Loading...
HomeMy WebLinkAboutR-430612MAPLEWOOD HEIGHTS ELEMENTARY SCHOOL A PORTION OF THESE 1/4 OF THE NE 1/4 OF SEC. 15, TWNm 23 N., RGEm 05 E. W.M. CITY OF RENTON, KING COUNTY, WASHINGTON. Dow Sign Lnuelope ID: 3131 133403 TFQA-476G-AD 133.4329FFF-OCIQ8 0 a OPEN PICKM i- 1-1A I FAu= (ju I H IC: {2y 2iW-15 SS SOCKET HEAD CAP SCREW (A_.LENHEAD)WIWSHRS ON A W DIA BOLT CIRCLE CAST IROK FRAME AND COVER, SEE NOTE 3 -- :� c 8- ASPHALT. SEE NQTI=1 CLEANDUT RISER, SEE NOTE 2 SOIL TIGHT 45' BEND WYE �VDIA � £S•si13` DIA Ta1R DIA 15" PIA FRAME SECTION PAVED AREA [TYP. ) CLfAN4UT RJ$ER. SEE NOTE 2 , SOIL TIGHT y - COUPLER tMDE RORA IN, FOOTING DRAIN CDLLI`CTOR, OR - i` ROOF DRAIN COLLECTOR PFPF, SEE NOTE 1 I CLEANOUT RISER LOCATED WITHIN .�-� llllh I1 TO QVERFLt]W STRUCTURE 0,R ��`��nn.• $TQRU MAIN ,{ f MECrtAN ICAL PLUG OR CON71INUED CDNNECTTON TYPICAL CLEANOUT CONFIGURATION ELEVATION B-13OU' CIA 54v COVER SECTION ' I EXTEND GLEAN4UT RISER a` ABOVE DESIGN PONDINN3 ELEVATION OR PER PLANT :� ± � Z7FSI['i,N PONTJING _ F4'GC1WACTE0 SAND OR GRAVEL BACF{FLL1 FOR DRAINS R ER WSODT 9-173.12(d 1 FERNCD GA,I#df ETE�T OIJNK CAP OR SIMILAR 4" STiiGJ4f'AHED Cn69LE': — PER WSDOT E-0.3-11(2) NOTESo I. DIAMETER TO BE 8-INCHES F,iNIMUM PRIVATE, S-INCHES MIN1µ1_ M PUELIC UNDERDRAI�N PIPE PER STD- PLAN 252,10. 2, CLEANOuT RISER SHALL BE SAME MATERIAL AS CONNECTED udNDERDRAIN, FOOTING DRAIN COLLECTOR, QR ROOF DRAIN COLLECTOR PIPE 3, FRAME AND COVER SHALL BC Ed PRODUCTS 3BT5ZIPT AND N75APT OR APPROVED EOUX, COVER TO BE LOCKING WITH ALLEN HEAD BOLT. MARKED -STORM` CR �RAIH' 4, FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BbORETENTION PONDING AREA. POUR 8' THHC4. Y32' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSN GENERAL NOTES: 1, CLEANOUTS FOR UNDERORMN. FOOTING DRAIN COLLECTOR, AND ROOF DRAINi COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY IOD FEET. AT EVERY 90 DEGREE OR SECOND 45 DEGREE aEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE CLEANOIITH SHALL BE INSTALLED TO ALLaW FOR MniNTE1fAJNCE ACCESS TO ALL PIPES FITTINGS 2 ALL SHALL BE SCIL T1GHT. 3 CLEANGUT RISER SHALL BE LOCATED OUTSIDE OF BIOREfENTIDN PON DING WHERE POSSIBLE 4. CLEANCuTS SHALL NOT FiE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERwiSE APPROUEI} 13Y THE CFTY. UNLESS OTHERWISE NOTED. DRAWING15NOTTOSCALE!NTS, 5TD, PLAN - 2, "00 PUBLIC WORKS N+eD IIPlaauy; *11 DEPARTMENT STORM SYSTEM CLEANOUT artin Pastucha1: �A�j$�����a o ' sldwu DATE STORM DRAIN CLEAN OUT NOT TO SCALE o- 0 S0 Know what's beIow. Call before you dig. 18: LL 19 CORNER OR END POSTS 10' MAX. - SEE SPECIFICATIONS KNUCKLE FABRIC 1/2 WAY UP RAIL FOR SAFETY (TOP AND BOTTOM) FENCE FABRIC, 2" GALVANIZED MESH - SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION CONCRETE FOOTING 2'-0" M I N NOTES: 1. SUBMIT SHOP DRAWINGS FOR ALL FENCES AND GATES. 2. SEE SPECS FOR FINISH INFO. 3. ALL POSTS TO BE INSTALLED WITH CAPS. CHAINLINK FENCE NOT TO SCALE CORNER OR END POSTS BRACE RAIL X GALVANIZED CHAIN -LINK FENCE FORK LATCH KIT DIA. TRUSS ROD FOR GATES 6' AND WIDER VARIES - J N SEE PLANS 10" MIN. 0 PER PLANS 6" TYP. SWING PERSON GATE NOT TO SCALE TOP RAIL BOTTOM RAIL 10" MIN. DIA STANDARD GATE HINGE FENCE FABRIC - 2" GALVANIZED MESH BANDS AND STRETCHER BAR AT END AND CORNER POSTS %4" X 1/4" FLAT STRETCHER GATE FRAME HOLD BOTTOM RAIL BETWEEN 1 1/2" AND 2" FROM FINISHED GRADE FINISH GRADE CONCRETE FOOTING NOTES: 1. SUBMIT SHOP DRAWINGS FOR ALL FENCES AND GATES. 2. SEE SPECS FOR FINISH INFO. 3. ALL POSTS TO BE INSTALLED WITH CAPS. R=430612 LO LO N 0 0 N rig TACOMA - SEATTLE • SPOKANE • TRI-CITIES 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Project Title: MAPLEWOOD HEIGHTS ELEMENTARY SCHOOL Client: RENTON SCHOOL DISTRICT ANDREW HOLLENBACK 300 SOUTHWEST 7TH STREET RENTON, WA 98057 Project No. 2230871.10 Issue Set & Date: PERMIT SET J U N E 21, 2024 6/20/2024 NOTICE ALTERATION OF THIS DOCFIIENT SHALL IWADATE THE PROFESSIONAL SEAL AND SIGNATURE PUBLICATION OF THIS DOCUIENT DOES NOT DEROGATE FROM RESERVED OMlERM RK M N IT. THIS DWAIENT IS FOR USE ONLY FOR THE PKIECT WIRED N THE TIRE BLOCK AID IS NOT TO BE USED FOR REPAR, REMODEL OR ADDITION TO THAT PROM OR FOR ANY OTHER PKIECT. A A A Revisions: Sheet Title: NOTES AND DETAILS Designed by: Drawn by: Checked by: JH JH DCN Sheet No- 5 ■ 12 of 12 Sheets