Loading...
HomeMy WebLinkAboutMFP24004458.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24004458 IVR Number: 24004458 Permit Information Permit Name: Comcast - 1301 SW 16th St - JB-1916676 Address/Location:09/03/2024Application Date:2423049022Parcel Number: 1301 SW 16TH ST Permit Type:09/25/2024Issue Date:Franchise Permit Work Class:09/25/2025Expiration Date:Minor Utility Job Number: JB-1916676Franchise Type:Cable Description: Comcast JB 1916676 Splicing in three locations Contacts Name Address PhoneTypeBilling Jacob Neu ADP-Resources, LLC 163 SW Academy St. Dallas, OR 97338 ApplicantX Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Contact CABLECOM LLC 20021 120th Ave NE, #101 BOTHELL, WA 98011 B: (360) 668-1300Contractor Business License Number: 52252Construction Contractor: CABLEL*971DP Joshua Ashley Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (503) 939-7931Emergency Contact ALASKA AIRLINES INC 19300 INTERNATIONAL BLVD SEATTLE, WA 98188 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering MFP24004458 Monday Friday 3:00pm8:00am Scott Warlick CED 9/25/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) SHIFTING PLAN, 3 LANE STREETFTFT = ½ LINDICATE NORTHTURN LANE TAPERSHALL MAINTAIN 10' MINIMUMLANE WIDTH AT ALL TIMES100 FT per lane maximumDOWNSTREAM TAPERVARIABLE AS NEEDEDWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________ANDBUFFER SPACEFTOPTIONAL___________________________POSTED SPEEDOPTIONALFT = ½ LSHIFTING TAPERDRAWING NOT TO SCALEALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)SF-112WORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.SW 16TH ST125350350350SW 16TH STOAKESDALE AVE SWLONGACRES DR SW35 MPH2451251 TCP 1REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 5 08/29/2024 -- -- -- -- HOWARD S WRIGHT 1301 SW 16TH ST RENTON, WA 98057 CITY OF RENTON NTS JB-1916676 TRAFFIC CONTROL PLAN J. MITCHELL T. MOORE MFP24004458 SHIFTING PLAN, 3 LANE STREETFTFT = ½ LINDICATE NORTHTURN LANE TAPERSHALL MAINTAIN 10' MINIMUMLANE WIDTH AT ALL TIMES100 FT per lane maximumDOWNSTREAM TAPERVARIABLE AS NEEDEDWORK SITE ADDRESS_________________________________________________STREET NAME____________________________BETWEEN___________________________ANDBUFFER SPACEFTOPTIONAL___________________________POSTED SPEEDOPTIONALFT = ½ LSHIFTING TAPERDRAWING NOT TO SCALEALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)SF-112WORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.SW 16TH ST125350350350SW 16TH STOAKESDALE AVE SWRAYMOND AVE SW35 MPH2451252 TCP 2REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 5 08/29/2024 -- -- -- -- HOWARD S WRIGHT 1301 SW 16TH ST RENTON, WA 98057 CITY OF RENTON NTS JB-1916676 TRAFFIC CONTROL PLAN J. MITCHELL T. MOORE MFP24004458 LANE CLOSURES AT INTERSECTION 5 LANE STREET, BOTH LEGSINDICATE NORTHDRAWING NOT TO SCALEPLACE SIGNS ON ALL SIDESTREETS, WITHIN THETRAFFIC CONTROL ZONEFT____________________________________________STREET NAME and POSTED SPEEDFT = LMERGING TAPERFTALL LENGTHS ARE MINIMUMDISTANCES UNLESSOTHERWISE NOTEDFTSight distance shall be maintained at all public and private intersections and driveways. If sight distance is not achievable, prior approval by the TrafficEngineer is required to either restrict turn movements or use flaggers and shall include coordination with the affected property/business owner(s).(TCP REF)LC-220-MODFT____________________________________________ STREET NAME and POSTED SPEED FTWORKZONENOTES:1.ALL SPACING SHOWN IN FEET.2.CHANNELIZING DEVICES SPACING IS 20'O.C.3.RECOMMENDED EXTENDING CHANNELIZINGDEVICE TAPER ACROSS SHOULDER.4.KEEP DRIVEWAYS OPEN WHEN POSSIBLE5.THIS PLAN IS SUBJECT TO CHANGE TO MEETFIELD CONDITIONS.6.NON-FREEWAY SIGNS SPACING MAY BEMADE TO FIT FIELD DIMENSIONS SHOWN.7.PLACE APPROPRIATE SIGNS ON ALL SIDESTREETS.8.RESTRICTED SIGHT DISTANCES REQUIRESADDITIONAL ADVANCE WARNING DEVICEOR SIGNS.9.SIGNS ARE 48"x48" IN SIZE. CONES ARE ATLEAST 28" TALL.10.NIGHT WORK REQUIRES ADDITIONALROADWAY LIGHTING AT FLAGGINGSTATIONS.11.WORK VEHICLE LOCATED IN SAME AREA ASWORK LOCATION.12.POSTED SPEED: EQUIVALENT TO THEEXISTING, POSTED OR STATUTORY SPEED.13.ADHERE TO BICYCLE ACCOMMODATIONWHEN BICYCLE LANE IS PRESENT14.A SPOTTER IS REQUIRED TO ASSISTPEDESTRIANS AROUND WORK SITE.PEDESTRIAN ACCESS MUST REMAIN CLEARAT ALL TIMES.15.COORDINATE WITH THE FOLLOWING CITYDEPARTMENTS AT LEAST 48 HOURS INADVANCE: POLICE, FIRE, EMERGENCY,PUBLIC TRANSIT, PARKING.SHALL MAINTAIN 2-10' MINIMUMLANE WIDTHS AT ALL TIMES FOR2 WAY TRAFFIC OR 20' MINIMUMWIDTH FOR 2 WAY TRAFFIC ONSTREETS WITHOUT LANESTRIPINGSW 16TH ST 35 MPHLIND AVE SW 35 MPH 125350350350350350350 3 TCP 3REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 5 08/29/2024 -- -- -- -- HOWARD S WRIGHT 1301 SW 16TH ST RENTON, WA 98057 CITY OF RENTON NTS JB-1916676 TRAFFIC CONTROL PLAN J. MITCHELL T. MOORE MFP24004458 BICYCLE ACCOMMODATION4 REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 5 08/29/2024 -- -- -- -- HOWARD S WRIGHT 1301 SW 16TH ST RENTON, WA 98057 CITY OF RENTON NTS JB-1916676 TRAFFIC CONTROL PLAN J. MITCHELL T. MOORE MFP24004458 PEDESTRIAN ACCOMMODATION5 REVISED DATE: SHEET:FIELDED BY :OF 163 SW ACADEMY ST, DALLAS, OR 97351 (503) 400-7440 DRAFTED BY : SCALE: 11308 SW 68TH PKWY TIGARD, OR 97223 800.266.2278 5 08/29/2024 -- -- -- -- HOWARD S WRIGHT 1301 SW 16TH ST RENTON, WA 98057 CITY OF RENTON NTS JB-1916676 TRAFFIC CONTROL PLAN J. MITCHELL T. MOORE MFP24004458 APPROACH PLAN LABOR: AERIAL: TOTAL AERIAL FOOTAGES = 0’ UNDERGROUND: TOTAL UG FOOTAGES = 0’ PERMITS TO BE SUBMITTED: CITY OF RENTON TRAFFIC CONTROL PLAN Legend FIELD DATE 08/22/24 Reference DG JB-1916676 Howard S Wright 1301 SW 16th St Renton WA 98057 Splicing required at existing SP0302.WAKV TCP -1 MFP24004458 APPROACH PLAN Legend Reference DG JB-1916676 Howard S Wright 1301 SW 16th St Renton WA 98057 Splicing required at Existing SP.WAKV.0807 15’ FROM POLE 1:Splicing required at existing SP.WAKV.0554 TCP -2 MFP24004458 APPROACH PLAN Legend Reference DG JB-1916676 Howard S Wright 1301 SW 16th St Renton WA 98057 Splicing required at existing SP.WAKV.0153 TCP -3 MFP24004458