250
P06: 316071-166684 (Avg. Span = 147', Angle = 0°)
TREE TRIMMING REQ'D
-EX 40' CL H1, 1975 POLE TO BE REPLACED
-INST 45' CL 3 (PD453) 6010.1000 2-81
-INST 1Ø PTP #6CU (TAN115) 6031.1010
-TRANSFER 1Ø #6CU PRI & NEUT (N/S)
-RM EX DBL BUSHING 25kVA 120/240V XFMR & L/B C/O
-INST 25kVA 120/240V XFMR & L/B C/O (TRFNXF) 6025.1000
-TRANSFER (3) OH TPX SVC'S
-RM EX 1Ø TERM & C/O
-INST 1Ø TERM & L/I C/O (TSU1L1) 6043.1000 (SW#X75557)2-57
-FUSE @ 65T (3412600)
-RM EX RISER
-INST 2" RISER (RIS2CSS) 6042.1000 2-45XX
-TRANSFER 1Ø 1/0 AL UG PRI (W); EXTEND AS REQ'D 2-54 x ____'
-ACTUAL 1Ø 1/0 AL UG PRI ADDED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-RM EX IDLE RISER 2-24XR
-RM IDLE 4/0 TPX SEC; ±35'
-CUT AT BASE OF POLE
-ACTUAL 4/0 UG TPX REMOVED L=_________ BATCH YEAR_________
-ACTUAL TRENCH L=_________
-RETIRE ON WO# (108155228)
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
Removed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P06
316071-166684
25kVA
Installed at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER INSTALLATION
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
Material ID#:
P06
316071-166684
25kVA
6211250
SITE PLAN 5
1" = 50'
MAPS AND RECORDS NOTE (P06):
GRID#316071-166684 IS FEEDING (2) OH SVC TO
(2) SEPARATE HOMES 19003 & 19001 120TH AVE
SE RENTON, WA 98058 THAT ARE SHOWN AS UG
SVC FEEDING FROM GRID#316067-166647
AMATCH LINE SEE BOTTOM RIGHTA
SITE PLAN 6
1" = 50'
P07: 316131-166686 (Avg. Span = 154', Angle = 0°)
BRUSH REMOVAL REQ'D
TREE TRIMMING REQ'D
GRID # MISSING IN FIELD
-EX 45' CL 2, 1973 POLE TO BE REPLACED
-INST 45' CL 2 (PD452) 6010.1000 2-81
-DEEP SET +2' DUE TO SLOPE
-INST 1Ø DBL DE #4ACSR (DDE2115) 6031.1043
-TRANSFER 1Ø #4ACSR PRI & NEUT (W/E)
-RM EX 1Ø #4ACSR PRI & NEUT (W/E)
-RM EX 1Ø SW C/O (SOUTH LATERAL)
-INST 1Ø L/I SW C/O (DLS115F) 6022.1000 (EAST LATERAL)(SW#X90438)2-24C
-FUSE @65T (3412600)
-INST 1Ø DBL DE #4ACSR (DDE2115) 6031.1043
-TRANSFER 1Ø #4ACSR PRI & NEUT (N/S)
-TRANSFER OH TPX SVC
-TRANSFER OH TPX SEC
-TOP POLE ABOVE COMM
-REMOVE POLE STUB AFTER COMM HAS TRANSFERRED 2-129
AMATCH LINE SEE TOP LEFT
A
MAPS AND RECORDS NOTE (P07):
THE NORMAL OPEN IS LOCATED AT
316143-166686 AND NOT P07
714-713-3033 7/23/24
MFP24004242