Loading...
HomeMy WebLinkAboutP_CIVIL_SET_240826_v7EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 EX. CB #1 EX.CB #6 EX.CB #7 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID TYPE I GRATE TYPE I GRATE TYPE I GRATE RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 EL 306.95 EL 345.08 EL 354.82 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 12" (N) LCPE IE=302.54 12" (NW) LCPE IE=341.60 12" (E) LCPE IE=341.60 12" (W) LCPE IE=349.02 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 10.824L 5+45.00 14.654L 1+18.16 0.970L EXIST STORM DRAINAGE STRUCTURE TABLE ID SDCB-T1 SDMH-T2.1 SDMH-T2.2 DESCRIPTION CB-TYPE 1 SDMH TYPE 2 SDMH TYPE 2 RIM ELEV EL 307.41 EL 307.91 EL 305.30 PIPE INVERT 12" (SW) EX CMP IE=303.06 12" (NE) RCP IE=303.24 12" (NW) EX CMP IE=302.95 12" (NE) EX CMP IE=302.95 12" (SW) RCP IE=303.63 STATION OFFSET 10+24.68 32.114L 10+46.92 33.577L 9+89.49 28.654L DRAIN 1ST FF= 316.73 2ND FF= 326.08 1ST FF= 317.77 2ND FF= 328.08 1ST FF= 318.35 2ND FF= 328.08 1ST FF= 318.91 2ND FF= 328.08 1ST FF= 320.0 2ND FF= 330.08 1ST FF= 322.61 2ND FF= 331.85 1ST FF= 324.61 2ND FF= 333.77 1ST FF= 331.59 2ND FF= 341.57 1ST FF= 330.35 2ND FF= 340.19 1ST FF= 325.70 2ND FF= 335.27 1ST FF= 325.95 2ND FF= 335.27 1ST FF= 327.35 2ND FF= 336.77 1ST FF= 323.80 2ND FF= 333.95 1ST FF= 324.02 2ND FF= 333.95 1ST FF= 325.81 2ND FF= 337.00 1ST FF= 333.31 2ND FF= 343.03 1ST FF= 333.44 2ND FF= 343.03 1ST FF= 334.94 2ND FF= 344.56 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 333.47 2ND FF= 343.08 1ST FF= 348.19 2ND FF= 357.98 1ST FF= 349.75 2ND FF= 359.52 1ST FF= 351.13 2ND FF= 361.03 1ST FF= 352.61 2ND FF= 362.52 1ST FF= 354.23 2ND FF= 364.01 1ST FF= 348.25 2ND FF= 357.99 1ST FF= 349.53 2ND FF= 359.48 1ST FF= 350.87 2ND FF= 360.98 1ST FF= 352.46 2ND FF= 362.52 1ST FF= 353.96 2ND FF= 364.01 1ST FF= 314.90 2ND FF= 324.73 1ST FF= 315.92 2ND FF= 325.92 1ST FF= 316.10 2ND FF= 325.92 1ST FF= 316.60 2ND FF= 325.92 1ST FF= 317.57 2ND FF= 327.57 BUILDING #2 BUILDING #3 BUILDING #4 BUILDING #5 BUILDING #6BUILDING #7 BUILDING #8 BUILDING #1 SE GRANT CIRCLE SE GRANT CIRCLE GRANT AVE S PRIVATE ALLEY 16' 16' 12' 4' 4' 16' 20' 20' PRIVATE ALLEY ACCESS & PUBLIC UTILITY EASEMENT 20' PRIVATE ALLEY ACCESS & PUBLIC UTILITY EASEMENT 8' 18' 5' 20' 1.5' ROW DEDICATION 10' STORM DRAINAGE EASEMENT 15' UTILITY EASEMENT 3'LANDSCAPE SETBACK SPLIT RAIL FENCE ON TREE PRESERVATION AREA RAIL ON THE RET. WALL TOP EDGE LINEAR DRAIN TO THE SEWER 10' WOOD FENCE ALONG SOUTH PROPERTY LINE WOOD FENCE ALONG NORTH PROPERTY LINE SITE CLIENT/ DEVELOPER: SATWANT SINGH 15 S. GRADY WAY, SUITE 527 RENTON, WA 98057 pmvrsingh@gmail.com CIVIL ENGINEER: DEAN FURR, P.E. FURR ENGINEERING SERVICES PLLC 4715 142ND PL SW UNIT#B EDMONDS, WA 98026 (206) 890-8291 furrengineering@gmail.com SURVEYOR: TIM GRIFFIN TYEE SURVEYORS 10007 GREENWOOD AVE. N SEATTLE, WA 98133 PHONE: (206) 525-3660 SITE INFORMATION: ADDRESS:504-1582 SE GRANT CIRCLE PARCEL NUMBER:202305-9052 ZONING:RM-F PARCEL AREA:92,051 SF (2.11AC) DISTURBED AREA:89,451 SF (2.05 AC) EXISTING IMPERVIOUS AREA:3,900 SF (0.09 AC) GROSS NEW IMPERVIOUS AREA:58,866 SF (1.35 AC) NET NEW IMPERVIOUS AREA:54,966 SF (1.26 AC) BUILDING AREAS: BUILDING 1 3,284 SF BUILDING 2 2,723 SF BUILDING 3 2,723 SF BUILDING 4 3,284 SF BUILDING 5 3,284 SF BUILDING 6 2,723 SF BUILDING 7 2,723 SF BUILDING 8 3,284 SF TOTAL 24,028 SF BUILDING COVERAGE:26% UTILITY PURVEYORS: WATER CITY OF RENTON SEWER CITY OF RENTON STORMWATER CITY OF RENTON ELECTRIC PUGET SOUND ENERGY GAS PUGET SOUND ENERGY GARBGE REPUBLIC SERVICES COMM CENTURYLINK ADDITIONAL NOTES: 1.6" VERTICAL CURB SHALL BE INSTALLED BETWEEN UNIT LOT DRIVEWAY AND ABUTTING LANDSCAPED AREAS. 2.ALL TRACTS (UTILITY, DRAINAGE, SHARED AREAS, OPEN SPACES) SHALL BE PLACED WITHIN SEPARATE TRACTS THAT WOULD BE OWNED AND MAINTAINED BY THE HOMEOWNER'S ASSOCIATION. 3.ALL PRIVATE OPEN SPACE AREAS ATTRIBUTED TO EACH INDIVIDUAL DWELLING UNIT SHALL BE LOCATED ON THE SAME UNIT LOT AS THE DWELLING UNIT. LEGAL DESCRIPTION: AN UNDIVIDED ON-HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY: PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 20, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING ON THE EAST LINE OF SAID SUBDIVISION AT A POINT WHICH IS SOUTH 00°08'49'' WEST 475.79 FEET FROM THE NORTHEAST CORNER THEREOF; THENCE NORTH 00°08'49'' EAST 158.00 FEET; THENCE WEST PARALLEL WITH THE NORTH LINE OF SAID SUBDIVISION 654.50 FEET; THENCE SOUTH 26°18'57'' EAST TO THE INTERSECTION WITH A LINE EXTENDING WESTERLY THROUGH THE SAID POINT OF BEGINNING AND PARALLEL WITH THE NORTH LINE OF SAID SUBDIVISION; THENCE EAST ALONG SAID EXTENDED LINE TO THE POINT OF BEGINNING; EXCEPTION THEREFROM A STRIP OF LAND 30 FEET WIDE, PARALLEL WITH AND ADJOINING THE WESTERLY LINE OF SAID TRACT, FOR ROAD PURPOSES; SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. TAX PARCEL # 2023059052 MERIDIAN: ASSUMED DATUM: NAVD 88 BENCHMARKS: ORIGINAL BM:FOUND BRASS DISK IN CONCRETE IN THE INTERSECTION OF S 18TH ST AND GRAND AVE S. WGS POINT DESIGNATION : RENT787. NORTHING = 172,295.95 EASTING = 1,302,573.67 ELEV. = 317.57 TBM - A:SET MAG NAIL IN SEAM 2' WEST OF TOP BACK CURB ON WEST SIDEWALK OF GRANT AVE S. ELEV. = 309.81 TBM - B:SET HUB + MAG NAIL 20' +/- E OF SE CORNER OF HOUSE. ELEV. = 318.93 C.O.R. BM:MONUMENT IN CASE IN THE INTERSECTION OF EAGLE RIDGE DRIVE SOUTH AND SOUTH 18TH STREET. RENTON MONUMENT ID #1063 NORTHING = 172,968.69 EASTING = 1,301,533.10 ELEV. = 261.21 LOT AREA TABLE 1 1,076 SF 2 846 SF 3 1,025 SF 4 846 SF 5 1,076 SF 6 1,076 SF 7 846 SF 8 1,025 SF 9 1,076 SF 10 1,076 SF 11 846 SF 12 1,025 SF 13 1,076 SF 14 1,083 SF 15 851 SF 16 1,032 SF 17 851 SF 18 1,083 SF 19 1,083 SF 20 851 SF 21 1,032 SF 22 851 SF 23 1,083 SF 24 1,076 SF 25 846 SF 26 1,025 SF 27 1,076 SF 28 1,076 SF 29 846 SF 30 1,025 SF 31 1,076 SF 32 1,076 SF 33 846 SF 34 1,025 SF 35 846 SF 36 1,076 SF TOTAL 35,630 SF MIN.846 SF MAX.1,083 SF AVG.990 SF TRACT AREA TABLE TRACT A 19,084 SF 0.44 AC TRACT B 12,476 SF 0.29 AC TRACT C 2,595 SF 0.06 AC TOTAL 34,155 SF 0.78 AC NOTE: ALL UTILITIES AND INFRASTRUCTURE PARTIALLY INSTALLED UNDER PERMIT U16004475 ARE SUBJECT TO A PUNCHLIST AND MUST MEET CURRENT CLOSEOUT REQUIREMENTS (SUCH AS: AS-BUILDS, MAINTENANCE BOND, BILL OF SALE, EASEMENTS, DECLARATION OF COVENANT, DEPARTMENT OF HEALTH CONSTRUCTION COMPLETION FORM, PAYMENT OF RECORDING FEES, ETC.) IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 COVERGRANT PLACE TOWNHOMESC1.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429001 PR23-000126N PROPOSED LEGEND GRASSCRETE ACCESS ASPHALT PAVEMENT CONCRETE PAVEMENT PROPERTY BOUNDARY EASEMENT LINE ROW DEDICATION TRACT A (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) TRACT C TREE PRESERVATION TRACT B (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) TRACT B (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) PROPOSED SEWER PROPOSED SEWER EXISTING DETENTION VAULT PROPOSED MAILBOXES (TYP) PROPOSED CROSSWALK (TYP) PROPOSED KEYSTONE WALL (TYP) WITH FENCE ON TOP. FENCE HEIGHT MEASURED FOM THE BOTTOM OF RETAINING WALL SHALL NOT EXCEED 6' PROPOSED SEWER MH PROPOSED SEWER MH CONNECTION TO EXISTING CONNECT TO EXIST SEWER PROPOSED ASPHALT RAMP REPLACE EXISTING CURB AND GUTTER NO PARKING - FIRE LANE SIGN (TYP) STOP SIGN TRACT A (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) DRAWING INDEX C1.0 COVER SHEET TESC PLAN C4.0 C3.1 DRAINAGE PLAN C2.0 VAULT PLAN AND DETAILS TESC NOTES AND DETAILSC2.1 C3.0 GRADING PLAN C5.3 WATER PLAN C4.4 SEWER DETAILS C7.0 HORIZONTAL CONTROL, SIGNAGE, AND STRIPING PLAN DETAILS C4.2 STORMFILTER DETAILS C6.0 TREE RETENTION PLANC8.0 WATER PROFILESC6.1 C4.1 ROAD AND STORM PROFILES C4.3 VAULT DETAILS CONDITIONS OF APPROVALC1.1 BOUNDARY & TOPOGRAPHIC SURVEY (2 SHEETS) NOTESC1.2 C3.2 DETAILS GARBAGE COLLECTION AREA (TYP) C4.5 DETAILS C5.0 SEWER PLAN C5.1 SEWER PROFILES FIRE GATES DETAILC9.0 15' SEWER EASEMENT TO BE RECORDED VAULT ACCESS ENTRANCE GEOTECH: PHIL HABERMAN COBALT GEOSCIENCES, LLC P.O. BOX 82243 KENMORE, WASHINGTON 98028 www.cobaltgeo.com ARBORIST: SHOFFNER CONSULTING4715 1015 TENTH ST. MUKILTEO, WA 98275 (206) 755-9407 tony@tonyshoffner.com LANDSCAPE: TINA VINCENT, PLA, ASLA P.O. BOX 1744 EDMONDS, WA 98020 PHONE: (206) 913-9216 tina@vindesigngrp.com TRAFFIC: AARON VAN AKEN, P.E. HEATH AND ASSOCIATES, INC. PO BOX 397 PUYALLUP, WA 98371 253-770-1401 avanaken@heathtraffic.com ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 REMOVE EX. WATER METER AND CAP AT THE MAIN BY CITY FORCES VAULT MAINTENANCE GRATE VAULT MAINTENANCE GRATE C3.3 DETAILS C4.6 DETAILS C4.7 DETAILS C5.2 SEWER DETAILS WATER DETAILSC6.3 WATER DETAILSC6.2 LIGHT POLE SCHEDULE POLE ID STATION\ OFFSET MOUNTING HEIGHT (FT) ARM LENGTH (FT)VOLTAGE WATTAGE LUMINAIRE\POLE TYPE TBD 4+41.53 (24.92 R) STREET- 35.5' PEDESTRIAN - 16.5' STREET - 8' PEDESTRIAN - 4'TBD STREET SCALE: 105 PED. SCALE: 34 ARTERIAL STREET DECORATIVE LUMINARE POLE AS PER STD. PLAN-117.1, 119, 120, 121 PROPOSED LINEAR DRAIN FIRE SPLINKERS: FIRE SPLINKERS ARE REQUIRED TO BE INSTALLED ON BUILDINGS WITH 5 UNITS: BUILDING 1, 4, 5 AND 8 AS PER NFPA 13 AND IBC2021 L3.3 L1.1 L3.4 L1.2 L3.5 L3.2 L3.1 L3.6 TREE RETENTION PLAN TREE RETENTION PLAN CONCEPTUAL LANDSCAPE PLAN CONCEPTUAL LANDSCAPE PLAN OPEN SPACE PLAN OPEN SPACE PLAN PLANTING & SITE DETAILS PLANTING & SITE DETAILS as a condition of approval applicant shall submit the proposed street light pole and luminaire to the development engineering project manager for review and approval prior to installation. REGIONAL FIRE AUTHORITY cthomas 09/03/2024 APPROVED JDing 09/03/2024 CURRENT PLANNING SURFACE WATER UTILITY JFarah 09/03/2024 WASTEWATER UTILITY jstowell 09/12/2024 WATER UTILITY ABDOUL GAFOUR 09/13/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 ENVIRONMENTAL REVIEW COMMITTEE (ERC) DETERMINATION OF NON-SIGNIFICANCE - MITIGATED (DNS-M) HEARING EXAMINERS FINAL DECISION DECISION: THE PROPOSED PRELIMINARY PLAT ( INCLUDING QUALIFYING AS A UNIT LOT SUBDIVISION), HEARING EXAMINER SITE PLAN, PARKING MODIFICATION, STREET STANDARDS MODIFICATION AND A LANDSCAPE VARIANCE COMPLY WITH ALL APPLICABLE CRITERIA FOR THE REASONS IDENTIFIED IN THE CONCLUSIONS OF LAW OF THIS DECISION AND ARE ALL APPROVED, SUBJECT TO THE FOLLOWING CONDITIONS: 1.A FINAL TREE REPLACEMENT PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE FINAL TREE REPLACEMENT PLAN SHALL INCLUDE THE PLANTING OF AN ADDITIONAL 52.5 TREE CREDITS ON THE PROJECT SITE. 2.THE FLOOR PLANS SHALL BE REVISED TO IDENTIFY THE REQUIRED BICYCLE PARKING SPACE WITHIN THE PROPOSED GARAGES. THE REVISED FLOOR PLANS SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW FOR THE REVIEW AND APPROVAL OF THE CURRENT PLANNING PROJECT MANAGER. 3.REVISED FLOOR PLANS SHALL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW SHOWING THE REQUIRED TWO FEET BY SIX FEET (2' X 6') FLOOR AREA AND SIXTY INCHES (60”) HIGH STORAGE AREA FOR THE INDIVIDUAL REFUSE AND RECYCLING CARTS. IN ADDITION, SITE PLAN SHALL BE REVISED TO INCLUDE SPACE FOR CARTS TO BE PLACED ON GARBAGE PICK-UP DAY. THE SPACE MUST BE SUFFICIENT TO ACCOMMODATE THE NUMBER OF CARTS EXPECTED TO BE SERVICED ON PICK-UP DAY. THERE SHALL BE A DIRECT CONNECTION CONSTRUCTED OF A SMOOTH SURFACE THAT ALLOWS CARTS TO BE SMOOTHLY ROLLED TO THE STREET OR OTHER SPECIFIED PICK-UP LOCATION. THE REVISED SITE PLAN SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF CONSTRUCTION PERMIT REVIEW. 4.A CROSS SECTION WITH TOP AND TOE MEASUREMENTS AND MATERIAL COMPOSITION OF THE PROPOSED RETAINING WALL SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL. 5.A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW INCLUDING A FENCING DETAIL DEMONSTRATING THAT THE TOTAL COMBINED HEIGHT OF ANY FENCING PROPOSED ON TOP OF A RETAINING WALL WOULD NOT EXCEED THE MAXIMUM HEIGHT PERMITTED FOR A STANDALONE FENCE. THE FENCING DETAIL SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL. 6.A REVISED LANDSCAPE PLAN SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. THE REVISED LANDSCAPE PLAN SHALL INCLUDE A THREE-FOOT (3') LANDSCAPED SETBACK BETWEEN ANY RETAINING WALLS AND THE FRONT PROPERTY LINE ALONG GRANT AVE S. 7.THE PROJECT PROPOSAL SHALL INCORPORATE A VARIETY OF ROOFING COLORS AND THAT THE ROOFING MATERIAL SHALL BE FIRE RETARDANT. REVISED COLORED ELEVATIONS DEMONSTRATING COMPLIANCE WITH THIS REQUIREMENT SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW. 8.THE APPLICANT SHALL EITHER SUBMIT REVISED ELEVATIONS PROVIDING THE REQUIRED THREE AND ONE-HALF INCHES (3 1/2") MINIMUM TRIM SURROUNDING ALL WINDOWS AND DOORS AND ONE OF THE FOLLOWING ARCHITECTURAL DETAILS: SHUTTERS, KNEE BRACES, FLOWER BOXES, OR COLUMNS. ALTERNATIVELY, THE APPLICANT MAY SUBMIT AN ALTERNATIVE THAT MEETS THE INTENT AND GUIDELINES OF THE DESIGN SECTION. THE REVISED ELEVATIONS SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT THE TIME OF BUILDING PERMIT REVIEW. 9.A FULLY DETAILED MATERIALS BOARD AND COLOR PALETTE CODED TO EACH BUILDING ELEVATION, SHALL BE PROVIDED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL AT THE TIME OF BUILDING PERMIT REVIEW. 10.THE APPLICANT SHALL SUBMIT A SEPARATE DETAILED UTILITY AND LANDSCAPE PLAN SET IDENTIFYING THE LOCATION AND SCREENING PROVIDED FOR ALL SURFACE UTILITY/MECHANICAL EQUIPMENT REQUIRED FOR EACH TOWNHOME. THE SURFACE MOUNTED UTILITY PLAN SHALL INCLUDE CROSS-SECTION DETAILS AND SCREENING MEASURES CONSISTENT WITH THE OVERALL DESIGN OF THE DEVELOPMENT WITH THE CIVIL CONSTRUCTION PERMIT APPLICATION. THE APPLICANT SHALL WORK WITH FRANCHISE UTILITIES TO ENSURE, AS PRACTICAL, UTILITY BOXES ARE LOCATED OUT OF PUBLIC ROW VIEW, ACTIVE COMMON OPEN SPACES, AND THEY SHALL NOT DISPLACE REQUIRED LANDSCAPING AREAS. THE UTILITY AND LANDSCAPE PLAN SET SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO PERMIT ISSUANCE. 11.A SIX-INCH (6”) VERTICAL CURB SHALL BE INSTALLED BETWEEN THE UNIT LOT DRIVEWAY AND ABUTTING LANDSCAPED AREAS. REVISED CIVIL PLANS SHOWING THE CURB SHALL BY SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. 12.THE APPLICANT SHALL CREATE A HOMEOWNERS' ASSOCIATION (“HOA”) THAT MAINTAINS ALL IMPROVEMENTS AND LANDSCAPING IN THE COMMON OPEN SPACE TRACTS AND ANY AND ALL OTHER COMMON IMPROVEMENTS. THE HOA DOCUMENTS SHALL BE SUBMITTED TO, AND APPROVED BY, THE CURRENT PLANNING PROJECT MANAGER PRIOR TO RECORDING OF THE UNIT LOT SUBDIVISION. SUCH DOCUMENTS SHALL BE RECORDED CONCURRENTLY WITH THE UNIT LOT SUBDIVISION. 13.ALL TRACTS (E.G. UNIT LOT DRIVEWAY, DRAINAGE, OPEN SPACE, ETC.) SHALL BE PLACED WITHIN SEPARATE TRACTS THAT WOULD BE OWNED AND MAINTAINED BY THE HOMEOWNER'S ASSOCIATION. 14.ALL PRIVATE OPEN SPACE AREAS ATTRIBUTED TO EACH INDIVIDUAL DWELLING UNIT SHALL BE LOCATED ON THE SAME UNIT LOT AS THE DWELLING UNIT. A REVISED PLAT MAP SHALL BE SUBMITTED AT THE TIME OF CONSTRUCTION PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER, THAT DEMONSTRATES COMPLIANCE WITH THIS REQUIREMENT. 15.THE APPLICANT SHALL BE REQUIRED TO DEMONSTRATE SAFE WALKING CONDITIONS TO/FROM THE SUBJECT PLAT TO BUS STOP LOCATIONS PRIOR TO CONSTRUCTION PERMIT ISSUANCE. PROJECT FILE NUMBERS: PR23- 000126 / LUA23- 000283, PP, SA- H, ECF, MOD, V-H PROJECT NAME: GRANT PLACE TOWNHOMES APPLICANT: SATWANT SINGH, 15 S GRADY WAY, SUITE 527, RENTON, WA 98057 PROJECT LOCATION: 1504- 1582 SE GRANT CIRCLE, RENTON, WA 98055 ( PARCEL NO. 2023059052) PROJECT DESCRIPTION: THE APPLICANT IS REQUESTING PRELIMINARY PLAT APPROVAL, HEARING EXAMINER SITE PLAN REVIEW, ENVIRONMENTAL ( SEPA) REVIEW, A PARKING MODIFICATION, A STREET STANDARDS MODIFICATION, AND A LANDSCAPE VARIANCE FOR THE CONSTRUCTION OF A MULTI- FAMILY DEVELOPMENT CONTAINING A UNIT LOT SUBDIVISION WITH 36 TOWNHOMES. THE PROJECT SITE TOTALS APPROXIMATELY 2.14 ACRES AND IS LOCATED WITHIN THE RESIDENTIAL MULTI- FAMILY ( RMF) ZONING CLASSIFICATION, AND THE RESIDENTIAL HIGH DENSITY ( RHD) LAND USE DESIGNATION. THE DEVELOPMENT WOULD BE COMPRISED OF EIGHT ( 8) SEPARATE MULTI- FAMILY RESIDENTIAL STRUCTURES. ACCESS TO THE SITE IS PROPOSED VIA NEW LOOP ACCESS DRIVE EXTENDED FROM GRANT AVE S. A PARKING MODIFICATION IS REQUESTED AS THE PARKING STALLS WOULD NOT COMPLY WITH THE MINIMUM DIMENSIONAL REQUIREMENT, A LANDSCAPE SETBACK VARIANCE IS REQUESTED TO VARY FROM THE 15-FOOT BUFFER REQUIRED ABUTTING A RESIDENTIALLY ZONED PROPERTY, AND A STREET STANDARDS MODIFICATION WAS REQUESTED TO MODIFY THE UNIT LOT DRIVEWAY STANDARDS. THE PROPOSED DEVELOPMENT IS LOCATED ON A PARTIALLY- DEVELOPED SITE THAT WAS ORIGINALLY PART OF THE EXPIRED GRANT PLACE TOWNHOMES PRELIMINARY PLAT AND PLANNED URBAN DEVELOPMENT ( PUD) (LUA15- 000885 AND LUA17- 000335). THE PRELIMINARY PLAT AND PUD APPLICATIONS HAVE EXPIRED AND THE PROPOSED TOWNHOME DEVELOPMENT WOULD REQUIRE NEW LAND USE APPROVALS. THE SITE IS MAPPED WITH SENSITIVE SLOPES, MODERATE COAL MINE HAZARDS, MODERATE LANDSLIDE HAZARDS, HIGH EROSION HAZARDS, AND SEISMIC FAULTS. LEAD AGENCY: CITY OF RENTON ENVIRONMENTAL REVIEW COMMITTEE DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT DATE OF DECISION: SEPTEMBER 18, 2023 MITIGATION MEASURES: 1.PROJECT CONSTRUCTION SHALL COMPLY WITH THE RECOMMENDATIONS OUTLINED IN THE GEOTECHNICAL REPORT PREPARED BY NELSON GEOTECHNICAL ASSOCIATES, INC., DATED JUNE 10, 2005 AS WELL AS THE GEOTECHNICAL LETTER PREPARED BY COBALT GEOSCIENCES, LLC, DATED MARCH 3, 2023. 2.THE APPLICANT SHALL SUBMIT AN INADVERTENT DISCOVERIES PLAN PREPARED BY A QUALIFIED PROFESSIONAL WITH THE CIVIL CONSTRUCTION PERMIT FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO PERMIT ISSUANCE. 3.THE DUWAMISH TRIBE SHALL ALSO BE NOTIFIED IF ANY ARCHEOLOGICAL WORK OR MONITORING IS PERFORMED ON THE PROJECT SITE. THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMITTEE HAS DETERMINED THAT PROBABLE SIGNIFICANT ENVIRONMENTAL IMPACTS FROM THE PROPOSED PROJECT CAN BE MITIGATED. AN ENVIRONMENTAL IMPACT STATEMENT ( EIS) IS NOT REQUIRED UNDER RCW 43.21C.030(2)(C). CONDITIONS WERE IMPOSED AS MITIGATION MEASURES BY THE ENVIRONMENTAL REVIEW COMMITTEE UNDER THEIR AUTHORITY OF SECTION 4-9-070D RENTON MUNICIPAL CODE. THESE CONDITIONS ARE NECESSARY TO MITIGATE ENVIRONMENTAL IMPACTS IDENTIFIED DURING THE ENVIRONMENTAL REVIEW PROCESS. ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 CONDITIONS OF APPROVALGRANT PLACE TOWNHOMESC1.1LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429002 PR23-000126NOTE: STANDARD PLANS REQUIRES STRUCTURAL CALCULATIONS FOR THE FOUNDATION. CONDITION TO BE ADDED ON PERMIT THAT SUCH CALCULATIONS SHALL BE PROVIDED PRIOR TO INSTALLATION OF FOUNDATION. as a condition of approval structural calculations for the foundation design shall be submit to the development engineering project manager prior to installation. DEVELOPMENT ENGINEERING NJanders 09/16/2024 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 NOTESGRANT PLACE TOWNHOMESC1.2LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429003 PR23-000126DEVELOPMENT ENGINEERING NJanders 09/16/2024 HIGH VISIBILITY SILT FENCE LIMITS OF CLEARING AND GRADING TREE TO BE PROTECTED - ORANGE BARRIER FENCE INLET PROTECTION STABILIZED CONSTRUCTION ENTRANCE INTERCEPTOR SWALE WITH ROCK CHECK DAM LEGEND CONSTRUCTION NOTES FLAG CLEARING LIMITS TO EXTENTS SHOWN ON THE PLAN. HIGH VISIBILITY SILT FENCE PER DETAIL SHEET C2.1 CONSTRUCTION ENTRANCE PER DETAIL SHEET C2.1 CATCH BASIN INSERT PER DETAIL SHEET C2.1 INTERCEPTOR DITCH W / ROCK CHECK DAMS PER DETAIL SHEET C2.1 TREE PROTECTION FENCE MULCH SITE PER SWDM SECTION C.3.2 VAULT TO BE USED TO STORE SEDIMENT-LADEN STORMWATER DURING CONSTRUCTION 1 2 3 4 5 6 7 8 1 2 1 2 1 2 3 4TYP 1 2 5 5 5 55 5 23 8 7 7 7 7 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 TESC PLANGRANT PLACE TOWNHOMESC2.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429004 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 CONSTRUCTION SEQUENCE 1.PRE-CONSTRUCTION MEETING. 2.POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN). 3.FLAG OR FENCE CLEARING LIMITS. 4.INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5.GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 6.INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7.CONSTRUCT SEDIMENT PONDS AND TRAPS. 8.GRADE AND STABILIZE CONSTRUCTION ROADS. 9.CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 10.MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS. 11.RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS. 12.COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT. 13.STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS. 14.SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 15.UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE. IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 TESC NOTES AND DETAILSGRANT PLACE TOWNHOMESC2.1LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429005 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 EXIST STORM DRAINAGE STRUCTURE TABLE ID SDCB-T1 SDMH-T2.1 SDMH-T2.2 DESCRIPTION CB-TYPE 1 SDMH TYPE 2 SDMH TYPE 2 RIM ELEV EL 307.41 EL 307.91 EL 305.30 PIPE INVERT 12" (SW) EX CMP IE=303.06 12" (NE) RCP IE=303.24 12" (NW) EX CMP IE=302.95 12" (NE) EX CMP IE=302.95 12" (SW) RCP IE=303.63 STATION OFFSET 10+24.68 32.114L 10+46.92 33.577L 9+89.49 28.654L DRAIN 1ST FF= 316.73 2ND FF= 326.08 1ST FF= 317.77 2ND FF= 328.08 1ST FF= 318.35 2ND FF= 328.08 1ST FF= 318.91 2ND FF= 328.08 1ST FF= 320.0 2ND FF= 330.08 1ST FF= 322.61 2ND FF= 331.85 1ST FF= 324.61 2ND FF= 333.77 1ST FF= 331.59 2ND FF= 341.57 1ST FF= 330.35 2ND FF= 340.19 1ST FF= 325.70 2ND FF= 335.27 1ST FF= 325.95 2ND FF= 335.27 1ST FF= 327.35 2ND FF= 336.77 1ST FF= 323.80 2ND FF= 333.95 1ST FF= 324.02 2ND FF= 333.95 1ST FF= 325.81 2ND FF= 337.00 1ST FF= 333.31 2ND FF= 343.03 1ST FF= 333.44 2ND FF= 343.03 1ST FF= 334.94 2ND FF= 344.56 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 333.47 2ND FF= 343.08 1ST FF= 348.19 2ND FF= 357.98 1ST FF= 349.75 2ND FF= 359.52 1ST FF= 351.13 2ND FF= 361.03 1ST FF= 352.61 2ND FF= 362.52 1ST FF= 354.23 2ND FF= 364.01 1ST FF= 348.25 2ND FF= 357.99 1ST FF= 349.53 2ND FF= 359.48 1ST FF= 350.87 2ND FF= 360.98 1ST FF= 352.46 2ND FF= 362.52 1ST FF= 353.96 2ND FF= 364.01 1ST FF= 314.90 2ND FF= 324.73 1ST FF= 315.92 2ND FF= 325.92 1ST FF= 316.10 2ND FF= 325.92 1ST FF= 316.60 2ND FF= 325.92 1ST FF= 317.57 2ND FF= 327.57 BUILDING #2 BUILDING #3 BUILDING #4 BUILDING #5 BUILDING #6BUILDING #7 BUILDING #8 BUILDING #1 60' R.O.W. INSTALL WOOD FENCE ALONG EAST PROPERTY LINE, SEE LANDSCAPE PLANS FOR DETAIL INSTALL WOOD FENCE ALONG SOUTH PROPERTY LINE, SEE SHEET C3.1 FOR DETAIL 20' WIDE TYPE C1B DRIVEWAY APPROACH PER RENTON STD PLAN 104.4, SIDEWALK AT DRIVEWAY CROSSING SHOULD NOT BE DEPRESSED AT LOCATIONS WHERE LANDSCAPING IS MORE THAN 5 FEET WIDE STREET NAME SIGN, ONE WAY SIGN AND DO NOT ENTER SIGN SEE SHEET C3.2 20' WIDE TYPE C1B DRIVEWAY APPROACH PER RENTON STD PLAN 104.4, SIDEWALK AT DRIVEWAY CROSSING SHOULD NOT BE DEPRESSED AT LOCATIONS WHERE LANDSCAPING IS MORE THAN 5 FEET WIDE GRANT AVE S TOP: 302.7 TOP: 308.0 TOP: 312.9 TOP: 316.7 TOP: 318.1 TOE: 318.7 TOE: 320.0 GRANT CIRCLE S.E. GRANT CIRCLE S.E. PRIVATE ALLEY 34234430 4298 308310314308.20 307.50 6.3%2 . 8%0.3%0.1%2.6% 0.5%302315.11 0.7%0.5%1.4%4.1%6.5%5.6%7.0%7.0%5.9%4.6%6.7%330328338332 3343363 3 8 340 342 344 344 342340338336314312310308304302300 316318312314341.73 342.54 3463483503523543563543 5 4 3563 5 2 297.39 295.63 295.57 297.25 305.94 306.60 304.01 303.93 304.05 1.5% 1.5%2.0%2.0%1.5%16' 4' 4' 4' 4' 3.1%0.8%4.4% 4.5%2.2%0.9%3.9%1.3%2.4%18' 8' 5' 5' 307.43 314.54 340.29 342.96 345.11 318.46 313.24 15.8% 17.6%2.1%1.3%3.5%1.8%1.8%1.5%3006.3% 1.1% 308.48306.63 TOP: 301.5 TOE: 297.6 TOP: 304.0 TOE: 300.2 TOP: 306.9 TOE: 306.8 6.1% TOP: 306.0 TOE: 304.9 318.61 344TOP: 305.3 TOE: 301.7 7.0% 20' PRIVATE ALLEY ACCESS & PUBLIC UTILITY EASEMENT 20' PRIVATE ALLEY ACCESS & PUBLIC UTILITY EASEMENT 3464' TYP 20' 1.5' ROW DEDICATION 3 2 6 TOP: 343.0 TOE: 342.3 TOP: 343.1 TOE: 341.7 TOP: 343.2 TOE: 341.11.9%319.16 1.7% 313.31 3.4%318.78 326.26 325.50 325.30 325.12 325.12 328.01 328.82 327.69 329.52 325.38 1.8%1.4% 330.62 332.75 334.51 334.62 334.84 334.69 334.34 321.92 322.50 323.61 334.47 336.40 336.94 336.50 323.03 336.52 338.02 339.72 340.86 340.85 343.09 341.84 341.94 340.64 343.50 340.81 340.70 342.63 343.00 346.49 346.52 348.52 348.72 350.49 353.46 353.72 354.99 355.43 356.54 351.01 348.57 352.53 343.68 356.97 357.13 357.30 359.62 357.87 357.43 355.67 BACK OF WALK 355.22 355.67 357.43 357.86 359.62 359.03 358.91 358.70 358.06 356.79355.01 354.88 353.67 353.39 351.01 350.37 347.42 357.31350.49 350.61 352.98 357.66 359.15 362.19 4' 16' 4' 16' 4' 16'324330326324322316.73 317.78 318.41 318.96 320.00 324.62 325.70 325.95 327.35 MAIL BOX (TYP) SEE DETAIL SHEET C3.2 OR SIMILAR 315.92314.88 316.10 316.60 317.57 322.61 323.80 324.42 325.811.5%1.4%1.7%1.8%1.7%1.5%1.2%351.13 350.87 352.61 354.23 352.46 353.96349.53 318.62 348.25 313.92 349.75 348.19 331.59 333.16 333.59 334.93 330.38 331.80 331.80 333.462.0%2.0%4.4%4.2%4.8% 4.1%5.6%4.0% 363.68 MAIL BOX (TYP) SEE DETAIL SHEET C3.2 OR SIMILARTRASH COLLECTION STAGING (TYP) 313.546.2%0.6% TRASH COLLECTION STAGING (TYP) 342.75339.86336.66 325.56 333.53 307.09 340.48 3 6 0350 INSTALL SPLIT RAIL WOOD FENCE ALONG TREE PRESERVATION TRACT PROPERTY LINE, SEE LANDSCAPE PLANS FOR DETAIL TOE: 319.8 346.01 360.65 363.68 362.19360.70359.19 357.65 344.97 337.71 341.22341.22 333.4131.4%342.70 342.70 344.23 337.07 342.30 29.9%344336.43 334.93334.93 333.43 333.61333.61 2.6%0.1%3.0%2.0%1.6% 331.51 327.23 14.6%325.58325.58325.58 20.0%329.74 327.74327.74327.74325.74 324.39 2.8%3.5%1.3%3.3%4.2% 3.0% 23.4% 28. 5 %14.1%344346348352 35816.2% 15.0%14.9% 20.6% TOP: 306.0 TOE: 303.4 TOP: 302.9 TOE: 300.3 TOP: 312.2 TOE: 308.3 3.1%2.5%1.7%6.4%0.4%358332 320TOE: 340.0 TOE: 339.5 TOP: 343.0 TOE: 342.3 TOE: 350.9 TOE: 355.4 TOE: 356.9 TOE: 357.2 TOE: 355.8 TOE: 357.9 TOE: 357.3 TOE: 360.5 TOE: 360.7 TOE: 357.4 TOP: 337.8 TOE: 337.8 TOP: 341.2 TOE: 339.3 TOP: 341.6 TOE: 341.4 3.7%5.7%6.0%1.8%5.6%2.4%7.2%16.0%2.4%1. 2 % 10.6%3043 5 0 3483 5 8 356356358 36 2 29829632432832632 6 324330332334334 336336332 334 3 4 0 20' TOE: 301.3 EG 294.33 EG 294.37 6.5% GRANT AVE S: 4+84.98 GRANT AVE S:3+58.81 ULTRA BLOCK RET. WALL. WALL FACE TO BE 12" AWAY FROM THE PROPERTY LINE (TYP.) 1.8'294.77 321.51 TOE: 306.5 NEW STREET LIGHT POLE ALIGNMENT: GRANT AVE S STA: 4+41.53 TOE: 311.0 TOE: 314.1 TOE: 316.3 TOP: 319.2 TOP: 320.2 TOP: 320.8 TOP: 340.9 TOP: 339.5 TOP: 351.4 TOP: 358.0 TOP: 359.8 TOP: 360.1 TOP: 360.5 TOP: 362.1 TOP: 363.1 TOP: 360.2 TOP: 359.3 TOP: 355.7 TOP: 343.5TOE: 341.8 TOP: 346.9 TOE: 350.3 TOP: 355.5 TOE: 356.8 TOP: 359.0TOE: 358.7 INSTALL WOOD FENCE ALONG SOUTH PROPERTY LINE, SEE SHEETS C3.1 AND C3.2 FOR DETAIL 12' 307.08 306.42 307.30 307.09 306.48 EG 307.78 EG 307.39 305.97 7.3%4.2% 1.5% 7.0% 1.7% 294.83 EG 294.33 EG 294.37 6.5% 8' LANDSCAPE R.O.W.EX. R.O.W.EXISTING SIDEWALK EXISTING CURB (TYPICAL) 30' EXISTING PAVEMENT 4" THICK CONCRETE SIDEWALK 31.5' PUBLIC 1/2 R.O.W. 30'5' SIDEWALK PROP. R.O.W.18.0' CURB 1.5' R.O.W. DEDICATION 6" 60' R.O.W. 1.5%2% CL SAWCUT LINE 3' 12" 4'PROPERTY LINECURB ULTRA BLOCK WALL TOWNHOUSE2% NOTE: PAVEMENT THICKNESS PER TYPICAL DETAIL ON SHEET C3.0 20' PRIVATE ALLEY ACCESS 4' CONCRETE WALK 16' ASPHALT DRIVE LANE ONE WAY 3' 3:1 MAX. SLOPES VARIES 2:1 MAX 1.5% 7' CURB TOWNHOUSEPROPERTY LINE2% 3:1 MAX . FENCE 20' PRIVATE ALLEY ACCESS 4' CONCRETE WALK16' ASPHALT DRIVE LANE ONE WAY 3' NOTE: PAVEMENT THICKNESS PER TYPICAL DETAIL ON SHEET C3.0 SLOPES VARIES 2:1 MAX 1.5% CURB 2% 4" THICK CONCRETE SIDEWALK 4' SIDEWALK 1.5% 20' PRIVATE ALLEY ACCESS 4' CONCRETE WALK 16' ASPHALT DRIVE LANE ONE WAY 3:1 MAX . CEMENT CONCRETE PEDESTRIAN CUBR AS PER STD.PLAN-101 NOTE: PAVEMENT THICKNESS PER TYPICAL DETAIL ON SHEET C3.0 1.5%3:1 MAX . 4' CONC 4' CONC 3'3'TOWNHOUSETOWNHOUSE2% 12' ASPHALT DRIVE LANE 2% 20' PRIVATE ALLEY ACCESS NOTE: PAVEMENT THICKNESS PER TYPICAL DETAIL ON SHEET C3.0 SLOPES VARIES 2:1 MAX 1.5%1.5%PROPERTY LINETOWNHOUSE4' 22' 15' 4" CONCRETE SIDEWALK 1.5%VARIES 3:1 MAX. ULTRA BLOCK RET. WALL PROPERTYLINETOWNHOUSE4" CONCRETE SIDEWALK 6'4'6' 1.5%VARIES 3:1 MAX. 3:1 MAX. ULTRA BLOCK RET. WALL AGGREGATE BASE 6" COMPACTED DEPTH EG. GRADE 4" HMA CL. 1/2 IN. COMPACTED DEPTH 10" GEOTEXTILE EARTHWORKS CALCS: CUT: 431 CU YD FILL:1,892 CU YD NET:1,461 CU YD [FILL] LEGEND: GRASSCRETE SERVICE DRIVEWAY FOR STORM VAULT MAINTENANCE SEE SH. C3.2 ASPHALT PAVEMENT CONCRETE PAVEMENT 5' WIDE(MIN) TRANSITION TO EX. CONC. SIDEWALK EX. WATER METER TO BE REMOVED AND CAPPED AT MAIN BY CITY FORCES UNDER SEPARATE PERMIT. ELECTRIC TRANSFORMER, AND TELEPHONE BOX TO BE RELOCATED AS REQ. NOTE: SEPARATE PERMITS FROM UTILITY OWNERS REQUIRED 5' MIN. WIDE A.C. RAMP NOTE: THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS-BUILT CONDITIONS. ADDITIONAL AS-BUILT SURVEY REQIRED TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER. N 60303015 FEETSCALE: 0 1 INCH = 30 PROPERTY BOUNDARY EASEMENT LINE ROW DEDICATION TRASH COLLECTION STAGING AREA 8-UNIT CLUSTER MAILBOX ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 PAVING AND GRADING PLANGRANT PLACE TOWNHOMESC3.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429006 PR23-0001269.69' NOTE: RESTORATION WITHIN GRANT AVE SHALL COMPLY WITH THE CITY'S OF RENTON TRENCH AND RESTORATION STANDARDS. SEE DETAILS ON SCH. C3.2 NOTE: GRANT CIRCLE SE TO BE CLEARED FROM EX. TEMPORARY PAVEMENT AND TO BE REPAVED AS PER DETAIL. NOTE: NO WORKS SHALL BE DONE ON ADJACENT PRIVATE PROPERTY UNLESS A TEMPORARY CONSTRUCTION EASEMENT HAS BEEN RECORDED WITH KING COUNTY AND PROVIDED TO THE DEVELOPED ENGINEERING PROJECT MANAGER FOR REFERENCE. DEVELOPMENT ENGINEERING NJanders 09/16/2024 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC3.1LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429007 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 980263'-4"MIN. 12" DEVELOPMENT ENGINEERING NJanders 09/16/2024 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC3.2LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429008 PR23-000126SHRUB MASS ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 GROUNDCOVER COMPACTED SANDY GRAVEL ROADBASE V: 1"=10' H: 1"=30' NORTH PL BORDER FENCE SECTION DEVELOPMENT ENGINEERING NJanders 09/16/2024 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TRO-41-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC3.2LUA23-000283C23006099GRANT PLACE TOWNHOMEST-429001 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 STOP ONE WAY DO NOT ENTER NO PARKING FIRE LANE DEVELOPMENT ENGINEERING NJanders 09/16/2024 DRAIN 1ST FF= 316.73 2ND FF= 326.08 1ST FF= 317.77 2ND FF= 328.08 1ST FF= 318.35 2ND FF= 328.08 1ST FF= 318.91 2ND FF= 328.08 1ST FF= 320.0 2ND FF= 330.08 1ST FF= 322.61 2ND FF= 331.85 1ST FF= 324.61 2ND FF= 333.77 1ST FF= 331.59 2ND FF= 341.57 1ST FF= 330.35 2ND FF= 340.19 1ST FF= 325.70 2ND FF= 335.27 1ST FF= 325.95 2ND FF= 335.27 1ST FF= 327.35 2ND FF= 336.77 1ST FF= 323.80 2ND FF= 333.95 1ST FF= 324.02 2ND FF= 333.95 1ST FF= 325.81 2ND FF= 337.00 1ST FF= 333.31 2ND FF= 343.03 1ST FF= 333.44 2ND FF= 343.03 1ST FF= 334.94 2ND FF= 344.56 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 333.47 2ND FF= 343.08 1ST FF= 348.19 2ND FF= 357.98 1ST FF= 349.75 2ND FF= 359.52 1ST FF= 351.13 2ND FF= 361.03 1ST FF= 352.61 2ND FF= 362.52 1ST FF= 354.23 2ND FF= 364.01 1ST FF= 348.25 2ND FF= 357.99 1ST FF= 349.53 2ND FF= 359.48 1ST FF= 350.87 2ND FF= 360.98 1ST FF= 352.46 2ND FF= 362.52 1ST FF= 353.96 2ND FF= 364.01 1ST FF= 314.90 2ND FF= 324.73 1ST FF= 315.92 2ND FF= 325.92 1ST FF= 316.10 2ND FF= 325.92 1ST FF= 316.60 2ND FF= 325.92 1ST FF= 317.57 2ND FF= 327.57 BUILDING #2 BUILDING #3 BUILDING #4 BUILDING #5 BUILDING #6BUILDING #7 BUILDING #8 BUILDING #1 EX.SFMH#1 EX 104LF 12" LCPE @ 7.17% EX 53LF 12" LCPE @ 9.09% 14LF 12" LCPE @ 9.71% EX 34LF 12" LCPE @ 40.13% EX 106LF 12" LCPE @ 7.72% EX 103LF 12" LCPE @ 7.74% EX 87LF 12" LCPE @ 4.39%EX 82LF 12" LCPE @ 14.06% EX 24LF 12" LCPE @ 50.38% EX 16LF 12" LCPE @ 2.25% EX 28LF 12" LCPE @ 0.18% EX 34LF 12" LCPE @ 20.98% EX 48LF 12" LCPE @ 3.02% EX 43LF 12" LCPE @ 10.65% EX 30LF 12" RCP @ 79.36% EX 103LF 12" RCP @ 10.05%EX 103LF 12" RCP @ 9.01% EX SDMH-1 CB #2 EX. CB #1 EX.CB #17 EX.CB #16300300 310310320320330330340340296298298302302304 304 3063063083083123123143143163 1 6 3183183223223243243263263283283323323343343363363 3 8338 342 342 344 344 3503463483 5 2 3543 5 6 3403383363343323303283 2 6326 3243 2 2320318316 32 4 332 334 332 334 352 3 5 4 3563583 5 8 358 3 6 0 358356354352350 308EX.CB #6 346EX.CB #8 EX.CB #10EX.CB #9 EX.CB #11 EX.CB #12 EX.CB #13 EX.CB #7 EX.CB #15 EX.CB #14 RAISE EX. MH RIM WITH ONE 2' SECTION 12LF 12" LCPE @ 9.30% CB #3 EX 105LF 12" RCP @ 4.99% EX.CB #18 E X 5 5 L F 1 2 " R C P @ 0 . 6 0 % CB #4 LINEAR DRAIN 26LF @2% EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 EX. CB #1 EX.CB #6 EX.CB #7 EX.CB #8 EX.CB #9 EX.CB #10 EX.CB #11 EX.CB #12 EX.CB #13 EX.CB #14 EX.CB #15 EX.CB #16 EX.CB #17 EX.CB #18 EX.SFMH#1 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-48"Ø GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-72" SOLID LID RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 EL 306.95 EL 345.08 EL 354.82 EL 303.51 EL 315.69 EL 319.95 EL 327.12 EL 335.01 EL 340.48 EL 297.71 EL 317.65 EL 325.70 EL 335.01 EL 341.06 EL 300.76 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 12" (N) LCPE IE=302.54 12" (NW) LCPE IE=341.60 12" (E) LCPE IE=341.60 12" (W) LCPE IE=349.02 12" (E) LCPE IE=300.63 12" (S) LCPE IE=300.63 12" (E) LCPE IE=312.18 12" (W) LCPE IE=312.18 12" (E) LCPE IE=315.99 12" (W) LCPE IE=315.99 12" (E) LCPE IE=323.97 12" (W) LCPE IE=323.97 12" (W) LCPE IE=332.19 12" (E) LCPE IE=332.19 12" (SE) LCPE IE=336.82 12" (W) LCPE IE=336.82 12" (E) LCPE IE=288.17 12" (SE) LCPE IE=288.37 12" (W) LCPE IE=288.17 12" (SW) RCP IE=312.67 12" (E) RCP IE=312.67 12" (W) RCP IE=323.03 12" (E) RCP IE=323.03 12" (W) RCP IE=332.34 12" (E) RCP IE=332.34 12" (W) RCP IE=337.59 12" (SE) RCP IE=337.59 12" (W) LCPE IE=288.52 12" (S) LCPE IE=290.82 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 10.824L 5+45.00 14.654L 1+18.16 0.970L 0+82.63 9.047L 1+64.76 9.050L 2+51.50 9.019L 3+54.63 9.096L 4+61.08 8.799L 4+99.46 8.262L 0+50.85 16.247L 9+45.82 56.554R 8+42.71 54.675R 7+39.37 54.830R 5+64.03 32.526R 0+64.41 9.834L DRAIN GRASSCRETE SERVICE DRIVEWAY FOR STORM VAULT MAINTENANCE ASPHALT PAVEMENT CONCRETE SIDEWALK NOTE: STORM FACILITIES HAVE BEEN INSTALLED UNDER AN EXPIRED PERMIT AND REFLECT AS-BUILT CONDITIONS. SURVEY IE AND RIM ELEVATIONS ARE PROVIDED FOR THE REFERENCE ONLY, USE STRUCTURES TABLE FOR THE PROPOSED FINAL ELEVATIONS. EX STORM DRAIN PIPE EX TYPE 1 CATCH BASIN EX TYPE 2 STORM DRAIN MANHOLE N 3 CONSTRUCTION NOTES CONTROL STRUCTURE - SEE DETAIL SHEET C4.3 WATER QUALITY CONTROL STRUCTURE - SEE DETAIL SHEET C4.3 EX STORMWATER DETENTION VAULT - 90.1' X 40.8' - SEE DETAIL SHEET C4.3 4" PERF PVC SDR 35 FOOTING DRAIN 6" PVC ROOF DRAIN @ 2% MIN (TYP.) INSTALL STORM FILTERS AFTER CLEANING ALL CATCH BASINS AND PIPES 1 2 3 4 5 6 1 2 SD 4 4 5 5 PROPOSED LEGEND STORM DRAINAGE NOTES ALL RIM ELEVATIONS CALLOUTS SHOWN IN THE DEVELOPMENT ARE EXISTING ELEVATION. THE FINAL RIM ELEVATIONS ARE SHOWN IN THE STRUCTURE DRAINAGE TABLE ON THIS PAGE. 1 2 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DRAINAGE CONTROL PLANGRANT PLACE TOWNHOMESC4.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429009 PR23-000126NOTE: ALL STORM SYSTEM FACILITIES UPSTREAM EX.SDMH-1 ARE PRIVATE. SEE SEPARATION NOTES CL TO CL 5.00'SEE SEPARATION NOTES 6.13'CL TO CL 6.27'CL TO CL 5.19'NOTE: THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS-BUILT CONDITIONS. ADDITIONAL AS-BUILT SURVEY REQIRED TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER. PROPOSED IE AND RIM ELEVATION TAKES PRECEDENCE OVER SURVEY DATA. RELOCATE EX. STORM PIPING FROM EX.CB#1 TO CB#5CL TO CL 5.28'TACK COAT FACE OF CUT AND EACH COURSE MINNOTES: 2. ALTERNATE TRENCH DRAIN FOR REVIEW AND APPROVAL. SPECIFICATION MAY BE SUBMITTED MATERIAL OR STRUCTURAL FILL. AGAINST COMPETENT NATIVE 1. BASE SHALL BE POURED W/QUICKLOCK ASS'Y. ACO SLOTTED STEEL GRATE 4" HMA 6" COARSE FILL MIN.MIN. 6"6"8"SEE PLOFILEVARIESACO FRAME MESH STEEL 5 1/2 SACK MIX POUR IN PLACE CONC. BASE ACO 12" TRENCH DRAIN K300 CLASS B FORMED IN PLACE TRENCH DRAIN FOR CHANNEL INVERTS/SLOPE(S). AND/OR UTILITY PLAN SEE STORM PLAN #3 REBAR CONTINUOUS (TYP)4000 PSI @ 28 DAYS PER PLAN 3" CLR4"CLR#3 REBAR @ 6" O.C.3"CLRNEW STRUCTURAL FILL, COMPACT (ASTM D1557) SURFACE WATER UTILITY JFarah 09/03/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 EX.CB #6 12" IE 341.60 (E) 12" IE 341.59 (NW) RIM EL 345.08 30LF 12" RCP @ 79.36% 103LF 12 " R C P @ 1 0 . 0 5 % 103LF 12" R C P @ 9 . 0 1 % EX.CB #17 12" IE 332.34 (W) 12" IE 332.34 (E) RIM EL 335.01 EX.CB #16 12" IE 323.03 (W) 12" IE 323.03 (E) RIM EL 325.70 GRANT AVENUE SEX R.O.W. 2' ROW DEDICATION BLDG 4 & 5 LOT LINE (TYP)EX.CB #7 12" IE 349.02 (W) RIM EL 354.82 EAST PLEX.CB #15 12" IE 312.67 (SW) 12" IE 312.67 (E) RIM EL 317.65 GRANT CRCLFACE OF EX CURBBLDG 1, 8 BLDG 2, 7 BLDG 3, 6 VAULT INLET STA: 0+85.08 ELEV: 289.21 EX. SEWER EX.SSMH #7 8" IE OUT 343.49 (W) RIM EL 354.13 STA 5+73.32 EX.SSMH #6 8" IE IN 335.16 (E) 8" IE OUT 335.16 (S) RIM EL 345.05 STA 4+76.92 104LF 12" LC P E @ 7 . 1 7 % WATER 10" D.I.105LF 12" RCP @ 4 . 9 9 % EX.CB #18 12" IE 337.59 (W) 12" IE 337.59 (SE) RIM EL 341.06 55LF 12" RCP @ 0.60% CB #4 12" IE 337.92 (NW) RIM EL 340.60 3.94% 15.0 0 % 0.13% 9.96% 1.52% 7.10% BLDG 8 CB #2 12" IE 303.89 (W) 12" IE 303.89 (E) 12" IE 303.89 (N) RIM EL 307.56 14LF 12" LCPE @ 9.71%EX. CB #1 12" IE 302.54 (E) 12" IE 302.54 (N) RIM EL 306.95EL: 320.30PVI STA: 9+51.80 PVI EL: 313.84 K: 1.81 BVC STA: 9+41.80EL: 314.23EVC STA: 9+61.80EL: 312.3420' VC PVI STA: 10+00.68 PVI EL: 306.51 K: 3.97 BVC STA: 9+90.68EL: 308.01EVC STA: 10+10.68EL: 305.5120' VC PVI STA: 8+70.45 PVI EL: 317.05 K: 4.63 BVC STA: 8+51.99EL: 319.24EVC STA: 8+88.91EL: 316.3237' VC GRANT AVENUE SEX R.O.W. 2' ROW DEDICATION EX.SSMH #3 STA 9+57.59 8" IE IN 305.28 (N) 8" IE IN 305.28 (E) 8" IE OUT 305.23 (SW) RIM EL 312.84 34LF 12" LCPE @ 40.13% TO VAULT 12LF 12" LCPE @ -9.30% CB #3 12" IE 305.00 (W) RIM EL 309.41 LINEAR DRAIN 15.00% 4.40% 15.00% 4.21%15.00% 4.76% 15.00% 4.08% 15.0 0 % 5.63% 11.90% 15.0 0 % 7.12% 1.50% 9.78% BLDG 1 BLDG 2 BLDG 3 LOT LINE (TYP)CL ALLEYBLDG 6 BLDG 7 EX.CB #6 12" IE 341.60 (E) 12" IE 341.59 (NW) RIM EL 345.08 EX.CB #13 12" IE 336.82 (SE) 12" IE 336.82 (W) RIM EL 340.48 43LF 12" LCPE @ 10.65% EX.CB #12 12" IE 332.19 (W) 12" IE 332.19 (E) RIM EL 335.01 EX.CB #11 12" IE 323.97 (E) 12" IE 323.97 (W) RIM EL 327.12 EX.CB #10 12" IE 315.99 (E) 12" IE 315.99 (W) RIM EL 319.95 87LF 12" LCPE @ 4 . 3 9 % EX.CB #9 12" IE 312.18 (E) 12" IE 312.18 (W) RIM EL 315.69 PVI STA: 1+67.58 PVI EL: 316.44 K: 1.89 BVC STA: 1+57.58EL: 314.94EVC STA: 1+77.58EL: 316.8820' VC PVI STA: 2+87.00 PVI EL: 324.45 K: 1.85 BVC STA: 2+77.00EL: 322.95EVC STA: 2+97.00EL: 324.8720' VC PVI STA: 3+92.96 PVI EL: 331.72 K: 1.95 BVC STA: 3+82.96EL: 330.22EVC STA: 4+02.96EL: 332.2020' VC PVI STA: 7+17.50 PVI EL: 330.70 K: 1.83 BVC STA: 7+07.50EL: 331.11EVC STA: 7+27.50EL: 329.2020' VC PVI STA: 8+33.11 PVI EL: 321.49 K: 3.19 BVC STA: 8+23.11EL: 322.05EVC STA: 8+43.11EL: 320.3020' VC PVI STA: 5+50.34 PVI EL: 348.28 K: 3.33 BVC STA: 5+00.34EL: 340.78EVC STA: 6+00.34EL: 340.78100' VC PVI STA: 0+40.64 PVI EL: 297.39 K: 3.83 BVC STA: 0+30.64EL: 296.42EVC STA: 0+50.64EL: 298.8920' VC PVI STA: 2+60.95 PVI EL: 320.54 K: 1.88 BVC STA: 2+50.98EL: 320.10EVC STA: 2+70.92EL: 322.0420' VC PVI STA: 3+66.96 PVI EL: 327.82 K: 1.85 BVC STA: 3+56.96EL: 327.40EVC STA: 3+76.96EL: 329.3220' VC PVI STA: 4+61.81 PVI EL: 335.00 K: 1.95 BVC STA: 4+51.81EL: 334.52EVC STA: 4+71.81EL: 336.5020' VC PVI STA: 6+48.87 PVI EL: 333.50 K: 1.83 BVC STA: 6+38.87EL: 335.00EVC STA: 6+58.87EL: 333.0920' VC PVI STA: 7+46.27 PVI EL: 326.38 K: 2.13 BVC STA: 7+36.27EL: 327.88EVC STA: 7+56.27EL: 325.8220' VC BVC STA: 8+51.99EX R.O.W.FACE OF EX CURB5' SW GRANT AVENUE S2' ROW DEDICATION 53LF 12" L C P E @ 9 . 0 9 % EX.SSMH #8 8" IE IN 306.30 (E) 8" IE OUT 306.20 (S) RIM EL 313.68 STA 1+50.07 EX.SSMH #9 8" IE OUT 326.75 (W) RIM EL 335.10 STA 4+64.14 EX.SSMH #6 8" IE IN 335.16 (E) 8" IE OUT 335.16 (S) RIM EL 345.05 STA 5+51.20 EX. SSMH #5 STA 5+91.45 8" IE IN 332.81 (N) 8" IE OUT 332.76 (SW) RIM EL 341.84 EX.SSMH #4 8" IE IN 328.75 (NE) 8" IE OUT 328.65 (W) RIM EL 336.56 STA 6+27.31 WATER 10" D.I. 82LF 1 2 " L C P E @ 1 4. 0 6 % EX.CB #8 12" IE 300.63 (E) 12" IE 300.63 (S) RIM EL 303.51 16LF 12" LCPE @ 2.25% 48LF 12" LCPE @ 3.02% 24LF 12" LCPE @ 50.38% TO VAULT EX.SFMH#1 12" IE 290.82 (S) 12" IE 288.52 (W) RIM EL 300.76 EX.CB #14 12" IE 288.17 (E) 12" IE 288.37 (SE) 12" IE 288.16 (W) RIM EL 297.71 EX SDMH-1 12" IE 286.71 (E) 12" IE 287.21 (SE) 12" IE 286.61 (W) 12" IE 290.01 (N) 12" IE 290.16 (NE) RIM EL 294.51 CB #4 12" IE 337.92 (NW) RIM EL 340.60 55LF 12" RCP @ 0.60% 106LF 12" LC P E @ 7 . 7 2 % 103LF 12" L C P E @ 7 . 7 4 %MATCH LINE STA. 8+75.00MATCH LINE STA. 8+75.00V: 1"=10' H: 1"=30' GRANT CIRCLE SE (PRIVATE ALLEY) V: 1"=10' H: 1"=30' LOT CENTER LINE PROFILE V: 1"=10' H: 1"=30' GRANT CIRCLE SE (PRIVATE ALLEY) IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 ROAD AND STORM PROFILESGRANT PLACE TOWNHOMESC4.1LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429010 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 STATIONS ARE AS PER GRANT CIRCLE SE CL PROFILE STATIONS ARE AS PER LOT CENTER LINE ALIGNMENT. SURFACE WATER UTILITY JFarah 09/03/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 N EXIST WALL PROPOSED KEYSTONE WALL PROPOSED GRASSCRETE PROPOSED GRASSCRETE SERVICE DRIVEWAY FOR STORM VAULT MAINTENANCE PROPOSED ASPHALT PAVEMENT PROPOSED CONCRETE SIDEWALK EX STORM DRAIN NOTE: STORM FACILITIES HAVE BEEN INSTALLED UNDER AN EXPIRED PERMIT AND REFLECT AS-BUILT CONDITIONS. NEW VAULT BUILDING PERMIT BY CITY OF RENTON WILL BE REQUIRED. EXISTING VAULT PROPOSED SIDEWALK PROPOSED ACCESS DRIVEWAY PROPOSED PARKING PROPOSED SIDEWALK PROPOSED KEYSTONE WALL EXIST CONTROL STRUCTURE IN VAULT - SEE DETAIL SHEET C4.3 GRATE WITH HATCH WATER QUALITY CONTROL STRUCTURE IN VAULT SEE DETAIL SHEET C4.3 4" PERF PVC SDR 35 FOOTING DRAIN 4" PERF PVC SDR 35 FOOTING DRAIN PROPOSED PARKING PROPOSED KEYSTONE WALL B C4.3 AC4.3MIN.12" OUTLET PIPE IE=295.57 AB 6"8" SHEAR GATE PIPE SUPPORT: 3" X .090" ALUMINUM W/ 58" STAINLESS BOLTS FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. 100-YEAR WATER SURFACE DESIGN EL.=299.02 0.010' W x 1.9' H NOTCH 18" RISER IE=290.87 AB RESTRICTOR PLATE WITH ORIFICE ELEV=289.87 DRILL A 0.90" HOLE IN PLATE WELDED TO FLANGE OR DRILLED TO CAP PIPE SUPPORTS (2 MIN): 3" X .090" ALUMINUM W/ 58" STAINLESS BOLTS 5'x10' GRATED LOCKING REMOVABLE ACCESS PANEL (MARKED DRAIN) RIM=302.91 SOLID FLANGE OR CAP ELEV=293.57 BQWS DESIGN EL.=286.10 WATER QUALITY EL.=290.87 AB8.15' LIVE STORAGE4.77' DEAD STORAGEPROPOSED 4" PERF PVC FOOTING DRAIN EXIST PERF PVC DRAIN EXIST PERF PVC DRAIN IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 VAULT PLAN AND DETAILSGRANT PLACE TOWNHOMESC4.2LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429011 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 STEEL PROTECTION CAGE 14' PROPOSED RAILING EXIST COUPLING COUPLING NOTE: CONTROL STRUCTURES SHOP DRAWINGS AS SUBJECT FOR APPROVAL BY THE ENGINEER OF RECORD PRIOR TO THE MANUFACTURING AND INSTALLATION. 5'x10' GRATED LOCKING REMOVABLE ACCESS PANEL (MARKED DRAIN) RIM=302.91 FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. 100-YEAR WATER SURFACE DESIGN EL.=299.02 8" SHEAR GATE 18" RISER 12" OUTLET PIPE EXIST WATER QUALITY EL.=290.87 AB4.00' , 2ND ORIFICEELBOW WITH ORIFICE ELEV=294.87 DRILL A 0.98" HOLE IN PLATE WELDED TO FLANGE OR DRILLED TO CAP STORMFILTER MANHOLE SEE DET. ON SHEET C4.1 AS PER SURVEY DATED 03/05/24 AS PER SURVEY DATED 03/05/24 SOLID FLANGE OR CAP ELEV=299.52 VAULT ACCESS 5'x10' GRATE SEE C4.3 VAULT ACCESS 5'x10' GRATE SEE C4.3 CC4.3 DEVELOPMENT ENGINEERING NJanders 09/16/2024 GRASSCRETE ACCESS 8.15' LIVE STORAGE 4.77' DEAD STORAGE (AVERAGE) 0.7' SEDIMENT STORAGE (VARIES) 0.67' FREEBOARD 100-YEAR WATER SURFACE DESIGN EL.=299.02 AS-BUILD WATER QUALITY DESIGN EL.=290.87 SEDIMENT STORAGE DESIGN EL.=286.10 VAULT ACCESS 8 5'x10' GRATED LOCKING REMOVABLE ACCESS PANEL AB RIM=302.91 TOP OF VAULT EL.=300.73 (AVERAGE) 34LF 12" TO CB #14 IE.=290.87 IE.=295.57 28LF 12" TO STORMFILTER MANHOLE FINISHED GRADE TRIM OR STEPPING TOP ROW OF GEOFOAM BLOCKS TO MATCH FINISHED GRADE SLOPE CONTROL STRUCTURE IE.= 288.98 34LF 12" FROM CB #1 VAULT ACCESS 3 24"Ø SOLID LOCKING LID W/ FRAME (TYP) (MARKED DRAIN) AB RIM=306.99 VAULT ACCESS 4 24"Ø SOLID LOCKING LID W/ FRAME (TYP) (MARKED DRAIN) AB RIM=304.18 PROPOSED RIM=306.46 5' WATER QUALITY CONTROL STRUCTURE W/ SOLID TOP ELEV=288.50 MAX. DEPTH FROM FINISHED GRADE TO VAULT SHALL BE 20 FEET AT ACCESS POINTS EXISTING GRADE FINISHED GRADE GEOFOAM BLOCKS EPS46 OR EQUAL 5'x7' OPENING 4" PERF. PVC SDR35 FOOTING DRAIN @ S= 0.5% MIN. (TYP.) 6" MIN. GRAVEL AROUND FOOTING DRAIN (TYP.) SHEET DRAIN (TYP.) FINISHED GRADE RAIL FENCE H=42" KEYSTONE RET. WALL REQUIRED VOLUME 29,359 CF PROVIDED VOLUME 29,960 CF REQUIRED VOLUME 8,856 CF PROVIDED VOLUME 17,535 CF TOP OF VAULT EL.=300.73 20.0'20.0' EXISTING GRADE FINISHED GRADE VAULT ACCESS 4 24"Ø SOLID LOCKING LID W/ FRAME (TYP) (MARKED DRAIN) AB RIM=304.18 PROPOSED RIM=306.14 VAULT ACCESS 5 24"Ø SOLID LOCKING LID W/ FRAME (TYP) (MARKED DRAIN) AB RIM=304.90 PROPOSED RIM=307.16 4" PERF. PVC 4" PERF. PVC GEOFOAM BLOCKS EPS46 OR EQUAL EXIST WALL 4" PERF. PVC SDR35 FOOTING DRAIN @ S= 0.5% MIN. (TYP.) SHEET DRAIN (TYP.) 8.15' LIVE STORAGE 4.77' DEAD STORAGE (AVERAGE) 100-YEAR WATER SURFACE DESIGN EL.=299.02 AS-BUILD WATER QUALITY DESIGN EL.=290.87 SEDIMENT STORAGE DESIGN EL.=286.10 6" MIN. GRAVEL AROUND FOOTING DRAIN (TYP.) 0.67' FREEBOARD WATER SURFACE DESIGN EL.=358.4 TOP OF VAULT EL.=300.73 4" PERF. PVC @ S=0.0050 4" PVC VERT. PIPE 6" MIN. GRAVEL BASE GEOFOAM BLOCKS EPS46 OR EQUAL 1' MIN NATIVE SOIL BACKFILL 4" C.O. W/ VALVE BOX FRAME & COVER & CONC. PAD 4" MIN.GRASSCRETE PAVERS 2" MIN. CHOKER COURSE (3/4" CRUSHED STONE) ON 6" MIN. CRUSHED SURFACE BASE (3/4" TO 1-1/2" CRUSHED STONE) WATER SURFACE DESIGN EL.=358.4 TOP OF VAULT EL.=300.73 (AVERAGE) 6" MIN. GRAVEL BASE GEOFOAM BLOCKS EPS46 OR EQUAL 1' MIN NATIVE SOIL BACKFILL FILTER FABRIC ON TOP AND AROUND SIDES OF GEOFOAM BLOCKS 4" PERF. PVC FILTER FABRIC 4" MIN.GRASSCRETE PAVERS 2" MIN. CHOKER COURSE (3/4" CRUSHED STONE) ON 6" MIN. CRUSHED SURFACE BASE (3/4" TO 1-1/2" CRUSHED STONE) GRAVEL VAULT ACCESS 2 5'X10' GRATED LOCKING REMOVABLE ACCESS PANEL AB RIM=308.09 ELEV=288.50 MAX. DEPTH FROM FINISHED GRADE TO VAULT SHALL BE 20 FEET AT ACCESS POINTS GEOFOAM BLOCKS EPS46 OR EQUAL FINISHED GRADE 1"=5' DETENTION VAULT SECTION B-B 1"=5' DETENTION VAULT SECTION A-A 1"=5' GEOFOAM DETAIL SECTION A-A 1"=5' GEOFOAM DETAIL SECTION B-B IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 VAULT DETAILSGRANT PLACE TOWNHOMESC4.3LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429012 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 1"=5' DETENTION VAULT SECTION C-C DEVELOPMENT ENGINEERING NJanders 09/16/2024 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 STORMFILTER DETAILSGRANT PLACE TOWNHOMESC4.4LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429013 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 SFMH#1 (W) 288.59 LCPE 12" (S) 290.82 LCPE 12" 300.59 0.0167 CFS 7 PSC 18" 0.0266 CFS 0.1153 CFS ZPG 2 12"6" DEVELOPMENT ENGINEERING NJanders 09/16/2024 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC4.5LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429014 PR23-000126DEVELOPMENT ENGINEERING NJanders 09/16/2024 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC4.6LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429015 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. TOPOGRAPHY, BOUNDARY, AND UTILITIES STATEMENT: FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 DETAILSGRANT PLACE TOWNHOMESC4.7LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429016 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 EX. CB #1 EX.CB #6 EX.CB #7 EX.CB #8 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 EL 306.95 EL 345.08 EL 354.82 EL 303.51 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 12" (N) LCPE IE=302.54 12" (NW) LCPE IE=341.60 12" (E) LCPE IE=341.60 12" (W) LCPE IE=349.02 12" (E) LCPE IE=300.63 12" (S) LCPE IE=300.63 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 10.824L 5+45.00 14.654L 1+18.16 0.970L 0+82.63 9.047L EXIST STORM DRAINAGE STRUCTURE TABLE ID SDCB-T1 SDMH-T2.1 SDMH-T2.2 DESCRIPTION CB-TYPE 1 SDMH TYPE 2 SDMH TYPE 2 RIM ELEV EL 307.41 EL 307.91 EL 305.30 PIPE INVERT 12" (SW) EX CMP IE=303.06 12" (NE) RCP IE=303.24 12" (NW) EX CMP IE=302.95 12" (NE) EX CMP IE=302.95 12" (SW) RCP IE=303.63 STATION OFFSET 10+24.68 32.114L 10+46.92 33.577L 9+89.49 28.654L DRAIN 1ST FF= 316.73 2ND FF= 326.08 1ST FF= 317.77 2ND FF= 328.08 1ST FF= 318.35 2ND FF= 328.08 1ST FF= 318.91 2ND FF= 328.08 1ST FF= 320.0 2ND FF= 330.08 1ST FF= 322.61 2ND FF= 331.85 1ST FF= 324.61 2ND FF= 333.77 1ST FF= 331.59 2ND FF= 341.57 1ST FF= 330.35 2ND FF= 340.19 1ST FF= 325.70 2ND FF= 335.27 1ST FF= 325.95 2ND FF= 335.27 1ST FF= 327.35 2ND FF= 336.77 1ST FF= 323.80 2ND FF= 333.95 1ST FF= 324.02 2ND FF= 333.95 1ST FF= 325.81 2ND FF= 337.00 1ST FF= 333.31 2ND FF= 343.03 1ST FF= 333.44 2ND FF= 343.03 1ST FF= 334.94 2ND FF= 344.56 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 331.80 2ND FF= 341.55 1ST FF= 333.47 2ND FF= 343.08 1ST FF= 348.19 2ND FF= 357.98 1ST FF= 349.75 2ND FF= 359.52 1ST FF= 351.13 2ND FF= 361.03 1ST FF= 352.61 2ND FF= 362.52 1ST FF= 354.23 2ND FF= 364.01 1ST FF= 348.25 2ND FF= 357.99 1ST FF= 349.53 2ND FF= 359.48 1ST FF= 350.87 2ND FF= 360.98 1ST FF= 352.46 2ND FF= 362.52 1ST FF= 353.96 2ND FF= 364.01 1ST FF= 314.90 2ND FF= 324.73 1ST FF= 315.92 2ND FF= 325.92 1ST FF= 316.10 2ND FF= 325.92 1ST FF= 316.60 2ND FF= 325.92 1ST FF= 317.57 2ND FF= 327.57 BUILDING #2 BUILDING #3 BUILDING #4 BUILDING #5 BUILDING #6BUILDING #7 BUILDING #8 BUILDING #1 EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 EX. CB #1 EX.CB #6 EX.CB #7 EX.CB #8 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE I GRATE RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 EL 306.95 EL 345.08 EL 354.82 EL 303.51 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 12" (N) LCPE IE=302.54 12" (NW) LCPE IE=341.60 12" (E) LCPE IE=341.60 12" (W) LCPE IE=349.02 12" (E) LCPE IE=300.63 12" (S) LCPE IE=300.63 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 10.824L 5+45.00 14.654L 1+18.16 0.970L 0+82.63 9.047L EXIST STORM DRAINAGE STRUCTURE TABLE ID SDCB-T1 SDMH-T2.1 SDMH-T2.2 DESCRIPTION CB-TYPE 1 SDMH TYPE 2 SDMH TYPE 2 RIM ELEV EL 307.41 EL 307.91 EL 305.30 PIPE INVERT 12" (SW) EX CMP IE=303.06 12" (NE) RCP IE=303.24 12" (NW) EX CMP IE=302.95 12" (NE) EX CMP IE=302.95 12" (SW) RCP IE=303.63 STATION OFFSET 10+24.68 32.114L 10+46.92 33.577L 9+89.49 28.654L GRANT CIRCLE S.E. (PRIVATE ALLEY) S-0463 GRANT CIRCLE S.E. (PRIVATE ALLEY) 1+26.06, 0.00' T TOP=307.17 IE IN 304.90 (NE) IE OUT 304.80 (SE) SSMH #2, 48"126LF 8 " PVC C90 0 @ 1 .2 3% 67LF 8" P V C C 9 0 0 @ 0. 5 0 % 1.5' ROW DEDICATION 1+92.52, 0.54' LT TOP=312.84 IE IN 305.28 (N) IE IN 305.28 (E) IE OUT 305.23 (SW) EX.SSMH #3, 48" 5+26.39, 1.13' LT TOP=336.56 IE IN 328.75 (NE) IE OUT 328.65 (W) EX.SSMH #4 , 48" 5+68.51, 1.16' LT TOP=341.84 IE IN 332.81 (N) IE OUT 332.76 (SW) EX. SSMH #5, 48" 7+09.41, 0.46' RT TOP=354.13 IE OUT 343.49 (W) EX.SSMH #7, 48" 5+51.20, 13.30' LT TOP=345.05 IE IN 335.16 (E) IE OUT 335.16 (S) EX.SSMH #6, 48" 4+39.48, 0.00' T TOP=335.10 IE OUT 326.75 (W) EX.SSMH #9, 48" 1+25.41, 0.00' T TOP=313.68 IE IN 306.30 (E) IE OUT 306.20 (S) EX.SSMH #8, 48" 5' EX. 96LF 8" PVC @ 8.64%EX. 43LF 8" PVC @ 5.46%EX. 42LF 8" PVC @ 9.52% EX. 333LF 8" PVC @ 7.02%EX. 125LF 8" PVC @ 0.74%EX. 314LF 8" PVC @ 6.51% 3.8'3.0' 5' 0+00.00, 0.00' LT TOP=310.57 IE IN 303.05 (NE) IE IN 303.25 (NW) IE OUT 303.05 SW POTHOLED 12/29/22 DEPTH TO TOP = -6.25FT SSMH #1, 48" IE 306.62 POC RIM=314.69 IE 309.72 POC RIM=316.25 IE 312.57 POC RIM=319.15 IE 308.26 POC RIM=315.68 IE 310.90 POC RIM=317.04 IE 315.24 POC RIM=322.61 IE 319.33 POC RIM=325.88 IE 322.52 POC RIM=330.62 IE 325.00 POC RIM=331.81 IE 326.05 POC RIM=334.88 IE 324.24 POC RIM=333.56 IE 323.68 POC RIM=333.15 IE 322.13 POC RIM=331.81 IE 319.22 POC RIM=327.30 IE 317.06 POC RIM=325.91 IE 310.49 POC RIM=318.73IE 308.90 POC RIM=317.78 IE 307.62 POC RIM=316.74 IE 317.27 POC RIM=326.05 IE 315.45 POC RIM=324.71 IE 312.31 POC RIM=320.04 IE 310.85 POC RIM=319.01 IE 317.48 POC RIM=324.40 IE 317.14 POC RIM=324.12 IE 323.96 POC RIM=331.80 IE 326.66 POC RIM=333.44 IE 337.07 POC RIM=347.91 IE 337.06 POC RIM=348.21 IE 339.49 POC RIM=349.98 IE 340.07 POC RIM=350.92 IE 341.80 POC RIM=352.57 IE 343.38 POC RIM=354.22 IE 343.31 POC RIM=354.01 IE 341.75 POC RIM=352.57 IE 339.99 POC RIM=350.86 IE 339.25 POC RIM=349.73 MIN 3' NOTES: ·FOR SEWER RIMS AND INVERTS SEE PROFILE ON SHEET C5.1 ·FOR STANDARD SEWER MATERIALS AND DETAILS SEE CITY OF RENTON STANDARD DETAIL PLANS. ·18" MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN AND SEWER MAIN OR SIDE. ·ALL SEWER MAIN AND MANHOLES PROVIDED BY THE PROJECT ARE PUBLIC. SIDE SEWER AND STUBS ARE PRIVATE. ·ALL SEWER MAINS TO BE MINIMUM 8 INCH PVC. ·ALL UTILITIES SERVING THE SITE SHALL BE UNDERGROUND. ·A 15' SEWER UTILITY EASEMENT IS REQUIRED, EASEMENT SHALL BE CENTERED OF THE SEWER MAIN AND TO BE PROVIDED AS A PART OF THE FINAL PLAT. CONTRACTOR SHALL POTHOLE AND FIELD VERIFY VERTICAL AND HORIZONTAL LOCATION OF EXISTING HIGH PRESSURE GAS LINE BEFORE INSTALLATION OF ALL NEW UTILITIES IN GRANT AVENUE SOUTH TO ASSURE THAT MINIMUM VERTICAL AND HORIZONTAL SEPARATION CAN BE MAINTAINED. CONTRACTOR SHALL NOTIFY ENGINEER IF SEPARATION CANNOT BE MAINTAINED IN ORDER TO DEVELOP ALTERNATE DESIGN. CHECK ACTUAL SEPARATION IN FIELD. PROPOSED LEGEND GRASSCRETE ACCESS ASPHALT PAVEMENT CONCRETE PAVEMENT PROPERTY BOUNDARY EASEMENT LINE ROW DEDICATION PROPOSED SEWER MANHOLE PROPOSED SEWER MAIN ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WWP-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 SANITARY SEWER PLANGRANT PLACE TOWNHOMESC5.0LUA23-000283C23006099GRANT PLACE TOWNHOMESS-429001 PR23-000126N SEE SEPARATION NOTES ON SHEET C4.0 SEE SEPARATION NOTES ON SHEET C4.0 15' SEWER EASEMENT CHECK ACTUAL SEPARATION IN FIELD NOTE: THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS-BUILT CONDITIONS. ADDITIONAL AS-BUILT SURVEY REQIRED TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER. PROPOSED IE AND RIM ELEVATION TAKES PRECEDENCE OVER SURVEY DATA. WASTEWATER UTILITY jstowell 09/12/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 SSMH #1 8" IE IN 303.05 (NE) 8" IE IN 303.25 (NW) 8" IE OUT 303.05 (SW) RIM EL 310.57 STA -0+00.00 1.60'2.26'0.52'EX EX NEW EX 12" SD ADD ETHNOFOAM PAD FOR SEPARATION WITH SEWER EX ROAD GRADE 126LF 8" PVC C900 @ 1.23% IN GRANT AVE S CONDO DRIVEWAY ENTRANCE 90° ANGLES PLEX CURB SEWER SIDE IE STA: 7+09.42 ELEV: 343.38 SEWER SIDE IE STA: 7+08.77 ELEV: 343.31 SEWER SIDE IE STA: 6+90.93 ELEV: 341.89 SEWER SIDE IE STA: 6+89.95 ELEV: 341.81SEWER SIDE IE STA: 6+70.15 ELEV: 340.10 SEWER SIDE IE STA: 6+69.45 ELEV: 340.04 SEWER SIDE IE STA: 6+33.76 ELEV: 336.95 SEWER SIDE IE STA: 6+35.47 ELEV: 337.10 SEWER SIDE IE STA: 6+61.58 ELEV: 339.36 SEWER SIDE IE STA: 6+62.59 ELEV: 339.45 SEWER SIDE IE STA: 4+71.55 ELEV: 324.81 SEWER SIDE IE STA: 4+57.09 ELEV: 323.80 SEWER SIDE IE STA: 4+36.30 ELEV: 322.35 SEWER SIDE IE STA: 3+91.86 ELEV: 319.23 SEWER SIDE IE STA: 3+65.32 ELEV: 317.39 SEWER SIDE IE STA: 3+60.36 ELEV: 317.04 SEWER SIDE IE STA: 3+33.34 ELEV: 315.14 SEWER SIDE IE STA: 2+95.62 ELEV: 312.51 SEWER SIDE IE STA: 2+71.72 ELEV: 310.83 SEWER SIDE IE STA: 2+55.18 ELEV: 309.67 SEWER SIDE IE STA: 2+10.57 ELEV: 306.55 SEWER SIDE IE STA: 2+33.62 ELEV: 308.16 SEWER SIDE IE STA: 4+95.33 ELEV: 326.482.31'96LF 8" PV C @ 8 . 6 4 % SSMH #2 8" IE IN 304.90 (NE) 8" IE OUT 304.79 (SE) RIM EL 307.17 STA 1+26.06 67LF 8" PVC C900 @ 0.50% 43LF 8" PVC @ 5 . 4 6 % 42LF 8" PV C @ 9 . 5 2 % SEWER EASEMENT PARCEL #3260600000 PLE PLEX.SSMH #3 8" IE IN 305.28 (N) 8" IE IN 305.28 (E) 8" IE OUT 305.23 (SW) RIM EL 312.84 STA 1+92.52 EX.SSMH #4 8" IE IN 328.75 (NE) 8" IE OUT 328.65 (W) RIM EL 336.56 STA 5+26.39 EX. SSMH #5 STA 5+68.51 8" IE IN 332.81 (N) 8" IE OUT 332.76 (SW) RIM EL 341.84 EX.SSMH #6 STA 6+13.01 8" IE IN 335.16 (E) 8" IE OUT 335.16 (S) RIM EL 345.05 EX.SSMH #7 8" IE OUT 343.49 (W) RIM EL 354.13 STA 7+09.412.44'2.10'BLDG 4 & 5 LOT LINE (TYP)BLDG 6 BLDG 7 BLDG 8 EX.CB #7 12" IE 349.02 (W) RIM EL 354.82 EX.CB #6 12" IE 341.60 (E) 12" IE 341.59 (NW) RIM EL 345.08 CB #2 12" IE 303.89 (W) 12" IE 303.89 (E) 12" IE 303.89 (N) RIM EL 307.56 WATER 10" D.I. GAS PIPE CROSSING STA: 1+74.72 1.90'333LF 8" PVC @ 7 . 0 2 %2.14'1.96'1.83'1.64'1.48'1.41'1.69'1.75'2.02'2.24'2.31'2.36'2.37'2.29'2.47'2.50'ADD ETHNOFOAM PAD FOR SEPARATION WITH WATER SIDE SEWER IE STA: 1+47.48 ELEV: 307.74 SIDE SEWER IE STA: 1+67.10 ELEV: 309.02 SIDE SEWER IE STA: 1+91.97 ELEV: 310.64 SIDE SEWER IE STA: 1+97.44 ELEV: 310.99 SIDE SEWER IE STA: 2+67.89 ELEV: 315.58 SIDE SEWER IE STA: 2+92.91 ELEV: 317.21 SIDE SEWER IE STA: 2+96.20 ELEV: 317.43 SIDE SEWER IE STA: 3+25.62 ELEV: 319.34 SIDE SEWER IE STA: 2+19.93 ELEV: 312.46 SIDE SEWER IE STA: 3+70.18 ELEV: 322.23 SIDE SEWER IE STA: 3+94.17 ELEV: 323.80 SIDE SEWER IE STA: 4+30.84 ELEV: 326.18 EX. STORM CP STA: 0+55.90 ELEV: 302.90 EX. SEWER IE STA: 0+56.09 ELEV: 305.69 SIDE SEWER IE STA: 4+02.65 ELEV: 324.35 125LF 8" PVC @ 0.74% EX.SSMH #3 8" IE IN 305.28 (N) 8" IE IN 305.28 (E) 8" IE OUT 305.23 (SW) RIM EL 312.84 STA 0+00.53 EX.SSMH #9 STA 4+39.48 8" IE OUT 326.75 (W) RIM EL 335.10 EX.SSMH #8 8" IE IN 306.30 (E) 8" IE OUT 306.20 (S) RIM EL 313.68 STA 1+25.41 STAIRS 90° ANGLEBACK OFSIDEWALKBACK OFSIDEWALKBLDG 1 BLDG 2 BLDG 3 3.56'2.44'4.40'WATER 10" D.I. EX.CB #9 12" IE 312.18 (E) 12" IE 312.18 (W) RIM EL 315.69 EX.CB #10 12" IE 315.99 (E) 12" IE 315.99 (W) RIM EL 319.95 EX.CB #11 12" IE 323.97 (E) 12" IE 323.97 (W) RIM EL 327.12 EX.CB #12 12" IE 332.19 (W) 12" IE 332.19 (E) RIM EL 335.01 EX. SEWER CP STA: 0+10.90 ELEV: 305.99 EX. WATER IE STA: 0+10.90 ELEV: 308.35 314LF 8" PVC @ 6 . 5 1 %3.24'2.87'2.78'3.33'2.67'3.03'3.16'3.63'3.90'4.02'4.43'- SSMH #1, 3, 4, 5, 6, 7, 8, 9 AND 10 PER C.O.R. STD. DTL. 400.1 - SSMH #2 PER C.O.R. STD. DTL. 400.2 - ALL MANHOLE FRAMES AND COVERS PER C.O.R. STD. DTL. 403.1 - ALL SEWER PIPES ARE PVC SDR35 - STATIONS ARE AS PER PIPE LENGTH 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 V: 1"=10' H: 1"=30' GRANT CIRCLE SE (SOUTH SIDE) IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WWP-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 SEWER PROFILESGRANT PLACE TOWNHOMESC5.1LUA23-000283C23006099GRANT PLACE TOWNHOMESS-429002 PR23-000126V: 1"=10' H: 1"=30' GRANT CIRCLE SE (NORTH SIDE) WASTEWATER UTILITY jstowell 09/12/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WWP-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 SANITARY SEWER DETAILSGRANT PLACE TOWNHOMESC5.2LUA23-000283C23006099GRANT PLACE TOWNHOMESS-429003 PR23-000126WASTEWATER UTILITY jstowell 09/12/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WWP-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 SANITARY SEWER DETAILSGRANT PLACE TOWNHOMESC5.3LUA23-000283C23006099GRANT PLACE TOWNHOMESS-429004 PR23-000126WASTEWATER UTILITY jstowell 09/12/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 EXIST STORM DRAINAGE STRUCTURE TABLE ID CB #2 CB #3 CB #4 EX SDMH-1 EX. CB #1 EX.CB #6 EX.CB #7 DESCRIPTION TYPE I GRATE TYPE I GRATE TYPE I GRATE TYPE II-SOLID LID TYPE I GRATE TYPE I GRATE TYPE I GRATE RIM ELEV EL 307.56 EL 309.41 EL 340.60 EL 294.51 EL 306.95 EL 345.08 EL 354.82 PIPE INVERT 12" (W) LCPE IE=303.89 12" (E) LCPE IE=303.89 12" (N) IE=303.89 12" (W) LCPE IE=305.00 12" (NW) RCP IE=337.92 12" (E) LCPE IE=286.71 12" (W) REINFORCED CONCRETE IE=286.61 12" (N) EX CMP IE=290.01 12" (NE) EX CMP IE=290.16 12" (SE) EX CMP IE=287.21 12" (E) LCPE IE=302.54 12" (N) LCPE IE=302.54 12" (NW) LCPE IE=341.60 12" (E) LCPE IE=341.60 12" (W) LCPE IE=349.02 12" (E) LCPE IE=300.63 STATION OFFSET 9+92.54 8.764L 9+80.14 8.685L 6+00.30 10.703L 3+14.80 5.016L 10+09.06 10.824L 5+45.00 14.654L 1+18.16 0.970L 0+82.63 EXIST STORM DRAINAGE STRUCTURE TABLE ID SDCB-T1 SDMH-T2.1 SDMH-T2.2 DESCRIPTION CB-TYPE 1 SDMH TYPE 2 SDMH TYPE 2 RIM ELEV EL 307.41 EL 307.91 EL 305.30 PIPE INVERT 12" (SW) EX CMP IE=303.06 12" (NE) RCP IE=303.24 12" (NW) EX CMP IE=302.95 12" (NE) EX CMP IE=302.95 12" (SW) RCP IE=303.63 STATION OFFSET 10+24.68 32.114L 10+46.92 33.577L 9+89.49 28.654L DRAIN GRANT CIRCLE S.E. (PRIVATE ALLEY) GRANT CIRCLE S.E. (PRIVATE ALLEY) RAISE EX. FIRE HYDRANT 1.54' EX. 12" WATER MAIN EX. 10" WATER SUPPLY EX. 10" WATER SUPPLY EX. 10" WATER SUPPLY PRIVATE ALLEY 4 - 1" WATER SERVICE 4 - 1" WATER METER PER 320.10 4 - 1" WATER SERVICE 4 - 1" WATER METER PER 320.10 4 - 1" WATER SERVICE 4 - 1" WATER METER PER 320.10 4 - 1" WATER SERVICE 4 - 1" WATER METER PER 320.10 5 - 1" WATER SERVICE 5 - 1" WATER METER PER 320.10 5 - 1" WATER SERVICE 5 - 1" WATER METER PER 320.10 5 - 1" WATER SERVICE 5 - 1" WATER METER PER 320.10 5 - 1" WATER SERVICE 5 - 1" WATER METER PER 320.10 EX. FIRE HYDRANT EX. FIRE HYDRANT EX. FIRE HYDRANT EX. FIRE HYDRANT EX. FIRE HYDRANT EX. FIRE HYDRANT PROVIDE ASPHALT BUMP OUTS FOR THE MAINTENANCE ACCESS OVER VALVES AT THE CONCRETE SIDEWALK SEE DETAIL ON C6.0 PROVIDE ASPHALT BUMP OUTS FOR THE MAINTENANCE ACCESS OVER VALVES AT THE CONCRETE SIDEWALK SEE DETAIL ON C6.0 PROVIDE ASPHALT BUMP OUTS FOR THE MAINTENANCE ACCESS OVER VALVES AT THE CONCRETE SIDEWALK SEE DETAIL ON C6.0 HOUSING FOR THE TREE METERS SEE SHEET 6.3 EX. BLOWOUT VALVE AS PER STD. DET. 340.10 (WATER MAIN HIGH POINT) ALIGNMENT: ACCESS END STA: 1+15.83 OFFSET: 12.934LTEX 76L F, 1 0" DI C L 5 2 EX 28LF, 10 " D I C L 5 2 EX 159LF, 10" DI CL52 EX 104LF, 10" DI CL52 EX 107LF, 10" DI CL52 E X 3 9 L F , 1 0 " D I C L 5 2 EX 27LF, 10" DI CL52EX 119LF, 10" DI CL52 EX 51LF, 10" DI CL52EX 26LF, 10" DI CL52EX 101LF, 10" DI CL52EX 121LF, 10" DI CL52EX 116LF, 10" DI CL52 EX 37LF, 10" DI CL52 EX 57L F , 1 0 " DI C L 5 2 FIRE HYD. CONN. AS PER 310.10 STA: 2+62.16 OFFSET: 0.787RT FIRE HYD. CONN. AS PER 310.10 STA: 3+65.70 OFFSET: 0.826RT FIRE HYD. CONN. AS PER 310.10 STA: 5+41.74 OFFSET: 0.008LT FIRE HYD. CONN. AS PER 310.10 STA: 7+16.14 OFFSET: 0.000T FIRE HYD. CONN. AS PER 310.10 STA: 8+37.33 OFFSET: 0.009LT FIRE HYD. CONN. AS PER 310.10 STA: 9+52.88 OFFSET: 0.064RT BEND AS PER 330.10 STA: 1+03.41 OFFSET: 0.000T BEND AS PER 330.10 STA: 4+72.80 OFFSET: 0.000T BEND AS PER 330.10 STA: 5+11.43 OFFSET: 0.000T BEND AS PER 330.10 STA: 5+19.28 OFFSET: 0.022RT EX. CAP ALIGNMENT: ACCESS END STA: 1+11.84 OFFSET: 5.886LT BEND AS PER 330.10 STA: 5+89.07 OFFSET: 0.000T BEND AS PER 330.10 STA: 6+15.10 OFFSET: 0.000T BEND AS PER 330.10 STA: 6+25.67 OFFSET: 0.000T EX.1.5" IRRIGATION METER WITH DCVA, AS PER 340.80 BEND AS PER 330.10 STA: 9+89.73 OFFSET: 0.000RT EX. 10" CONNECTION TO EX. 12" WATER MAIN ALIGNMENT: Grant Ave STA: 4+77.96 OFFSET: 15.200RT EX. 10" CONNECTION TO EX. 12" WATER MAIN ALIGNMENT: Grant Ave STA: 3+58.70 OFFSET: 2.727RT 10" GATE VALVE STA: 2+65.42 OFFSET: 0.800RT 10" GATE VALVE STA: 8+34.11 OFFSET: 0.024LT 10" GATE VALVE STA: 5+48.00 OFFSET: 0.000T 10" TEE 10" GATE VALVE STA: 5+38.45 OFFSET: 0.000T 10" GATE VALVE ALIGNMENT: ACCESS END STA: -0+03.51 OFFSET: 5.608LT 15.0'15.0'15.0'15 . 0 '15.0'15' PUBLIC UTILITY WATER EASEMENTFIRE HYD. CONN. AS PER 310.10 STA: 0+75.54 OFFSET: 0.000T AIR-VAC INSTALL POLYPIG AS PER COR STD 300.7 STA: 0+24.40 OFFSET: 0.078LT INSTALL POLYPIG AS PER COR STD 300.7 STA: 10+07.54 OFFSET: 0.005RT NOTES ·ALL MECHANIC-JOINT FITTINGS SHALL HAVE RESTRAINT RETAINER-ISLANDS SUCH AS MEGALUG 1100 SERIES OR RO-MAC 600 SERIES ROMBIGRIP AND CONCRETE BLOCKING. ·18" MINIMUM VERTICAL SEPARATION BETWEEN WATER MAIN AND GAS MAIN. ·ALL UTILITIES SERVING THE SITE SHALL BE UNDERGROUND. ·A DCVA IS REQUIRED DOWNSTREAM OF THE DOMESTIC WATER METER TO EACH BUILDING. THE DCVA WILL BE INSTALLED IN THE GARAGE AND IT MUST BE INSTALLED ON THE BUILDING WATER SUPPLY LINE BEFORE THE FIRST WATER FIXTURE. ·A 15' PUBLIC UTILITY WATER EASEMENT IS REQUIRED TO BE PROVIDED. EASEMENT SHALL BE CENTERED OVER THE WATER SYSTEM AND INCLUDE ALL MAINS, HYDRANTS, WATER METERS AND BLOW OFF ASSEMBLIES. ·WATER MAIN TO BE SHUT-OFF (BY CITY FORCES) PRIOR TO THE REMOVAL AND RE-INSTALLATION OF THE WATER SERVICES (BY DEVELOPER). PRESSURE AND PURITY TESTING OF THE WATER MAIN REQUIRED. ·ALL 1" WATER SERVICE LINES AND WATER SETTERS THAT DO NOT CURRENTLY COMPLY WITH STD. PLAN 320.1 SHALL BE REMOVED AND RE-INSTALLED PER THE STANDARD PLAN. ·ALL WATER METER SETTERS THAT CANNOT BE RAISED TO FINISH GRADE SHALL BE REMOVE AND REPLACED SUCH THAT SETTER COMPLIES WITH COVER REQUIREMENT AS PER STD. PLAN 320.1. ·WATER MAIN SHALL HAVE 3 FEET OF COVER. POTHOLE ALL WATER SERVICES AT EX. WATER MAIN TO CONFIRM 3 FEET OF COVER. IF COVER IS NOT MET, REPLACEMENT OF WATER MAIN IS REQUIRED AT LOCATIONS THAT DO NOT SATISFY REQUIREMENT. ENGINEER OF RECORD SHALL PROVIDE CONFIRMATION TO THE CITY'S PROJECT MANAGER. CONTRACTOR SHALL POTHOLE AND FIELD VERIFY VERTICAL AND HORIZONTAL LOCATION OF EXISTING HIGH PRESSURE GAS LINE BEFORE INSTALLATION OF ALL NEW UTILITIES IN GRANT AVENUE SOUTH TO ASSURE THAT MINIMUM VERTICAL AND HORIZONTAL SEPARATION CAN BE MAINTAINED. CONTRACTOR SHALL NOTIFY ENGINEER IF SEPARATION CANNOT BE MAINTAINED IN ORDER TO DEVELOP ALTERNATE DESIGN. WATER SERVICE WILL BE PROVIDED BY THE CITY OF RENTON. THE SITE IS IN THE ROLLING HILLS SERVICE AREA IN THE 490 HYDRAULIC PRESSURE ZONE. THERE IS AN EXISTING 12-INCH CITY WATER MAIN LOCATED IN GRANT AVENUE S THAT CAN DELIVER A MAXIMUM TOTAL FLOW CAPACITY OF 3,400 GALLONS PER MINUTE (GPM). THE APPROXIMATE STATIC WATER PRESSURE IS 77 PSI AT THE ELEVATION OF 310 FEET. THE SITE IS LOCATED OUTSIDE OF AN AQUIFER PROTECTION AREA. FIRE SERVICE AS PER HEARING EXAMINER DECISION BY CITY OF RENTON DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT (LUA23-000283, PP, SA, ECF, MOD, V-H) PROVIDED WATER SUPPLY SYSTEM CAN SUSTAIN PRESSURE AND FLOW CAPACITY FOR THE USE OF FIRE SPRINKLER. FIRE SERVICE CONNECTION CONNECTION IS PROVIDED TO EACH UNIT INDIVIDUALLY BY MEANS OF EXISTING 1" SIDE CONNECTION VIA 1" METER. NOTE: THE UTILITIES HAVE BEEN PARTIALLY UPDATED TO REFLECT AS-BUILT CONDITIONS. ADDITIONAL AS-BUILT SURVEY REQIRED TO OBTAIN INVERT ELEVATIONS ON STORM AND SANITARY SEWER. PROPOSED LEGEND GRASSCRETE ACCESS ASPHALT PAVEMENT CONCRETE PAVEMENT PROPERTY BOUNDARY EASEMENT LINE ROW DEDICATION EX WATER VALVE EX WATER MAIN NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WTR-24-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 WATER PLANGRANT PLACE TOWNHOMESC6.0LUA23-000283C23006099GRANT PLACE TOWNHOMESW-429001 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 VALVE COVER ASPHALT MAINTENANCE BUMP OUT CONCRETE SIDEWALK 60"10' NOTE: FILL AND COMPACT ROADWAY TO FINAL SUBGRADE BEFORE EXCAVATION FORINSTALLATION OF NEW WATER LINES. STATIONS ARE AS PER WATER MAIN PROFILE UNLESS STATED OTHERWISE. VALVE COVER ASPHALT MAINTENANCE BUMP OUT CONCRETE SIDEWALK 60"60" 10" MAIN VALVE 10" WATER MAIN 60"18.36'ASPHALT MAINTENANCE BUMP OUT CONCRETE SIDEWALK 10" WATER MAIN CONCRETE SIDEWALK FIRE SPLINKERS: FIRE SPLINKERS ARE REQUIRED TO BE INSTALLED ON BUILDINGS WITH 5 UNITS: BUILDING 1, 4, 5 AND 8 AS PER NFPA 13 AND IBC2021 NOTE: LOCATION AND ELEVATIONS FOR THE WATER MAIN ARE BASED ON POTHOLING AND AS-BUILT SURVEY note shut down of water main shall be sequenced and coordinated with the site inspector such that hydrants remain operational to provide fire protection for partially constructed structures. WATER UTILITY ABDOUL GAFOUR 09/13/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 6 LF 10" D.I.MIN. 3.00'EX R.O.W. 2' ROW DEDICATION TOP OF EX. 8" HIGH PRESSURE GAS PIPE STA: 0+25.13 CP: 290.66 TOP OF EX. 12" STORM PIPE STA: 0+10.29 CP: 291.41 COVER 3.11'CONNECT TO EX 12" WA 1-12"x10" CUT-IN TEE PER COR STD DTL 300.40 1-10" VALVE (FLxMJ) 2-10" 45° BEND (MJxMJ) WITH CONC BLOCK 1-2LF 10" SPOOL (MJxMJ) 2-12" GATES VALVES (FLxMJ) STA: 0+00.00 CP: 291.75 VERIFY FIELD CONDITIONS BLDG 6 BLDG 7BLDG 1 BLDG 2 BLDG 3 LOT LINE (TYP)MIN. 3.00'MIN. 3.00'MIN. 3.00'MIN. 3.00'GRANT AVENUE SALLEY159 LF 10" D.I. 104 LF 10" D.I. 107 LF 10" D.I. 39LF 10" D.I. 8 LF 10" D.I. 15 LF 10" D.I. 4 LF 10" D.I. 3 LF 10" D.I. 51 LF 10" D.I. 26 LF 10" D.I. 10 LF 10" D.I. 91 LF 10" D.I. 121 LF 10" D.I.EX.SSMH #4 8" IE IN 328.75 (NE) 8" IE OUT 328.65 (W) RIM EL 336.56 STA 6+27.31 EX. SSMH #5 8" IE IN 332.81 (N) 8" IE OUT 332.76 (SW) RIM EL 341.84 STA 5+91.45 EX.SSMH #6 8" IE IN 335.16 (E) 8" IE OUT 335.16 (S) RIM EL 345.05 STA 5+51.20 EX.CB #6 12" IE 341.60 (E) 12" IE 341.59 (NW) RIM EL 345.08 EX.SSMH #9 STA 4+64.14 8" IE OUT 326.75 (W) RIM EL 335.10 EX.CB #12 12" IE 332.19 (W) 12" IE 332.19 (E) RIM EL 335.01 EX.CB #11 12" IE 323.97 (E) 12" IE 323.97 (W) RIM EL 327.12 EX.CB #10 12" IE 315.99 (E) 12" IE 315.99 (W) RIM EL 319.95 EX.CB #9 12" IE 312.18 (E) 12" IE 312.18 (W) RIM EL 315.69 EX.SSMH #8 8" IE IN 306.30 (E) 8" IE OUT 306.20 (S) RIM EL 313.68 STA 1+50.07 EX.CB #8 12" IE 300.63 (E) 12" IE 300.63 (S) RIM EL 303.51 EX.SFMH#1 12" IE 290.82 (S) 12" IE 288.52 (W) RIM EL 300.76 EX.CB #14 12" IE 288.17 (E) 12" IE 288.37 (SE) 12" IE 288.16 (W) RIM EL 297.71 EX SDMH-1 12" IE 286.71 (E) 12" IE 287.21 (SE) 12" IE 286.61 (W) 12" IE 290.01 (N) 12" IE 290.16 (NE) RIM EL 294.51 1-10" 22.5° (MJxMJ) BEND WITH CONC BLOCK STA: 0+38.01 CP: 293.27 1-10"x6" F.H. ASSEMBLY STA: 0+75.54 CP: 299.17 1-10"x6" F.H. ASSEMBLY STA: 2+62.16 CP: 317.66 1-10"x6" F.H. ASSEMBLY STA: 3+65.70 CP: 324.89 1-10"x6" F.H. ASSEMBLY STA: 5+41.74 CP: 337.22 1-10"x6" F.H. ASSEMBLY STA: 7+16.14 CP: 324.93 1-10" VALVE (MJxMJ) STA: 5+47.96 CP: 338.17 1-10" VALVE (MJxMJ) 1-10" TEE (MJxMJ) WITH BLOCK STA: 5+38.45 CP: 337.22 1-10" 11.25° BEND (MJxMJ) STA: 6+25.67 CP: 331.47 1-10" 22.5° BEND (MJxMJ) STA: 6+15.10 CP: 333.16 1-10" 22.5° BEND (MJxMJ) STA: 5+89.07 CP: 335.65 1-10" 11.25° BEND (MJxMJ) WITH BLOCK STA: 5+18.91 CP: 337.22 1-10" 11.25° BEND (MJxMJ) WITH BLOCK STA: 5+11.43 CP: 337.22 1-10" 45° BEND (MJxMJ) WITH BLOCK STA: 4+72.80 CP: 333.44 1-10" 11.25° (MJxMJ) BEND WITH CONC BLOCK STA: 1+03.29 CP: 303.18 1-10" VALVE (MJxMJ) STA: 2+65.42 CP: 317.94 CB #4 12" IE 337.92 (NW) RIM EL 340.60 1.55'4.94'3.42'1.68'0.68'INSTALL 1" AIR-VAC RELEASE ASSEMBLY ON HIGH POINT OF WATER LINE PER RENTON STD PLAN 340.3 2.07'2.01'1.99'1.92'1.71'1.45'1.42'1.17'IN CASE VERTICAL SEPARATION IS LESS THAN 18" PROVIDE LAYER OF ETHOFOAM PROTECTION BETWEEN PIPES.4.13'3.70'3.42'2.59'3.29'MIN. 3.00'1.77'PROVIDE ETHOFOAM PAD AT SEWER SIDE AND WATER SERVICE 3.24'MIN. 3.00'RELOCATE EX. WATER MAIN 50 LF SECTION. SEE NOTES 3.20'1-10" 11.25° (MJxMJ) BEND WITH CONC BLOCK STA: 0+69.41 CP: 298.41 1-10" 11.25° (MJxMJ) BEND WITH CONC BLOCK STA: 0+56.55 CP: 295.96 1-10" 11.25° (MJxMJ) COUPLING STA: 0+24.40 CP: 293.31 INSTALL POLYPIG PER COR STD PLAN 300.7 5.95'28 LF 10" D.I. 14 LF 10" D.I. 19 LF 10" D.I. 13 LF 10" D.I. 16 LF 10" D.I. 3 LF 10" D.I. 4 LF 10" D.I. EX.SSMH #7 8" IE OUT 343.49 (W) RIM EL 354.13 STA 1+09.69 119 LF 10" D.I. 8.81% 3.00%EAST PLGRANT CIRCLE SEBLDG 4 & 5 LOT LINE (TYP)EX.SSMH #6 8" IE IN 335.16 (E) 8" IE OUT 335.16 (S) RIM EL 345.05 STA 5+51.20 PVI STA: 0+28.74 PVI EL: 346.93 K: 1.86 BVC STA: 0+22.74EL: 346.01EVC STA: 0+34.74EL: 347.4512' VC PVI STA: 0+16.10 PVI EL: 345.00 K: 0.98 BVC STA: 0+10.10EL: 344.82EVC STA: 0+22.10EL: 345.9112' VC STA: 0+00.00 ELEV: 344.51 END OF PAVEMENT STA: 1+22.20 ELEV: 355.16 1-10" TEE (MJxMJ) 1-10" 45° BEND (MJxMJ) STA: -0+06.81 CP: 337.22 1-10" VAVLE (MJxMJ) STA: -0+04.47 CP: 337.22 1-10" CAP (MJ) WITH CONC. BLOCK STA: 1+11.84 CP: 349.28 BLOW-OFF ASSEMBLY STA: 1+15.83 ELEV: 349.28 1" AIR-VAC 2.69'3.19'3.30'3.66'4.10'5.00'1.60'5.89'1-12"x10" CUT-IN TEE (FLxFL) 2-10" 45° VERT BEND (MJxMJ) TOP OF EX. 12" ALL MECHANICAL JOINT FITTINGS SHALL HAVE MEGALUG RESTRAINT RETAINER GLANDS (OR APPROVED EQUAL) BLDG 8 MIN. 3.00'3.03'2.56'GRANT AVENUE SEX R.O.W.2' ROD DED. 116 LF 10" D.I. 22 LF 10" D.I. 37 LF 10" D.I. EX. CB #1 12" IE 302.54 (E) 12" IE 302.54 (N) RIM EL 306.95 CB #2 12" IE 303.89 (W) 12" IE 303.89 (E) 12" IE 303.89 (N) RIM EL 307.56 EX.SSMH #3 STA 9+57.59 8" IE IN 305.28 (N) 8" IE IN 305.28 (E) 8" IE OUT 305.23 (SW) RIM EL 312.84 1-10"x6" F.H. ASSEMBLY STA: 8+37.33 CP: 315.59 1-10"x6" F.H. ASSEMBLY STA: 9+52.51 CP: 308.81 CONNECT TO EX 12" WA 1-12"x10" CUT-IN TEE (FLxFL) 1-10" VALVE (FLxMJ) 2-10" 45° VERT BEND (MJxMJ) WITH CONC BLOCK 1-2LF 10" SPOOL(MJxMJ) 2-12" GATE VALVES (FLxMJ) STA: 10+46.54 CP: 302.26 TOP OF EX. 12" STORM PIPE STA: 10+35.63 CP: 301.27 TOP OF EX. 8" HIGH PRESSURE GAS PIPE STA: 10+23.57 CP: 301.71 TOP OF EX. 8" HIGH PRESSURE GAS PIPE STA: 10+28.75 CP: 302.01 TOP OF EX. 12" STORM PIPE STA: 9+93.68 CP: 298.10 1-10" 11.25° BEND (MJxMJ) W/ CONC. BLOCK STA: 9+89.90 CP: 302.29 1-10" VALVE (MJxMJ) STA: 8+34.11 CP: 315.59 10" WATER MAIN STA: 10+30.27 CP: 300.23 CB #3 12" IE 305.00 (W) RIM EL 309.41 1.18'1.44'1.64'1.88'2.17'PROVIDE ETHOFOAM PAD AT GAS AND STORM CROSSINGS 1-10" 22.5° (MJxMJ) VERT BEND WITH CONC BLOCK STA: 10+07.54 CP: 300.22 PROVIDE ETHOFOAM PAD AT SEWER SIDE AND WATER SERVICE 3.00'3.92'4.46'RELOCATE EX. WATER MAIN 50 LF SECTION. SEE NOTES 1-10" 11.25° (MJxMJ) COUPLING W/ CONC. BLOCK STA: 10+02.28 CP: 301.50 INSTALL POLYPIG PER COR STD PLAN 300.70.81'12 LF 10" D.I.5 LF 10" D.I. 12 LF 10" D.I. 6 LF 10" D.I. - ALL WATER MAIN PIPES ARE 10" D.I. CL52 - STATIONS ON THE GRANT CIRCLE SE PROFILE ARE AS PER PIPE CL - STATIONS ON THE ALLEY ARE AS PER ACCESS END ALIGNMENT ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 V: 1"=10' H: 1"=30' WATER PROFILE GRANT CIRCLE SE (PRIVATE ALLEY) V: 1"=10' H: 1"=30' WATER PROFILE - GRANT CIRCLE SE (PRIVATE ALLEY)V: 1"=10' H: 1"=30' WATER PROFILE - ALLEY BLDG 4 AND 5 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTR46937 R Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WTR-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 WATER PROFILESGRANT PLACE TOWNHOMESC6.1LUA23-000283C23006099GRANT PLACE TOWNHOMESW-429002 PR23-000126MATCH LINE STA. 8+25.00MATCH LINE STA. 8+25.00NOTE: LOCATION AND ELEVATIONS FOR THE WATER MAIN ARE BASED ON POTHOLING AND AS-BUILT SURVEY NOTE: REPLACEMENT OF WATER MAIN WILL REQUIRE SHUT DOWN OF WATER SYSTEM. CITY FORCES SHALL PERFORM SHUT DOWN. WATER UTILITY ABDOUL GAFOUR 09/13/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WTR-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 WATER DETAILSGRANT PLACE TOWNHOMESC6.2LUA23-000283C23006099GRANT PLACE TOWNHOMESW-429003 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 WATER UTILITY ABDOUL GAFOUR 09/13/2024 DEVELOPMENT ENGINEERING NJanders 09/16/2024 NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24WTR-27-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 WATER DETAILSGRANT PLACE TOWNHOMESC6.3LUA23-000283C23006099GRANT PLACE TOWNHOMESW-429004 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 20' 20.5' 12' STA 4+84.98 (GRANT AVE) =STA 10+41.37 (GRANT CIRCLE S.E.) INSTALL STREET MONUMENT STA 3+58.81 (GRANT AVE) =STA 0+00 (GRANT CIRCLE S.E.) INSTALL STREET MONUMENT STA 5+46.92 (GRANT CIRCLE S.E.) =STA 0+00 INSTALL STREET MONUMENT TRACT C TREE RETENTION GRANT CIRCLE S.E. (PRIVATE) PRIVATE INGRESS ONLY EGRESS ONLY UNIT ADDRESS (TYP.) GRANT CIRCLE S.E. (PRIVATE) TRACT A GUEST PARKING SPACE GUEST PARKING SPACEWHITE ONE WAY ARROW PER WSDOT STD PLAN M24.40-02_E (TYP.) SEE SHEET C3.2 FOR DETAIL STREET NAME SIGN AND ONE WAY SIGN, SEE SHEET C3.2 FOR DETAIL PAINT CURB FACE AND TOP WITH FIRE LANE RED PAINT W/ WHITE "FIRE LANE" TEXT ON PAVEMENT @ 50' MAXIMUM O.C. (TYP.) NO PARKING FIRE LANE SIGN ON BOTH SIDES OF THE ALLEY AT 50 FEET MAXIMUM SPACING ALTERNATING FROM ONE SIDE TO THE OTHER (TYP.) SEE SHEET C3.2 FOR DETAIL STOP SIGN, SEE SHEET C3.2 FOR DETAIL 0+00 1+00 2+00 3+00 4+00 5+ 0 0 6+007+008+009+0010+00 NO PARKING FIRE LANE SIGN ON BOTH SIDES OF THE ALLEY AT 50 FEET MAXIMUM SPACING ALTERNATING FROM ONE SIDE TO THE OTHER (TYP.) SEE SHEET C3.2 FOR DETAIL 0+00 1+00 15' PUBLIC SEWER ESMT 20'3+004 + 0 0 5+00 6+00 1.5' R.O.W. DEDICATION GUEST PARKING SPACES S61°18'03"W 62.51' L =1 9 .4 7 ',R =4 0.00'Δ =2 7 °5 3 '0 3"S89°09'29"W 388.83'L=49.25',R=38.00 'Δ=74°15'30"N0°46'40"W 16.79'N0°46'40"W 29.97'L =5 9 .6 5 ',R =38.00'Δ =8 9 °5 6 '09"N89°09'29"E 349.62'L=25.03', R=60.00' Δ=23°53'56" N89°09'29"E 122.20' GUEST PARKING SPACES TRACT ATRACT A 10' STORM DRAINAGE ESMT STREET NAME SIGN, ONE WAY SIGN, AND DO NOT ENTER SIGN SEE SHEET C3.2 FOR DETAIL 15' PUBLIC SEWER ESMT 10' STORM DRAINAGE ESMT N65°15'33"E 27.22' WHITE ONE WAY ARROW PER WSDOT STD PLAN M24.40-02_E (TYP.) SEE SHEET C3.2 FOR DETAIL PAINT CURB FACE AND TOP WITH FIRE LANE RED PAINT W/WHITE 18 INCHES HIGH "FIRE LANE" TEXT ON PAVEMENT @ 50' O.C. (TYP.) FIRE LANE SIGN FIRE LANE SIGN FIRE LANE SIGN FIRE LANE SIGN SITE INFORMATION: ADDRESS:1600 GRANT AVE S PARCEL NUMBER:202305-9052 ZONING:RM-F PARCEL AREA:92,051 SF (2.11AC) NOTES: ALL ONSITE ROADWAYS SHALL BE MARKED AND SIGNED PER CITY STREET STANDARDS AS FIRE LANES. N TRACT A (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) TRACT B (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) TRACT B (INGRESS, EGRESS, UTILITY, AND OPEN SPACE) IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 HORIZONTAL CONTROL, SIGNAGE AND STRIPING PLANGRANT PLACE TOWNHOMESC7.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429017 T-429002 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026TRO-41-4290DEVELOPMENT ENGINEERING NJanders 09/16/2024 CC N IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE FORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES 1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 TREE RETENTION PLANGRANT PLACE TOWNHOMESC8.0LUA23-000283C:XXXXGRANT PLACE TOWNHOMESR-429018 XXXXXph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 JDing 09/03/2024 CURRENT PLANNING DEVELOPMENT ENGINEERING NJanders 09/16/2024 IN COMPLIANCE WITH CITY OF RENTON STANDARDS NE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMES 8/23/2024RGG N A F U R SE F ORP I ANO EL T S GE SI N ERE D EEATDSNTA WFO . SAHI IN REENOTRR Know what's below. Call before you dig. FURR ENGINEERING SERVICES PLLC. DOES NOT WARRANT THE TOPOGRAPHY, BOUNDARY, AND/OR EXISTING UTILITIES SHOWN ON THESE PLANS. IT IS THE CONTRACTORS' RESPONSIBILITY TO HAVE ALL EXISTING IMPROVEMENTS FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY SUBSURFACE EXPLORATION OF EXISTING UNDERGROUND UTILITIES (POWER, WATER, SEWER, TELECOM, ETC.) SHALL BE PERFORMED BY THE CONTRACTOR. DISCREPANCIES BETWEEN WHAT IS SHOWN ON THE PLANS AND LOCATED BY THE CONTRACTOR SHALL BE BROUGHT TO THE ATTENTION OF FURR ENGINEERING SERVICES PLLC.. PRIOR TO CONSTRUCTION ACTIVITIES. 1 PER CITY COMMENTS DAF 04/04/24 2 PER CITY COMMENTS DAF 05/21/24 3 PER CITY COMMENTS DAF 07/29/24 4 PER CITY COMMENTS DAF 08/26/24TED-40-4290GRANT PLACE TOWNHOMES1600 GRANT AVE S RENTON, WA 98055 PARCEL 2023059052 FIRE GATES DETAILGRANT PLACE TOWNHOMESC9.0LUA23-000283C23006099GRANT PLACE TOWNHOMESR-429019 PR23-000126ph 206.890.8291 4715 142nd Pl. SW #B, Edmonds, WA 98026 DEVELOPMENT ENGINEERING NJanders 09/16/2024 GRANT CIRCLE S.E.GRANT CIRCLE S.E.TREE PRESERVATION LEGENDTREE INVENTORYTREES SAVEDIN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNSCALE: 1" = 20'- 0"N20'05'40'PROPERTY LINERIGHT-OF-WAYPROPOSED RETAINING WALL,TYP.EXISTING UNDERGROUNDSTORMWATER VAULTPROPERTY LINENOTES:1.REQUESTING TO PAY A FEE IN LIEU OFANY MISSING REQUIRED TREEREPLACEMENT PER 4-4-130 'TREERETENTION AND LAND CLEARINGREGULATIONS' BASED ON PROVIDING ASMANY TREES AS THE PROJECT SITE CANMAINTAIN WHILE AVOIDING ALL RETAININGWALL, UTILITIES AND EASEMENTS.TREE RETENTION PLANL1.1MATCHLINE - SEE SHEET L1.2 R-429022JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 PRIVATE ALLEYIN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNSCALE: 1" = 20'- 0"N20'05'40'UNHEALTHY SIGNIFICANTTREES THAT HAVE BEENRETAINED AND WILLBECOME 10'-20' HT. WILDLIFESNAGSUNHEALTHY SIGNIFICANTTREES THAT HAVE BEENRETAINED AND WILLBECOME 10'-20' HT. WILDLIFESNAGSUNHEALTHY SIGNIFICANTTREES THAT HAVE BEENRETAINED AND WILLBECOME 10'-20' HT. WILDLIFESNAGSUNHEALTHY SIGNIFICANTTREES THAT HAVE BEENRETAINED AND WILLBECOME 10'-20' HT. WILDLIFESNAGSNOTES:1.REQUESTING TO PAY A FEE IN LIEU OFANY MISSING REQUIRED TREEREPLACEMENT PER 4-4-130 'TREERETENTION AND LAND CLEARINGREGULATIONS' BASED ON PROVIDING ASMANY TREES AS THE PROJECT SITE CANMAINTAIN WHILE AVOIDING ALL RETAININGWALL, UTILITIES AND EASEMENTS.TREE RETENTION PLANL1.2MATCHLINE - SEE SHEET L1.1 R-429023JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 LANDSCAPE SCHEDULELEGENDGRANT CIRCLE S.E.GRANT CIRCLE S.E.IN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNSCALE: 1" = 20'- 0"N20'05'40'PROPERTY LINESOLID WOODFENCE, HT TBDEXISTING 4' HT.LANDSCAPEBLOCK WALL.PLANT ONE ROWOF KINNICHINNIKALONG TOP. ALLOW TOCASCADE DOWN WALL.MAINTENANCE ACCESSDRIVE: NDS TUFFTRACKLAWN PAVERPLAY FIELDOPEN SPACE #1OVER UNDERGROUNDSTORMWATERVAULT42" HT. SPLIT RAILFENCEPLAZA WITH PICNIC TABLESKINNIKINNICK TOCASCADE DOWN4' HT. WALLKINNIKINNICK TOCASCADE DOWNFACE OF WALL20'X20'SITE CLEAR ZONE20'X20'SITECLEAR ZONEPRIVATEOPEN SPACE,FRONT YARDS, TYP.DECORATIVE PAVING /FIRE LANE. NO PARKINGLOCATIONOF ENTRYMONUMENT42" HT.SPLIT RAILFENCESTART EASEMENT,NORTH PROPERTY LINEBUFFER PLANTING AREA.REF CIVIL DWGS.FIRE HYDRANT, TYP.CONCEPTUAL LANDSCAPE PLANL3.1MATCHLINE - SEE SHEET L3.220'X20'SITECLEAR ZONE20'X20'SITE CLEAR ZONESEATINGAREASEATINGAREA10' FULLY SIGHT-OBSCURINGLANDSCAPE BUFFER, SEE SHEETL3.210' LANDSCAPE BUFFER, AVERAGED.SOUTH AND EAST PROPERTY LINES.*UNDERGROUND UTILITIES IN BUFFER STRIPALONG SOUTH PROPERTY LINE, NO TREES.OPENSPACE#2 & #3R-429024JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 PRIVATE ALLEYENHANCED LANDSCAPE PROVIDEDIN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNSCALE: 1" = 20'- 0"N20'05'40'CONCEPTUAL LANDSCAPE PLANL3.2MATCHLINE - SEE SHEET L3.1SEATINGAREASEATINGAREA SOLIDWOODFENCE, HT TBD42" HT. SPLIT RAIL FENCEAROUND TREE PROTECTIONAREA.OPEN SPACE #7SEATING AREAWITH 6'X22'TRELLIS, TBDTREE PROTECTION TRACT.OPEN SPACE #8PROPERTY LINEBENCH,MODELTBD, TYP.DECORATIVE PAVINGIN FIRE LANE, TYP. NO PARKING10' FULLY SIGHT-OBSCURINGLANDSCAPE BUFFER, SEE SHEETL3.210' LANDSCAPE BUFFER, AVERAGED.SOUTH AND EAST PROPERTY LINES.*UNDERGROUND UTILITIES IN BUFFER STRIPALONG SOUTH PROPERTY LINE, NO TREES.3' WIDE SOFT PATH,LAYOUT TBDOPENSPACE#4 & #5OPENSPACE#6MAINTAIN VIEW TO THEWEST, DOWN CORRIDORAND BEYONDNOTES:1.SEE SHEET L3.3 & L3.4 FOROPEN SPACE AND LANDSCAPEREQUIREMENTS.END EASEMENT,NORTH PROPERTY LINEBUFFER PLANTING AREA.REF CIVIL DWGS.RIVER ROCK AT BASEOF SLOPE/S. PROVIDE YARDDRAIN OR SUMP AS NEEDED, TYP.R-429025JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 LANDSCAPE CALCULATIONSLEGENDIN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNOPEN SPACE PLANL3.3SCALE: 1" = 20'- 0"N20'05'40'MATCHLINE - SEE SHEET L3.4 PROPERTY LINESEATINGAREASEATINGAREA10' SIGHT OBSCURING LANDSCAPEBUFFER REQUIRED, 5' PROVIDED. VARIANCEREQUESTED. SOLID WOOD PANEL FENCE 4' - 6' HT.AND SOLID EVERGREEN HEDGE TO BE MAINTAINEDAT 8' HT.10' LANDSCAPE BUFFERS ALONGSOUTH AND EAST PROPERTY LINES,AVERAGED. 6 HT. WOOD PANEL FENCE.UTILITIES ALONG SOUTH BUFFER, NOTREES. VARIANCE REQUESTED.10' FRONTAGEBUFFERR-429026JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 GENERAL NOTES:PLANTING NOTES:IN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNOPEN SPACE PLANL3.4SCALE: 1" = 20'- 0"N20'05'40'MATCHLINE - SEE SHEET L3.3 SEATINGAREASEATINGAREASEATING AREAWITH TRELLIS, TBDPROPERTY LINEDECORATIVE PAVINGIN FIRE LANE, TYP. NO PARKING10' SIGHT OBSCURING LANDSCAPEBUFFER REQUIRED, 5' PROVIDED. VARIANCEREQUESTED. SOLID WOOD PANEL FENCE 4' - 6' HT.AND SOLID EVERGREEN HEDGE TO BE MAINTAINEDAT 8' HT.10' LANDSCAPE BUFFERS ALONGSOUTH AND EAST PROPERTY LINES,AVERAGED. 6 HT. WOOD PANEL FENCE.UTILITIES ALONG SOUTH BUFFER, NOTREES. VARIANCE REQUESTED.R-429027JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 ·●● ●·●·●● 1LANDSCAPE BOULDERnot to scale2SOIL AMENDMENT PROFILEnot to scale3STREET TREE PLANTINGnot to scale6DECIDUOUS TREE PLANTINGnot to scale4EVERGREEN TREE PLANTINGnot to scale8TYPICAL PLANT SPACINGnot to scale9MULTI-TRUNK TREE PLANTINGnot to scale10SHRUB PLANTINGnot to scale7DECIDUOUS TREE PLANTING ON SLOPEnot to scale·5EVERGREEN TREE PLANTING ON SLOPEnot to scaleIN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNPLANTING & SITE DETAILSL3.5R-429028JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024 2GROUNDCOVER PLANTING - 1 GAL.not to scale442" HT. SPLIT RAIL FENCEnot to scale42" HT. SPLIT RAIL FENCE WITH OPTIONAL METAL MESHnot to scale36' HT. WOOD PANEL FENCEnot to scaleSECTIONELEVATIONPLAN·1SHRUB PLANTING ON SLOPEnot to scale510' - 20' HT. WILDLIFE SNAGSnot to scale6IN COMPLIANCE WITH CITY OF RENTON STANDARDSNE 1/4 OF THE SW 1/4 OF SEC. 20, T. 23N., R. 05 E, W.M.GRANT PLACE TOWNHOMESRKnow what's below.Call before you dig.TINA M. VINCENTNO. 1317 EXP. 08/26/2024 LANDSCAPE ARCHITECT Tina Vincent, PLA, ASLAlandscape architect(206) 913-9216P.O. Box 1744Edmonds, WA 98020tina@vindesigngrp.com11/16/231Report to the Hearing Examiner,10-2-23PARCEL 20230590521600 GRANT AVE S RENTON, WA 98055GRANT PLACE TOWNHOMESGRANT PLACE TOWNHOMES R-NNNNNNNTMVTMVTMVAS SHOWNPLANTING & SITE DETAILSL3.6R-429029JDing 09/03/2024CURRENT PLANNINGDEVELOPMENT ENGINEERINGNJanders 09/16/2024